Youha INS GEN 2 User manual

THE INSGEN 2
Breast Pump
Instruction for use
Version 1.2
more care for mama & baby

We hope THE INS GEN 2 breast pump supports you in a
THE INS GEN 2
Breast Pump
Offering hands-free, more enjoyable and discreet way to
express breastmilk. THE INs GEN 2 breast pump is designed
to use anytime you like, wherever you like. It is small and
lightweight to place inside your bra.
THE INS GEN 2 breast pump provide a mobile pumping
method that maintains the quality and effectiveness of a
non-mobile way, allowing you to express quickly and
efficiently at your convenience. Assembly is simple and
straight forward; all parts can be disassembled to enable
easy cleaning and can be sanitised in boiling water.
No tubes, no cords, no dangling bottles
No more pumping schedule
Pump anywhere anytime as you want to
All-in-one device. Easy to assemble and clean
Made with food grade plastic and silicone, BPA free, Phthalate
free
Safe, convenient, effective.
THE Ins GEN 2 breast pump is a closed system with a breast
shield made from food-grade, frosted silicone, for your
comfort and safety.
better breastfeeding experience!
We love to hear from you! If you have feedback or wish to
share your breastfeeding story with us, please send us an

Important information
Table of Contents
1
Important information 1
Product description 2
Cleaning
Before first use 3
After each use 3
How to sanitise 3
Pump operation
Pump Control Panel 4
Battery indicator 5
Instructions for use
How to assemble 6
Placement in bra 7
Turn off the pump before remove from breast 8
Postures for expressing 9
Troubleshooting 10
Technical data 11
Please do not unofficial adapter.
Please switch off the breast pump before you remove the pump
body from your breast.
Please do not clean or sterilize pump body and adapter.
If milk flow a little bit, please consult doctor and breastfeeding
advisor.
Do not continue pumping for more than five minutes at a time
if you do not succeed in expressing any milk.
If using a breast pump causes pain, please consult
breastfeeding advisor or doctor.
Never use the breast pump while you are pregnant, as
pumping can induce labour.
Wash your hands with soap and water and dry thoroughly
before assembling parts before expressing.
Avoid harsh detergents or hard scourers sponges as this may
scratch or damage the product.
Store in a cool, dry space and avoid direct sunlight.
Replace the parts or the product if it shows signs of wear or
damage.
Replace the valves every month (1 spare valve is provided).
Please do not use a cleaning brush inside the valve as this may
damage the valve or shorten its lifespan.
It is only intended for use by a single user, do not share with
others.
Ensure you use correct size of breast shield.
Do not allow children to play with small parts, these parts may
pose a choking danger.

Cleaning
Product description
2
3
1 x Dust cap
1 x Charger
1 x Pump
1 x Membrane
1. Before first use
a. Disassemble all parts
b. Wash in warm soapy water
c. Rinse well
d. Submerge parts in pot of water and boil for 3-5 minutes
i.
Use large pot to avoid parts touching sides or bottom of
pot
e. Shake off excess water and air dry on a dedicated rack
or clean cloth
2. After each use
a. Disassemble all other parts (membrane, collection cup,
silicone breast shield and valve)
b. Rinse with cold water soon after use
c. Wash in warm soapy water
i.
Valves can be cleaned by gentle rubbing between fingers
d. Rinse well
e. Shake off excess water and air dry on a dedicated rack
or clean cloth
1 x 24mm Silicone breast shield
1 x 28mm Silicone breast shield
2 x Valves
1 x 5oz/150ml Cup
3. How to sanitise
a. Follow cleaning instructions 2.a through 2.e
b. Submerge parts in pot of water and boil for 3-5 minutes
i.
Use large pot to avoid parts touching sides or bottom of
pot
c. Shake off excess water and air dry on a dedicated rack or
clean cloth

Pump operation
Pump operation
4
5
Pump Control Panel Battery indicator
a On/Off button / Mode button
b b Increase vacuum
c c Reduce vacuum
Red light = massage mode
Blue light = express mode
Purple light = mixed mode
a
Using the breast pump
Long press “ ” turn on (Show battery indicator)
Long press “ ” turn off (Show battery indicator)
The breast pump automatically starts up in massage mode for 2 minutes,
then change to express or mixed mode and shut down after 30 minutes
Press “”change different modes
Quiet Function: While the pump is on, double-click the on/off button to
activate the Quiet Function. Double-click again to turn Quiet Function off .
Note: When in Quiet Function the light appears darker to indicate the
function is on.
Each mode is 10 levels
Massage mode, press + or - , increase or reduce vacuum
Express mode, press + or - , increase or reduce vacuum
Mixed mode, press + or - , more or less frequency of massage
Press + or - , indication light once flashing, it means change successfully
If the light keeps flashing, it means it is the lowest or highest level
Each time the pump is switched on and off, the battery indicator will flash
once, indicating the remaining battery power
When the battery indicator flashes green and stops blinking, the battery is
fully charged
Note:
1.Do not worry if your milk does not flow immediately. Relax and continue
pumping.
2.Do not continue pumping for more than 5 minutes at a time if you do not
succeed in expressing any milk. Try to express at another time during the
day.
3.You do not need to use all suction modes, only use the modes that are
comfortable for you.
4. Pump is preset to turn off on 30 minutes.
Note: In mixed mode, the suction and cycyle is the same level with
massage and express mode, so you may adjust the level which fits for
you before change to mixed mode
Green
Battery 31%-100%
Orange
Battery 11%-30%
Red
Battery 4%-10%
Red light blinking
Battery 1%-4%
Attention: Battery can not be charged over 24 hours,
otherwise it will be damaged easily.

Instructions for use
Instructions for use
How to assemble
How to assemble
6
7
1
2
Placement in bra
1
2
3

Instructions for use
Instructions for use
Placement in bra
Postures for expressing
8
9
MAY LEAK
Reclining back
WON'T WORK
Laying back (or side)
Turn off the pump before remove from breast
IDEAL
Upright
GOOD
Slightly forward
OK
Bending forward

Troubleshooting
Technical data
10
11
1. Power adapter input: 1 00-240V~ 50/60Hz
2. Power adapter output: 5V 1000mA
3. Nomina l voltage: 5V
4. Rated current: 1000mA
5. Lithium battery: 3.7V,1200mAh
6. Product life: 1.5 Years
7. Fixed time: 30 minutes
8. Sucking power: 60mmhg--300mmhg
9. Noise limite d: <60dB
10. Environmental Conditions for Operation: 10-30 ,
RH15%-93%,700-1060hpa
11. Environmental Conditions Storage: -25-50 ,
RH15%-93%,700-1060hPa
Power In / Power Out Vacuum Rage (approx.)
60-300 mmHg
In
Out
100-240V~ 50/60 Hz
5V
1A
Battery Capacity and Type
3.7V 1200mAh
Li-Ion
Product Net Weight
246 g
Issue
Solution
Unable to
Express Milk
Make sure the suction is sufficient and the
assembling of breast pump is quite correct.
Relax and retry it, milk will be expressed
after repeat trials.
Low or no
suction
Ensure the valves are in the correct position
and check for any damage or wear. Replace
valve if needed.
Check that all parts are securely assembled.
Nipple pain
Seek advice from a Lactation Consultant.