
TRX MAINSOutputAssignment
AdvanceOutputMapping(requires IRRemote-10)
The Default AssignedOutput forthe TRXMAINS is 8,tochangethis pleasefollowthe steps below:
1– Safely applypowertothe TRXMAINS
2- Pointthe IRremoteatthe bottomofthe TRXMAINS andpress Pfollowedbythe Output youwishto
Mapitto(1-8)then E.The TRXMAINS shouldgiveatriplebeepindicatingthis wassuccessful.
Note.It is not recommendedtoMaptoOutput1or 2asthey arefor Sirensbydefault.
3- Makeanoteofthisnumberhereandonthe TRXMAINS.
Note.MultipleTRXMAINScan bepairedtothe same Output.
*Withan Output Assignedintothe TRXMAINS it’sTriggerInput isnotDirectly linkedtothe SwitchedOutput.
If youwishthe TriggerInput toactivatethe SwitchedOutputyoumustprogram itintothe EliteSPanel.
=
ProgrammingTriggerInputto SwitchedOutputLink withESL ControlBoard
The ESLv908.12chaspreassignedslotsfor the TRXMainsdevices.
If youhavean Elite-S or Elite-S-LiteControl boardv908.12bor olderpleaseuseprogrammingonpage8
Followthe listbelowfor the Addressesthat relatetothe TRXMainsOutput numberassigned:
*Programmingbelowisdone fromthe Control PanelKeypadinInstallerMode.
Default =8
Page7
= 31– LearnState1(ON) tothe first Userslot
P18 E90EE (when beepingstartsflickthe switch connectedtothe TRXMainsOn)
2– LearnState2(OFF)tothe secondUserslot. ifyouhaveamomentaryswitch,skipthis step
P18 E91EE (when beepingstartsflick the switch connectedtothe TRXMainsOff)
3– AdjustingOutput Reset Time,the default reset time isonly2seconds.
P40 E3E0E (lightsnowwill notautomaticallyturnoff)
= 51– LearnState1(ON) tothe first Userslot
P18 E92EE (when beepingstartsflickthe switch connectedtothe TRXMainsOn)
2– LearnState2(OFF)tothe secondUserslot. ifyouhaveamomentaryswitch,skipthis step
P18 E93EE (when beepingstartsflick the switch connectedtothe TRXMainsOff)
3– AdjustingOutput Reset Time,the default reset time isonly2seconds.
P40 E5E0E (lightsnowwill notautomaticallyturnoff)
= 61– LearnState1(ON) tothe first Userslot
P18 E94EE (when beepingstartsflickthe switch connectedtothe TRXMainsOn)
2– LearnState2(OFF)tothe secondUserslot. ifyouhaveamomentaryswitch,skipthis step
P18 E95EE (when beepingstartsflick the switch connectedtothe TRXMainsOff)
3– AdjustingOutput Reset Time,the default reset time isonly2seconds.
P40 E6E0E (lightsnowwill notautomaticallyturnoff)
= 71– LearnState1(ON) tothe first Userslot
P18 E96EE (when beepingstartsflickthe switch connectedtothe TRXMainsOn)
2– LearnState2(OFF)tothe secondUserslot. ifyouhaveamomentaryswitch,skipthis step
P18 E97EE (when beepingstartsflick the switch connectedtothe TRXMainsOff)
3– AdjustingOutput Reset Time,the default reset time isonly2seconds.
P40 E7E0E (lightsnowwill notautomaticallyturnoff)
= 81– LearnState1(ON) tothe first Userslot
P18 E98EE (when beepingstartsflickthe switch connectedtothe TRXMainsOn)
2– LearnState2(OFF)tothe secondUserslot. ifyouhaveamomentaryswitch,skipthis step
P18 E99EE (when beepingstartsflick the switch connectedtothe TRXMainsOff)
3– AdjustingOutput Reset Time,the default reset time isonly2seconds.
P40 E8E0E (lightsnowwill notautomaticallyturnoff)