Youha The INs User manual

Instructions for use
wherever motherhood takes you
Version 1.0
(Material Code)

THE INS breast pump empowers you to go
wherever motherhood takes you.
We hope the THE INS breast pump supports you in a better
breastfeeding experience.
We would love to hear from you! If you have feedback or would like to
share your breastfeeding story with us, please send us an email at:
THE INS breast pump is a high-quality, closedsystem.
All parts that come in contact with breast milk are made with
food grade plastic and silicone.
•Sleek and compact design
• Quiet and convenient operation
• Fully supported App controls and secure tracking*
• All-in-one device, easy to assemble and clean
• No tubes, no cords, no dangling bottles
• Comfortable silicone breast shield
• Safe, convenient and effective breast milk expression
• Ideal for use at home, at the office or wherever you like
The ultimate in control and convenience, THE INS breast pump
frees you from tubes, wires and fuss!
•at home: playing with children, taking care of daily routine
• at work: in meetings, at the desk
• outdoors: family time, relaxing in nature, gentle exercise
• in transit: walking, driving, flying
• at celebrations: gatherings, celebrations, weddings
Safe, convenient, effective.
Ph tha late
FREE
FoodG rade Si licon e
S
VC
*Connect your THE INS breast pump to
control remotely and securely track your
breast milk through the My YOUHA app.

Important information
Taking care and safe use of your Youha THE INS breast
pump product
(continued)
Use of UV sterilisers is not recommended as it will yellow the
silicone parts and shorten the lifespan of the parts or possibly
damage them.
Do not use a cleaning brush inside the valves as this may
damage the valve or shorten its lifespan.
Replace the valves at first signs of wear, if damaged or after
every 2-4 weeks of use to maintain optimal effectiveness of
your pump (1 pair of spare valves are included).
Replace all other pump parts at first signs of wear, if damaged
or after every 2-6 months.
Store all parts in a cool, dry space and avoid direct sunlight.
Do not clean, sterilise or submerge pump motor unit and / or
charging cable.
Only use 5V / 1-3A charger with USB Type-C cable to
recharge battery in motor unit.
Do not leave the motor unit on charge for longer than 24
hours as this may damage the battery permanently and/or
cause a safety risk.
Keep this product out of reach of children at all times. This
product contains small parts which may be a choking hazard.
5
Important information
4
Preparation is important
Wash your hands with soap and water and dry them
thoroughly before assembling parts for expressing.
Ensure all parts of the pump are clean and dry before
each use.
Taking care and safe use of your Youha THE INS breast
pump product
This product is a personal care item and use should not be
shared between mothers.
Do not use the breast pump while you are pregnant, as
pumping may induce labor.
Ensure you are fitted with the correct size of breast shield. If
you experience any discomfort or pain while using your THE
INS breast pump, seek professional advice from a Lactation
Consultant to ensure you have the best fitting breast shield for
you.
Do not continue pumping for more than five minutes at a time
if you do not succeed in expressing any milk.
Always switch off the breast pump before you remove the
pump from your breast.
Avoid harsh detergents or hard scourers and sponges as this
may scratch or damage the product. Exposure to detergent
may make the silicone appear cloudy over time.

Table of Contents
7
Product description
6
Important information 4
Breast shield sizing information 13
Product description 7
Cleaning
Before first use/to sanitise
After each use
8
9
Pump operation
Pump control panel 10
Battery indicator 12
How to use the control panels 11
Technical specifications and considerations 12
How to assemble
Placement in bra
Postures for expressing
How to remove the pump and pour breast milk
Instructions for use
14
15
16
17
Troubleshooting 18
Warranty and contact details 19
Motor unit

Before first use/to sanitise*
After each use
89
Cleaning
Cleaning
Important: the Valves are delicate and can be damaged
easily. For this reason, avoid inserting cleaning brushes
into them. Please handle them with care and replace
them frequently.
*Electric steam, microwave sterilisers are also suitable
methods. However, UV sterilisers are not recommended
as the silicone parts will yellow and it will shorten the
lifespan of the parts.
a. Disassemble all parts.
b. Set aside the Motor units and cables. These do not
come into contact with milk and should never washed or
submerged in water.
c. Rinse U membranes, Cups, Silicone breast shields
and Valves with cold water to remove breast milk
soon after use.
d. Wash U membranes, Cups, Silicone breast shields
and Valves in warm soapy water and rinse well with clean
water. Valves can be cleaned by gently rubbing them
between your fingers.
e. Shake off excess water and air dry on a dedicated
rack or clean cloth.
a. Disassemble all parts.
b. Set aside the Motor Units and Cables. These do not come
into contact with milk and should never washed or submerged
in water.
c. Wash U membranes, Cups, Silicone breast shields and
Valves in warm soapy water and rinse well in clean water.
d. To sterilise, submerge parts in a large saucepan of water,
and boil for 3-5 minutes. Avoid parts touching the sides or the
bottom of the saucepan, or being in sustained contact with other
parts, by gently stirring.
e. Use tongs to remove parts from the hot water, gently
shake off any excess water once cool and air dry on a dedicated
rack or clean cloth.
When necessary, wipe the motor unit or charger with a soft,
damp cloth while the motor unit is off and the charger is
unplugged from any power outlet. Clean and sanitise all other
parts of the pump, which come in contact with breast milk, prior
to first use and after each subsequent use.

Pump operation
11
Pump operation
Pump control panel
10
My YOUHA app control panel
Previous screen
Stopwatch
Dual control
Battery indicator
Mixed Mode
Quiet Mode
Level
(Reduce/Increase)
Pumping record
On/Off
Express
Massage
Start/Pause
Menu
A long press “ ” will turn the pump on or off. At these times the
battery indicator light will flash to indicate the current level.
The breast pump automatically starts up in Massage mode for 2
minutes, then automatically changes to Express or Mixed Mode
(whichever was in use when the pump was last turned off). You can
override this two minute massage preset by pressing “ ” or by
selecting one of the modes in the My YOUHA app, whenever you
feel ready (when you feel the letdown or when milk is flowing).
Press “ ” to change between Massage, Express and Mixed Mode or
simply select the mode via the My YOUHA app. Each mode has 10
levels. In Massage or Express mode, press + or - to increase or
reduce the vacuum strength and cycle speed simultaneously.
When pressing + or - , the indicator light will flash once, to denote a
successful change of level. If the light keeps flashing, it means it
has reached the lowest or highest level.
Mixed Mode adds cycles of massage mode in between each express
cycle. In mixed mode, press + or - , to increase or decrease the
frequency of massage. In mixed mode, the respective massage and
express strengths stay at their previously selected level.
To activate or deactivate the Quiet function, double-click “ ” or turn
on via the My YOUHA app while the pump is in operation. When the
Quiet Function is activated the “ ” light appears dimmer to indicate
the function is on. Note: the Quiet function will reduce the strength
of your pump while active.
An inbuilt timer will shut the pump off after 30 minutes of operation.
How to use the control panels

13
Pump operation
Battery 31% - 100%
Battery 11% - 30%
Battery 1% - 10%
Battery indicator
Green
Orange
Red
Each time the pump is switched on or off, the battery indicator ( )
will flash once, indicating the remaining battery power. When charging,
once the battery indicator light is green and unblinking, the battery
is fully charged.
To extend the life of your battery and avoid damage do not charge for
longer than 24 hours.
To charge your THE INS breast pump, and avoid damage to the
battery, only attach your Type-C USB cable to a charger with a
voltage of 5V and a current between 1A and 3A. Most phone
chargers, tablet chargers and power banks can be used to charge
THE INS breast pump.
When connected to the My YOUHA app, the battery symbol will
indicate the remaining battery level of each pump.
Nipple
sizes
upto:
Breast
Shield/
Convertor
Size:
Suggested size to begin:
16mm 18 Size 24 breast shield, plus size 18 convertor
(sold separately)
18mm 20 Size24breastshield, plussize20convertor
(soldseparately)
20mm 22
22mm
24 Size24breastshield
24mm 26
Size28breastshield
26mm 28
Size24breastshield, plussize22convertor
(included with 24mm cups)
Size28breastshield, plussize26convertor
(included with 28mm cups)
To identify the suggested breast shield
size to begin with, stimulate your nipple
so that it stands up and measure the
diameter (or width) of the nipple base.
Do not include the areola.
Measure the nipple before a
pumping session. If you measure
during pregnancy, it is important
to measure again prior to beginning
pumping as nipple size can change
slightly following childbirth.
A good fit breast shield is important for both comfort and safety, as well as
the efficiency of the pump. The suggested size to begin with is
approximately 2-3 mm larger than the base of the nipple diameter.
Other factors include how it feels and if there is any discomfort or pain.
The pump should pull into the breast shield all of the nipple but none or
very little of the areola. If there is rubbing on the areola, the breast shield
size is likely too large. If there is rubbing on the nipple, the breast shield
size is likely too small.
If you have concerns or are unsure, it is important to seek advice from
a professional such as a Lactation Consultant.
Breast shield sizing information
Technical Specifications and considerations
VacuumStrength 60‒300mmHg
BatteryCapacity
andType
3.7V1100mAh
Li-ion
Motor Unit Size 79.78x67.83x43.37mm
Motor Unit Weight 139.5g
MaximumCharging
Voltage
5V
(Voltages other than 5V will
damage the battery)
MaximumCharging
Current
1A-3A
(Currentsoutsideofthese
limitswilldamagebattery)
12
How to measure and find your breast shield size
Areola
Nipple
Nipple base
Measure

Instructions for use
15
14
Instructions for use

Instructions for use Instructions for use
17
16
Postures for expressing
IDEAL
Upright
GOOD
MAY LEAK
Slightly forward
OK
Bending forward
Reclining back
WON'T WORK
Laying back (or side)

18
Troubleshooting
Issue Solution
Warranty
THE INS breast pump has a 12-month warranty from the time of
purchase on product faults. The proof of purchase or invoice will
be required to validate any warranty claim.
Warranty does not include damage or malfunctions caused by user
error or non-compliance with instructions.
Please contact your local Youha distributor for further warranty
information or if you wish to order replacement parts.
Warranty and contact details
19
Check valve position and whether securely
sealed in place. Check condition of valve
and replace if worn. Install spare valves
provided if not yet used. Check sizing
suggestions for breast shield/convertor
selection on Page 13.
Check sizing recommendations for breast
shield/convertor selection on Page 13. Seek
advice from your lactation consultant.
Ineffective/
inefficient
expression
Nipple areola/
pain
Breast milk
leaking onto
breast
Check appropriate postures for expressing,
see Page 17.
If occurring on removal of cup from the bra,
ensure you lean slightly forward on
removal, see Page 16.
Table of contents