manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ZIGBEE
  6. •
  7. Switch
  8. •
  9. ZIGBEE In-wall Switch User manual

ZIGBEE In-wall Switch User manual

push
swi tch
LL NN
OUT
L
N
A1-A2: 8 -2 30 V
AC 100-240V
Reset
AC ZigBee In-wall Switch 09.ZG09SAP.04736
Function introduction
Important: Rea d All Inst ruc tio ns Pr ior t o Ins tal lat ion
“Reset” Key: for
network pairing,
touchlink, factory
reset of the switch,
turn on/off the load
AC 100-240V power input
push
switch
LL NN
OUT
L
N
A1-A2: 8-230 V
AC 100- 240V
1 CH 100-240VAC output
• ZigBee in-wall switch based on latest ZigBee 3.0 protocol
• 100-240VAC Wide Input and Output Voltage
• Supports resistive loads and capacitive loads
• 1 Channel Output, Up to 400W
• Input and Output with Screw Terminals, Safe and Reliable
• Enables to control ON/OFF of connected load
• ZigBee end device that supports Touchlink commissioning
• Can directly pair to a compatible ZigBee remote via Touchlink without coordinator
• Supports self-forming zigbee network without coordinator and add other devices to the network
• Supports find and bind mode to bind a ZigBee remote
• Supports zigbee green power and can bind max. 20 zigbee green power remotes
• Compatible with universal ZigBee gateway products
• Can be controlled by universal 8-230V input single wire push switch
• Mini Size, Easy to be Installed into a standard 86*86mm wall box
• Radio Frequency : 2.4GHz
• Waterproof grade: IP20
Reset
LED indicator
Input Voltage Output Voltage Output Current
Product Data
Size(LxWxH)
Compatible Load Types
Load Symbol Load Type Maximum Load Remarks
Due to variety of LED lamp
designs, maximum number
of LED lamps is further
dependent on power factor
result when connected to
switch.
Maximum permitted number
of drivers is 200W divided
by driver nameplate power
rating.
LED lamps with transformers
LED drivers
Incandescent lighting,
HV Halogen lamps
Low voltage halogen
lighting with electronic
transformers
100-240VAC 1.5A max
100-240VAC 45.5x45x20.3mm
200W @ 220V
100W @ 110V
200W @ 220V
100W @ 110V
400W @ 220V
200W @ 110V
200W @ 220V
100W @ 110V
• DO NOT install with power applied to device.
• DO NOT expose the device to moisture.
Safety & Warnings
Operation
1.Do wiring according to connection diagram correctly.
3. Zigbee Network Pairing through Coordinator or Hub (Added to a Zigbee Network)
Step 1: Remove the device from previous zigbee network if it has already been added to, otherwise pairing will
fail. Please refer to the part "Factory Reset Manually".
Step 2: From your ZigBee Controller or hub interface, choose to add lighting device and enter Pairing mode as
instructed by the controller.
Step 3: Re-power on the device to set
it into network pairing mode
(connected light flashes twice
slowly), 15 seconds timeout, repeat
the operation.
Step 4: Connected light will blink 5
times and then stay solid on, then the
device will appear in your controller's
menu and can be controlled through
controller or hub interface.
2.This ZigBee device is a wireless receiver that communicates with a variety of ZigBee compatible systems. This
receiver receives and is controlled by wireless radio signals from the compatible ZigBee system.
AC Power
50/60H z
ZigBee Clusters the device supports are as follows:
Input Clusters
0x0000: Basic 0x0003: Identify 0x0004: Groups 0x0005: Scenes 0x0006: On/off
0x0b05: Diagnostics
Output Clusters
0x0019: OTA
push
swi tch
LL NN
OUT
L
N
A1-A2: 8 -2 30 V
AC 100-240V
Reset
pus h
switch
LL NN
OUT
L
N
A1-A2: 8 -2 30 V
AC 100-240V
Reset
push
swi tch
LL NN
OUT
L
N
A1-A2: 8 -2 30 V
AC 100-240V
Reset
push
swi tch
LL NN
OUT
L
N
A1-A2: 8 -2 30 V
AC 100-240V
Reset
4. TouchLink to a Zigbee Remote
5. Removed from a Zigbee Network through Coordinator or Hub Interface
From your ZigBee controller or hub
interface, choose to delete or reset the
lighting device as instructed. The
connected light blinks 3 times to indicate
successful reset.
AC Power
50/60Hz
Step 4: There shall be indication
on the remote for successful link
and connected light will flash
twice.
Zigbee
Remote < 10cm
Step 2: Bring the remote or touch
panel within 10cm of the lighting
device.
Step 3: Set the remote or touch
panel into Touchlink
commissioning,
please refer to corresponding
remote or touch panel manual to
learn how.
Note: 1) Directly TouchLink (both not added to a ZigBee network), each device can link with 1 remote.
2) TouchLink after both added to a ZigBee network, each device can link with max. 30 remotes.
3) For Hue Bridge & Amazon Echo Plus, add remote and device to network first then TouchLink.
4) After TouchLink, the device can be controlled by the linked remotes.
6. Factory Reset Manually
Step 2: Connected light
will blink 3 times to
indicate successful reset.
AC Power
50/60H z
Step 1: Short press “Reset.”
key for 5 times continuously
or re-power on the device for
5 times continuously if
the “Prog.” key is not
accessible.
Note: 1) If the device is already at factory
default setting, there is no indication
when factory reset again .
2) All configuration parameters will
be reset after the device is reset or
removed from the network.
7. Factory Reset through a Zigbee Remote (Touch Reset)
Note: Make sure the device already added to a network, the remote added to the same one or not added to any
network.
AC Power
50/60H z
Step 1: Re-power on the
device to start TouchLink
Commissioning, 180
seconds timeout, repeat
the operation.
Step 4: There shall be indication
on the remote and connected light
flashes 3 times for successful
reset.
Zigbee
Remote < 10cm
Step 2: Bring the remote or touch
panel within 10cm of the lighting
device.
Step 3: SSet the remote or touch
panel into Touch Reset procedure
to reset the device, please refer to
corresponding remote or touch
panel manual to learn how.
8. Find and Bind Mode
AC Power
50/60H z
Step 1: Short press “Reset.”
button 3 times (Or re-power
on the device (initiator node)
3 times) to start Find and
Bind mode (connected light
flashes slowly) to find and
bind target node, 180
seconds timeout, repeat the
operation.
Zigbee
Remote
Step 2: Set the remote or touch
panel (target node) into find
and bind mode, and enable it
to find and bind initiator, please
refer to corresponding remote
or touch panel manual.
Step 3: There shall be
indication on the remote or
touch panel that it bind the
device successfully and can
control it then.to learn how.
push
switc h
LL NN
OUT
L
N
A1-A2: 8 -2 30 V
AC 100-240V
Reset
Note: Make sure the device and remote already added to the same zigbee network.
9. Learning to a Zigbee Green Power Remote
AC Power
50/60H z
Step 1: Short press “Reset.”
button 4 times (Or re-power
on the device 4 times) to
start Learning mode
(connected light flashes
twice), 180 seconds timeout,
repeat the operation.
Zigb ee
Gree n Power
Remo te
Step 2: Set the green power
remote into Learning mode,
please refer to its manual.
Step 3: Connected light will
flash twice to indicate
successful learning. Then the
remote can control the device.
Note: Each device can learn to max. 20 zigbee green power remote.
Step 1: Method 1: Short press
“Reset” button (or re-power on
the device) 4 times to start
Touchlink commissioning
immediately, 180S timeout,
repeat the operation.
Method 2: Re-power on the
device, Touchlink
commissioning will start after
15S if it’s not added to a zigbee
network, 165S timeout. Or
start immediately if it’s already
added to a network, 180S
timeout. Once timeout, repeat
the operation.
push
switch
LL NN
OUT
L
N
A1-A2: 8 -2 30 V
AC 100-240V
Reset
push
switc h
LL NN
OUT
L
N
A1-A2: 8 -2 30 V
AC 100-240V
Reset
push
swit ch
LL NN
OUT
L
N
A1-A2: 8 -2 30 V
AC 100-240V
Reset
11. Setup a Zigbee Network & Add Other Devices to the Network (No Coordinator Required)
AC Power
50/60H z
Step 1: Short press “Reset.”
button 4 times (Or re-power
on the device 4 times) to
enable the device to setup a
zigbee network (connected
light flashes twice) to
discover and add other
devices, 180 seconds
timeout, repeat the operation.
Zigbee
Remote
Step 2: Set another device or remote or touch panel into network pairing mode and pair to the network, refer to
their manuals.
Step 3: Pair more devices and remotes to the network as you would like, refer to their manuals.
Step 4: Bind the added devices and remotes through Touchlink so that the devices can be controlled by the
remotes, refer to their manuals.
< 10cm
TouchLink
10. Delete Learning to a Zigbee Green Power Remote
AC Power
50/60Hz
Step 1: Short press “Reset.”
button 3 times (Or re-power
on the device 3 times) to start
delete Learning mode
(connected light flashes
slowly), 180 seconds timeout,
repeat the operation.
Zigb ee
Gree n Power
Remo te
Step 2: Set the paired green
power remote into Learning
mode, please refer to its manual.
Step 3: Connected light will
flash 4 times to indicate
successful deleting.
Note: 1) Each added device can link and be controlled by max. 30 added remotes.
2) Each added remote can link and control max. 30 added devices.
12. OTA
The device supports firmware updating through OTA, and will acquire new firmware from zigbee controller or
hub every 10 minutes automatically.
Wiring Diagram
Live
Neutral
PUSH
(1)With Push
push
swi tc h
LL NN
OUT
L
N
A1-A 2: 8-23 0V
AC 100 -2 40V
Rese t PUSH
Live
Neutral
PUSH LV
(2)With Push LV
Power Supply
N L
V- V+
push
switch
LL NN
OUT
L
N
A1-A 2: 8-23 0V
AC 100 -2 40V
Rese t

Other ZIGBEE Switch manuals

ZIGBEE Enbrighten ZB4102 User manual

ZIGBEE

ZIGBEE Enbrighten ZB4102 User manual

ZIGBEE CP-DS112 User manual

ZIGBEE

ZIGBEE CP-DS112 User manual

ZIGBEE ROB 200-035-0 User manual

ZIGBEE

ZIGBEE ROB 200-035-0 User manual

ZIGBEE SR-ZGP2801K4-CCT User manual

ZIGBEE

ZIGBEE SR-ZGP2801K4-CCT User manual

ZIGBEE SZ-ESW01 User manual

ZIGBEE

ZIGBEE SZ-ESW01 User manual

Popular Switch manuals by other brands

Altusen ALTUSEN KH2508 user manual

Altusen

Altusen ALTUSEN KH2508 user manual

Comtrend Corporation ES-7201PoE user manual

Comtrend Corporation

Comtrend Corporation ES-7201PoE user manual

KSR KUEBLER BGU I Series operating instructions

KSR KUEBLER

KSR KUEBLER BGU I Series operating instructions

Belden HIRSCHMANN RSPE 30 user manual

Belden

Belden HIRSCHMANN RSPE 30 user manual

schmersal EX-TV.S 335 operating instructions

schmersal

schmersal EX-TV.S 335 operating instructions

FIBARO FGS-2 3 Series operating manual

FIBARO

FIBARO FGS-2 3 Series operating manual

TRENDnet TE-500 Specifications

TRENDnet

TRENDnet TE-500 Specifications

Moxa Technologies IEX-408E-2VDSL2 series user manual

Moxa Technologies

Moxa Technologies IEX-408E-2VDSL2 series user manual

SMC Networks TigerSwitch SMC8028L2 Specifications

SMC Networks

SMC Networks TigerSwitch SMC8028L2 Specifications

Cisco Catalyst 3560-CX manual

Cisco

Cisco Catalyst 3560-CX manual

H3C S6890 Series OpenFlow Command Reference

H3C

H3C S6890 Series OpenFlow Command Reference

CAMBRIONIX ThunderSync3-16 user manual

CAMBRIONIX

CAMBRIONIX ThunderSync3-16 user manual

Matrix Switch Corporation MSC-2HD3208S product manual

Matrix Switch Corporation

Matrix Switch Corporation MSC-2HD3208S product manual

Pilz PSEN ma1.3b-28 VA operating manual

Pilz

Pilz PSEN ma1.3b-28 VA operating manual

EUCHNER NP Series operating instructions

EUCHNER

EUCHNER NP Series operating instructions

Renkforce RS422 operating instructions

Renkforce

Renkforce RS422 operating instructions

Dell MXL 10GbE reference guide

Dell

Dell MXL 10GbE reference guide

Kontron ETX CD user guide

Kontron

Kontron ETX CD user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.