GetFace IP
Basic Unit with or without camera
ZVP-CAM / ZVP-WOCAM Technical documentation
© Zennio Avance y Tecnología S.L. Ed. 1 Further information www.zennio.com Page. 1/ 2
FEATURES
•Connectors:
oRJ-45 Ethernet 10/100Base-TX Auto-MDIX.
It allows PoE supply 802.3af – Class 0 – 12.95W.
oIN1: Passive or active input (-30..30VDC).
0=open or VIN1>1.5VDC / 1=closed or VIN1<1.5VDC.
oOUT1: Active output (8..12VDC, IMAX=400mA).
oRELAY1: Relay contacts NO/NC 30V/1A (AC/DC).
oExternal power supply input 12VDC(±15%)/2A.
oOutput LINEOUT (1VRMS).
oInternal microphone connector and GetFace bus
connector.
•Reset button and LED indicators (yellow, red, green).
•Ambient conditions:
oOperation: -40..60ºC y 10..95%RH (without condensation)
oStorage: -40..70ºC y 10..95%RH
•Protection index: IP54
•Camera11280x960px (angles 120ºH, 90ºV, 145ºD) and
IR light
•Speaker 2W. Sound pressure (1 kHz, 1m): 78 dB.
•Static or dynamic IP (DHCP compatible)
1 Only included in the ZVP-CAM unit.
ASSEMBLY INSTRUCTIONS
1 Depending on the installation type (surface or flush-mount),
the initial installation zone is different.
2 Please remove the blind panel from the basic unit.
1. Basic Unit 2. Board connections 3. Space for additional modules 4. Internal microphone
5. Camera
6. Infrared LED
7. Button 8. Blind panel 9. Allen key 10. Auxiliary metallic parts
OUT
Flush-mount installation:
For 12VAC/DC electromagnetic lock, it is
necessary to protect the intercom against
voltage peak while switching off the induction
load. For this way of protection, please,
connect the varistor like is showed in the next
figure near to the lock.