manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Zennio
  6. •
  7. Intercom System
  8. •
  9. Zennio ZVP-CAM Guide

Zennio ZVP-CAM Guide

Other manuals for ZVP-CAM

1

This manual suits for next models

1

Other Zennio Intercom System manuals

Zennio GetFace IP ZVPFFRA1B User manual

Zennio

Zennio GetFace IP ZVPFFRA1B User manual

Zennio Z41 COM User manual

Zennio

Zennio Z41 COM User manual

Zennio GetFace IP ZVP-WOCAM User manual

Zennio

Zennio GetFace IP ZVP-WOCAM User manual

Zennio ZVP-CAM User manual

Zennio

Zennio ZVP-CAM User manual

Zennio GetFace IP ZVP-FFRA2 User manual

Zennio

Zennio GetFace IP ZVP-FFRA2 User manual

Zennio GetFace IP ZVP-FFRA1 User manual

Zennio

Zennio GetFace IP ZVP-FFRA1 User manual

Zennio ZVP-FFRA3 User manual

Zennio

Zennio ZVP-FFRA3 User manual

Popular Intercom System manuals by other brands

Videx VRDK1 (25H) Technical manual

Videx

Videx VRDK1 (25H) Technical manual

Auta COMPACT VISUALTECH manual

Auta

Auta COMPACT VISUALTECH manual

Aiphone LC-10S instructions

Aiphone

Aiphone LC-10S instructions

Aiphone PD-1 instructions

Aiphone

Aiphone PD-1 instructions

Aiphone JF-DVF-HID-I instructions

Aiphone

Aiphone JF-DVF-HID-I instructions

Comelit 4893M Technical manual

Comelit

Comelit 4893M Technical manual

MGL Avionics V16 manual

MGL Avionics

MGL Avionics V16 manual

SSS Siedle BVI 750-0 Installation & programming

SSS Siedle

SSS Siedle BVI 750-0 Installation & programming

urmet domus AIKO 1716/1 quick start guide

urmet domus

urmet domus AIKO 1716/1 quick start guide

urmet domus IPerVoice 1039 Installation

urmet domus

urmet domus IPerVoice 1039 Installation

Alpha Communications STR QwikBus TT33-2 Installation, programming, and  user's manual

Alpha Communications

Alpha Communications STR QwikBus TT33-2 Installation, programming, and user's manual

Monacor ICM-20H instruction manual

Monacor

Monacor ICM-20H instruction manual

Logenex A202CR Installation & programming

Logenex

Logenex A202CR Installation & programming

Quantum QR5 Installation and programming manual

Quantum

Quantum QR5 Installation and programming manual

EVGA XR1 quick guide

EVGA

EVGA XR1 quick guide

CyberData 011211 series Installation quick reference

CyberData

CyberData 011211 series Installation quick reference

Vidos duo M1021 user manual

Vidos

Vidos duo M1021 user manual

Savant DOR-SMS-00 Deployment guide

Savant

Savant DOR-SMS-00 Deployment guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

GetFace IP
Basic Unit with or without camera
ZVP-CAM / ZVP-WOCAM Technical documentation
© Zennio Avance y Tecnología S.L. Ed. 1 Further information www.zennio.com Page. 1/ 2
FEATURES
•Connectors:
oRJ-45 Ethernet 10/100Base-TX Auto-MDIX.
It allows PoE supply 802.3af – Class 0 – 12.95W.
oIN1: Passive or active input (-30..30VDC).
0=open or VIN1>1.5VDC / 1=closed or VIN1<1.5VDC.
oOUT1: Active output (8..12VDC, IMAX=400mA).
oRELAY1: Relay contacts NO/NC 30V/1A (AC/DC).
oExternal power supply input 12VDC(±15%)/2A.
oOutput LINEOUT (1VRMS).
oInternal microphone connector and GetFace bus
connector.
•Reset button and LED indicators (yellow, red, green).
•Ambient conditions:
oOperation: -40..60ºC y 10..95%RH (without condensation)
oStorage: -40..70ºC y 10..95%RH
•Protection index: IP54
•Camera11280x960px (angles 120ºH, 90ºV, 145ºD) and
IR light
•Speaker 2W. Sound pressure (1 kHz, 1m): 78 dB.
•Static or dynamic IP (DHCP compatible)
1 Only included in the ZVP-CAM unit.
ASSEMBLY INSTRUCTIONS
1 Depending on the installation type (surface or flush-mount),
the initial installation zone is different.
2 Please remove the blind panel from the basic unit.
1. Basic Unit 2. Board connections 3. Space for additional modules 4. Internal microphone
5. Camera
1
6. Infrared LED
1
7. Button 8. Blind panel 9. Allen key 10. Auxiliary metallic parts
1
3
2
7
8
6
10
4
9
LAN
(PoE)
RG
Y
+ -
IN1
+ -
OUT1
RELAY1
+ -
12VDC
2A
RESET
BUS
LINE
OUT
MIC
LEDs
Board connections:
5
Surface installation:
Flush-mount installation:
Note:
For 12VAC/DC electromagnetic lock, it is
necessary to protect the intercom against
voltage peak while switching off the induction
load. For this way of protection, please,
connect the varistor like is showed in the next
figure near to the lock.
Terminals
Lock
© Zennio Avance y Tecnología S.L. Ed. 1 Further information www.zennio.com Page. 2/ 2
3 Place the auxiliary metallic parts supplied with the frame.
4 Place and fix the Basic Unit with the supplied screws.
5 Install the additional modules, if any, and interconnect them
through the bus cable. 6 Fix the blind panel (or the additional modules that remains
in sight) with the supplied screws and label the buttons with its
caption.
7 Place the suitable frame (surface or flush-mounted)
8 Fix the frame by using the supplied Allen key.
Surface installation:
Flush-mount installation:
Surface installation:
Flush-mount installation:
Surface installation:
Flush-mount installation: