5612272-UTG-H-1221
Johnson Controls Ducted Systems 3
‡ The adapter fitting must be field installed for the required 1 1/8 in. refrigeration pip-
ing.
Notes:
• All dimensions are in inches and are subject to change without notice.
• The overall height is from the bottom of the base pan to the top of fan
guard.
• The overall length and width include screw heads.
PHYSICAL AND ELECTRICAL DATA
Model RHP14L18B
23S RHP14L24B
23S RHP14L30B
23S RHP14L35B
23S RHP14L36B
23S RHP14L42B
24S RHP14L48B
23S RHP14L60B
23S
Unit supply voltage 208 V to 230 V, 1 60 Hz
Normal voltage range1(V)
1. Rated in accordance with AHRI Standard 110-2012, utilization range A.
187 V to 252 V
Minimum circuit ampacity (A) 12.0 15.4 18.1 20.5 22.0 26.8 30.8 31.7
Maximum overcurrent device (A)2
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
20 25 30 35 35 45 50 50
Minimum overcurrent device (A)3
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
15 20 20 25 25 30 35 35
Compressor Type4
4. Rotary compressor models are limited to an equivalent length of refrigeration piping of 100 ft with no exceptions.
Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll
Rated load (A) 9.0 11.7 13.4 15.4 15.4 19.2 23.6 24.3
Locked rotor (A) 56.3 61.6 72.5 83.9 83.9 123.9 130 144.2
Crankcase heater No No No No No No No No
Factory external discharge muffler Yes Yes Yes Yes Yes Yes Yes Yes
Hard start kit required with TXV5
5. Refer to the Hard Start Kit Accessory Installation Manual for the hard start kit part number for each model. The hard start kit is a field installed accessory.
No No No No No No No No
Hard start kit part number
(S1-2SA067*****) 10106 10106 10106 10106 10106 10106 10106 10106
Fan diameter (in.) 22 22 24 24 26 26 26 26
Fan motor
Type PSC PSC PSC PSC ECM ECM PSC PSC
Rated HP 1/8 1/8 1/4 1/4 1/3 1/3 1/4 1/4
Rated load (A) 0.80 0.80 1.30 1.30 2.8 2.8 1.30 1.30
Nominal RPM 1075 1075 850 850 834 834 850 850
Nominal CFM 2850 2850 2995 2995 3715 4000 4000 4100
Coil Face area (sq ft) 16.15 17.94 23.82 23.82 26.40 26.40 26.40 28.80
Rows deep 1 1 1 1 1 1 2 2
Fins per inch 22 22 22 22 22 22 18 18
Liquid refrigeration piping outdoor (field
installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Vapor refrigeration piping outdoor (field
Installed)6
6. For applications with non-standard vapor line sizes, see the APPLICATIONS AND ACCESSORIES section.
3/4 3/4 3/4 3/4 3/4 7/8 7/8 1 1/8‡
Unit charge (lb - oz)7
7. The unit charge is correct for the outdoor unit, smallest matched indoor unit, and 15 ft of refrigerant tubing. For tubing lengths other than 15 ft, add or subtract refrigerant, using the
difference in actual refrigeration piping length multiplied by the per foot value.
‡ The adapter fitting must be field installed for the required 1 1/8 in. refrigeration piping.
5 - 3 5 - 6 6 - 12 8 - 1 8 - 15 8 - 11 13 - 3 13 - 13
Charge (oz/ft) 0.62 0.62 0.62 0.62 0.62 0.67 0.67 0.75
Operating weight (lb) 120 131 176 176 230 230 235 256
&
%
$
$
DIMENSIONS
Unit
model
Dimensions
(in.) Refrigerant connection
service valve size (in.)
A B C Liquid Vapor
RHP14L18B23S 33 1/4 29 1/4 29 1/4
3/8
3/4
RHP14L24B23S 36 1/4 29 1/4 29 1/4
RHP14L30B23S 39 1/2 35 1/4 31 3/4
RHP14L35B23S 39 1/2 35 1/4 31 3/4
RHP14L36B23S 39 1/2 38 34 1/4
RHP14L42B24S 39 1/2 38 34 1/4 7/8
RHP14L48B23S 39 1/2 38 34 1/4
RHP14L60B23S 42 3/4 38 34 1/4 7/8‡