Zator DLK22S Operating instructions

DLK22S
electromagnetic valve
USER AND
MAINTENANCE
MANUAL
gluing
soluons

USER AND MAINTENANCE MANUAL
DLK22S_v03
MARCH 2021
ZATOR SRL
Via Galvani, 11
20095 Cusano Milanino (MI)
Italy
Tel. +39 02 66403235
Fax +39 02 66403215
info@zator.it
www.zator.it

DECLARES
Under its responsibility that the electromagnec valve:
Legal RepresentaveCusano Milanino
Is in compliance with UE direcves, with relaon to the following ones and/or parts of them applicable
to this product:
• Direcve 2006/42/CE of European Parliament and Council of the 17th of May 2006 regarding to
machines and that modify direcve 95/16/CE (recasng)
• Direcve 2014/35/UE of European Parliament and Council of the 26th of february 2014 regarding
the harmonizaon of the UE Countries laws about the the making available on the market of
electrical equipment intended to be used within certain voltage limits (recasng)
• Direcve 2014/30/UE of European Parliament and Council of the 26th February 2014 regarding
the harmonizaon of the UE Countries laws about the electromagnec compability (recasng)
Model DLK22S Year of manufacture
UE Declaraon of Conformity
Manufacturer:
ZATOR Srl
Via Galvani 11
20095 Cusano Milanino (MI)
Italy
Tel.+39 02 66403235
Fax +39 02 66403215
Email: info@zator.it

1GENERAL INFORMATION 8
1.1 Introducon 8
1.2 Warranty 9
1.3 Warranty restricons 10
1.4 Maintenance service request 11
1.5 Spare parts request 11
2SAFETY RULES AND REGULATIONS 12
2.1 Safety and environment general informaons 13
2.2 P.P.E. Personal protecve equipment 13
2.3 Risks, protecons, warnings and cauons 14
2.3.1 General safety 14
2.3.2 Unavoidable dangers and risks unavoidable 15
2.3.3 Safety devices adopted 16
2.3.4 More general safety precauons 16
2.4 Environmental condion 17
2.5 Installaon - General instrucons 18
2.6 Use of adhesives, glues or other uids 19
3TECHNICAL DESCRIPTION 20
3.1 Valve funcons 20
3.2 Technical data 20
3.3 Funconing descripon 21
4INSTALLATION 22
4.1 Fixing of the valve 22
4.2 Contact-less gluing applicaon 22
4.3 Fluid supply connecon 23
4.4 Electrical connecon 23
4.5 Valve acvaon 24
Index

5VALVE ADJUSTMENTS 25
5.1 Fluid quanty adjustment 25
5.2 Needle travel adjustment 25
5.3 Nebulizaon adjustment 26
6MAINTENANCE 27
6.1 General norms 27
6.2 Maintenance program 27
6.3 Cleaning and/or replacement of the nozzle 28
6.4 Valve disassembly 30
6.5 Needle disassembly 33
6.6 Needle assembly 33
6.7 Valve assembly 34
7TROUBLE SHOOTING 36
8MODELS 37
9PART LIST 38
10 DIMENSIONS 40


USER AND
MAINTENANCE MANUAL
electromagnetic valve DLK22S

USER AND MAINTENANCE MANUAL
ELECTROMAGNETIC VALVE DLK22S
8
This manual is an essenal part of the electromagnec valve and is desned to trained and well-informed
personnel, which is aware of the machine performance at the risk condions to which it may be exposed.
This document supposes that in the plants where the valve is desned, are complied the present norms
of safety and hygiene of the work.
Zator Srl won’t be liable for acons or improper connecons made by unqualied and unformed
personnel.
Instrucons, drawings and documentaon contained in this manual are of reserved technical disposion,
only for Zator Srl property and may be not reproduced in any way, neither in full or parally reproducon;
not translated into another language, or transmied in any electronic or mechanical means or form,
without wrien permission of Zator Srl.
The data and values expressed in the manual are approximate and variable depending on uids,
applicaons and methods of use.
Zator Srl doesn’t assume any responsibility regarding the accuracy of the contents of this manual.
The drawings and technical data in this document is updated to the date of their publicaon and Zator
Srl reserves the right to change, without noce, the contents of this manual.
It is therefore forbidden for Technician and Operators of the maintenance to use this manual for dierent
purposes from those relaves to the care and maintenance of equipment in queson.
This manual includes the installaon, use and maintenance norms of the electromagnec valve in safety.
Test in producon workshop
The manufacturer guarantees the valve, that this document refers, has been inspected and tested by his
producon workshop.
“At term of law we reserve the property of the data and technical informaon with the prohibion of play,
communicate to third pares or use them anyway for any other execuve purpose and what is shown in
this document is the property of the Manufacturer”
1GENERAL INFORMATION
1.1 Introduction

SECTION 1 - GENERAL INFORMATION
9
Zator Via Galvani, 11- 20095- Cusano Milanino (MI)- Italy www.zator.it - info@zator.it
This warranty is valid for 12 months from the actual delivery.
During the warranty period Zator Srl is undertakes to remove in the necessary me the obvious faults and
aws of material and/or producon, on condion that machine or equipment has been used properly,
according to the best rules of behaviour and maintenance provided in this manual.
The awed parts under warranty are xed or replaced free from Zator Srl in the me compably necessary,
understood that the Zator Srl is exempted from each responsibility for any tle, while the buyer give up to
ask damages or costs, including those resulng from the temporary not use of the purchased machinery
for all the me is necessary to put it back in eciency; The transport and/or the forwarding costs, the
outward and the return trip costs relave to the operaon by the Zator’s technicians in the Buyer address
are always on charge of the buyer.
The labor costs relave to the operaon of the Zator’s technicians in the Buyer address for the removal of
awed parts under warranty, are on charge of Zator Srl, except these cases when the nature of the aw
can be easily removed on place by the Buyer.
This commitment of Zator Srl excludes each other warranty eects provided by the law.
The warranty for the replaced or repaired spare parts of the electromagnec valve nishes the same
day of the warranty expiraon date of the electromagnec valve, the replaced part warranty however
doesn’t has lifeme less than three months aer its installaon.
Replaced parts during the warranty period by the seller are free acquired in the same place with new
parts.
Are excluded from the warranty all the tools and consumable materials, possibly supplied by Zator Srl
with the machine.
It are excluded and renounced by the buyer every pretensions of items/people damages reimbursement
on charge to Zator Srl, for any tles, even if the damages were depending from manufacture or material
aws. It’s of equal excluded and given up any reimbursement for people and/or items damages depending
on the pracse of the electromagnec valve. Parts replaced free remain of Zator Srl property.
Elapsed the warranty period every operaon will be on charge to the buyer.
Applicaon elds
• Packaging machines
• Paper converng industry
• Prinng machines
• Tobacco industry
• Assembly industry
• Food industry
1.2 Warranty

USER AND MAINTENANCE MANUAL
ELECTROMAGNETIC VALVE DLK22S
10
Condemnaon of conformity aw - Goods recepon
The original conguraon of the electromagnec valve never must be changed.
On goods recepon, check that:
• The packaging is intact
• The exact correspondence of the commissioned material
In case of damages or wrong delivery contact immediately Zator Srl.
The buyer, on penalty of warranty decadence, must report in wring the aw conformity or fault of the
electromagnec valve to the seller, specifying in detail the nature, within eight days from their discovery.
In no case the condemnaon of conformity aw or fault may be validly made aer the expiraon date of
the warranty terms.
Also the buyer decays from the warranty if doesn’t allow each reasonable control that the seller requires.
It’s excluded from this warranty the most damage caused to the machine by the failure mely
condemnaon to the seller of a conformity aw or fault of the the electromagnec valve.
This warranty is only valid for products of new construcon.
This warranty is limited to the reparaon or replacement, by the seller, of each parts of the machine or
supplied material that results awed, aer checking the existence of the aw.
In no case the seller will be liable for every consequenal or indirect aws or otherwise derived from
producon cycle interrupon or machine stoppage.
The seller is not liable for aws of the electromagnec valve derived from the use of devices, equipments,
etc. that are enquired and provided by the customer and installed on the machine to change its use
compared to the original design.
The seller is not liable for every conformity aws of the electromagnec valve or faults owed for the
normal wear of those parts that, by their nature, are subject to rapid and connuous wear.
The seller also is not liable for damages resulng from improper use of the equipment and from the non-
observance of the norms expected for the execuon of the ordinary periodic maintenance.
The seller is not liable for conformity aws of the electromagnec valve or faults that depends on changes,
reparaons, alteraons or tampering aributed to the buyer and however non-authorized personnel of
the buyer.
The costs relave to the wear materials necessary for test and restart the electromagnec valve are on
charge of the buyer.
1.3 Warranty restrictions

SECTION 1 - GENERAL INFORMATION
11
Zator Via Galvani, 11- 20095- Cusano Milanino (MI)- Italy www.zator.it - info@zator.it
Contact:
Technical oce of Zator S.R.L.
Via Galvani 11 - 20095 Cusano Milanino (MI) - Italy
e-mail: info@zator.it www.zator.it
Tel.: +39-0266403235 Fax.: +39-0266403215
Always forward the request in wring (fax or email) and give all the informaon to idenfy the machine
object of the request:
• Model
• Serial number
Please refers to the fronspiece of this manual or directly to the nameplate on-board to the machine or
to the serial number of the electromagnec valve.
The customer is responsible to purchase original spare parts that guarantee him to keep ecient and
safe the electromagnec valve.
The disassembly and assembly operaons must be performed according to the manufacturer’s
instrucons.
Contact the Technical Oce of Zator Srl which will give to you the specicaons to do the request of the
parts and will provide the informaon about their replacement.
To order the spare parts is necessary to report completely all idencaon data of the electromagnec
valve and those of spare part to be replaced.
The illustraons in this document are for example.
1.4 Maintenance service request
1.5 Spare parts request

USER AND MAINTENANCE MANUAL
12 ELECTROMAGNETIC VALVE DLK22S
The Electromagnec valve DLK22S is designed and manufactured in compliance with the current safety
standard. Only trained personnel is authorized to install and use the electromagnec valve. For the
Electromagnec valve DLK22S are provided only and exclusively the applicaon elds describe in this
manual. All data and parameters indicated in this manual must be respected. Any other use is considered
improper.
All operaons performed with the Electromagnec valve DLK22S must be carry out in compliance with
the following current safety rules and regulaons wrien in part:
1. Rules of re prevenon
2. Direcve 2006/42/CE of European Parliament and Council of the 17th of May 2006 regarding to
machines and that modify direcve 95/16/CE (recasng)
3. Direcve 2014/35/UE of European Parliament and Council of the 26th of february 2014 regarding the
harmonizaon of the UE Countries laws about the the making available on the market of electrical
equipment intended to be used within certain voltage limits (recasng)
4. Direcve 2014/30/UE of European Parliament and Council of the 26th February 2014 regarding the
harmonizaon of the UE Countries laws about the electromagnec compability (recasng)
5. Rule 2016/425/UE of the 9th of March 2016, about the personal protecon equipment and that
abrogates the direcve 89/686/CEE of the Council
2SAFETY RULES AND REGULATIONS

SECTION 2 - SAFETY RULES AND REGULATIONS
13
Zator Via Galvani, 11- 20095- Cusano Milanino (MI)- Italy www.zator.it - info@zator.it
Before the start-up of the electromagnec valve the personnel must be adequately informed and trained
on its use, direcon and start-up process, as well as the safety norms to be performed and also observe
how it is prescribed in this document and in other documents possibly aached to the electromagnec
valve.
The employer must provide to instruct the personnel on the risks of injury, on safety devices and accident
prevenon general rules provided by the community direcves and the legislaon of the country where
the electromagnec valve is installed.
For personnel who will work on the electromagnec valve, for any funcons (installaon, assembly,
demolion, maintenance and operaon) they will be provided with appropriate P.P.E. - Personal protecve
equipment of type approved and cercate by C.E.:
• an-solvent gloves
• cut resistant gloves
• masks
• coverall (no oang coverall)
CAUTION: Always disconnect the power supply before proceed to carry out any maintenance
or adjustment operaons.
Discharge the uid pressure before to proceed to carry out any maintenance or adjustment
operaons.
CAUTION: The clothes of who will operate the electromagnec valve for any funcons must be
in compliance with the essenal safety requirements dened by the regulaon 2016/425/UE of
9th of May 2016 and by the actual laws in the country of use.
2.1 Safety and environment general informations
2.2 P.P.E. Personal protective equipment

USER AND MAINTENANCE MANUAL
14 ELECTROMAGNETIC VALVE DLK22S
In accordance with the Machine Direcve it means for:
DANGER ZONE = area within or near the electromagnec valve where the presence of an exposed
person make a risk to the safety and health of himself.
EXPOSED PERSON = any person that is placed enrely or parally inside a danger zone.
OPERATOR = person who is appointed to install, operate, adjust, perform ordinary maintenance and
clean the machine.
All risk areas of the electromagnec valve have been checked and consequently have been taken the
necessary precauons to avoid risks to people and damage to the components of the electromagnec
valve.
Safety glossary
Intended purposes
By this term it refers to the use of the machine as described by the manufacturer.
For “intended purposes” also refers to the use of the unit through its design, its construcon and funcon.
Secondary risks
Secondary risk are unavoidable despite all the prevenve measures that are taken.
Competent personnel
A person is competent when it acquired sucient knowledge in a specic eld both through the
professional instrucon and with the experience. A competent person must get to know with the specic
norms for the safety on work and for the accident prevenon and generally with the technical knowledge
rules.
Trained personnel
A person is trained when informed by a competent person about the acvies it must perform and the
risks relave to improper behaviour and, if necessary, it has received the required training. Also a trained
person must be informed about the safety devices and protecve measures.
2.3.1 General safety
2.3 Risks, protections, warnings and cautions

SECTION 2 - SAFETY RULES AND REGULATIONS
15
Zator Via Galvani, 11- 20095- Cusano Milanino (MI)- Italy www.zator.it - info@zator.it
On the electromagnec valve also equipped with protecon systems remain the following R. R. RESIDUAL
RISKS:
A - Danger due to electricity in general
B - Danger due to inhalaon of dangerous vapours to health and re danger
C - Danger due to problems/malfuncons of the electromagnec valve
This can lead an excessive increase of dispensing of glue as well as a re danger or dangers due to
inhalaon of dangerous vapours to health.
D - Risk due to the projecon of uids under pressure
In case of improper maintenance of the hydraulic system parts.
E - Risk of re
Prohibion of smoking and/or high temperature objects near the electromagnec valve.
Skilled personnel
A skilled person is a competent one or suciently trained.
The operator must be informed of the posion and operaon of all commands and features of the
electromagnec valve.
The maintenance and start-up operaons must be performed by qualied technicians aer properly
seng up the electromagnec valve.
The unauthorized tampering or replacement of one or more product parts, the adopon of accessories
that modify the original use of the electromagnec valve and the purpose of dierent consumer product
from those recommended in this manual, can become a cause of injury risks.
The protecve devices must not be removed or tampered for the risk to reduce the accident prevenon
features of our products.
To highlight parcular situaons for the safety of the instrument, are used the following graphic
symbols:
2.3.2 Unavoidable dangers and risks unavoidable
CAUTION and/or DANGER – Accident prevenon rules for the operator
R. R. – RESIDUAL RISKS
WARNING - There is the possibility to damage the machine and/or its components
PRECAUTION - Further informaon about the operaon in progress
NOTE - Provides useful informaon

USER AND MAINTENANCE MANUAL
16 ELECTROMAGNETIC VALVE DLK22S
In order to safeguard the health and security of the exposed people, the electromagnec valve is
equipped with:
• Fixed guards: removable only by tools
• Mobile guards: depending on the model of electromagnec valve
The electromagnec valve can be equipped with area delimiters that prevent operator access to
dangerous areas (see R.R.).
CE norms signage: examples of danger symbols
2.3.3 Safety devices adopted
2.3.4 More general safety precauons
CAUTION: The maintenance operaons must be peremptorily carry out by qualied and
authorized personnel, only and exclusively with electromagnec valve turned o: power switch
in “OFF” posion.
Make sure the passages around the electromagnec valve are not hindered by misplaced cables
and dangerous for personnel.
The user must always put available to the operators, in the areas that require it, safety googles,
gloves, and any other necessary protecons; it must also make sure that these safeguards are
being used.
The areas that require the use of protecve clothing must be marked with warning signs and
pictograms indicang the residual risk.
CAUTION: is ABSOLUTELY FORBIDDEN to tamper or remove the plates and the protecons on
the electromagnec valve.
The manufacturer declines all responsibility for the safety of the electromagnec valve in case
of omied observance of the prohibion.
C
Corrosive O
Combusve
agent
Flammable
P
Toxic
Danger High voltage

SECTION 2 - SAFETY RULES AND REGULATIONS
17
Zator Via Galvani, 11- 20095- Cusano Milanino (MI)- Italy www.zator.it - info@zator.it
Operang environmental condions
The electromagnec valve is designed to operate in a closed local, protected from the atmospheric
agents, with all the safety requirements resulng from the laws in force.
Waste disposal
The buyer is responsible to follow the correct process and the norms in force in the country for the
disposal of waste and residual material.
Disposal
The pick up of special and/or toxic-noxious waste must be commied with contract to specically
authorized companies and who do the transport materially must be in ownership of the required
authorizaons and must be turn out to be registered in the haulers register.
It’s absolutely forbidden to throw waste in the environment.
For the disposal of the packaging, the user must follow the laws in force in the country of plant installaon.
Fire material
There is no re dangers by the operaon of the electromagnec valve.
2.4 Environmental condition
Lighng
The customer is responsible for ensuring an appropriate lighng of the local where the machine is
installed, according to the laws in force in your country and the EU direcves.
Vibraons
The electromagnec valve doesn’t make vibraons.
CAUTION: The customer must provide an appropriate re-ghng system, evaluang its internal
situaon and respecng the laws in force.
In case of re, disconnect immediately the power switch to interrupt the power supply.
CAUTION: explosive atmosphere
The electromagnec valve is not designed to operate in explosive atmosphere. It is forbidden to
use the machine in an explosive atmosphere, even if only parally explosive.

USER AND MAINTENANCE MANUAL
18 ELECTROMAGNETIC VALVE DLK22S
Zator’s products are manufactured in compliance with the laws in force during its construcon.
The personnel will be trained and qualied to take advantage of the installed electromagnec valve
requirements.
The personnel must operate in a comfortable space that could be guarantee safety and hygiene for the
operator.
In case of a dierent desnaon or necessity of use of the electromagnec valve, it’s appropriate to refer
to the technical oces of the Zator Srl.
Goods in packaging
Outside the package are indicated all the informaon about the content idencaon and the safety
movement:
• address of the sender and the addressee
• dimensions: length – width – height
• gross – net – tare weight
• annotaons and pictograms (ex. brile, handle with care, high)
CAUTION: The customer must check the condion of the goods upon its arrival.
Predisposions: choose the installaon space
Without prejudice to specic disposions, the customer will be provide to:
• Appropriate logisc arrangement for the placement and conducon of the electromagnec valve
• Power supply, including the protecve conductor usually called “GROUNDED”
• Electrical equipment arrangement and possible pneumac system, if required
• Wear materials
For the electrical connecon it is necessary to have a preferenal line of power supply with the features
listed in “technical features”.
2.5 Installation - General instructions

SECTION 2 - SAFETY RULES AND REGULATIONS
19
Zator Via Galvani, 11- 20095- Cusano Milanino (MI)- Italy www.zator.it - info@zator.it
The use of the valve with adhesives, glues or general uids must be respect the following basic rules.
Before use a specic type of uid check that:
• The uid viscosity is compable with the features of the valve
• The characteriscs of the uid meet the desired requirements
• The datasheet of the uid provided by the manufacturer includes all the informaons about the uid
such as: viscosity, applicaons, gluing me (for glues or adhesives) and storage
• The storage me of the uid has not been exceeded
• The uid has not been exposed to temperatures near or below than zero therefore it has deteriorated
• The packaging of the uid are sealed
For the use of special adhesives, glues or uids we recommend to contact the Zator company to verify
the compability of the applicaon.
Before use a dierent type of uid clean accurately the valve to avoid possible contaminaon of the new
uid.
When used water-based adhesives of glues they are easily removable with water in their liquid state.
However, when they harden is more dicult to remove it. For this reason, before long stop it is
recommended to wash accurately the valve. Please refer to the maintenance program shown in this
manual.
2.6 Use of adhesives, glues or other fluids

USER AND MAINTENANCE MANUAL
20 ELECTROMAGNETIC VALVE DLK22S
The electromagnec valve DLK22S has been designed and
realized for its use on various kind of producon machines
operang at high speed: its design and versality make it
ideal for any applicaons that require the use of dispensing
valves.
It’s an high-speed nebulizer dispenser (spray) of low viscosity
glues, adhesives and uids (max 200 mPas).
It is controlled by a Zator’s microprocessor control or by an
instrument of external control aer tesng and approval of
Zator company.
The DLK22S valve is manufactured enrely of stainless steel,
and it has the parcularity to have nozzle and cap with an-
sck coang and a self-cleaning needle which ensure the long
operaon me of the valve. The micrometric adjustment
allows a ne control of the glue quanty dispensed.
3TECHNICAL DESCRIPTION
3.1 Valve functions
3.2 Technical data
fluid types
adhesives and glues
paints
inks
mascs
low viscosity uids
Available nozzle diameters da 0,3 a 1,5 mm
Valve body acciaio inox
Maximum uid viscosity ca. 2000 mPas
Maximum working pressure 8 bar
Maximum working frequency 350 dots/sec.
Coil 6 or 24 Volt
Weight 340 g
Spray
Other manuals for DLK22S
1
Table of contents
Other Zator Control Unit manuals

Zator
Zator B2755 00 Series Operating instructions

Zator
Zator MZB200 Operating instructions

Zator
Zator DLK22LT-LC Operating instructions

Zator
Zator DLK22S Operating instructions

Zator
Zator MZK4 KVNR Series Operating instructions

Zator
Zator MZL100 Operating instructions

Zator
Zator MZD100 Operating instructions

Zator
Zator DLK22LV Operating instructions

Zator
Zator B2748 00 Series Operating instructions

Zator
Zator MZF Operating instructions