manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. YOSensi
  6. •
  7. Measuring Instrument
  8. •
  9. YOSensi YO People Counter User manual

YOSensi YO People Counter User manual

Other manuals for YO People Counter

1

Other YOSensi Measuring Instrument manuals

YOSensi YO Distance User manual

YOSensi

YOSensi YO Distance User manual

YOSensi YO Pulse User manual

YOSensi

YOSensi YO Pulse User manual

YOSensi Airflow Pro2 User manual

YOSensi

YOSensi Airflow Pro2 User manual

YOSensi YO 360 User manual

YOSensi

YOSensi YO 360 User manual

YOSensi YO Analog User manual

YOSensi

YOSensi YO Analog User manual

YOSensi YO Temp User manual

YOSensi

YOSensi YO Temp User manual

YOSensi YO Power User manual

YOSensi

YOSensi YO Power User manual

YOSensi YO Meter Pulse User manual

YOSensi

YOSensi YO Meter Pulse User manual

YOSensi YO Ambience User manual

YOSensi

YOSensi YO Ambience User manual

YOSensi YO Analog User manual

YOSensi

YOSensi YO Analog User manual

YOSensi YO Power User manual

YOSensi

YOSensi YO Power User manual

YOSensi YO Power User manual

YOSensi

YOSensi YO Power User manual

YOSensi YO AgriBox User manual

YOSensi

YOSensi YO AgriBox User manual

YOSensi Airflow Pro2 User manual

YOSensi

YOSensi Airflow Pro2 User manual

YOSensi YO Airflow Pro User manual

YOSensi

YOSensi YO Airflow Pro User manual

YOSensi YO H2O User manual

YOSensi

YOSensi YO H2O User manual

YOSensi YO Refrigerant Monitor User manual

YOSensi

YOSensi YO Refrigerant Monitor User manual

YOSensi YO Pure Pro User manual

YOSensi

YOSensi YO Pure Pro User manual

YOSensi YO People Counter User manual

YOSensi

YOSensi YO People Counter User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1. Important! Figure 1 shows the direction, this must be taken into account when mounting
the device.
Figure 1 Opening the enclosure of the device.
1
2. To open the enclosure, peel off the lower part, as shown in Figure 2.
Figure 2 Opening the enclosure of the device.
2
3. YO People Counter can be powered in via USB-C connector, via power supply 6-30 DC or
5-21 AC. There are two ways to connect the device to the power supply.
A. The user must break the centre plastic circle labelled PUSH out of the mounting
bracket before installation. After that, route the cable through the centre hole of
the bracket.
Figure 3 Breaking out the plastic circle labelled PUSH.
Figure 4 Routing power supply connector through the centre hole.
3
Figure 5 Routing the USB-C cable through the centre hole.
B. The second option is routing the wire through the hole in the mounting bracket.
You can route the USB-C cable or AC/DC power supply depending on the supply
you need.
Figure 6 Routing the USB-C cable through the hole in the bottom of the device.
4
Figure 7 Routing the power supply cable through the hole in the bottom of the device.
Figure 8 Bottom view of the device after connecting the supply via the bottom hole.
5
3. There are two ways to mount the device into a wall.
A. Install the bottom part of the enclosure and mount four screws in each corner to
the wall.
Figure 9 Mounting the device using four screws.
B. Fit two mounting screws into the centre of the bottom case. Then, angle the
bottom of the enclosure and turn it clockwise.
Figure 10 Mounting the device using two screws at an angle.
6
Figure 11 Mounting the device using two screws after a clockwise turn.
Remember to route the supply cable through the centre of the bottom enclosure before mounting it
to the ceiling or a wall.
4. Place the upper part of the device enclosure on the bottom part mounted on a wall.
Figure 12 Placing the top of the enclosure on the mounting bracket.
7