YSmart Technology IP Series Grid Tie inverter User manual

IP Series Grid Tie inverter
1
Contact Us
Address: No. 30 XinFeng Road,Potoubei Village,Ailian Town,Longgang Dist,
Shenzhen 51872,P.R. China
Tel: (86)755-85232255 Fax: (86)755-85232255
Website: http://www.ysmart-tech.com http://www.chinasolarregulator.com
User Manual
IP Series Inverters for Grid-connected PV system
YSmart Technology Co., Ltd.

IP Series Grid Tie inverter
2
Product Warranty Card(Invalid Duplicate)
Customer Feedback:
Name
Country and/or Territory
Telephone
Email
Purchase Channels and/or
Sources
Models
Date of Purchase
Date of Installation
Time of Using
Brief Fault Description
Improvement Suggestions
Distributor and/or Sales Representative
Distributor Name
Telephone and/or
Email
Sales Representative Date of Customer
Feedback
Date of finish
Disposal
Disposal
YSmart QC Technician
Others
YSmart micro grid inverter can be used at below situations;
1.Work with 72cell solar panel(Vmp:36V,Voc:43V)
2.Work with wind turbine,if the wind trbine do not build in wind charge
controller,need add wind charge controller
3.work with battery,you can use solar and wind to charge the battery,and the
battery release the power to the grid thr inverter
YSmart Smart Microinverter Introduction

IP Series Grid Tie inverter
3
Grid tie inverter is a device which directly converts direct current into sine wave,
frequency and phase are same as power grid alternating current and feed into power grid. It
is a key device of power generation system such as PV power generation system, small
power wind power generation system. YSmart Smart Microinverter optimized design for
modularization modular power generation systems. They can use with DC power source
such as the mainstream solar module such as 18V, 24V and 36V monocrystal and/or
Polycrystalline solar panels, small power wind generator as well as battery for converting
into alternating current which suitable for feeding into utility grid. Product is stable and
reliable as well as high conversion efficiency. It is best choice for PV power generation
systems and small power wind power generation systems.
YSmart Smart Microinverter can be easy placed and attached to the rack of solar panels. No
need space for independent installation and low voltage DC wire of side of solar panel
connecting to Smart Microinverter can eliminate the risk of high DC voltage which cause
of high power centralized inverter’s series string and/or parallel connections. Distributed
modularization design philosophy for YSmart Smart Microinverter will ensure the
productiveness of the whole system will not affect by a single point of failure. Each Smart
Microinverter is individually connected to one PV module in your array. This unique
configuration means that an individual Maximum Peak Power Point Tracker (MPPT)
controls each PV module. This ensures that the maximum power available from each PV
module is exported to the utility grid regardless of the performance of the other PV modules
in the array. That is, although individual PV modules in the array may be affected by
shading, soiling, orientation, or PV module mismatch, the Smart Microinverter ensures top
performance for its associated PV module. The result is maximum energy production from
your PV system and gets return on investment in less time.
Advantages of YSmart Smart Microinverter
1. Unique circuit design, choice of import industrial electronic components, higher
efficiency, more stable performance.
2. Creative MPPT technology, efficiency more than 99%, faster reaction, more sensitive of
reaction and more reliable of Maximum power point locking.
3. Parallel modular design, small volume, distributed installation, easy for system
configuration, flexible for combination, strong expansibility of system.
Warranty
Warranty Conditions
Warranty Period: 15-year limited warranty period.
Warranty Time Start: From the date of bill of lading.
Warranty Evidence: The bill of lading date, product(s) serial number(s), and
product(s) model number(s), and a completed warranty card.
YSmart grants an implied warranty of 1 year to the inverter from date of purchase
for repair or replace the Defective Product free of charge includes freight cost.
Furthermore, YSmart provides an additional limited warranty for 14 years for
repair or replace the Defective Product free of charge but non-free of freight charge.
For warranty questions, please contact your retailer or installer. If your device has a
defect or malfunction during the warranty period, please also contact your retailer
or installer.
Warranty claims are excluded for:
• Alterations or repairs to the unit without prior authorization
• Improper use of device
• Improper and non-standard installation
• Improper operation
• operating the equipment with defective safety devices
• Impact of foreign objects and force majeure (lightning, surge, storm, fire)
• Inadequate or nonexistent ventilation of the device
• disregarding of safety regulations
• shipping damage
• The Product has been improperly stored or was damaged while in possession of
the Dealer or end user;
Stackable used:
WARNING! Only qualified electrical professionals can do the
trouble shooting of the Smart Microinverter system.
WARNING! Disconnect the AC grid first before
disconnecting the inverter from the PV module.

IP Series Grid Tie inverter
4
For more than one pcs inverter,you can connect like this.5pcs inverter in a
group,just need one launcher.connect as below
Single phase output stackable used method:
Three phase output connect method.
Large scale photovoltaic power generation engineering application
4. Adopting high-frequency isolation transformer type, high efficiency, high security.
5. Perfect electrical protection function.
6. Aluminum alloy housing, not rust, heat-resisting and cold-resistant as well as
anti-corrosion.
7. Getting electronic circuit design, appearance design and other core technology patents.
8. Package of high-quality thermal potting silicone, completely cut off from electronic
components in contact with air, almost stop the aging of electronic components, greatly
enhancing the life of the product.
9.MCU central control and information collection, with the information transmitter and
information collection, remote monitoring, so you can learn anytime, anywhere and
monitor the status of solar power wherever.
(Communication configuration section separately)
Important Safety Information
Read this First
This manual contains important instructions for use during installation and
maintenance of the YSmart Smart Microinverter. To reduce the risk of electrical
shock, and to ensure the safe installation and operation of the YSmart Smart
Microinverter, the following safety symbols appear throughout this document to
indicate dangerous conditions and important safety instructions.
Follow instruction closely.
Safety Instruction
Do not use Smart microinverter in a manner not specified by the manufacturer. Doing so
DANGER! This indicates a hazardous situation, which if not
avoided, will result in death or serious injury.
WARNING! This indicates a situation where failure to follow
instructions may be a safety hazard or cause equipment
malfunction. Use extreme caution and follow instructions
carefully.
NOTE: This indicates information particularly important for
optimal system operation.

IP Series Grid Tie inverter
5
may cause death or injury to persons, or damage to equipment.
Perform all electrical installations in accordance with all applicable local electrical codes.
Be aware that only qualified personnel should disassemble and repair the Smart
Microinverters and non-qualified personnel should not install and/or repair.
Do not attempt to repair the Smart Microinverter; it contains no user-serviceable parts. If
it fails, contact YSmart customer service to claim a return merchandise authorization and
start the replacement process. Tampering with or opening the Smart Microinverter will
void the warranty.
If the AC cable connector on the microinverter is damaged or broken, do not install the
unit.
Before installing or using the Smart Microinverter, read all instructions and cautionary
markings in the technical description and on the Smart Microinverter System and the PV
equipment.
Connect the Smart Microinverter to the utility grid only after you have completed all
installation procedures and after receiving prior approval from the local electrical utility
company.
Be aware that the body of the Smart Microinverter is the heat sink. Under normal
operating conditions, the temperature is 15°C above ambient, but under extreme
conditions the microinverter can reach a temperature of 75°C. To reduce risk of burns, use
caution when working with microinverters.
Do NOT disconnect the PV module from the Smart Microinverter without first removing AC
power.
The better disconnect DC terminal first. It may cause of components damaged if removing
AC power first when Smart Microinverter still operation. It is available to disconnect AC
power first when Smart Microinverter is not working but the better to disconnect the DC
terminal first.
Keep away from children, no touching, no playing so as not to electric shock when using.
Please installed in place of low humidity and well-ventilated so as to avoid inverter
overheating, as well as clear around the inflammable and explosive materials.
Troubleshooting a non-operating Smart microinverter
System halted and /or without power output
a. Check if switch of Smart Microinverter is turn on or not,
b. Check if the DC connections to Smart Microinverter are correct or not,
c. Check if any reverse DC connections for positive or negative or not,
d. Check if DC input voltage is within the range of the Smart Micro
inverter’s not,
e.Check if the utility grid voltage and frequency are fit in with the serviceable
range of Smart Microinverte or not,
f. Check if fuses of DC side are fusing or not,
g. Check if utility grid voltage properly connecting to Smart Microinverters or
not,
DC power supply is normal but no power output:
a. Check if utility grid voltage is connecting to Smart Microinverter or not,
b. Check if utility grid voltage is fit in with the serviceable range of Smart
Microinverte or not,
c. Please visual inspection for the LED operation status, red LED will turn off and
green LED will flash or run when inverter connecting with DC power source which
input voltage is fit in with the range as specified and power grid properly. If still no
power output when green LED flash or run, probably internal components are
damaged, in such case, please turn the defective inverter back for further analyze.
Please visual inspection for the LED operation status, red LED still turn on and
green LED without any flash or run when inverter connecting with DC power
source which input voltage is fit in with the range as specified and power grid
properly, probably internal components are damaged, in such case, please turn the
defective inverter back for further analyze.

IP Series Grid Tie inverter
6
Status Indications of LED
1. Red LED indicator lights up under any conditions include but not limited:
a. Low-voltage protection (DC input voltage lower than Min. input voltage of
inverters),
b. Over-voltage protection (DC input voltage higher than Max. input voltage of
inverters),
c. Over-temperature protection (inverters will shut down for power output when
temperature of body of inverters higher than 65-75 ℃, and inverter will be
automatically restart up when temperature down to 40-50℃.)
d. Power grid fault protection when 110VAC or 220VAC grid power outage and/or
tripped.
e. Islanding protection: inverter will be automatically shut down for power output
when disconnect with power grid.
2. Green LED indicator lights up under any conditions include but not limited:
a. Green LED flash: adjusting for power output, MPPT operating for tracking.
b. Green LED long light: indicates inverter locking-in Max. output power operation
status.
Parameter table of SY-IP series smart grid tie micro inverter (suit for 72cell
solar panel, Vmp:35-37;Voc:44-46V)
1 Power 200W 250W 300W
2 Solar panels ≥200W ≥250W ≥300W
3 DC MAX input 230W 280W 320W
4 DC input range 22-45VDC
5 MPPT Voltage 31-40V
6 DC MAX current 15A 25A 30A
7 AC MAX output 215W 270W 320W
8 AC output range 120VAC(90-140VAC) or 230VAC(190-260VAC)
9 Frequency range 50Hz/60Hz(Auto control)
10 Power Factor >98.5%
11 THD <5%
12 Phase Shift <2%
13 Efficiency 120VAC(90-140VAC)
14 Peak Efficiency >93% >92% >91%
15 Stable Efficiency >92% >91% >90%
16 Efficiency 230VAC(190-260VAC)
17 Peak Efficiency >95% >95% >95%
18 Stable Efficiency >93% >93% >93%
19 Protection Islanding; Short-circuit; converse connection; Low
Voltage; Over Voltage; Over temperature Protection
20 Work Temperature ‘-25℃-65℃
21 Work Humidity Waterproof design
22 Grade of Waterproof IP65
23 Show Red and green LED
24 Cooling thermal conductivity silica gel(Natural cooling)
25 Stand-by Power 1-2W
26 EMC EN61000-6-3:2007 EN61000-6-1:2007
27 Grid Disturbance EN 50178+EN 62109-1+VDE0126-1-12
28 Grid Detection DIN VDE 1026 UL1741
29 Certificate CE

IP Series Grid Tie inverter
7
Package
Net Weight 1.3KGS/PCS
Gross Weight 2.0KGS/PCS
Inner Box (L x W x H) 30*20.3*11.3CM
Carton(L x W x H) 42*31.5*35.5CM
Installation( for 1pcs inverter)
一, Diagrammatize DC input and AC output terminals,
二,Attach the Smart Microinverter to the racking or fix onto the wall,
三 , Properly connect the positive and negative of solar panel and Smart
Microinverter,
四, AC power cable connects with Smart Microinverter and residential power grid
which refers to low voltage civilian single-phase power grid.
五,Switch on power grid after check for input and output connections are correct
and then switch on the Smart Microinverter. Red/green LED lights up first, and red
LED lights off follow on and green LED lights on and flash fast, next LED flash
slowly which indicates that Smart Microinverter is in processing of MPPT
operation for tracking down the Maximum power point from solar module. Finally,
green LED last lights on and indicates that maximum power point lock-in. Smart
Micro inverter proper functioning and outputsteady.
Table of contents
Other YSmart Technology Inverter manuals