MESH LED POWER SUPPLY ZSL-25-12, ZSL-35-12, ZSL-60-12, ZSL-100-12, ZSL-150-12
MANUAL INSTRUCTION
ZAMEL Sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamel.com, e-mail: [email protected]
ZSL-25_35_60_100_150_inst_GB | 29.04.21
FEATURES
DESCRIPTION
● ForuseinhouseholdLEDinstallations.
● 12VDCoutputvoltageofhighstability.
● Widerangeofoutputpower.
● Overvoltageandshort-circuitprotec-
tions.
● No-loadoperationresistance.
● Freemountingindooronly.
● Outputvoltageadjustmentbymeans
ofapotentiometerwithinaminimum
rangeof10%nominalvoltage.
ZSL series switched-mode power sup-
plies are designed for a direct use in
home LED lighting installations. Their
modular construction allows for an easy
andcomfortablemountingindoortohor-
izontal and vertical surfaces. The 12 V
DC output voltage power supplies are
availableinawiderangeofoutputpower
(25÷150W).Thebuilt-inprotectionsguar-
anteeacontinuousandundisturbedoper-
ationofallconnectedLEDelements.The
powersuppliesareequippedwithoutput
voltage adjustment within the minimum
rangeof±10%bymeansofapotentiom-
eter.Metalcasingensuresproperpower
supplycoolingandprolongsitslife.
TECHNICAL DATA
ZSL-25-12 ZSL-35-12 ZSL-60-12 ZSL-100-12 ZSL-150-12
Input parameters
Inputvoltagerange: 110÷260VAC
Inputfrequencyrange: 50 / 60 Hz
Input current: 0,3 A 0,38 A 0,65 A 0,85 A 1,05 A
Powersupplycons-
umptionduringnoload: ~0,5 W ~0,6 W ~1,5 W ~0,9 W ~3,9 W
Efciency: 85% 75% 80% 83% 83%
Powerfactor: 0,5
Output parameters
Nominaloutputvoltage: 12VDC
Nominal output current: 2,5 A 3 A 5 A 8,5 A 12,5 A
Outputcurrentrange: 0÷2,5 A 0÷3 A 0÷5 A 0÷8,5 A 0÷12,5 A
Nominaloutputpower: 25 W 35 W 60 W 100 W 150 W
Ripples and noises
(max): 200mVpp
Uadjustmentrange: 10,5÷13,5V 8,5÷13V 11,3÷13,2V 11,5÷12,8V 10,8÷15V
Voltagetolerance: 1%
Outputvoltagetime
increase (max): ~15 ms
Outputbackuptime
(max): ~80 ms
Other parameters
Overloadprotection: Yes–returnable (app.180÷200%Pn)
Outputshort-circuit
protection: Yes–returnable
Thermalprotection: No
Resistance to idle state: Yes
Operatingtemperature: -20÷60°C
Protection class: I
Overvoltagecategory: II
Casingprotection
degree: IP20
Mounting: free
Operatingposition: Free(horizontalorverticalplane)
Dimensions (mm): 87x59x32,5 87x59x32,5 110x78x36,5 162x99x42 200x98x42,5
Weight: 100g 115g 195g 340g 385g
Referencestandard: PN-EN 55015, PN-EN 61547, PN-EN 6100-3-2,
PN-EN 6100-3-3, PN-EN 61347-1
Connect this product to a
single-phase power system ac-
cording to applicable electrical
and safety standards and regu-
lations. See this Manual for the
wiring instructions. Installation,
wiring and adjustment/setting shall only be
done by qualied electricians who have read
and understood this User Manual and the
functions ofthe product.Donotopenor oth-
erwisedisassembletheproducthousing;oth-
erwise the product warranty will be void and
an electrocution hazard may occur. Prior to
installing and wiring this product, make sure
thatthewiringtobeconnectedisnotlive.The
conditionsandmethodsoftransport,storage
and operation of this product may affect its
performance.Donotinstalltheproductifany
ofitscomponentsaremissing,theproductis
damagedordeformedinanyway.Ifanymal-
functionsarefound,consultthemanufacturer.
CAUTION
Do not dispose of this device with other
waste! In order to avoid harmful effects on
the environment and human health, the
used device should be stored in designated
areas. For this purpose, you can dispose
of household waste free of charge and in
any quantity to a collection point set up,
as well as to the shop when you buy new
equipment.
WARRANTY CARD
Thereis24monthsguaranteeontheproduct.
Salesman stamp and signature, date of sale.
1.ZAMELSp.zo.o.assures24monthsguaranteefortheproduct.
2.Themanufacturer’sguaranteedoesnotcoveranyofthefollowingactions:
 a)mechanicaldamageduringtransport,loading/unloadingorunderothercircumstances,
 b)damagecausedbyincorrectproductmountingormisuse,
 c)damagecausedbyunauthorisedmodicationsmadebythePURCHASERoranythirdpartiestothe
 productoranyotherdevicesneededfortheproductfunctioning,
 d)damagecausedbyActofGodoranyotherincidentsindependentofthemanufacturer-ZAMELSpzo.o.
 e)supplysources(batteries)includedinthedeviceduringselling(iftheyareincluded).
3.ThePURCHASERshalllayanyclaimsinwritingtothedealerorZAMELSp.zo.o.
4.ZAMELSp.zo.o.isliableforprocessinganyclaimaccordingtocurrentPolishlegislation.
5.ZAMELSp.zo.o.shallprocesstheclaimatitsowndiscretion:productrepair,replacementormoneyreturn.
6.ThePURCHASER’sstatutoryrightsinanyapplicablelegislationwhetheragainsttheretailerarisingfromthepurchasecontractor
otherwisearenotaffectedbythiswarranty.
MOUNTING PRODUCT FAMILY
1.Disconnectpowersupplybythephase
fuse,thecircuit-breakerortheswitch-
-disconnectorcombinedtotheproper
circuit.
2.Check if there is no voltage on con-
nectioncablesbymeansofaspecial
measureequipment.
3.Connectthecableswiththeterminals
ofZSL-XX-12power supply inaccor-
dancewiththeinstallingdiagram.
4.
Afterconnectingthecablesprotectthe
terminals with a cover (refers to ZSL-
60-12, ZSL-100-12, ZSL-150-12).
5.Sw
itch on the power supply from the
mains.
 6. If required adjust the appropriate
Uoutvaluebymeansofapotentiome-
ter.
DIAGRAM
LEGEND OF SYMBOLS
Outputvoltageadjustment.
Devicemadeinprotection
class I.
The ZSL power supplies belong to the
productfamily:
ZSL - XX - 12
Outputpower
Devicesymbol
Outputvoltageadjustment.
25 – 25 W / 2,1 A
35 – 35 W / 3 A
60 – 60 W / 5 A
100 – 100 W / 8,5 A
150 – 150 W / 12,5 A
ZSL-25-12
ZSL-35-12
ZSL-60-12
IN OUT IN OUT
Uout
adjustment
PE
N
L
Uout
adjustment
Uout
signalling
Uout
signalling
ZSL-100-12
ZSL-150-12

This manual suits for next models

4

Other Zamel Power Supply manuals

Zamel Ledix ZNN-08-14 User manual

Zamel

Zamel Ledix ZNN-08-14 User manual

Zamel Cet LediX ZNN-15-14 User manual

Zamel

Zamel Cet LediX ZNN-15-14 User manual

Popular Power Supply manuals by other brands

ZALMAN LEII Series user manual

ZALMAN

ZALMAN LEII Series user manual

Eaton MTL 9491-PS instruction manual

Eaton

Eaton MTL 9491-PS instruction manual

WAC Lighting PS-24DC-U60R-CS-SM Installation instruction

WAC Lighting

WAC Lighting PS-24DC-U60R-CS-SM Installation instruction

Thermal Dynamics CE PAK Master 75XL operating manual

Thermal Dynamics

Thermal Dynamics CE PAK Master 75XL operating manual

Vertiv NetSure V200D50 Installation and user manual

Vertiv

Vertiv NetSure V200D50 Installation and user manual

Simu 9014738 instructions

Simu

Simu 9014738 instructions

Fractal design Tesla user manual

Fractal design

Fractal design Tesla user manual

Altronix AL1012X220 Series installation guide

Altronix

Altronix AL1012X220 Series installation guide

Oakley RPSU Builder's guide

Oakley

Oakley RPSU Builder's guide

Emerson NetSure 501 A50 instruction manual

Emerson

Emerson NetSure 501 A50 instruction manual

Potter Elmdene 2402ST Series manual

Potter

Potter Elmdene 2402ST Series manual

Grizzly H8178 owner's manual

Grizzly

Grizzly H8178 owner's manual

Horizont ranger AN480 instruction manual

Horizont

Horizont ranger AN480 instruction manual

Xantrex XPR 10-600 operating manual

Xantrex

Xantrex XPR 10-600 operating manual

Emerson PACSystems RX3i quick start guide

Emerson

Emerson PACSystems RX3i quick start guide

Siemens SITOP UPS1600 Equipment manual

Siemens

Siemens SITOP UPS1600 Equipment manual

Lumel HA-PSA3515 user manual

Lumel

Lumel HA-PSA3515 user manual

Ametek XPH 42-10 Operation manual

Ametek

Ametek XPH 42-10 Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.