ZHEJIANG XIANFENG MACHINERY K207A User manual

K207A SWING GATE OPENER
USER’S MANUAL
ZHEJIANG XIANFENG MACHINERY CO., LTD.

K207A Swing Gate Opener User’s Manual
Important safety information
Read the entire user’s manual before beginning installation, and carefully obey the
following instructions:
zTo prevent the risk of electrocution, be sure to turn off all power to the K207A until
installation is complete.
zThe Gate Opener should be installed by a qualified technician. Otherwise, serious
personal injury or property damage may occur.
zBefore installation, all the locks of the gate should be unlocked.
zThe auto-reverse function must be checked during installation to ensure that the gate
can auto-reverse in the event of obstruction.
zThis auto-reverse function should be regularly inspected and adjusted, if necessary.
zWhen opening or closing the gate, do not attempt to walk or drive through the gate.
Do not touch the gate while in operation.
zChildren should not be allowed to play near or operate automatic gates.
zThe maximum force that the gate opener can provide is 1500N.
zAn electric lock is provided for installation for gate lengths greater than 5 feet (1.5
meters).
zThis unit uses a current feedback system to stop. Do not operate the opener without a
solid stop block in place. This could cause injury, damage to the opener or other
personal property.
zDo not install the gate too close to the limit of travel; install the stop block with at least
three inches margin.
zThe automatic gate opener must be grounded.
zBe careful when in close proximity to moving parts where hands or fingers could be
pinched.
zDo not allow control devices to be placed so that a person can access them by
reaching through the gate.
zIn the event of power failure, an emergency release key allows you to operate the
gate manually.
zThe opener should be switched off before repairing it or opening its cover.
zPlease erase and reset the code after installing the opener.

K207A Swing Gate Opener User’s Manual
Additional features
zSupports gate leafs up to 440 lbs or 8.2 feet.
zSupports up to 25 RF remotes, 2 included.
zUser programmable and user erasable remote codes.
zRF hopping code technology prevents thieves from guessing your remote code.
zAuto-close feature is available for this opener.
zSolid steel lock.
zPush to open or pull to open configurable.
zOpening and closing time have been preset in 24 sec.
zAluminum and cast metal housing.
zFor your safety, the K207A will stop and reverse if it encounters an obstruction during
closing and stop when it encounters an obstruction during opening.
zManual key release design for emergency purposes.
Specifications
zPower Supply: AC220×(1±10%)V, 50Hz
zMotor Speed: 1400 rpm
zMotor Output: AC220V, 110W
zElectronic Lock Output: DC12V 2A
zRelay Coil Voltage: DC12V
zMCU Voltage: DC5V
zRemote Control Range: 30m, Hopping Code
zControl Box Weight: 2kg
zControl Box Dimension: 276 mm (L) x 211 mm (W) x 112mm(H)
zEnvironment Temperature: -10°C~+50°C
zAuto Close Timer: 30 ± 3 seconds
zOpening Time: < 24 seconds
zWorkingAngle of Gate: 90°or 105°
zMax. Gate Section Weight: 440 lbs. (200kg)
zMax. Gate Section Width: 8.2 feet (2.5 meters)
zDuty Cycle: 25%
zNoise: <65dB(A)

K207A Swing Gate Opener User’s Manual
Exploded View and Parts List
1.Hood pipe
2.End joint
3.Pin 10x40
4.Steel tube
5.Small support ring
6.Right housing
7.Screw M5x20
8.Locknut
9.Screw shaft
10.O seal ring 21.2x2.65
11.Bush
12.Connecting sleeve
13.Plastic split ring
14.Tapping screw ST2.9X6.5
15.Outer tube
16.Large support ring
17.Bearing 6004
18.Pin 8x35
19.27T ring gear
20.27T axle sleeve
21.Elastic circlip 14
22.Bearing 618/7
23.27T planet carrier
24. Planetary gear
25. Central gear
26. Planetary spindle
27.Corrugated gasket
28.Circlip
29.24T planet carrier
30.Bearing 61800
31.Elastic circlip 19
32.24T ring gear
33.Bearing 61800
34.Locating shield
35.Pin 4x20
36.Coupling joint
37.Motor
38.Capacitor bracket
39.Capacitor
40.Wiring base
41.Wiring terminal
42.Screw M4x8
43.Wiring cover
44.Tapping screw ST3x13
45.Joint block
46.Axle pin
47.Earth wire
48.Release key
49.Lock
50.Seal 17x2.65
51.Upper cover
52.Screw ST4.2x9.5
53.Waterproof seal
54.Hexagonal nut M5
55.Left housing
56.Waterproof seal
24
9
17
12
14
15
16
54
53 52 51
55
19
18
23
49
50 48
1
2
3
4
32
26
25 56
30
33
34
37
38
5
6
7
47
46
43
45
44
42
41
39
40
8
13
29
20
22
35 36
31
10
11
21
2728

K207A Swing Gate Opener User’s Manual
Mechanical Installation
Begin with both openers unlocked. Next identify if this will be a “push to open” or a “pull to open”
installation. In either configuration, the gate is mounted on one face of the mounting post, and the
opener is mounted on the face 90 degrees from it. Below are schematics of both “push to open” and
“pull to open” configurations.
Fig. 1 Push to Open
α
α
Close
Open
Fig. 2 Pull to Open
Gate opener
Enlarge
α
α
Close
Open

K207A Swing Gate Opener User’s Manual
The installation should meet the specifications shown in figure 3. See Fig. 3.
Fig. 3
Retainer
(close position)
Gate opener
Retainer
(open position)
Cmax
A
B
>0°
110
1020
α
A B Cmax
140
130 115
125 50
50
90°
105°
Enlarge
α
Main Structure
Fig. 4
Special motor Planetary reducer Screw shaft
Control box

K207A Swing Gate Opener User’s Manual
The installation height range is 1.18 – 3.15 inches (300 – 800mm). See Fig. 5.
Fig. 5
Electric lock
Gate
Gate opener
Gate post
Front and Rear Parts of Gate Opener
To install the rear part of the gate opener, insert shoulder screw and spacer, then tighten with the nut.
See Fig. 6.
Fig. 6
Shoulder screw
Spacer
Nut
gate opener
Supporting
bracket

K207A Swing Gate Opener User’s Manual
To install the front part, fit the hole in the front part with the hole in the supporting plate, and push the
axle pin into the holes (using hands or a hammer), and finally fit the retainer clip. See Fig. 7.
Fig. 7
Retainer clip
Front part of gate opener
Axle pin
Supporting plate
Wiring
Screw off the two stainless tapping screws, and then remove the cover and wiring as shown in Fig. 8.
WARNING: Follow the wiring diagram precisely. Failure to do so could cause damage to the gate
opener controller.
Fig. 8
M
V
UW
Upper cover
Enlarge
Stainless tapping screw

K207A Swing Gate Opener User’s Manual
Hood Shield
Install the hood pipe, tighten the screws into the opener and cover the plastic split ring over the joint.
See Fig. 9.
Fig. 9
Screw
Main unit Hood pipe
Hoodpipe
Plastic split ring
Waterproof caps
There are 8 caps in total 4 to be used and 4 spares. When the gate opener is installed, the caps are
used to cover the upper holes of the unit to avoid leakage. See Fig. 10.
Fig. 10
W aterproof cap
Gate opener
Retainer – Closed and Opened Positions
Close the gate section to its fully closed position; fix the retainer according to the position of the gate
section. NOTE: Each section is completed separately. See Fig. 3.

K207A Swing Gate Opener User’s Manual
If the maximum angle for installing is 105°, the retainer should be installed on the ground at approx.
100°. If the installing angle is 90°, the retainer should be installed at 90°. See Fig. 3.
Electric Lock
If the gate section is >5 feet (1.5 meters), it is recommended that you install the electric lock. Weld
the steel plate of the lock to the gate, and then fix the lock. See Fig. 11 to determine the height of the
plate.
Fig. 11
A
Release here
Electric lock
Base plate
To install the base plate of the lock, fix the plate to the ground with 3 screws and make sure that the
lock pin can fit tightly in the hole in the plate.
Adjustment
The pair of gate sections will not start simultaneously. The gate section with the lock will start to
open earlier than the other gate section, so that both sections can be locked properly. A plate or tab

K207A Swing Gate Opener User’s Manual
can be welded on the gate section with the lock so that when it closes, it will trap the gate section
without the lock between itself and the center stop block, thus locking both gate sections.
Mechanical Maintenance
zCheck the screw lubricant and add #1 grease regularly to both gate actuators.
zRegularly verify that the gate swings freely and add grease regularly.
zKeep opener clean at all times.
Electrical and Control Box Installation
1. Installation
(1) Install the cable
zIn order to protect the wires, between the gate opener and the control box, armored cable,
galvanized cable or PVC pipe must be set into the concrete when it is poured. Wires within the
cable shall be located or protected so that no damage can result from contact with any rough or
sharp part. The diameter of the cable should be more than 20mm, the wire size inside the cable
should be more than 1.0mm2.
(2) Install the control box
zThe control box circuit should be equipped with single-phase breaker (10A).
zMake sure that power is OFF before making any electrical connections.
zOpen the cover of the control box, remove the control board, and fix the control box on the wall.
See Fig. 12
zPerform the wiring and replace the cover. (See table 1 and Fig.14)
Note: (1) we regard the gate with the electrical lock as No.1 gate, the other gate as No.2 gate. (2) If
you want to use auto-close function, the gate opener must be equipped with the infrared device.
Fig. 12 mounting size

K207A Swing Gate Opener User’s Manual
Table 1 wiring between control box and gate opener
Position Tab Remark
21 (Terminal X12) L Connect live wire
21 (Terminal X12) N Connect neutral wire
21 (Terminal X12) E Connect ground wire
19 (Terminal X11) U1 Connect No.1 motor COM/U
19 (Terminal X11) V1 Connect No.1 motor V
19 (Terminal X11) W1 Connect No.1 motor W
19 (Terminal X11) C1, C1 Connect No.1 motor capacitor
18 (Terminal X10) U2 Connect No.2 motor COM/U
18 (Terminal X10) V2 Connect No.2 motor V
18 (Terminal X10) W2 Connect No.2 motor W
18 (Terminal X10) C2, C2 Connect No.2 motor capacitor
17 (Terminal X9) LAMP Connect alarm lamp
16 (Terminal X8) LOCK Connect electronic lock
(3)Install the External Keypad/Button Switch
The K207A is equipped with an interface for an external button switch or keypad. To install the
keypad attach two wires of your keypad to the O/S/C terminal. The keypad will function in single
channel mode. For three-button switch installation, use the terminals for multi-channel mode.
Three-button mode: The port ‘GND’ is the common port, the port ‘OP’ is used to open the gate, ‘CL’
is used to close the gate, and ‘ST’ is used to stop the gate. Single-button mode: connect two wires
of button switch to ‘O/S/C’ (see Fig.14 terminal X7 No.15) of control board.
(4) Safe guard (Infrared device)
If the infrared beam is broken during closing, the gates will reverse and open immediately. During
opening, the beeper will ring. The control box is not factory equipped with an infrared device.
Connect signal wire of infrared device to ‘IR’ (see Fig. 14 terminal X6, No.14), connect common wire
(i.e. ‘power supply –‘) of infrared device to ‘GND’ (terminal X6, No.14), and connect ‘power supply +’
of infrared device to ‘12V’ (terminal X6, No.14).
2. Adjustment
Fig. 13
Button 4 Button 3
Button 1 Button 2

K207A Swing Gate Opener User’s Manual
(1) Learn / erase remote controls
Adding extra remote controls (Learn): Press red button on the control board (see Fig.14 No.12), then
the ‘LED’ (see Fig. 14 No.11) will be on, it will turn off when you press any remote control button.
Press the same button, the ‘LED’ will flash at 2Hz frequency and then turn off; this indicates the
learning process is finished. If it fails to set, the ‘LED’ will turn off automatically after flashing for 1
second, you should follow the steps above to reset.
Up to 25 remote controls may be used.
To erase all remote controls: press and hold the red button on the control board until ‘LED’ turns on
and then turns off. This indicates that all the remote controls have been erased completely. You
should reprogram the remote control if you want to control this opener (see Adding extra remote
controls section).
(2) The remote control works in a single channel mode. It has four buttons. See Fig. 13. With each
press of the remote control button which has been programmed, the gate will close, stop, open or
stop cycle.
Warning: Notify the users that the gate is never to be operated unless it is in full view.
(3) Operation of the gates
The gates can be controlled by using remote control, single-button mode or three-button mode
external button switch.
zUnlock the gate opener with the key. Push the gates to the opened (retracted) position manually.
Lock the gate opener with the key
zTurn the power on.
zClose the gates by using remote control, single-button mode or three-button mode external
button switch. The No.2 gate-leaf will close first, and then the No.1 gate-leaf with electrical lock
will close after 3 seconds.
zThe gates will stop at its closed position automatically, or you can stop the gates at its closed
position by remote control, single-button mode or three-button mode external button switch. If
gates do not stop or bind before stopping, verify that the stop is firmly in place, and the force
adjustment knob for that gate on the control board is adjusted correctly. Adjust counter-clockwise
to reduce binding.
zOpen the gates by remote control, single-button mode or three-button mode external button
switch. Firstly, the electrical lock will be opened, the No.1 gate-leaf with lock will open, and then
the No.2 gate-leaf will open after 3 seconds.
zThe gates will stop at its opened position automatically, or you can stop the gates at its opened
position by remote control, single-button mode or three-button mode external button switch. If
gates do not stop or bind before stopping, verify that the stop is firmly in place, and the force
adjustment knob for that gate on the control board is adjusted correctly. Adjust counter-clockwise
to reduce binding.
zTotal working time: 24 seconds.
Note: The gate will return to open if press ‘OPEN’ button on the three-button mode external button
switch during closing, the beeper will ring. We call this Open priority.

K207A Swing Gate Opener User’s Manual
(4) Auto-reverse function
Turning the auto-reverse safety function: Rotating the ‘FORCE ADJ’ (see Fig.14 No.4 and No.5) with
a screwdriver, No.4 force adjustor can be used to adjust No.1 gate-leaf which has lock, No.5 force
adjustor can be used to adjust No.2 gate-leaf.
It is very important that you tune the safety reverse function on your gate opener. Power the control
box if it is not already and verify that you have completed the remote programming exercise. When
properly adjusted, the gate should close and stop when it hits the stop block without overly forcing the
gate, and reverse if it strikes an object before it reaches its stop. An alarm should sound if it activates
the auto reverse. Use a screw driver to rotate the Force Adj. knob. Rotating clockwise will increase
the resistance needed to trip the safety reverse function. Rotating counter-clockwise will decrease
the resistance. If the gate does not move when activated, or auto reverses without striking an obstacle,
then the resistance setting may be too little. If the gate does not stop when an obstruction is placed in
its path, then the setting may be too high.
(5) Auto-close function
Turn on the fourth dip-switch (See Fig.14 No.13) to ON position, the gates will stay open for 30±3
seconds before automatically closing. Factory preset: the fourth dip-switch is in the OFF position, i.e.
the auto-close function is shut off. An Infrared device is required to be installed for safety if the
auto-close feature is enabled.
(6) Safe guard (Infrared device)
If infrared beam is broken during closing, the gates will reverse and open immediately.
During opening, the beeper will ring. The control box is not factory equipped with an infrared device.
(7) Control board diagram see Fig.14.

K207A Swing Gate Opener User’s Manual
Fig.14 control board diagram

K207A Swing Gate Opener User’s Manual
Table 2 wiring notes of control board
Position Function Remark
1 Transformer input AC220V
2 Transformer output AC12V
3 Fuse 5
×
20 2A
4 Force adjustor (for No.1 gate-leaf with
electrical lock)
The resistance may be increased or
decreased by rotating clockwise or
anticlockwise.
5 Force adjustor (for No.2 gate-leaf) The resistance may be increased or
decreased by rotating clockwise or
anticlockwise.
6 Beeper 12V
7 Antenna Impedance: 50Ω
8 Receiver panel Receive signals
9 Memory card It can be unplugged, it is used to store
signals.
10 Power indicator light (LED1) 1206 green
11 Indicator light (LED) 1206 red
12 Learn button 6
×
6 red
13 Dip-switch Set auto-close function
14 External device interface Connect infrared device
15 External button switch/keypad interface Connect external button switch/keypad
16 Electrical lock interface DC12V
17 Alarm lamp interface AC220V
18 Motor and Capacitor interface Connect No 2 motor
19 Motor and Capacitor interface Connect No 1 motor
20 Fuse 5
×
20 10A
21 Power supply AC220V 50Hz

K207A Swing Gate Opener User’s Manual
3. Troubleshooting (see Table 3)
Table 3 Troubleshooting
Symptoms Possible cause Remedy
Gate will not open or close (1) Power is OFF.
(2) The gate is obstructed.
(3) Force Adj. is set too low.
(1) Make sure that power is ON.
(2) Remove obstructions.
(3) Rotate force adjustment knob
clockwise
Gate fails to reverse. (1) The ‘FORCEADJ’ is adjusted
too high. (1) Adjust ‘FORCE ADJ’
anticlockwise to decrease force.
Gate begins to close, then
reverses.
(1) The ‘FORCEADJ’ is adjusted
too low.
(2) The gate is obstructed.
(1) Adjust ‘FORCE ADJ’ clockwise
to increase force.
(2) Remove obstructions.
Remote control does not
work
(1) The indicator light of remote
control does not light.
(2) Remote control is not suitable
for receiver.
(3) Receiver panel.
(1) Battery level may be low,
replace the battery inside the
remote control.
(2) After making sure the codes
are correct, erase remote controls
and then re-program the remote
control.
(3) Check the receiver panel,
make sure it is plugged in at the
control board.
Gate running direction is
not correct, or gates run in
different directions.
(1) Wiring is incorrect.
(1) Please change wires “V1 and
W1”or “V2 and W2”. If the wiring
between two gates is wrong and
the gates cannot work, please
check the wiring between “U1, V1,
W1”and “U2, V2, W2”.
Other ZHEJIANG XIANFENG MACHINERY Gate Opener manuals
Popular Gate Opener manuals by other brands

FAAC
FAAC Safe Zone S418 user manual

On Automation
On Automation CRONO SL600 instruction manual

Rossi
Rossi DZ GHT9 Installation

Platinum Access Systems
Platinum Access Systems BLSW1016-B Installation instructions & owner's manual

WORKMASTER
WORKMASTER GO-A13-HA Operator's guide

Beninca
Beninca BULL 20T Operating instructions and spare parts catalogue