SPECIFICATIONSperformance level for access controlThis product complies with the following UL294 Access Control Performance Levels:Destructive AttackLevel 1Line SecurityLevel 1EnduranceLevel 4ProxLevel 1BluetoothStandby PowerLevel 1See the UL Listed access control unit controller installation instructions for reader compatibility.environmentalOperating Temperature-31°F to + 151°F (-35°C to +66°C)Humidity86 ±3°F (85 ±5% at 30 ±2°C)Ingress ProtectionIP65 (not evaluated by UL)PositioningSuitable for OUTDOOR use.electricalPower supplyPower is to be provided by a UL294 Listed,low-voltage Class 2 power limited supply orcontrol panel, capable of 4 hours standby.Voltage+10Vdc to +16VdcCurrentData VoltageRest >4Vdc / Active <1VdcData OutputWiegand, Clock & Data, Custom OutputsIndication1 RGB LED(+ RGB LED illuminated keypad to 3MIL-R11325)SounderIntegral speaker3M S-Gang Keypad3M S-Gang3M Mullion3M Inline62mA41mA41mA15mA3MIL-R113253MIL-R113203MIL-R113303MIL-R11030Average100mA 82mA 82mA 35mA PeakIdle and Peak current at 12VdcModelPart No.dimensionspolymeric materialsPotting compoundUL R/C (QMFZ2)MouldingsUL746CwiringWiring methods shall be in accordance withthe National Electrical Code (ANSI/NFPA70),local codes, and the authorities having jurisdiction.Recommended cableBELDEN 953x (or equivalent UL listed) for Wiegand.BELDEN 9502 (or equivalent UL listed) for RS485.All cable and wiring must be Listed and suitable for use. Cable lengthUp to 492 feet (150 m) from controller.Minimumrecommended wire sizeNot less than 24 AWG.reader connectionsThese connections are common to all readers inthe BD series. 1-0VSupply voltage ground 2-+VdcSupply voltage (+10Vdc to +16Vdc) 3-DATA1/CLKWiegand or Clock/Data output 4-DATA0/DATWiegand or Clock/Data output 5-GREENGreen LED control input 6-REDRed LED control input 7-BuzzerBuzzer control input 8-TMPR/CPTamper or Card Present output 9-RS485-RS485 Bus10-RS485+RS485 Bus3M S-Gang Keypad3M S-Gang3M Mullion3M Inline4.7 x 3.0 x 0.8 in ( 120 x 76 x 21 mm )4.7 x 3.0 x 0.8 in ( 120 x 76 x 21 mm )3.8 x 2.1 x 0.8 in ( 96 x 52 x 21 mm )3.8 x 2.1 x 0.8 in ( 96 x 52 x 21 mm )3MIL-R113253MIL-R113203MIL-R113303MIL-R11030ModelSize - Inches ( millimetres )Part No.100-02643-A-DEV023millID - 3M Inline3MIL-R11030•125kHz•Supra®BT LE (2.4GHz)3millID - 3M S-Gang3MIL-R11320•125kHz•13.56MHz•Supra®BT LE (2.4GHz)3millID - 3M S-Gang Keypad3MIL-R11325•125kHz•13.56MHz•Supra®BT LE (2.4GHz)3millID - 3M Mullion3MIL-R11330•125kHz•13.56MHz•Supra®BT LE (2.4GHz)3millID.com +1 303 475 4972Specifications subject to change without notice.©2017 3millID. All rights reserved.100-02654-CPlease turn over for installation guidance notes
i
Mounting this reader on (or near) metal may impair the read range of the unit.INSTALLATION GUIDEBluetooth is a registered trademark of Bluetooth SIG•Supra®BT LE
100-02643-A-DEV02 1-0VSupply voltage ground 2-+VdcSupply voltage (+10Vdc to +16Vdc) 3-DATA1/CLKWiegand or Clock/Data output 4-DATA0/DATWiegand or Clock/Data output 5-GREENGreen LED control input 6-REDRed LED control input 7-BuzzerBuzzer control input 8-TMPR/CPTamper or Card Present output 9-RS485-RS485 Bus10-RS485+RS485 BusIf fitted, remove reader module securing screw.Pull bottom edge of reader module away from the backplate, and lift up.Mount the reader backplate to a flat surface using suitable hardware having a diameter no greater than 0.15 in (4mm).Once the backplate has been mounted, make wire connections to the reader module in accordance with the screw terminal connections shown below, and your control panel requirements. Ensure the cable does not impair or prevent the reader module being secured.Position the reader module, ensuring the top-edge fixing lugs engage correctly with the recesses located at the top of the backplate. Swing the bottom edge of the module down and forward until you feel the unit click shut.Secure the reader module to the backplate using the M3x100mm screw as supplied.1423567If required, you may opt to use security screw.4bApplicable to 3M Inline add-on reader only. The following is a diagrammatic representation of the wiring configuration providing a Bluetooth capabaility to most existing installations. Please consult your installer and the manufacturer’s details of your existing control panel and access control reader.( THIS CONFIGURATION NOT EVALUATED BY UL )line INline OUTpin10V2+Vdc (+12Vdc)3N/A4N/A5N/A6N/A7N/A8N/A9RS485 -10RS485 +line INline OUT0V+Vdc (+12Vdc)N/AN/AN/AN/AN/AN/ARS485 -RS485 +existingACCESSCONTROLREADER
line out from 3M Inline reader
securityaccessCONTROLPANEL
3M Inline reader
line in from control panel
1 2 3 4 5 6 7 8 910
compliantRoHSThese devices comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.These devices contains: FCC ID: TCZ-10103751G1EQUIPMENTBP210182AKUW-AV002AKUW-AV90These RFID proximity readers comply with the essential requirements and relevant provisions of:EU Directive 2014/53/ECTogether with information provided by suppliers and subcontractors, these devices comply with the requirements and relevant provisions of:EU Directive 2011/65/EC.This symbol on the product or on its packaging indicates that the product must not be disposed of with normal household waste. Instead, it is your responsibility to dispose of your waste equipment by arranging to return it to a designated collection point for the recycling of waste electrical and electronic equipment. By separating and recycling your waste equipment at the time of disposal you will help to conserve natural resources and ensure that the equipment is recycled in a manner that protects human health and the environment.EU Directive 2012/19/EUThese notes are provided as a general guidance for mounting, fixing and connecting 3millID - 3M series RFID readers. Please consult your installer and the manufacturer’s details of your control panel, when configuring your access security system.GENERAL GUIDANCE NOTES to APPLIES TO ALL READER MODELS LISTED OVERLEAF17

This manual suits for next models

3

Popular IP Access Controllers manuals by other brands

Soyal AR-888-PBI-S manual

Soyal

Soyal AR-888-PBI-S manual

IP-COM CW1000 user guide

IP-COM

IP-COM CW1000 user guide

HEART HA 5035 user manual

HEART

HEART HA 5035 user manual

BioTrack BioExterior installation guide

BioTrack

BioTrack BioExterior installation guide

Linear AP-5 Installation instructions manual

Linear

Linear AP-5 Installation instructions manual

Moniteq Crypto-Lock CC-8521B instruction manual

Moniteq

Moniteq Crypto-Lock CC-8521B instruction manual

bioscrypt VeriProx Operation manual

bioscrypt

bioscrypt VeriProx Operation manual

Mottura X Mode 99.690 manual

Mottura

Mottura X Mode 99.690 manual

ACTi R71CF-34 user manual

ACTi

ACTi R71CF-34 user manual

Control iD iDFace quick guide

Control iD

Control iD iDFace quick guide

Tidomat SO-3396-V installation instructions

Tidomat

Tidomat SO-3396-V installation instructions

Retekess T-AC03 user manual

Retekess

Retekess T-AC03 user manual

Zap ACC200 quick start guide

Zap

Zap ACC200 quick start guide

Soyal AR-331-EF manual

Soyal

Soyal AR-331-EF manual

eKey Home operating instructions

eKey

eKey Home operating instructions

SDC 950 ENTRYCHECK Installation & programming instructions

SDC

SDC 950 ENTRYCHECK Installation & programming instructions

BKT Elektronik ACBS Installation and configuration manual

BKT Elektronik

BKT Elektronik ACBS Installation and configuration manual

Spica Door Cloud Zone spot Quick connection guide

Spica

Spica Door Cloud Zone spot Quick connection guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.