10Bar 400D User manual

1
CameraHousing Model400D(Canon)
UserManual
Contents:
1.Introduction
2.Specifications
3.SetupInstructions
4.Function Controls
5.Use&CareofHousing
6.Service
7.Warranty
1.Introduction
10BARUnderwaterHousingsare small,lightandruggedenoughtobeusedoneverydive.Useofclear
polycarbonate allowsfor visualinspectionofcameraconditionand theO-ringseal.10BARHousingsare
designedfor theever-increasingvarietyofmodelsofdigitalstillandvideocameras.Advancedcomputeraided
designandCNCmanufacturingtechnologiesensureprecisedimensions.Eachhousingbodyisfirstinjection
molded,and thenmachinedtoconfiguretoindividualcameramodel.Arangeoflensportsandcontrolsare
fitted,totailorthe housingtoyourcameramodel.
2.Specifications400D
TestPressure 10 Bar(300ft.)Housingsareindividuallytested
ClosureDesign AirLock
BodyMaterial Polycarbonate
OverallSize 200x300x230mm(LxWxH)
TotalWeight Approximately2.6Kg(Housingonly)
Buoyancy(withcamera) Approximatelyneutralinsalt water
Features VisiblemainO-ringfor finalpre-divecheck
DoubleO-ringdesignonall controls
Bulkheadandhot shoeplugfor External580-EXe-TTLstrobe
StandardZoomPort18~55mm Lens
Accessories 400DOpeningkey /Lever
SiliconeO-ringgrease
SparemainO-ring
Carryingbag
CleaningKit
Optionalaccessories Semi-DomePortfor10~22mm Lens
580-EXe-TTLFlashlightHousing
FlexArm
Ball-JointArm
SynchronousCord

2
3.FunctionControls400D
1.Pressurerelease plug
2.Displayon/off
3.Menu
4.Jump
5.Playback
6.Erase
7.Viewfinder eyepiece
8.A/ECompensation
9.DriveMode
10.AE/FELock
11.AF PointSelection
12.13.14.15.CrossKey
16.Setting
17.Shutter
18.MainDial
19.ModeDail/Power on/off
20.Flashlightsynbulkhead
21.Zoomcontroldial
4.SetupInstructions
4.1 AirLock:
Thebodyandlidaredesigned withtheAirLockSystem noclip closurearrangement.Testinghas
shownthatthisarrangementallowthewatertoexertanevenpressureontheO-ring,Increasethereliabilityof
the watertightseal.

3
4.2 Pressurereleaseplug
Toopenthehousing,thepressure
releaseplugmustbefirstunscrewedand
then pulledoutalltheway
(Counter-clockwise) (Fig1).This
providesapassagefortheairtopass
thoughand eliminatethepressure
differentbetweentheinsideofthe
housingandtheambient.Theplug
consistsofaninternaldoubleO-ringseal
onthestainlesssteelslideshaft.
TheseinternalO-ringsformthe
watertightseal.There isalsoalarge
outerO-ringunder theknob.ThisO-ring
servestopreventcontaminationofthe
slideshaft,withdirt,saltetc.,andisnot
requiredforwatertightintegrity.Ifthis
O-ringshouldbecomedetached,itcan
simplybepushedbackinplace.
4.3 Openinglevers:
Afterunscrewingandpulling outthepressurereleaseplug,thelidcanbeopened.Toovercomethe
frictionofopening,uselever (Fig.2)topushagainstthelidwithacamaction.Besuretheyare insertedallthe
wayflattothehousingbeforeturningtoavoiddamagingtheprotrusionsonthelid.Thebodyhasfourholeson
eachcorneredgesforopening.Gentlylever offthelidwiththe suppliedopeninglever(Fig.3) takingcarenot
totwistthelidexcessively.Thelidshouldbeopenedkeeping itapproximatelyparalleledtothebodyatall
times,turnfirstonecorneralittle,thentheother alittle,andrepeatagainuntil thelidisopened.Remember to
unscrewandpulloutthepressurerelease plugallthe wayfirst,otherwisetheair pressure will resistattempts
atopening.Laythelid onaflatstablesurfaceafteropening.
4.4 Specialnoteon responsibilityforwatertightintegrity:
Each housingisindividuallyinspectedandhydrostaticallytested inthefactory.Thedesignofthe
mainpistonO-ringsealisamongthemostreliableintheindustryandthewatertightintegrityisexcellent.This
specialO-ringdesignprovidesaperfectsealevenifthereisanymovementbetweenthebodyandlid dueto
change ofambientpressure.Howeverpleasenotethatresponsibilityforensuring theintegrityofthe
watertightsealliesentirelywiththeuser.10BARacceptsnoliabilityfordamageto,orlossofanyequipment
usedwith,orplacedinsidethe housing.Usersare highlyrecommended tocarryoutin-watertestofthe

4
housingswithoutinstallingofthecamerafortheirfirstdiveafter changeofnewportsoralternationofanynew
configuration.The testcanbecarriedoutbyloweringthehousingwithballasttothe workingdepthor dive
downtothesafediving range.
The O-ringsealisthemainbarrierbetweenthe wateroutsideandtheairspacewithinthe
camera. Itis aneffectivebarrieronlyifthesealisproperlymaintained.TheO-ringsealshouldbe
inspectedbeforeeverydive.Thefollowinginformation isprovidedyou¡reyourguidanceinusing
andmaintainingtheO-ringseal.
4.5 Maintainingthe O-ringSeal:
IfthemainbodytolidO-ringisnotinstalled,installtheO-ring beforediving.Thisistheonlyuser
serviceableO-ring.Itscareandmaintenanceiscriticaltothewatertightintegrityofthehousing.TheO-ring
shouldbereplacedattheserviceinterval(seesectiononservice).IftheO-ringiscontaminated,ornotalready
installed,inspectgrease andinstalltheO-ringaccordingtothefollowing guidelines.
4.6 Inspection,cleaningandre-instillationofthe O-ring
Tools:
Asoftcottonbudor spongeapplicator,makesure theseare freeofallchemicalsorcontamination
such asloosefibers, andthetubeofsilicone grease suppliedwiththe housing.Noteothertypesofsilicone
greasespecificallyfor usewithunderwater cameraequipmentcanusuallyalsobeused.Itisadvisedtocarry
outthefollowingprocedure onafirmcleanlevelsurface,(e.g.atatable),topreventskiddingespeciallyuseful
tohavewhendivingfromaboat.
When tomaintaintheO-ringseal:
RemovetheO-ringperiodicallyforinspection.Itisnotnecessarytoremove,cleanand
re-install theO-ringaftereverydiveprovidedtheO-ringdidnotbecomecontaminated.Asaruleofthumbset
upthecameraand housing beforeaday sdiving.Ifthehousingisrequiredtobeopenedbetweendivesfor
changing memorycardorre-chargingbatteries,makesuretheoutsideofthehousingisthoroughlytoweled
drybeforeopeningup.After removing thelidandservicingthecamera,replace the lid straightaway,rather
thanleaving itlyingaround.Before replacingthelid,makesurethatnocontaminationsuch asdust,hair,salt,
sand etc.hasfallenontotheO-ringorO-ringrecess,asaprecautionwe recommendtoinspecttheO-ring
everytimethelidisopenedandtocarryoutthemaintenanceifnecessary.
Procedure:
Place the lidonafirmnon-slip levelsurface.
TheO-ring canbe extractedusinganO-ringextractor tool(make sure
the toolasnosharpedges).Alternativelyusethe flatsofthethumbsto
gentlystretchtheO-ringontwofaces(Fig.4)thusmaking asmall loop
protrudingafew mm.Theloopcanthenbegraspedbetweenfinger and
thumb,topulltheO-ringover thelip.
CleantheO-ringrecess(thesquaregroovewheretheO-ringsits)with
acottonbud.
InspecttheO-ring allthewayrounditssurfacefordamagesuchascutstearsorcontamination.Thisshould
bedonevisuallyandalsobyfeelingthesurfacetexturebetweenfingerandthumb.
IFTHEO-RINGISDAMAGEDORSUSPECTED OF BEINGDAMAGED,DISCARDITIMMEDIATELY.
A spareO-ringissuppliedwithyourhousing,orareplacementO-ringcanbeobtainedfrom10 BAR.Ifthe
O-ringiscontaminatedor suspectedofbeingcontaminated,cleanitwithacottoncloththatisfreeofall
chemicalsorcontamination.After cleaninginspecttheO-ringagain.
OncetheO-ringhasbeeninspectedandverifiedfitforuse,applya SMALL amountofSiliconegreasetothe
O-ring.ThesiliconegreasemustbeevenlydistributedroundtheO-ring
Replace theO-ringintothegroove;run afingerroundtheO-ring,tomakesure itissnuglyseatedinthe

5
groove.
4.7 Mountingthe camerainthehousing:
Removethelenscapandwriststrap.Thepressurereleaseplugshouldbepulledoutbefore inserting
thecamera.Attachtheplasticslidetraytothecamera stripodmountingfixturewithacoin,screwdriveror the
endoftheuniversaltoolsupplied(Fig.5).Takecarenottoexcessivelytightenthescrew.Slidethecamerainto
the bodyalong theguide rail (Fig.6).Makesure thecamerabodyreachthelimitand testthe functionofthe
on/ofbuttononthebodyofthehousing.Slidethehotshoeplugintothehotshoe(Fig.7)Note:Ifyoufindthat
the buttonsdonotalignproperlywiththe controls,pleasecheckagainthatthe cameraisproperlyseatedto
the limitoftheguiderail.
Replacethelid(Fig.8).Remember
toensurethepressure releaseplug
ispulledallthewayoutwhile
closing,otherwisetheaircannot
escape.Squeeze thelidclosedall
thewaywiththehissingofexpelled
air.Screwhome (CLOCKWISE)
the pressurereleaseplug (Fig.9).
There isnoneed toexcessively
tightenthisplug.Thesealismade
byinternalO-rings. TheO-ringontheundersideoftheplugisjusttokeepoutdirt.
Afterreplacingthelid,makeafinalvisualinspectionofthe main
O-ringforcontamination(Fig.10).
Note: IftheO-ringis ingoodcontact,athinblackline,
about0.5to1mminwidthshouldbevisible,wherethe
O-ringisincontactwiththelid.Follow thislineallthe
way roundtheedgeoftheseal,asafinalcheckthatthe
sealisgood.Thehousingis nowreadyforthe dive.
Important!!! Beforediving,makesurethepressure
releaseplugispushedbackinsideandthenscrewed
home,donotovertightenthisplug(fingertightonly).

6
5.Use&CareofHousing:
5.1 PreDiveFunction Check.
Justbeforeenteringthewater,makeahabitofreviewingthatyouhavecarriedoutthe
properstepstoclosethehousing.and the pressure releaseplug screwedhome.Make a
visualcheckoftheO-ringseal.Itisalsousefultoswitchonthecamera,andcheckthat
controlse.g.on/off,zoom,shutterfunctionsoperatenormally.
Checkhousingisclosed.
Closepressurereleaseplug
Checkbatteryandmemory cardstatus ontheLCDdisplay.
Checkcontrolknobandzoomfunction.
Ifthereis alargechangeoftemperatureandthehousingis notopenedformaintenance
betweendives,itis recommendedtoequalizethepossiblepressuredifferencebetweenthe
insideofthehousingandtheambientbyopeningthepressurereleaseplugandcloseitfirmly
subsequently.Alwaysavoidsubmergingthehousinginhotwater foraprolongedtime ora
cleansingtank wherethewatermaybeheatedupbythesun.
5.2 GeneralOperation.
ThecontrolleversandpushbuttonsconsistofinternaldoubleO-ring sealsonastainless steelshaft.
Thisarrangementisveryreliable,however asaprecaution,whenoperating the controls,avoid excessively
rapidmovements, asthismaydistorttheO-ring.Alsoplease allow forthefactthatthecameratakesafew
secondstopoweron.Ifthecameradosenotappear torespondtoacontrolaction,makesure thatnoother
controlsarepressingonthecamera,i.e.lockingoutfurther actions.Wearthewriststrap;itiseasyto
inadvertentlyletgoofthe housing,especiallyifyouaredistracted.
5.3 Cleaning&Storage.
Thebody&lidofthe housingaremadeofpolycarbonate.Polycarbonatewasselectedforits
outstandingstrengthstiffness, hardness andtoughness.Aswellasitscrystalcleartransparencyandhighgloss
surface.Ithasgoodresistance toweathering,althoughlongtermexposure tosunlightshould beavoided.
Normaloperatingtemperaturerange is3 Cto36 C(Storagetemperature:-10 Cto50 C)Itisgoodpractice
torinseoffyour housingwithfreshwater aftereverydive.Avoidexposuretofinesand.Afteraseriesof10or
moredives, e.g.afteradiveholiday,itisrecommendedtoimmersethehousingfor2-3hoursinwarmwaterto
dissolveanysaltdepositsthat mayhavebuiltup.Nochemicalcleanersshouldbe used.Milddetergentse.g.
shampooandsoap based cleanersare permitted.
Somehouseholdchemicals may harmPolycarbonate; the
housingshouldneverbeexposedtothefollowingclassesofchemicals:
benzene,toluene,xylene,chlorinatedhydrocarbons,methanol,anyothersolvents,
strongacidsandbases.Forlongtermstoragepleaseremovethemaino-ringfrombody.
5.4 Transportation.
Whentransportingbyair,pleaseensure thehousingisnotsealed,toallow theairpressureto
equalize.EitherremovetheO-ring(recommended),oropenthepressurereleaseport(aspacerisprovidedto
keep thepressureplugintheopenposition,please makesurethereisnobendingofthe plugwhile open).
Pleaseprotectthehousingduringtransportation.Itisrecommendedtoremovethehandle,and shutter
extension,andwrapthecamerainfoamorbubblewrap.
5.5 Accidents.
Theimpactresistanceofthe housingisexcellent.However after anaccidentthealignmentofthe
housingmayhavebeendamaged.Therefore intheeventofyourhousingsufferinganimpactforce,e.g.being

7
dropped,itisessentialyoudonotusethehousingfordiving.Pleasereturnthehousingimmediatelyforservice.
Pleaseputanoteinsidetoindicatethenature oftheaccident,so thattheseveritycanbeassessed.
6.Service
Toensure thecontinued performance ofyourhousing,itshouldbe servicedeveryyear,orafter
every200dives.Please notethe termsfor servicing thehousing posted at ourwebsite.A fullservice will
include:
Inspectionofallcomponentsforwearsordamage(reportifrepairnecessary)
Cleaningofallsealingsurfaces,andreplacementofallO-ringseals.
Hydrostaticpressure testto10Bar.
Note:thereplacementofdamagedcomponents(exceptreplacementO-rings)mayrequire
additionalcost.
7.Warranty
Thewarrantyis validwithintwoyearsfromthe dateoffirstpurchase.Thewarranty
appliesonlytothehousingitself.10 BARdoesnotacceptanyliabilityeitherimplicitorotherwise
foranyequipmenthousedinside,orusedtogetherwiththehousing.Intheeventofthehousing
floodingwithintheperiodofwarranty,10 BARwillrepairor replacethehousing.Pleasenote
thatdisassemblyofthehousingwill invalidatewarranty. Pleasefillintheinformationbelow,and
returnacopyto10BarUnderwaterHousingattheaddress below,tovalidatethewarranty.
HousingType:
DateofPurchase:
SerialNumber: (Labeledinsidehousing)
Dealer:
Owner¡sName:
e-mail:
Address:
Tel:
Fax:
Office&Showroom:
UnitC,2/F.,WingHinFactoryBuilding,31-33NgFongSt.,
SanPoKong,HongKong.
Tel:(852)25733228 Fax:(852)28119180.
Email: service@10bar.com Website:http//www.10bar.com
Pleasekeepthisdocumentforfuturereference
(Note: dueto continuousimprovementthelatestmodel housingmaydifferslightlyformthosedescribedinthisdocument)
(Copyto bereturned to10 BarUnderwaterHousings)
Table of contents
Other 10Bar Camera Accessories manuals

10Bar
10Bar 10BAR 450D User manual

10Bar
10Bar E-500 User manual

10Bar
10Bar LUMIX LX3 User manual

10Bar
10Bar GF1 User manual

10Bar
10Bar FL 50 - Hot-shoe clip-on Flash User manual

10Bar
10Bar Underwater Housing User manual

10Bar
10Bar EOS XTi EOS400D User manual

10Bar
10Bar D80 User manual

10Bar
10Bar G10 User manual

10Bar
10Bar Underwater Housing User manual