Zamel ledix ZSL-25-12 User manual

MESH LED POWER SUPPLY ZSL-25-12, ZSL-35-12, ZSL-60-12, ZSL-100-12, ZSL-150-12
MANUAL INSTRUCTION
ZAMEL Sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamel.com, e-mail: [email protected]
ZSL-25_35_60_100_150_inst_GB | 29.04.21
FEATURES
DESCRIPTION
● ForuseinhouseholdLEDinstallations.
● 12VDCoutputvoltageofhighstability.
● Widerangeofoutputpower.
● Overvoltageandshort-circuitprotec-
tions.
● No-loadoperationresistance.
● Freemountingindooronly.
● Outputvoltageadjustmentbymeans
ofapotentiometerwithinaminimum
rangeof10%nominalvoltage.
ZSL series switched-mode power sup-
plies are designed for a direct use in
home LED lighting installations. Their
modular construction allows for an easy
andcomfortablemountingindoortohor-
izontal and vertical surfaces. The 12 V
DC output voltage power supplies are
availableinawiderangeofoutputpower
(25÷150W).Thebuilt-inprotectionsguar-
anteeacontinuousandundisturbedoper-
ationofallconnectedLEDelements.The
powersuppliesareequippedwithoutput
voltage adjustment within the minimum
rangeof±10%bymeansofapotentiom-
eter.Metalcasingensuresproperpower
supplycoolingandprolongsitslife.
TECHNICAL DATA
ZSL-25-12 ZSL-35-12 ZSL-60-12 ZSL-100-12 ZSL-150-12
Input parameters
Inputvoltagerange: 110÷260VAC
Inputfrequencyrange: 50 / 60 Hz
Input current: 0,3 A 0,38 A 0,65 A 0,85 A 1,05 A
Powersupplycons-
umptionduringnoload: ~0,5 W ~0,6 W ~1,5 W ~0,9 W ~3,9 W
Efciency: 85% 75% 80% 83% 83%
Powerfactor: 0,5
Output parameters
Nominaloutputvoltage: 12VDC
Nominal output current: 2,5 A 3 A 5 A 8,5 A 12,5 A
Outputcurrentrange: 0÷2,5 A 0÷3 A 0÷5 A 0÷8,5 A 0÷12,5 A
Nominaloutputpower: 25 W 35 W 60 W 100 W 150 W
Ripples and noises
(max): 200mVpp
Uadjustmentrange: 10,5÷13,5V 8,5÷13V 11,3÷13,2V 11,5÷12,8V 10,8÷15V
Voltagetolerance: 1%
Outputvoltagetime
increase (max): ~15 ms
Outputbackuptime
(max): ~80 ms
Other parameters
Overloadprotection: Yes–returnable (app.180÷200%Pn)
Outputshort-circuit
protection: Yes–returnable
Thermalprotection: No
Resistance to idle state: Yes
Operatingtemperature: -20÷60°C
Protection class: I
Overvoltagecategory: II
Casingprotection
degree: IP20
Mounting: free
Operatingposition: Free(horizontalorverticalplane)
Dimensions (mm): 87x59x32,5 87x59x32,5 110x78x36,5 162x99x42 200x98x42,5
Weight: 100g 115g 195g 340g 385g
Referencestandard: PN-EN 55015, PN-EN 61547, PN-EN 6100-3-2,
PN-EN 6100-3-3, PN-EN 61347-1
Connect this product to a
single-phase power system ac-
cording to applicable electrical
and safety standards and regu-
lations. See this Manual for the
wiring instructions. Installation,
wiring and adjustment/setting shall only be
done by qualied electricians who have read
and understood this User Manual and the
functions ofthe product.Donotopenor oth-
erwisedisassembletheproducthousing;oth-
erwise the product warranty will be void and
an electrocution hazard may occur. Prior to
installing and wiring this product, make sure
thatthewiringtobeconnectedisnotlive.The
conditionsandmethodsoftransport,storage
and operation of this product may affect its
performance.Donotinstalltheproductifany
ofitscomponentsaremissing,theproductis
damagedordeformedinanyway.Ifanymal-
functionsarefound,consultthemanufacturer.
CAUTION
Do not dispose of this device with other
waste! In order to avoid harmful effects on
the environment and human health, the
used device should be stored in designated
areas. For this purpose, you can dispose
of household waste free of charge and in
any quantity to a collection point set up,
as well as to the shop when you buy new
equipment.

WARRANTY CARD
Thereis24monthsguaranteeontheproduct.
Salesman stamp and signature, date of sale.
1.ZAMELSp.zo.o.assures24monthsguaranteefortheproduct.
2.Themanufacturer’sguaranteedoesnotcoveranyofthefollowingactions:
a)mechanicaldamageduringtransport,loading/unloadingorunderothercircumstances,
b)damagecausedbyincorrectproductmountingormisuse,
c)damagecausedbyunauthorisedmodicationsmadebythePURCHASERoranythirdpartiestothe
productoranyotherdevicesneededfortheproductfunctioning,
d)damagecausedbyActofGodoranyotherincidentsindependentofthemanufacturer-ZAMELSpzo.o.
e)supplysources(batteries)includedinthedeviceduringselling(iftheyareincluded).
3.ThePURCHASERshalllayanyclaimsinwritingtothedealerorZAMELSp.zo.o.
4.ZAMELSp.zo.o.isliableforprocessinganyclaimaccordingtocurrentPolishlegislation.
5.ZAMELSp.zo.o.shallprocesstheclaimatitsowndiscretion:productrepair,replacementormoneyreturn.
6.ThePURCHASER’sstatutoryrightsinanyapplicablelegislationwhetheragainsttheretailerarisingfromthepurchasecontractor
otherwisearenotaffectedbythiswarranty.
MOUNTING PRODUCT FAMILY
1.Disconnectpowersupplybythephase
fuse,thecircuit-breakerortheswitch-
-disconnectorcombinedtotheproper
circuit.
2.Check if there is no voltage on con-
nectioncablesbymeansofaspecial
measureequipment.
3.Connectthecableswiththeterminals
ofZSL-XX-12power supply inaccor-
dancewiththeinstallingdiagram.
4.
Afterconnectingthecablesprotectthe
terminals with a cover (refers to ZSL-
60-12, ZSL-100-12, ZSL-150-12).
5.Sw
itch on the power supply from the
mains.
6. If required adjust the appropriate
Uoutvaluebymeansofapotentiome-
ter.
DIAGRAM
LEGEND OF SYMBOLS
Outputvoltageadjustment.
Devicemadeinprotection
class I.
The ZSL power supplies belong to the
productfamily:
ZSL - XX - 12
Outputpower
Devicesymbol
Outputvoltageadjustment.
25 – 25 W / 2,1 A
35 – 35 W / 3 A
60 – 60 W / 5 A
100 – 100 W / 8,5 A
150 – 150 W / 12,5 A
ZSL-25-12
ZSL-35-12
ZSL-60-12
IN OUT IN OUT
Uout
adjustment
PE
N
L
Uout
adjustment
Uout
signalling
Uout
signalling
ZSL-100-12
ZSL-150-12
This manual suits for next models
4
Other Zamel Power Supply manuals