ZIEHL-ABEGG A-G-247NW User manual

A-G-247NW
Part.-No. 380090
Hand held terminal
Operating Instructions
Software version: from Version 8.05
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
english

Content
1 General notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Structure of the operating instructions . . . . . . . . . . . . . . . . . . . . 3
1.2 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3 FCC / IC Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.2 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.3 Disposal / recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4 Structure of the terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.1 Components / connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.2 Voltage supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.3 MODBUS (RS-485) interface . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.1 Display and operating elements of the terminal . . . . . . . . . . . . . 9
6 Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.1 Overview mainmenu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.2 AM-MODBUS App's . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.2.1 Configuration Online . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.2.2 Auto Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.2.3 Load Paramterset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.2.4 Device Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6.3 AM-PEMIUM App's . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6.3.1 Configuration Online . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6.4 AXG Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
6.5 USB Filetransfer, only AM-MODBUS(-W) . . . . . . . . . . . . . . . . . . 16
6.6 USB COMPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6.7 A-G-247 Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
7.1 Manufacturer reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7.2 Service information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Operating Instructions A-G-247NW
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
2/21

1 General notes
1.1 Structure of the operating instructions
Before installation and start-up, read this manual carefully to ensure correct use!
We emphasize that these operating instructions apply to specific units only, and
are in no way valid for the complete system!
Use these operating instructions to work safely with and on the device. They contain
safety instructions that must be complied with as well as information that is required for
failure-free operation of the device.
Keep these operating insturctions together with the device. It must be ensured that all
persons that are to work on the device can refer to the operating instructions at any time.
1.2 Exclusion of liability
To allow for future developments, construction methods and technical data given are
subject to alteration. We do not accept any liability for possible errors or omissions in the
information contained in data, illustrations or drawings provided.
We accept no liability for damage caused by misuse, incorrect use, improper use or as a
consequence of unauthorized repairs or modifications.
1.3 FCC / IC Statements
FCC Compliance (US)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:(1) this device may not cause harmful interference, and(2) this device
must accept any interference received, including interference that may cause undesired
operation.
Note: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio fre-
quency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
FCC Warning
Changes or modifications not expressly approved by the party responsible for compli-
ance could void the user's authority to operate the equipment.
IC Compliance (Canada)
This device complies with Industry Canada licence-exempt RSS standard(s). Operation
is subject to the following two conditions: (1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause
undesired operation of the device.
Operating Instructions A-G-247NW General notes
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
3/21

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1)
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compro-
mettre le fonctionnement.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
2 Safety instructions
Attention!
•These operating instructions are valid only in combination with the device's
operating instructions which can controlled by these terminal. The remarks con-
cerning safety, installation and connection described in those operating instruc-
tions must be followed!
•Persons entrusted with the planning, installation, commissioning and maintenance
and servicing in connection with the device must have the corresponding
qualifications and skills for these jobs. In addition, they must be knowledgeable
about the safety regulations, EU directives, rules for the prevention of accidents
and the corresponding national as well as regional and in-house regulations.
•The equipment is to be used solely for the purposes specified and confirmed in the
order. Other uses which do not coincide with, or which exceed those specified will
be deemed unauthorised unless contractually agreed. Damages resulting from
such unauthorised uses will not be the liability of the manufacturer. The user will
assume sole liability.
•It is strictly forbidden for work to be carried out on any components while they are
connected to live voltage.
•The owner is obliged to ensure that the device are operated in perfect working
order only.
•Never clean electrical equipment with water or similar liquids.
Operating Instructions A-G-247NW Safety instructions
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
4/21

3 Product overview
3.1 Function
Terminal for setting of compatible Ziehl-Abegg devices.
The connection to the member is made by a connecting cable (RS-485 interface) or
wirelessly by means of radio.
Parameter sets of devices with integrated AM-MODBUS(-W) type communication mod-
ule can be saved in the terminal and transferred to other devices.
It is possible to save and exchange parameter sets with a PC via the terminal’s USB
interface.
Information
The terminal software is continuously developed and improved.
Ziehl-Abegg will provide free firmware upgrades for downloading in future.
3.2 Storage
•The device must be stored in its original packaging in a dry and weather-proof
room.
•Avoid exposure to extreme heat and cold.
•Avoid over-long storage periods (we recommend a maximum of one year).
3.3 Disposal / recycling
Disposal must be carried out professionally and environmentally friendly in accordance
with the legal stipulations.
Operating Instructions A-G-247NW Product overview
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
5/21

4 Structure of the terminal
4.1 Components / connection
17.12.2012
v_a-g-247nw_spg.vsd
1
2
3
6
5
+ 3,3 V
IRDA-RXD
IRDA-TXD
IRDA-SD
A
(D+)
B
(D-)
GND
+ 5 V
B
(D-)
GND A
(D+)
4
Mini-B (5 pin)
24V
STOP
MODBUS
(RS-485)
1 Plug power supply unit
2 Connection voltage supply / USB interface for filetransfer
3 Connection to the terminal line-commutated. Do not connect the
|
24 V
|
at the terminal!
4 Terminal connection of compatible Ziehl-Abegg device
5 Rechargeable battery compartment lid
6 Mignon accumulators (NiMh 1.2 V)
4.2 Voltage supply
The voltage supply of the terminal is made by the internal accumulators or the plug
power supply unit.
The device switches off automatically if the plug power pack is left connected with fully
charged batteries and no key is pressed for about 1 minute.
Attention!
•Only rechargeable Mignon batteries (NiMh 1.2 V) may be used. These are
automatically loaded when the power supply unit is plugged-in.
•There is a risk of fire and explosion if non-rechargeable batteries are used and the
power supply unit is plugged in!
•It is only permissible to operate or load the terminal with the plug power pack
contained in the scope of supply.
Operating Instructions A-G-247NW Structure of the terminal
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
6/21

4.3 MODBUS (RS-485) interface
The device comes equipped with a RS-485 interface for networking via MODBUS.
Conntection at: “A (D+)”, “B (D-)” and “GND”.
Example for devices with MODBUS connection and automatic addressing
04.03.2013
v_modbus_net_autoadr.vsd
ECblue MODBUS
ID1 GND A
(D+)
B
(D-) ID2GND A
(D+)
B
(D-)
B
(D-) ID1 GND A
(D+)
B
(D-) ID2GND A
(D+)
A-G-247NW
+ 3,3 V
1 2
IRDA-RXD
IRDA-TXD
IRDA-SD
A
(D+)
B
(D-)
GND
+ 5 V
3...63
ECblue MODBUS
MODBUS
(RS-485)
MODBUS
(RS-485)
Addressing
Addressing
MODBUS
(RS-485)
MODBUS
(RS-485)
Addressing
Addressing
MODBUS
(RS-485)
The connection is made at the terminals: A (D+), B (D-) and GND.
Connection of the users via the terminals: A (D+), B (D-), GND and ID1 / ID2
Information
•You must ensure correct connection; i.e. “A (D+)” must also be connected on the
following devices to “A (D+)”. The same applies to “A (D+)”.
•In addition, a "GND" connection must be established, as dissimilar potential (over
10 V!) will lead to the destruction of the RS-485 interface (e.g. lightning).
•Pay attention to sufficient distance from powerlines and motor wires (min. 20 cm).
•A maximum of 63 users can be connected directly with each orther in automatic
adressing.
•Another 63 users are connected by a repeater in manual addressing (no connec-
tion of connections “ID1”, “ID2”).
•When using the automatic addressing, no repeaters can be used because these
do not pass the signal through to the addressing.
Operating Instructions A-G-247NW Structure of the terminal
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
7/21

Example for MODBUS connection
The data line must be conducted from one device to the next. No other type of wiring is allowed!
Always use only two wires of one lead (twisted pair) for the connection.
Recommended wire types
1. CAT5 / CAT7 cables
2. J-Y (St) 2x2x0.6 (telephone wire)
3. AWG22 (2x2 twisted pair)
Max. allowed wire length 1000 m (CAT5/7 500 m).
When using telephone flex with four cable cores, we recommend the following
allocation:
•A (D+) red
•B (D-) black
•ID1 - ID2 yellow
•GND white
Default interface parameter
•Baudrate 19200
•Bits 8
•Parity Even
•Stop bits 1
•Handshake none
Information
•If any matters are unclear, please contact our V-STE support department for
control systems - ventilation technology. The information sheet “Network structure
of MODBUS” R-TIL08_01 contains detailed information about “MODBUS”.
•The MODBUS register description can be found on our homepage for download-
ing. Enter “MODBUS” under search term for this if required.
Operating Instructions A-G-247NW Structure of the terminal
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
8/21

5 Operation
5.1 Display and operating elements of the terminal
Hand held terminal type A-G-247NW
01.03.2013
v_bed_men_a-g-247nw_rd3.vsd
1
2
3
56
4
8
10
9
OFF
7
ON
AM-MODBUS APP`s
AM-PREMIUM App’s
AXG Mode
USB Filetransfer
USB COMPORT
A-G-247NW Setup
Mainmenu X
1 Switch on terminal
2 Program key and open menu
3 Menu selection, increase value
4 Menu selection, reduce value
5 From each menu (member) directly back to the display for “Speed”
6 Escape exit menu for settings (user), cancel input
7 - Select type of user
- back to selection of user (exit application)
- Switch off terminal (keep key pressed for a few seconds)
8 "Main menu" momentarily active menu level (
|
>>>
|
batteries being charged,
|
-
|
full)
9 Selection option of the sub-menu (display in menu language English)
10 Key not assigned (soft key, program-dependent function)
Explanation of display (menu User)
04.05.2009
v_display_erkl_a-g-247nw.vsd
11
1
2 3 4 5 6 7 8 9 10
12
13
Display of symbols depending on the
type of member and used communica-
tion module.
1. Numeric display 5 digit
2. Moon-Symbol for set point 2 (only AM-PREMIUM)
3. Current derating active
4. Alarm-Symbol (
member's operating instructions)
5. Brake motor or motor heating active
6. Fire-Symbol for heating operation (only AM-PRE-
MIUM)
7. Temperature management active
8. No connection to Modul (only AM-MODBUS)
9. Quench mode active
10. STOP-Symbol (enable)
11. Bargraph Fanlevel
12. Text line 3 figures (display unit, etc.)
13. Text line 16 figures (display text menu.)
Operating Instructions A-G-247NW Operation
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
9/21

6 Programming
6.1 Overview mainmenu
Mainmenu Exit menu with the top left key ◄.
▼ ▲
AM-MODBUS APP`s P → ▼ ▲→ P ▼ ▲→ P
Configuration online
RS-485
Programming of devices with integrated communication mod-
ule AM-MODBUS (RS-485).
Wireless
Programming of devices with integrated communication mod-
ule AM-MODBUS-W (wireless).
Auto Addressing Automatic addressing of the members in the MODBUS net-
work.
Load Parameterset Load paramterset from terminal to AM-MODBUS(-W).
Device Check Checking of the members in the network (as of version 9.00).
▼ ▲
AM-PREMIUM App’s P → P ▼ ▲→ P
Configuration online
RS-485
Programming of devices with integrated universal control
module AM-PREMIUM (RS-485).
Wireless
Programming of devices with integrated universal control
module AM-PREMIUM-W (wireless).
▼ ▲
AXG Mode P → ▼ ▲→ P
247
Operation of Ziehl-Abegg devices with RS-485 MODBUS
interface without built in Add-on module AM-MODBUS(-W)
or AM-PREMIUM(-W)!
▼ ▲
USB Filetransfer P
USB Filetransfer Filetransfer terminal ↔ PC via USB
▼ ▲
USB COMPORT P → ▼ ▲→ P
RS-485 Interface converter USB ↔ RS-485
Wireless Interface converter USB ↔ wireless
▼ ▲
A-G-247NW Setup P → ▼ ▲→ P
Start Basic settings for terminal
Operating Instructions A-G-247NW Programming
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
10/21

6.2 AM-MODBUS App's
6.2.1 Configuration Online
Configuration online Open menu with the P key and close it again with the top left key ◄.
Interface Select type of interface with the ▼ + ▲ keys and confirm with the P key.
RS-485 Programming of devices with integrated communication module AM-
MODBUS (RS-485).
Wireless Programming of devices with integrated communication module AM-
MODBUS-W (wireless).
Establish connection to member
Select device Setting for the device address
247
The device address is factory set to the highest available MODBUS address:
247
•Confirm the factory set address “247” with the P key for the first
connection.
•For members with changed addresses, set these from 001 to 246 with
the ▼ + ▲ keys and confirm with the P key to make the connection.
RF Network Key Radio control key only for wireless communication
9999
•Confirm the factory set radio key “9999” for the first connection.
•For members with a changed radio key, set this with the ▼ + ▲ keys
and confirm with the P key to make the connection.
BASIC-247 Example of correctly set address: 247
☻Successful connection!
BASIC-246 Example of incorrectly set address: 246
?
No connection!
Settings are not possible!
In the display the two symbols for alarm and antenna appear
Cause: wrong address, no connection via wire and/or radio
Operating Instructions A-G-247NW Programming
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
11/21

6.2.2 Auto Addressing
Auto Addressing Automatic addressing
Open menu with the P key and close it again with the top left key ◄.
Start
PStart automatic addressing with the P key.
Please Wait
Count: 0
Done
The number of the addressed members is displayed as a result.
For further details
see AM-MODBUS(-W) operating instructions.
6.2.3 Load Paramterset
Information
Befopr a parameter set can be loaded into the terminal, this must be saved in the AM-
MODBUS(-W) (
menu group “Start” / “SAVE”).
Load Parameterset Open menu with the P key and close it again with the top left key ◄.
PIN input PIN input. In the download only parameters for the entered authorisation are
considered (
operating manual AM-MODBUS).
•PIN 0010: Opening service menu (Controller Setup, IO Setup, Motor
Setup), for programmed access level <2.
•PIN 1234: Opening user menu (Setting) for programmed access
level <1.
•PIN 3698: Assumption of the communication parameters (Address,
Com Baudrate, Com. Mode).
0000
Interface Select used interface:
RS-485 For members with integrated communication module AM-MODBUS (RS-
485).
Wireless For members with integrated communication module AM-MODBUS-W (wire-
less).
Select device Select the address of the desired member with the ▼ + ▲ keys and confirm
with the P key.
247
RF Network Key Wireless
Only for communication wireless:
Select radio control key with the ▼ + ▲ keys and confirm with the P key.
9999
Parameterset
Files
Operating Instructions A-G-247NW Programming
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
12/21

Empty directory! Display as long as no parameter set is saved in the member’s AM-
MODBUS(-W) yet.
ECBLUEX.CSV
TEST01.CSV
TEST02.CSV
Select desired parameter set with the ▼ + ▲ keys and confirm with the P
key.
Parameterset
Press the P key to start download.
File: TEST01.CSV
Start Download
P
Download OK! Exit menu with the top left key ◄.
6.2.4 Device Check
The networked members can be tested with this function (as of version 9.00).
Device Check Open menu with the P key and close it again with the top left key ◄.
Interface Select used interface:
RS-485 For members with integrated communication module AM-MODBUS (RS-
485).
Wireless For members with integrated communication module AM-MODBUS-W (wire-
less).
Device Count Enter the number of devices (max. 64) with the ▼ + ▲ keys and confirm with
the P key.
If the automatic addressing was performed first, the number of detected
devices is taken over.
006
RF Network Key Wireless
Only for communication wireless:
Select radio control key with the ▼ + ▲ keys and confirm with the P key.
9999
Device Check
Start the test procedure with P.
Start
P
Device Check
Every device from address 1 to the number “Device Count” is queried
(product code, version, error status).
•Devices that reply are displayed with product name and version.
•The device has an error if an exclamation mark is displayed.
•Everything is OK if a checkmark is displayed!
1: ECblue 11.05 √
2: ECblue 9.05 √
3: ECblue 11.05 √
4: ECblue 11.05 !
5: ECblue 11.05 √
6: ECblue 11.05 √
Operating Instructions A-G-247NW Programming
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
13/21

Show Details
Device Check
Every member can be selected and marked with the ▼ + ▲ keys, the exact
reason for the error is displayed by “Show Details” after pressing the ◄ key.
OK appears if there is no error!
1: ECblue 11.05 √
2: ECblue 9.05 √
3: ECblue 11.05 √
4: ECblue 11.05 !
5: ECblue 11.05 √
6: ECblue 11.05 √
Show Details
Device Check
If the devices are not available, “Timeout” appears after 500 ms in this
process.
1: Timeout !
2: Timeout !
3: Timeout !
4: Timeout !
5: Timeout !
6: Timeout !
Show Details
6.3 AM-PEMIUM App's
6.3.1 Configuration Online
Configuration online Open menu with P-key.
Interface Select type of interface with the ▼ + ▲ keys and confirm with the P key.
RS-485 Programming of devices with integrated universal control module AM-PRE-
MIUM (RS-485).
Wireless Programming of devices with integrated universal control module AM-PRE-
MIUM-W (wireless).
Establish connection to member
Select device Setting for the device address
247
The device address is factory set to the highest available MODBUS address:
247
•Confirm the factory set address “247” with the P key for the first
connection.
•For members with changed addresses, set these from 001 to 246 with
the ▼ + ▲ keys and confirm with the P key to make the connection.
Operating Instructions A-G-247NW Programming
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
14/21

RF Network Key Radio control key only for wireless communication
9999
•Confirm the factory set radio key “9999” for the first connection.
•For members with a changed radio key, set this with the ▼ + ▲ keys
and confirm with the P key to make the connection.
PREMIUM-247 Example of correctly set address: 247
☻Successful connection!
PREMIUM-246 Example of incorrectly set address: 246
?
No connection!
Settings are not possible!
Cause: wrong address, no connection via wire and/or radio
6.4 AXG Mode
Operation of Ziehl-Abegg devices with RS-485 MODBUS interface without built in Add-
on module AM-MODBUS(-W) or AM-PREMIUM(-W)!
Alternatively to the use of an external terminal type AXG-1A(E).
AXG Mode Open menu with P-key.
Select device
247
The device address is factory set to the highest available MODBUS address:
247
•Confirm the factory set address “247” with the P key for the first
connection.
•Set changed addresses from 001 to 246 with the ▼ + ▲ keys and
confirm with the P key to make the connection.
For further details about the operation
, see the operating instructions of the con-
nected device.
Operating Instructions A-G-247NW Programming
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
15/21

6.5 USB Filetransfer, only AM-MODBUS(-W)
USB Filetransfer Open menu with P-key.
Filetransfer
USB
Filetransfer
Connection
Memory: 1018 MB
Filetransfer terminal ↔ PC via USB.
•The parameter sets saved in the terminal can be accessed by a PC via the USB
interface.
•5- pole “Mini-B” connection on the terminal (same connection as for the charger).
The necessary connecting cable is not included!
•After activating the function “USB file transfer” with the P key, the “Windows
Explorer” is opened automatically (if not, open Windows Explorer manually).
•Under
|
Storage media
|
the
|
CSV
|
folder is displayed.
•The
|
CSV
|
folder contains the tables with the parameter sets saved in the
terminal.
Example:
–ECBLUEX.CSV
–TEST01.CSV
–TEST02.CSV
•These can be copied to the PC for backup and administration.
•A parameter set which already exists on the PC can be copied back into the
terminal’s
|
CSV
|
folder if necessary.
•With the “Load parameter set” function it is possible to transfer these settings to
other devices.
Save the parameter sets in the terminal.
Operating Instructions AM-MODBUS(-W) -> Menu group “Start” -> Menu “SAVE”.
Attention!
This function serves to save parameter sets and transfer them to other members.
Only change values in the CSV file is you have exact knowledge of the function!
Operating Instructions A-G-247NW Programming
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
16/21

Example: Parameter set transferred from ECblue 001 to ECblue 002
MODBUS
AM-MODBUS
Inside
AM-MODBUS
Inside
AM-MODBUS
Inside
Mini-B (5 pin)
USB
device: 001
Parameterset: ECBLUEX
3 USB Filetransfer -> P-> USB Filetransfer
File X Name
ECBLUEX.CSV
TEST01.CSV
TEST02.CSV
TEST03.CSV
device: 002
Parameterset: ECBLUEX
device: 003
Parameterset: …..
01.03.2013
v_appl_a-g-247nw_usb.VSD
1ECblue -> AM-MODBUS -> 001->Speed -> Start -> P
2ECblue -> Load Parameterset -> PIN Input-> RS-485 -> Select device: 002
-> Files -> Start Download
Files
ECBLUEX.CSV
TEST01.CSV
TEST02.CSV
TEST03.CSV
Parameterset IXI
AM-MODBUS APP`s
AM-PREMIUM App’s
AXG Mode
USB Filetransfer
USB COMPORT
A-G-247NW Setup
Mainmenu X
USB Filetransfer
1 Name parameter set of ECblue 001 and save in the terminal:
ECblue -> AM-MODBUS -> 001 -> Speed -> Start -> SAVE
2 Load Parameterset to ECblue 002 :
ECblue -> Load Parameterset -> PIN Input -> RS-485 -> Select device -> Files -> Start Down-
load
3 Access via PC to saved parameter sets in the terminal:
USB file transfer -> P -> file transfer
Operating Instructions A-G-247NW Programming
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
17/21

6.6 USB COMPORT
USB COMPORT Open menu with P-key.
Interface Select type of interface with the ▼ + ▲ keys and confirm with the P key.
RS-485 Interface converter USB ↔ RS-485
Wireless Interface converter USB ↔ wireless
USB COMPORT
•Make the connection to the USB interface on the PC.
•Follow the further instructions on the screen until installation is
complete.
USB
VIirtual COMPORT
Connecting
Mini-B (5 pin)
USB
01.03.2013
v_a-g-247_comport.VSD
AM-MODBUS APP`s
AM-PREMIUM App’s
AXG Mode
USB Filetransfer
USB COMPORT
A-G-247NW Setup
Mainmenu X
USB Filetransfer
RS-485
wireless
««««««««««»»»»»»»»»»
Operating Instructions A-G-247NW Programming
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
18/21

6.7 A-G-247 Setup
A-G-247NW Setup Open menu with the P key and close it again with the top left key ◄.
A-G-247NW Setup
P ↓↑
Start
- - - - -
PIN input
PIN 9095
Restore factory setting delivery status
▼ ▲
Language GB
Language
Menu language by the factory set to English.
In this menu different national languages can be se-
lected (D German, GB English).
▼ ▲
1.05
A-G-247NW
Device name
Display of device name and software version
▼ ▲
A-G-247NW Setup
P ↓↑
Display
0
Light at Battery
Lighting intensity in battery operation
Setting range: 0 - 10
0 without background lighting
10 max. lighting intensity
▼ ▲
0
Contrast
Contrast of Display
Setting range: -2...+2
-2 minimal contrast
+2 maximal contrast
▼ ▲
▼ ▲
A-G-247NW Setup
P ↓↑
COMM Setup
19200
RS-485 Baudrate Setting range: 4800 / 9600 / 19200 / 38400
▼ ▲
8EI
RS-485 Mode Setting range: 8E1 / 8N1
▼ ▲
Operating Instructions A-G-247NW Programming
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
19/21

0
RF channel Setting range: 0 - 15
7 Technical data
Hand held terminal
Type A-G-247NW
Part.-No. 380090
Voltage supply 5 V DC
Current consumption charge 1200 mA
LC-Display Graphic display 128 x 64 pixels, LED lighting white
Housing Cover ABS, bottom part ABS, seal TPE
Protection class IP20 according EN 60529
Dimensions(W x H x D) 159.4 x 33.5 x 77.9 mm
Weight 0.42 kg
Permissible ambient temperature 0...40 °C
Permissible rel. humidity 85 % no condensation
Interference emission according EN 61000-6-3 (domestic household applications)*
Interference immunity according 61000-6-2 (industrial applications)*
* Only in connection with the plug power pack supplied by Ziehl-Abegg
Plug power supply unit
Type SYS1421-0605-W2E
Part.-No. 00161410
Output voltage 5 V DC
Output current 1200 mA
Secondary plug Mini USB - type B
Housing Cover ABS, bottom part ABS, seal TPE
Protection class IP20 according EN 60529
Dimensions(W x H x D) 64 x 24 x 78 mm
Weight 0.085 kg
Permissible ambient temperature 0...40 °C
Permissible rel. humidity 85 % no condensation
Operating Instructions A-G-247NW Technical data
L-BAL-E184-GB 1309 Index 002 Part.-No. 00163401-GB
20/21
Table of contents
Popular Touch Terminal manuals by other brands

Assa Abloy
Assa Abloy Effeff ePED 1386D10 Installation and operating instructions

TeleVideo
TeleVideo 9220 Operator's manual

Huawei
Huawei EchoLife EG8240H5 quick start

UTC RETAIL
UTC RETAIL ultimatouch 1800 series installation guide

Allen-Bradley
Allen-Bradley FLEX I/O SCANport 1203-FB installation instructions

Intermec
Intermec 5900 SERIES user guide