REPAIR
1. In the power-on state, press the drain button, wait for a while, and
press it again until the water is drained.
2. Roll up the power cord and water hose and secure them in place.
3. Clean the filter.
4. Place in a cool, dry, relatively dust-free environment. Do not place in
chemical environment.
Open the back cover to repair the electrical part.
1. Electronic control maintenance
The following maintenance requires professional or qualified maintenance
personnel to perform maintenance
If the following conditions occur, please confirm the following conditions
before requesting customer service:
When you do not use this product for a long time and plan to store or
collect it, pay attention to the following steps:
DEHUMIDIFIER STORAGE
TROUBLESHOOTING
DESCRIPTION
Machine
Not Running
Does Not
Dehumidify
No Wind Enters
Loud Noise
When Running
Error Code: E1
Error Code: E4
Error Code: L0
Error Code: Hi
Water Leakage
Is the power cord properly
connected?
Is the room temperature above 5°C
or within 38°C?
Is the filter blocked?
Are the air inlets or
air outlets blocked?
Machine must operate at normal
operating temperature
Clean the filter
Is the filter blocked?
Is the machine placed at an angle?
When the LCD screen displays El,
the humidity sensor is faulty or the
wiring of the humidity sensor is not
plugged in properly or the ambient
temperature is <10 degrees or >98
degrees
When the LCD screen displays E4,
it is full water protection
When the LCD shows LO, the
humidity sensor is faulty or the
humidity sensor wiring is not
plugged in properly. or ambient
temperature ≤ 5 degrees
Clean the filter
Is the filter blocked? Clean the filter
Replace the humidity sensor or
check if the wiring is loose, and
reinsert it. If the ambient temper-
ature is <10 degrees or > 98 de-
grees, it is normal display
Dump the water in the tank or
reinstall the tank so that the float
switch can contact normally
Replace the humidity sensor or
check for loose wiring and plug
it back in again. If the ambient
temperature is 5 degrees, it is
normal display
When the LCD screen displays HI,
the humidity sensor is faulty or the
wiring of the humidity sensor is not
plugged in properly. or ambient
temperature ≥ 38 degrees
Discounted or clogged water pipes
Replace the humidity sensor or
check if the wiring is loose, and
reinsert it. If the ambient temper-
ature is ≥ 38 degrees, it is normal
display
Check the connection and status
of water pipes
Move the machine to a flat,
sturdy location
Clear the blockage from the
air inlet or outlet
Connect the plug and socket
POTENTIAL CAUSE SOLUTION
ELECTRIC
CONTROL BOX