73.5
150
1,0 mm2
0,75 mm2
27.5
41.5
230 V AC
14 V DC
CAUTION ! The device is designed for single-phase installation and
must be installed in accordance with standards valid in a particular
country. Installation, connection and control should be carried out
by a qualied electrician sta, who act in accordance with the ser-
vice manual and the device functions.
1. Disconnect power supply by the phase fuse, the circuit-breaker or the
switch- disconnector combined to the proper circuit.
2. Check if there is no voltage on connection cables by means of a special
measure equipment.
3. Connect the output cables in accordance with the connection dia-
gram.
4. Mount the ZNN-08-14 device in a proper place.
5. Switch on the power supply from the mains.
•The power supply should be installed in a place that allows good
heat release.
•When connecting ttings or devices to ZNN-08-14 power supply
pay attention to a correct polarity of the output cables.
•Total power capacity can not exceed the nominal power of the
power supply.
ZNN-08-14 power supply for surface mounting is a professional impulse
power supply with 14 V DC voltage stabilizer. It is designed for surface
mounting. The nominal power output is 8 W. The power supply is rec-
ommended to supply the devices belonging to the LEDIX group. The
product has a short-circuit and overload protections, which increase the
safety of its use. Its high eciency and a very low power consumption
in the standby mode, makes it a very economical solution, designed for
continuous operation. The power supply meets the requirements of the
harmonized standards. The features of the power supply:
•14VDCnominaloutputvoltage,8Wnominalpower,
•low power consumption in the standby mode (0,25 W),
•eciency at the level of 79%,
•high stability of the output voltage with input voltage or load changes,
•protections: short-circuit, overload,
•wide ambient temperature range: -10 ÷ +50 oC,
•long-term operation reliability,
•output connecting cables 150 mm long.
*refers to the tting - in order to keep the protection degree it is
required to carry out an IP connection with a degree of not less
than IP56
TECHNICAL DATA
MOUNTING
DESCRIPTION DIMENSIONS
DIAGRAM
Nominal output voltage: 14 V DC
Nominal output current: 0,57 A
Nominal output power: 8 W
Output voltage tolerance: 5%
Output voltage ripples: 80 mVPP
Output voltage time increase: 10 ms
Output voltage time adjustment: 20 ms
Nominal input voltage: 230 V AC
Input voltage tolerance: -10 ÷ 15%
Nominal frequency: 50 Hz
Eciency: 79 ÷ 80%
Power consumption (standby): 0,25 W
Starting current: 20 A
Protections: short-circuit,
overload
Ambient temperature range: -10 ÷ +50 oC
Mounting: surface
Casing protection degree: IP56*
Protection class: II
Dimensions: 41,5 x 73,5 x 27,5 mm
Weight: 105 g
Reference standard: PN-EN 61204-3; PN-EN 55022;
PN-EN 61000
LEDIX series
lighting
10 ÷ 14 V DC