OXYGEN CONCENTRATOR USER MANUAL
1
CATALOGUE
PREFACE·········································································2
IMPORTANT SAFEGUARDS················································3
RELATED USE SYMBLE DESCRIPTION································7
CHECK PACKAGE AND PACKING LIST·································8
PRODUCT OPERATING PROCEDURE··································8
PRODUCTION INTRODUCTION··········································11
STRUCTURE···································································· 11
SCOPE OF APPLICATION ··················································11
CONTRINDICATION··························································· 11
ENVIRONMENT REQUIREMENT ·········································11
TRANSPORTATION AND STORAGE CONDITIONS·················12
ADDITIONAL REMARKS·····················································12
PURITY VALUE AND FLOW FUNTIONS CHART·····················13
TECHNICAL PARAMETERS ················································14
COMPONENTS NAME AND FUNTIONS DESCRIPTION···········15
CLEANING AND MAINTENANCE INSTRUCTIONS ··················18
WARRANTY ·····································································18
FAULT AND REPAIRING COMPARISON TABLE·······················19
ELECTROMAGNETIC IMMUNITY········································· 21
ENVIRONMENT PROTECTION············································ 23
MANUFACTURER INFORMATION········································ 24

OXYGEN CONCENTRATOR USER MANUAL
2
PREFACE
Dear user:
Thank you for your support!Hope you can be our satisfied user.
This manual describes the notices, operation steps, basic
functions , technical parameters, basic troubleshooting, return repair
instructions and other content, so that you will be familiar with the
products and operate the machine well.
In order to ensure the effective use of this machine, please read
the instructions carefully on the use of this manual. Before you
operate the machine, please make sure that you have read and
understand the basic operation of this product. Please pay special
attention “IMPORTANT SAFEGUARDS”.
Please note that some illustrations in this manual is not exactly
the same with the machine you see.
The humidification bottle, oxygen tubes / oxygen masks, filters
and other random components mentioned in this manual should be
selected in accordance with the requirements of product
specifications.
If you have some problems for the usage, kindly feel free to
contact the after sale service of the manufactuerer.
Vession:V0

OXYGEN CONCENTRATOR USER MANUAL
3
IMPORTANT SAFEGUARDS
DANGER (If broke the regular operation,may arise serious
injury or death.)
The measures to decrease burn, electric shock, fire or human
injury risk. Avoid using the machine when take bath.If needed ,
Please follow up the doctor, and the oxygen machine must be used
in another room 2.5 meters away outside the bathroom.Suggested
that the oxygen p nasal oxygen tube is less than 11 meters and keep
clear.
Do not place or store in the place where is easy to drop into the
water or other liquid.
◆Oxygen causes rapid burning. Do not use within 5 feet (1.6m )of hot,
sparking objects or naked sources of flame.
◆Do not smoke while your oxygen concentrator is operating, or when you
are near a person utilizing oxygen therapy.。
◆The inappropriate use of power line and a plug, may cause a fire or other
dangerous electric shock, burn, do not use the machine with broken
power line .
◆Before cleaning the machine dust in the shell must pull out the power
plug to prevent electric shock.
◆When the machine is working, please do not open the machine shell
and internal box to prevent the damage caused by mechanical touch
operation.
WARNING (The following items must be strictly enforced,
otherwise it may cause serious consequences.)
◆In order to prevent the oxygen failure or power outage, always need
oxygen (such as the urgent need for oxygen and severe patients) need

OXYGEN CONCENTRATOR USER MANUAL
4
oxygen supply device also configure other spare (such as oxygen bottles,
oxygen bag etc.).
◆This product can not be used to maintain any life, the patients with
aerobic treatment are suggested to follow up your doctor's guidance to
choose the oxygen flow and time when using this machine.
◆If any discomfort or abnormal reaction arise, please immediately stop
using this product, and contact the manufacturer or doctor.
◆The seriously ill patients need additional configuration indicating
equipment in the use of the products, or require additional medical
coordination. Please consult a doctor before use. If you have any
adverse reactions, please inform your doctor immediately.
◆All the products if use in the altitude of over 2000 meters, the maximum
recommended flow at rated oxygen concentration, the outout purity will
be less than 90%.
◆Do not let many people use the same set of nasal oxygen tube or oxygen
mask, so to avoid cross infection caused by viruses or bacteria between
users.
◆We should use the required specification humidification bottle. Do not
replace it arbitrarily, otherwise it may cause discomfort or not oxygen
inhalation hazard.
◆The nasal oxygen tube should not be placed under the coverlet or
cushion when use the machine, and cannot sit in pressure oxygen
connecting tube to make sure use sucessfully and efficiency.
◆When no one use, it is recommended to turn off the power switch, and
set off the plug to avoid the burning.
◆The use of this product, pay attention to whether the power line is to
long to obstruct other walking so advice to use near the power socket.
◆This product can not be equipped with the non humidification bottle
specified or dosing accessories, So as not to affect the performance of the
product.

OXYGEN CONCENTRATOR USER MANUAL
5
CAUTIONS(Notice to the following content to avoid breaking
the machine)
◆Do not open the machine shell and internal boss to do the maintenance.
If users found some problems, or found abnormal alarm, do not
disassemble the repair, should contact the dealer or manufacturer
immediately.
◆It should be placed in the clean and free of dust, on corrosive and
poisonous environment. Do not use this product under the condition of
strong magnetic field environment.
◆The air entrance of the machine should be located in a well ventilated
and the air source inlet should be in place at least the pollutants
(including / pollutants refers to: burning gas, exhaust system, air vents
and other anesthesia vacuum exhaust port etc.).
◆Please connect the separate (wall mounted) AC power outlet while using
this product, do not connect the Do not connect the row insert board
seat. Do not use with other electrical appliances at the same time use the
power supply socket.
◆This machine is strictly prohibited contact with oil and grease, such as the
need to connect to other pipelines, valves, connectors, the use of this
product, the connection set before the installation should be cleaned to
ensure clean and no oil (grease) category. In the connection process, pay
attention to keep all parts of the cleaning, the connection of the whole
machine is strictly prohibited to touch any combustible oily liquid.
◆To ensure that the bottom of the exhaust flow efficiency while use the
machine. The back do not paste the wall, at least 30 cm from the wall,
otherwise it will cause damage to the machine overheating.
◆This machine is not frequent opening and closing, shut down after the
start, the time interval of not less than 5 minutes, so as not to affect the
service life of the compressor, the manufacturers recommend each
operation is better over 30 minutes.
◆The machine is only used as a medical oxygen supply, the output of the

OXYGEN CONCENTRATOR USER MANUAL
6
gas in the rated flow, the purity can up to 90%.
◆Rotary flow control knob can not be forced too hard, or easy to damage
the spool. When the flow control knob is turned on to the highest, but
the flow indicator is zero, please turn off the power and then check the
fault.
◆When receive the products to operate and test, cut off the tie on the
bottom of the machine otherwise it will cause damage to the machine.
NOTICE(You must pay special attention to the information.)
◆The purity will be up to 90% after boot for 10min.
◆The nasal oxygen tube, oxygen mask used by patience need to be
clean ,sterilize if need to use repeatly.
◆The oxygen machine parts, humidification bottle need to be cleaned
every 2 to 3 days and the Air intake flitering foam need to be cleaned
every 100 hours. The Air filter is recommended to be replaced after 1000
hours of machine use. Such as the use of the product environment dust
or soot larger, the above parts, please reduce the time of cleaning or
replacement. In order to ensure the use of the effect, the proposed early
replacement of the parts.
◆The use of water can be used as a humidified bottle must be distilled
water or cold water, please do not directly put into the untreated tap
water. The water bottle should be cleaned every 2 ~ 3 days from the time
the summer, recommended daily replacement, if used after a few days
without this product, please put all the water drained, humidifiedbottle
dry stand-by.
◆Select the nasal oxygen tube and oxygen mask with the same
specification with the equipped one. If change the different one,ask the
professional one or the manufacturer first.
◆Do not throw the humidification bottle, nasal oxygen tube and mask at
any place. The nearby waste disposal mechanism is the best choice.

OXYGEN CONCENTRATOR USER MANUAL
7
◆Please select the suitable humidification bottle ,rotate and fix in the
machine as required. Do not use under the revolving situation.(Refer to
the humidified bottle connection indicator diagram).
◆When use the humidification bottle,pay attention to add water as the
highest and lowest water level marked on the bottle body.
◆When this machine is scrapped, please contact your local supplier or
manufacturer.
◇Please refer to“RELATED USE SYMBLE DESCRIPTION” to know the
machine, package symbol.
◇Please refer to“CHECK PACKAGE AND PACKING LIST”to test the
equipped components after receive the goods and before use and
then operate it as “PRODUCT OPERATING PROCEDURE”.
RELATED USE SYMBLE DESCRIPTION
OOFF(POWDER)ION(POWDER)
Follow the instructions No open flame
No Smoking Produating Date
Safeguard Serise Number
Cautions Up Put
Double insulated Avoid the rain Keep dry
Type BF applied part Fragile handle with care.
230V~AC 230V Forbidden to sit
Non-ionizing electromagnetic radiation
Waste Electrical and Electronic Equipment Directive 2002/96/EC
(WEEE Directive)after over the valid term within 3 years, the machine
should be treated on local law or regulation requirement. To avoid hurt
users and pollute environment.

OXYGEN CONCENTRATOR USER MANUAL
8
CHECK PACKAGE AND PACKING LIST
When you receive the product, please open the package carefully. This
product is equipped with upper and lower foam protection cover, such as
the protective cover is damaged, please immediately check whether the
product is damaged or not. Then, check if there are any missing parts or
accessories in the inspection of the packing list of the products.
Packing List
Number Product /Component Name Quantity Unit
1 Oxygen Concentrator 1 Unit
2 Humidification Bottle 1 Piece
3 Nasal Oxygen Tube 1 Piece
4 Air intake flitering foam 1 Piece
5 User Manual 1 Piece
PRODUCT OPERATING PROCEDURE
1、The tie on the bottom of the machine need to be cut off before
boot. The machine back need to be far from the wall at least 30
cm, must be the bottom of the bubble board and other things to
get open, to ensure that the bottom of the stack, in order to
maintain the bottom of the air flow and ensure the normal heat.
2、Connect the humidifaction bottle and operate it as following
instrustion:

OXYGEN CONCENTRATOR USER MANUAL
9
a. Put into the distilled water as the water level instructions.Fix the
cover to the body (Figure 1);
b. Screw the humidifer into the oxygen outlet by counterclockwise. Since
the humidifer is hanging, make sure it is securely screwed onto the outlet
port (see Figure 2).
Notice:The best installation place as figure 2
3、Remove the AC power line from the retaining strip, confirm the sw
itch in the off position. Insert the plug into the indoor power
outlet at this time.
4、Medical oxygen concentrator with the equipment to monitor
Highest Water Level
Lowest Water Level
Fix the humidifer by screw,
please take off when don’t
use
(Figure1)
(Figure 2)
Safety Valve(Inside)
Intake Air Connector
Oxygen Exit
Bottle Body

OXYGEN CONCENTRATOR USER MANUAL
10
the purity .When the machine is on,the instruction light will shin for
three time. Several minuates later,
the yellow low oxygen purity alarm
light will got,leaving the power supply and normal light shinning.
5、 According to the output flow, the flow control knob is turned clock
wise to adjust the large flow rate and turn clockwise to turn down
the flow.
6、 Put the nasal oxygen tube intake air
connector to the air exit of the bottle ,
and then put the nasal tube to the
user’ ears, insert the nasal plug in the
oxygen inhalation tube and to the nostrils
of the oxygen inhalation person tomake the
oxygen inhalation. Like Figure 3:
7、When the machine is running, if the alarm is sounded, please
check whether the power supply connection is loose or not, or
whether the external power supply has been interrupted.
8、When oxygen is finished, please turn off the power switch. Accordi
ng to the prompt cleaning oxygen inhalation tube or oxygen mask.
Do not often use, please dial the power plug, the AC power line
with the fuselage drawstring tie, and put the machine in place.
(Figure 3)

OXYGEN CONCENTRATOR USER MANUAL
11
PRODUCTION INTRODUCTION
Oxygen concentrator refers to an oxygen concentrator used at home,
nursing homes or patient care center to provide low flow oxygen therapy. Our
oxygen generator product is adopted the pressure swing adsorption principle,
air pressure and pressure, after the molecular sieve nitrogen and oxygen
molecules in the air separation, oxygen retention, nitrogen discharge. When
the power is switched on at room temperature, the oxygen in the air can be
separated from the air to meet the medical standard.
STRUCTUR
This product is composed of the machine body, flowmeter,
humidification bottle, nasal oxygen tube or oxygen mask.
SCOPE OF APPLICATION
The equipment is mainly suitable for the preparation of medical oxygen.
CONTRINDICATION
Non
ENVIRONMENT REQUIREMENT
1. Environmental Temperature:5℃~40℃;
2. Relative Humidity:≤ 80%;

OXYGEN CONCENTRATOR USER MANUAL
12
3. Atmospheric Pressure:86 kPa~106 kPa ;
4. No corrosive gas and strong magnetic field in the surrounding
environment.
TRANSPORTATION AND STORAGE CONDITIONS
1.Range of Environmental Temperature:- 20℃~+55℃;
2.Range of Relative Humidity :≤ 93% ;without no condensation
phenomenon;
3.Range of atmospheric Pressure:50 kPa~106 kPa.
Notice:When the storge temperature is under 5℃,it
should beput the machine under the normal temperature
environment for over four hours before use it.
ADDITIONAL REMARKS
Classification of protection against electric shock:Class II
Classification according to the degree of protection against electric
shock:Class BF
Classification according to the degree of protection of the liquid into
the machine:IP21 Device;
According to the degree of safety classification used in flammable
anaesthetic mixture with air or oxygen or Nitrous Oxide anaesthetic mixture
case: when do not use of flammable gas and air mixed with oxygen or Nitrous
Oxide or anaesthetic mixture under the condition of the equipment;

OXYGEN CONCENTRATOR USER MANUAL
13
classification according to the operation mode:Continuous operation;
No signal output and signal input part;
Usage Voltage:230V~、50Hz;
Working:Continuous working;
With the application of oxygen free discharge part of the protective
effect of defibrillation;
Oxygen Concentrator is for non permanent installation equipment.
*Altitude: 0 meter to 2000 meter,oxygen purity ≥90%,
2001 meter to 4000 meter, ≤90%
PURITY VALUE AND FLOW FUNTIONS CHART
CP101 output pressure=0,Purity and value flow funtions chart(Figure 4)
Figure 4

OXYGEN CONCENTRATOR USER MANUAL
14
TECHNICAL PARAMETERS
Model CP101
Working Voltage 230 V~± 10% / 50 Hz ± 1 Hz
Rated Power (VA)770
Output Pressure=0/7kPa,
the flow range(L/min)1~10
Output Pressure=0,the
purity value(within 10min,
up to the standard)
Oxygen flow=1~10 L/min,purity≥90%
Highest Flow 10 L/min
Highest Flow with 7kPa
pressure,change of flow ≤1 L/min
Highest Flow, purity(within
10min,up to the standard)≥90%
Range of adusting flow 0~10L/min adusted continously
Net Weight(Kg)20.5
Noise dB(A) ≤55
Dimension(mm)L400 × W300 × H540
Oxygen output pressure 60kPa-80kPa
Yellow low oxygen indicator
light
When 72%≤purity≤82%,the yellow indicator will
shin,contact the supplier, Make sure have the spare
oxygen nearby when use it continously.
Red alarm indicator light
When purity ≤72%,red indicator will alarm,and
dispaly show Lo-o2.It will stop within one minute.Please
turn off at once and choose the spare oxygen , contact
the supplier

OXYGEN CONCENTRATOR USER MANUAL
15
Compressor safety valve release pressure:250kPa±50 kPa
Oxygen output temperature:≤46℃
COMPONENTS NAME AND FUNTIONS
DESCRIPTION
* The following Component description refer to figure 5, figure6 *
1. Oxygen outlet:Connect to the humidified bottle or nasal oxygen tube by
connecting tube
2. Product nameplate / serial number label: product performance, product
serial number
3. Air intake flitering foam:To prevent dirt, dust, fibers into the machine
4. Heat sink :On the bottom of the machine, the equipment can not be
blocked at work
5. Straight out of the AC power cord (with plug)
6. Castor (4): flexible mobile machine
(Figure5) (Figure 6)
1
5
6
2
3
4

OXYGEN CONCENTRATOR USER MANUAL
16
7. Resettable current overload protector
8. Power switch:O/I
9. Oxygen flow meter ( Figure 7)
a. The position of the flow knot in the oxygen flow meter indicates the size
of the flow.(L/min)
b. Flow adjusted valve:
on/off button on the flow meter,
adjust and control
the flow of output oxygen.
Notice :Test the oxygen flow meter and make sure the knot in the
regular tick mark(CP101 Max flow 5L/ min,do not let the knot over
5liter).
The oxygen flow is so important so do not add or down the flow, just
refer to the flow the doctor required.
Flow will be reduced if the flow meter is rotated clockwise. (Will
eventually shut down the flow of oxygen), If the counter clockwise rotation,
the flow will increase.
9b
9a
7
8
Figure 7
10

OXYGEN CONCENTRATOR USER MANUAL
17
* The following parts are illustrated with reference to Figure 8 *
10.LED Display(Reference figure 8)11a 11b 11c 11d
a. Green power indicator light-Start operating
b. Green indicator light-Oxygen output normally
c. Green indicator light-Low Purity
d. Red indicator light-Contact the manufacturer
e. Digital display slot:
Cumulative timing:Digital show
Fault code description:
Show Lo-o2─cycle fault alarm or purity≤72%
Show Lo-P─low pressure alarm
Show Lo- Po2─cycle fault and low pressure alarm
Show Hi-P─High pressure alarm
Show Hi-Po2─cycle fault and high pressure alarm
Note:
Machine have the following self-test funtions:
Low purity,
cycle
faultor purity≤72% alarm,low pressure alarm,
cycle fault and low pressure alarm,
High pressure alarm,
cycle fault and
high pressure alarm
When working normally, fault monitoring function oxygen machine will
monitor the working state of oxygen making machine ,When 72% ≤
purity≤82%,yellow low oxygen indicator light shinning ;If purity≤
72%,red alarm light shinning with continous alarm sound.
When show Lo-o2,
the machine will stop within 1min,
please turn off
the machine immedicately;When the machie show the low pressure,
the red light will shin with continous alarm sound.
(Figure 8)
11e

OXYGEN CONCENTRATOR USER MANUAL
18
Note:All the alarm state of the oxygen making machine belongs to the
low priority. The alarm system have been set up in the factory, the user
cannot change the alarm system settings.
CLEANING AND MAINTENANCE INSTRUCTIONS
1、Clean the outside shell:one~twice each month.Please cut off the power
supply situation, use a wet towel to clean the exterior of the soft with a
little detergent wipe, then dry towel to dry.
2、Clean the humidification bottle:You can use detergent and hot water to
clean the humidification bottle separately, or with white vinegar with
water at the ratio of 1:3 mixture of fungicides, 30 minutes in the
humidification bottle after the separation of the solution, and then dry
the wet bottle.
3、Clean the Air intake flitering foam:take off the cotton on the back side of
the box,clean it with detergent and rinse thoroughly with clear wate. Dry
in the air. If do not dry thoroughly ,please don”t use it.This is the
important step for protect the machine. It is advised twice each month.
WARRANTY
1、From the date of purchase 2 years or 15000 hours (to the expiration
of the time cut-off point) for the quality assurance period, such as
the product is not for the normal operation of non-human,
manufacturing plants should provide with free service for the user
to repair or replace parts.
Table of contents
Popular Medical Equipment manuals by other brands

medi
medi circaid juxtafit essentials lower leg inelastic compression... manual

NanoVibronix
NanoVibronix PainShield quick guide

idi
idi Aspect 100UC Plus Q-CARD Operator's manual

Acclaim Lighting
Acclaim Lighting A5500 Operator's manual

Basko
Basko MultiMotion Series instructions

Organ recovery systems
Organ recovery systems LifePort Kidney Transporter Operator's manual