2N Netstar User manual

www.2n.czVersion
2N
®NetStar
Communication System
Hardware manual
4.3.x

The 2N TELEKOMUNIKACE a.s. is a Czech manufacturer and supplier of telecommunications
equipment.
The product family developed by 2N TELEKOMUNIKACE a.s. includes GSM gateways, private
branch exchanges (PBX), and door and lift communicators. 2N TELEKOMUNIKACE a.s. has
been ranked among the Czech top companies for years and represented a symbol of
stability and prosperity on the telecommunications market for almost two decades. At
present, we export our products into over 120 countries worldwide and have exclusive
distributors on all continents.
2N is a registered trademark of 2N TELEKOMUNIKACE a.s. Any product and/or other
®
names mentioned herein are registered trademarks and/or trademarks or brands protected
by law.
2N TELEKOMUNIKACE a.s. administers the FAQ database to help you quickly find
information and to answer your questions about 2N products and services. On
www.faq.2n.cz you can find information regarding products adjustment and instructions for
optimum use and procedures „What to do if...“.
2N TELEKOMUNIKACE a.s. hereby declares that the 2N product complies with all
®NetStar
basic requirements and other relevant provisions of the 1999/5/EC directive. For the full
wording of the Declaration of Conformity see the CD-ROM (if enclosed) or our website at
www.2n.cz.
The 2N TELEKOMUNIKACE a.s. is the holder of the ISO 9001:2009 certificate. All
development, production and distribution processes of the company are managed by this
standard and guarantee a high quality, technical level and professional aspect of all our
products.
Content

Content
1. System Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.1SelectoftheInstallationpart .......................................6
1.2UnwrappingandControl ...........................................7
1.3Installation .....................................................8
1.4TermsandSymbols ..............................................11
2. Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.1BasicModule ...................................................13
2.2ExtensionModule ................................................16
2.3PositionandPortNumbering .......................................17
2.4CPUCard ......................................................18
2.5CPUCard-Extensionmodule ......................................21
2.6SWITCHcard ...................................................22
2.7PRICard .......................................................26
2.8BRICard .......................................................29
2.9DVLCard ......................................................32
2.10DIGITALCOMBOCard ..........................................34
2.114ASL/4AVLCard ...............................................36
2.12AVLCard .....................................................38
2.13GSMCard .....................................................40
2.14UMTScard ....................................................41
2.15AudioCard_IO_Relay ............................................42
2.16IPCard .......................................................46
3. Power source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
3.1PowerSupplyConnection .........................................48
3.2SystemGrouping ................................................49
3.3Powersupplybackup .............................................51
4. Technical parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

42N TELEKOMUNIKACE a.s., www.2n.cz
®
1. System Installation
Here is what you can find in this section:
1.1 Select of the Installation part
1.2 Unwrapping and Control
1.3 Installation
1.4 Terms and Symbols
Selection of the Installation Site
The following aspects shall be taken into consideration while selecting a site for the
system installation:
Good accessibility:
All interfaces for the connection of the telecommunication interfaces or data network
connections, as well as the switch-on, switch-off and system reset controls are placed
on the front side.
Installation of infrastructure in the building:
The system was designed for installation in a 19" rack and connection to the structured
wiring infrastructure with termination at a CAT 3 or CAT 5 patch panel. If the
infrastructure is already ready the switchboard installation site is usually given and can
not be further changes. The interface must however be adjusted for the connection via
RJ 45 8/8 plugs.
Protection against humidity and extreme temperatures:
The appliance may never be placed close to heat sources (radiators) or
places exposed to direct sunshine. Also places with high humidity (such as
bathrooms and cellars), places with significant temperature fluctuation
(next to doors, windows, air-conditioning), dusty places (workshops, etc.)
or places exposed to aggressive gases (accumulator room, boiler room) as
well as places with intensive vibrations and places exposed to shocks
(compressor rooms, heavy industrial operations) should be avoided. The
system should be installed horizontally.

52N TELEKOMUNIKACE a.s., www.2n.cz
®
GSM signal quality:
If a GSM card is a part of your system (or will become later on), it is necessary to
consider that the cable leading from the GSM card to the GSM antenna is usually 3m
long (max. 10m). You should ensure that within this diameter from the selected
system installation site a place with good GSM signal suitable for placement of the GSM
antenna is available. *)
Theft protection:
While selecting the installation site the insurance company conditions should be
regarded as well.
Caution
In the areas with very poor GSM signal level or high number of GSM gates
the use of internal (takes the position of a line card) or external GSM
splitter is advantageous.

62N TELEKOMUNIKACE a.s., www.2n.cz
®
1.1 Select of the Installation part
The following aspects shall be taken into consideration while selecting a site for the
system installation:
Good accessibility – All interfaces for the connection of the telecommunication
interfaces or data network connections, as well as the switch-on, switch-off and
system reset controls are placed on the front side.
Protection against humidity and extreme temperatures – The appliance
may never be placed close to heat sources (radiators) or places exposed to direct
sunshine. Also places with high humidity (such as bathrooms and cellars), places
with significant temperature fluctuation (next to doors, windows,
air-conditioning), dusty places (workshops, etc.) or places exposed to aggressive
gases (accumulator room, boiler room) as well as places with intensive vibrations
and places exposed to shocks (compressor rooms, heavy industrial operations)
should be avoided. The system should be installed horizontally.
Installation of infrastructure in the building – The system was designed for
installation in a 19" rack and connection to the structured wiring infrastructure
with termination at a CAT 3 or CAT 5 patch panel. If the infrastructure is already
ready the switchboard installation site is usually given and can not be further
changes. The interface must however be adjusted for the connection via RJ 45
8/8 plugs.
GSM signal quality – If a GSM card is a part of your system (or will become
later on), it is necessary to consider that the cable leading from the GSM card to
the GSM antenna is usually 3m long (max. 10m). You should ensure that within
this diameter from the selected system installation site a place with good GSM
signal suitable for placement of the GSM antenna is available. *)
Theft protection – While selecting the installation site the insurance company
conditions should be regarded as well.
Note
In the areas with very poor GSM signal level or high number of GSM gates
the use of internal (takes the position of a line card) or external GSM
splitter is advantageous.

72N TELEKOMUNIKACE a.s., www.2n.cz
®
1.2 Unwrapping and Control
The wrapping of the basic or extension module is usually used also for the
transportation of other, separately acquired system components (antennas and other
small additional equipment). These can be checked by matching the items on the
supply list and the ordering numbers stated on all components. Usually, the system is
delivered as tailor made according to the submitted order. The installation set,
electronic documentation on a CD and warranty certificate are a part of the delivery.
The remaining components such as telephone units and other terminals or additional
appliances are delivered separately.
Caution
If you have not already done so, please check the completeness of the
delivery.

82N TELEKOMUNIKACE a.s., www.2n.cz
®
1.3 Installation
Here is what you can find in this section:
System Connection
System Installation

92N TELEKOMUNIKACE a.s., www.2n.cz
®
System Connection
The system is installed into a deep. The height of each module isRACK min. 400 mm
3U - 132 mm.
The system was not designed to be equipped with an active cooling unit, however the
producer recommends in order to achieve a better air ventilation in case of bigger
installations (more modules above each other) to leave a gap of e.g. 1U between the
separate modules. For this purpose an organizer, which at the same time will ensure a
better manipulation with the wiring, can be used.
For a shelf installation the system is equipped with 4 stands that create a gap between
the shelf and the module body to ensure sufficient system ventilation.

102N TELEKOMUNIKACE a.s., www.2n.cz
®
System Installation
The same applies for the connection to the 230 V or 115 V power supply Network,
which is subject to the local and national regulations and directives.
The connection of the system to the telecommunication network is subject to local
national regulations and directives. The interface of the line cards terminates in a RJ45
plug.
Only appliances complying with the basic requirements and further specifications of the
directive no. 1999/5/ES (Government Directive No. 426/200 Coll., which stipulates the
technical requirements of radio and telecommunication terminal appliances, in the
wording of the later regulations) may be connected to the internal analogue interface.
The supplied wiring including an additional connection to the single ground point is
used for connection. If you do not use the additional system grounding, the over
voltage protection integrated in the line cards will not work.
The communication system was designed as digital appliance (TDM circle2N Netstar
®
switching) with sufficiently powerful processor and LAN connection with integrated VoIP
telephony.

112N TELEKOMUNIKACE a.s., www.2n.cz
®
1.4 Terms and Symbols
Manual Symbols
The following symbols and pictograms are used in the manual:
Future Functions, Innovations
The in this document designates the functions that are undergrey-marked text
preparation or development at present.
Safety
abide by this information to prevent persons from injury.Always
Warning
abide by this information to prevent damage to the device.Always
Caution
Important information for system functionality.
Tip
Useful information for quick and efficient functionality.
Note
Routines or advice for efficient use of the device.

122N TELEKOMUNIKACE a.s., www.2n.cz
®
2. Technical specifications
Here is what you can find in this section:
2.1 Basic Module
2.2 Extension Module
2.3 Position and Port Numbering
2.4 CPU Card
2.5 CPU Card - Extension module
2.6 SWITCH card
2.7 PRI Card
2.8 BRI Card
2.9 DVL Card
2.10 DIGITAL COMBO Card
2.11 4ASL/4AVL Card
2.12 AVL Card
2.13 GSM Card
2.14 UMTS card
2.15 Audio Card_IO_Relay
2.16 IP Card

132N TELEKOMUNIKACE a.s., www.2n.cz
®
2.1 Basic Module
Here is what you can find in this section:
Basic Module
Basic Module Pro

142N TELEKOMUNIKACE a.s., www.2n.cz
®
Basic Module
The Basic Module Lite represents a business alternative of the basic module
equipped with an CPU card, Switch X card that does not enable the connection of
extension modules and one AVL card.
Ord. no. 101034 2N NETSTAR BASIC rack
basic module 8x AVL
Ord. no. 101014 2N NETSTAR BASIC
module 8x ASL

152N TELEKOMUNIKACE a.s., www.2n.cz
®
Basic Module Pro
Basic Module Profi is a business alternative of the basic module equipped with a CPU
card, Switch card that enables the connection of up to 4 extension modules.
Ord. no. 101031 2N NETSTAR PRO rack
basic module (empty)
Ord. no. 101011 2N NETSTAR PRO basic
module (empty)

162N TELEKOMUNIKACE a.s., www.2n.cz
®
2.2 Extension Module
The extension module is equipped with an 8-bit CPU, which controls up to 11
analogue line cards. The following cards are supported: AVL, ASL, GSM and
AUDIORELE.
Ord. no. 101036 2N NETSTAR PRO rack
extender analogue only
Ord. no. 101016 2N NETSTAR PRO
extender analogue only

172N TELEKOMUNIKACE a.s., www.2n.cz
®
2.3 Position and Port Numbering
Each card and port is assigned a specific unique HW address.
The address consists of 4 parts and is stated in the form: R : C : B : P, whereas
the separate letters stand for the following:
R – rack
Rack represents the entire system appliance consisting of the basic module
and four extension modules (case), in the current version only one Rack is
supported. The rack address is thus 0.
C – case
Covers the basic or one of the four extension modules.
The address of the basic module is 1, the extension modules are assigned
addresses from 2 to 5 according to their SWITCH card Connections.
B – board
The separate cards (board) are assigned addresses from left to the right,
both in the basic as well as the extension modules. The address of the first
position in the module is 1 and is reserved for maincase CPU or for
extender CPU.
Compared to the extension module, in which the cards are assigned
addresses from 1 to 12, the assigning of addresses in the basic module is
governed by predefined rules.
The basic module uses following rules for the card positions and assigning of
addresses.
Address 1
Reserved for controlling CPU only (position 1)
the card address is 0:1:1
Addresses 2,3,4
Reserved for the PRI and VoIP cards (positions 2,3 and 4)
the cards addresses are 0:1:2, 0:1:3 and 0:1:4
Address 5
Reserved for the SWITCH card (position 5)
the card address is 0:1:5
Addresses 6,7,8,9,10,11,12,13 and 14
The addresses correspond to the positions 6,7,8,9,10,11,12,13 and 14 and
can be used for any line card. An exception are the positions with the
addresses 6, 9 and 12, in which if you use a BRI or DIGITAL COMBO card
the first 2 ports on the card are always NT and may not be changed.
P – port
The card ports are assigned the addresses from left to the right and from
top to the bottom.
The addresses start with 1.
For the purpose of better orientation the PRI, GSM and Audio/IO/Relay
cards have the serial numbers of the ports printed on their front side.

182N TELEKOMUNIKACE a.s., www.2n.cz
®
2.4 CPU Card
The card is an inseparable part of the basic module.
It contains all necessary interfaces needed for the communication with the
system.
It is only installed in the basic module, always in the position with the 0 HW
address.
LAN

192N TELEKOMUNIKACE a.s., www.2n.cz
®
Interface type – Eth T–Base 10/100
Connection – RJ45
Pin1= transit +,
Pin2= transit -,
Pin3= receive +,
Pin6= receive -
USB
USB Host interface Connection
Interface type – USB 1.1
Connection – 2x USB–A
Physical layer – Low Speed – 1.5Mbits/s
Power supply – 5V
Consumption – max. 100mA
COM
RS 232C interface connection
Interface type – RS232C
Configuration – 115200Bd, 8bit, parity: none, stop bit: 1
Connection – RJ11 (6x6)
Pin1= TxD-,
Pin2= TxD+,
Pin3,4= GND,
Pin5= RxD+,
Pin6= RxD-
MMC
MMC cards slot – MMC 7pins
MMC 4.0 and MMC Plus 13 pins
Buses – 1–bit (MMC) and 4–bit (MMC4.0 and MMC+)
Power supply – 3,3V
Reading speed – up to 22, Mb/s
Writing speed – up to 18 Mb/s
Maximum recommended capacity – 4 GB

202N TELEKOMUNIKACE a.s., www.2n.cz
®
RES
The Reset button will reboot the
entire system.
Maintenance switch
ON position – appliance switched on
OFF position – appliance switched off, the position is equipped with a 3s
by-pass for the switching into the Maintenance Mode
Maint. position – appliance in the maintenance mode, the line cards supply
switched off and the card drivers stopped in order to enable their maintenance or
exchange, or changes in the port set-up.
After the switching into the ON position, the card drivers are launched and their power
supply is switched on – no need for the re-launching of the entire system and starting
of all processes.
Other manuals for Netstar
5
Table of contents
Other 2N Telephone manuals