Introduction
This Quick Start Guide acquaints users with Zilog’s ZMOTION Intrusion Detection
Development Kit (part number ZMOTIONS200ZCOG) and provides instructions for set-
ting up and using the Kit to demonstrate its basic operation. The following topics are cov-
ered:
•Getting Started: the quickest way to get the board up and running; see page 3
•Installing the Lens: see page 5
Kit Contents
• ZMOTION Intrusion Detection Development Board
• USB SmartCable Debugger
• 1.2" focal flat lens holder
• Three 1.2" focal flat lenses
– ZWA12GI12V4
– ZLR12GI12V3
– ZVB12GIV1
• Mini-USB serial cable
• Wall mount power supply
• Mounting hardware
Figure 1 shows the components of the Intrusion Detection Development Kit and Figure 2
displays the three lenses.
ZMOTION®Intrusion
Detection Development Kit
Quick Start Guide QS007802-1014

ZMOTION®Intrusion Detection Development Kit
Quick Start Guide
QS007802-1014 Page 2 of 10
Figure 1. ZMOTION Intrusion Detection Development Kit Components
1.2" Lens Holder

ZMOTION®Intrusion Detection Development Kit
Quick Start Guide
QS007802-1014 Page 3 of 10
Getting Started
The
ZMOTION Intrusion Detection Development Kit
contains several lens options. To
provide a quick method of getting the Kit up and running, the ZMOTION MCU is initially
programmed with a
ZMOTION_Intrusion_Demo
project using the RE200B-P pyroelectric
sensor and the ZWA12GI12V4 lens. By installing the lens and then applying power, the
basic operation of the Kit can be observed.
To get started with the Kit, observe the following brief procedure.
1. Install the ZWA12GI12V4 lens as described on page 5.
2. Insert the power supply output connector into the Mini-USB Plug P1 on the
ZMOTION
Development Board and insert the other end into the wall outlet. Move SW1 on the
board up to the ON position.
Figure 2. The Three Lenses contained in this Development Kit

ZMOTION®Intrusion Detection Development Kit
Quick Start Guide
QS007802-1014 Page 4 of 10
Use the power supply provided with the Kit.
3. The Blue power LED will illuminate and the Red LED will flash 1 second on and one
second off until the pyroelectric sensor stabilizes –a period of approximately 10 to 60
seconds. After the pyroelectric sensor has stabilized, the Red LED turns OFF and turns
ON again only when motion is detected.
4. To test this procedure, wave your hand over the lens and notice the LED turning ON
for approximately 1 second.
To learn more about the operation of the Kit, including how to use the additional features
of the preloaded sample project and how to download and modify other ZMOTION proj-
ects, refer to the ZMOTION Intrusion Detection Kit User Manual (UM0233), available
from the Zilog website.
Downloading ZMOTION Software and Documentation
ZMOTION software and documentation are available as a downloadable file from the
Zilog Store. Observe the following steps to install this software.
1. In a web browser, visit zilog.com/store. At the top left, under Categories, click
Downloadable Software to present a list of the available software in the Zilog Store.
In this list, click ZMOTIONS200ZCOG Software and Documentation; the Product ID
for this software is SD00030.On the Product Details page, click the Add to Cart button
and complete the Checkout process to download the ZMOTION Software and
Documentationfiles toyourhard drive.(Ifyou area first-time visitor to the Zilog Store,
you will be required to register before downloading this software).
2. When the download is complete, unzip the file to your hard drive, double-click to
launch the ZMOTIONS200ZCOG_<version>.exe installation file, and follow the on-
screen instructions.
3. When the installation is complete, the user manual can be viewed in the following path
when using the default installation directory:
C:\Program Files (x86)\ZiLOG\ZMOTIONS200ZCOG_<version>\ZMOTION
Product Documentation
Note:

ZMOTION®Intrusion Detection Development Kit
Quick Start Guide
QS007802-1014 Page 5 of 10
Installing the Lens
When mounting the ZMOTION Development Board vertically, special con-
sideration should be taken regarding the height, angle and level plane of the
board. Be sure to follow the lens manufacturer’s recommended height and
mounting angle requirements to ensure optimal performance.
Flat Lens Holder
The flat lens holder, shown in Figure 3, is a two-piece assembly that provides a 1.2" focal
length mounting. Figure 4 shows the detail of the ZWA12GI12V4 lens, with its correct
orientation.
Figure 3. Flat 1.2"Lens Cap (Top) and Lens Base (Bottom)
Note:

ZMOTION®Intrusion Detection Development Kit
Quick Start Guide
QS007802-1014 Page 6 of 10
To assemble this flat lens and holder, observe the following brief procedure.
1. Place the lens into the inside of the cap, ensuring that the grooves of the lens are facing
inward.
2. Place the cap over the base, ensuring that the top of the lens is toward the arrow on the
base. Use the provided ¾" machine screws (2) with a nut to secure the cap in place, as
shown in Figure 5.
Figure 4. Flat Lens: ZWA12GI12V4

ZMOTION®Intrusion Detection Development Kit
Quick Start Guide
QS007802-1014 Page 7 of 10
3. Place the lens and lens holder assembly onto the ZMOTION Development Board with
the arrow on the lens holder pointing up, as shown in Figure 5; use the Primary Place-
ment position labeled on the circuit board for the ZWA12GI12V4 lens. The four screw
holes in the circuit board should line up with the four upper mounting holes in the lens
holder.
4. Fasten each of the four (4) provided ⅜" machine screws with a nut to secure the lens
holder in place. Figure 6 shows an example of the top of the lens holder installed on the
ZMOTION Development Board.
Figure 5. Assembled Flat 1.2" Lens Holder and Flat Lens

ZMOTION®Intrusion Detection Development Kit
Quick Start Guide
QS007802-1014 Page 8 of 10
Installing ZDSII and the USB SmartCable
To learn more about installing ZDSII and the USB SmartCable, installing the FTDI driver
for the serial cable, downloading and running the sample project, and making changes to
the sample project, refer to the ZMOTION Intrusion Detection User Manual (UM0233),
available on zilog.com.
Figure 6. Top of Lens Holder on the ZMOTION Development Board

ZMOTION®Intrusion Detection Development Kit
Quick Start Guide
QS007802-1014 Page 9 of 10
References
Refer to the documentation in Table 1 for additional information about Zilog’s ZMOTION
products.
Table 1. ZMOTION Documentation
Document
Number Description
PS0288 ZMOTION Intrusion Detection Product Specification
PB0230 ZMOTION Intrusion Detection Product Brief
UM0233 ZMOTION Intrusion Detection Development Kit User Manual
WP0018 ZMOTION Lens and Pyro Configuration Guide
PS0228 Z8 Encore! XP F082A Series Product Specification
PS0286 ZMOTION Lens Product Specification
PS0336 ZMOTION Pyroelectric Sensor Product Specification
RD0001 ZMOTION Intrusion Reference Design
WP0017 ZMOTION –A New PIR Motion Detection Architecture

ZMOTION®Intrusion Detection Development Kit
Quick Start Guide
QS007802-1014 Page 10 of 10
DO NOT USE IN LIFE SUPPORT SYSTEMS.
LIFE SUPPORT POLICY
ZILOG’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPO-
NENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF
ZILOG CORPORATION.
As used herein
Life support devices or systems are devices which (a) are intended for surgical implant
into the body, or (b) support or sustain life and whose failure to perform when properly
used in accordance with instructions for use provided in the labeling can be reasonably
expected to result in a significant injury to the user. A critical component is any compo-
nent in a life support device or system whose failure to perform can be reasonably
expected to cause the failure of the life support device or system or to affect its safety or
effectiveness.
Document Disclaimer
©2014 Zilog, Inc. All rights reserved. Information in this publication concerning the
devices, applications, or technology described is intended to suggest possible uses and
may be superseded. ZILOG, INC. DOES NOT ASSUME LIABILITY FOR OR PRO-
VIDE A REPRESENTATION OF ACCURACY OF THE INFORMATION, DEVICES,
OR TECHNOLOGY DESCRIBED IN THIS DOCUMENT. ZILOG ALSO DOES NOT
ASSUME LIABILITY FOR INTELLECTUAL PROPERTY INFRINGEMENT
RELATED IN ANY MANNER TO USE OF INFORMATION, DEVICES, OR TECH-
NOLOGY DESCRIBED HEREIN OR OTHERWISE. The information contained within
this document has been verified according to the general principles of electrical and
mechanical engineering.
ZMOTION is a registered trademark of Zilog, Inc. All other product or service names are
the property of their respective owners.
Warning:
Other manuals for ZMOTION
1
This manual suits for next models
1
Table of contents
Other ZiLOG Security Sensor manuals