AAP TRX Mains Instruction manual

Phase Out
Neutral Out
Phase In
Neutral In
Switch
230VAC
10A
TRXMAINS
TRXMAINS CONNECTIONDIAGRAM
Specifications:
Operating Voltage: 220-240VAC 50Hz
Current Draw: 5mA
Max. Switching Current: 8AResistiveLoad, 6AInductiveLoad.
Frequency: 917.1- 921.3MHz
Connection:
1=NeutralIn
2=Phase TriggerInput
3=Phase In
4=Switched Phase Output, 8Amp Max.
Manufactured byArrowhead Alarm Productsltd.
344b Rosedalerd, Albany, Auckland, New Zealand
Ph.09-414-0085www.aap.co.nz
LOAD
8AMAX.
Page1

TRXMAINS
In Wall Installation
Page2
FLUSH
BOX

TRXMAINS
Optional
Trigger
Input
PlasticEnclosureInstallation
Use ElectricallyApproved Plastic EnclosureOnly
*Do Not MountTRX-MAINS inaMetalEnclosure.
SuitableEnclosures:
TB-AG-1010 (100x100mm)
TB-AG-1115 (110x150mm)
Page3

High CurrentContactorWiring
*Onlyuse Contactorswith230VAC Coil
and Contactsto suit switched load.
Phase In
Neutral In
TRXMAINS
Phase Out
230VAC 230VAC
Page4
Mounted insideplastic enclose
TB-AG-1115 (110x150mm)
Warning: TheTRXMainsrelayisnot suitableformounting inaccessiblelocations.
It must beinstalledwithinanenclosureproviding suitableinsulation, asshownabove.
Optional
Override
Input

Page5
Phase Out
NeutralOut
Phase In
Neutral In
Switch1
TRXMAINS
LOAD
8AMAX.
Switch2
2-WayLightSwitching Example
ExistingWiredSolution

TRX MAINSProgrammingStep1
Option1 Pairingto TransceiverusingMagnet
1– Safely applypowertothe TRXMAINS
2– Present &hold the Magnet nexttothe TRXMAINS (see diagram a).
The TRXMAINS will startbeepingasit searchesfor adevice topairwith.
3- Nowputthe TRXTRANSCEIVER(connectedtothe ELITES) intopairingmode,bypressingandhold-
ingthe redbuttonfor 2seconds (see diagram b).The blue pairingLEDshould startflashing.
4- The BeepingfromTRXMAINS should then stop, indicatingpairingis complete.The blue LEDonthe
TRXTRANSCEIVERwill stop flashingafter60 seconds, orpress the redbuttontomakeit stop.
Option2 Pairingto TransceiverusingIRRemote-10
1– Safely applypowertothe TRXMAINS
2- Pointthe IRremoteatthe bottomofthe TRXMAINS (see diagram c)andpress Pthen E.The
TRXMAINS will startbeepingasit searchesfor adevice topair with.
3- Nowputthe TRXTRANSCEIVER(connectedtothe ELITES) intopairingmode,bypressingandhold-
ingthe redbuttonfor 2seconds (see diagram b).The blue pairingLEDshould startflashing.
4- The BeepingfromTRXMAINS should then stop, indicatingpairingis complete.The blue LEDonthe
TRXTRANSCEIVERwill stop flashingafter60 seconds, orpress the redbuttontomakeit stop.
Page6
MAGNET
-MAGNETALIGNMENT-
diagram a Pairing Button
diagram b
diagram c QRCODELINK
TOIR-REMOTE

TRX MAINSOutputAssignment
AdvanceOutputMapping(requires IRRemote-10)
The Default AssignedOutput forthe TRXMAINS is 8,tochangethis pleasefollowthe steps below:
1– Safely applypowertothe TRXMAINS
2- Pointthe IRremoteatthe bottomofthe TRXMAINS andpress Pfollowedbythe Output youwishto
Mapitto(1-8)then E.The TRXMAINS shouldgiveatriplebeepindicatingthis wassuccessful.
Note.It is not recommendedtoMaptoOutput1or 2asthey arefor Sirensbydefault.
3- Makeanoteofthisnumberhereandonthe TRXMAINS.
Note.MultipleTRXMAINScan bepairedtothe same Output.
*Withan Output Assignedintothe TRXMAINS it’sTriggerInput isnotDirectly linkedtothe SwitchedOutput.
If youwishthe TriggerInput toactivatethe SwitchedOutputyoumustprogram itintothe EliteSPanel.
=
ProgrammingTriggerInputto SwitchedOutputLink withESL ControlBoard
The ESLv908.12chaspreassignedslotsfor the TRXMainsdevices.
If youhavean Elite-S or Elite-S-LiteControl boardv908.12bor olderpleaseuseprogrammingonpage8
Followthe listbelowfor the Addressesthat relatetothe TRXMainsOutput numberassigned:
*Programmingbelowisdone fromthe Control PanelKeypadinInstallerMode.
Default =8
Page7
= 31– LearnState1(ON) tothe first Userslot
P18 E90EE (when beepingstartsflickthe switch connectedtothe TRXMainsOn)
2– LearnState2(OFF)tothe secondUserslot. ifyouhaveamomentaryswitch,skipthis step
P18 E91EE (when beepingstartsflick the switch connectedtothe TRXMainsOff)
3– AdjustingOutput Reset Time,the default reset time isonly2seconds.
P40 E3E0E (lightsnowwill notautomaticallyturnoff)
= 51– LearnState1(ON) tothe first Userslot
P18 E92EE (when beepingstartsflickthe switch connectedtothe TRXMainsOn)
2– LearnState2(OFF)tothe secondUserslot. ifyouhaveamomentaryswitch,skipthis step
P18 E93EE (when beepingstartsflick the switch connectedtothe TRXMainsOff)
3– AdjustingOutput Reset Time,the default reset time isonly2seconds.
P40 E5E0E (lightsnowwill notautomaticallyturnoff)
= 61– LearnState1(ON) tothe first Userslot
P18 E94EE (when beepingstartsflickthe switch connectedtothe TRXMainsOn)
2– LearnState2(OFF)tothe secondUserslot. ifyouhaveamomentaryswitch,skipthis step
P18 E95EE (when beepingstartsflick the switch connectedtothe TRXMainsOff)
3– AdjustingOutput Reset Time,the default reset time isonly2seconds.
P40 E6E0E (lightsnowwill notautomaticallyturnoff)
= 71– LearnState1(ON) tothe first Userslot
P18 E96EE (when beepingstartsflickthe switch connectedtothe TRXMainsOn)
2– LearnState2(OFF)tothe secondUserslot. ifyouhaveamomentaryswitch,skipthis step
P18 E97EE (when beepingstartsflick the switch connectedtothe TRXMainsOff)
3– AdjustingOutput Reset Time,the default reset time isonly2seconds.
P40 E7E0E (lightsnowwill notautomaticallyturnoff)
= 81– LearnState1(ON) tothe first Userslot
P18 E98EE (when beepingstartsflickthe switch connectedtothe TRXMainsOn)
2– LearnState2(OFF)tothe secondUserslot. ifyouhaveamomentaryswitch,skipthis step
P18 E99EE (when beepingstartsflick the switch connectedtothe TRXMainsOff)
3– AdjustingOutput Reset Time,the default reset time isonly2seconds.
P40 E8E0E (lightsnowwill notautomaticallyturnoff)

=
Page8
=
=
=
Ub=
Ub=
=
=
Ua=
Ua=
=
Ub=
=
Ua=
Ub=
Ua=
Ub=
Ua=
AssigningInputControl withElite-S& Elite-S-LitePCB
Choose2SpareUserSlotsfrom21 to100andput them inwhereyousee theseboxes
Don’t Dothis programmingifyouhavean ESL-PCBv908.12c(usepage7instead)
*Programmingbelowisdone fromthe Control PanelKeypadinInstallerMode.
1– LearnState1tothe first Userslot
P18 EE (when beepingstartsflick the switch connectedtothe TRXMainsOn)
2– LearnState2tothe secondUserslot. ifyouhaveamomentary switch,skipthis stepand8to11
P18 EE (when beepingstartsflick the switch connectedtothe TRXMainsOff)
3– Set the UserAssignment State1(by defaultall userslotsArmandDisarm,this needs tobechanged)
P4EE turnOff all options E
4– OutputMappingfor State1
P12 EEE
5– OutputOnCommand for State1
P13 EEE
6– OutputOff Commandfor State1
P14 EEE
7– OutputPermission
P34 EE turnOnoption 6E
8– OutputReset Time
P40 EE turnOnoption 6E
9– Set the UserAssignment
P4EE turnOff all options E
10– OutputMappingfor State2
P12 EEE
11– OutputOnCommandfor State2
P13 EEE
12– OutputOff Commandfor State2
P14 EEE
Ua=
Ub=
RangeTest
Once youhavelearnt theTriggerInput intothe panel, arangetest isrecommended
*Programmingbelowisdone fromthe Control PanelKeypadinInstallerMode.
P200E14EE nowActivatethe TriggerInput
The UserSlot it hasbeen loadedintowillflashupandapercentage.100%=full signalstrength.
Note.Repeatthe processfor each TRXMAINS device,
If less than 30%considerrelocatingthe TRXTransceivertogetbettersignalstrength.

GroupModeProgramming
If GroupModehasbeen selected, the TRXMAINS will turnOnwhen Output 7fromthe panelturnsOn
andwill turnOff when Output 8fromthe panelturnsOn.
This allowmultipleTRXMAINS modulesall settoGroupModetoturnoff andontogetherfromapanel
request,such as:Arming/Disarmingthe alarm,Fire/Burglaralarmactivation,Timercontrol.
In GroupModethe TriggerInput is alwaysdirectly linkedtothe SwitchedOutput.Achangeinstateof
the TriggerInput willchangethe SwitchedOutput state,regardless ofwhat positionthe switch isin.
SelectingGroupMode
TosetaTRXMAINS toGroupModeyoumust usethe IR-Remote-10
1– Safely applypowertothe TRXMAINS
2- Pointthe IRremoteatthe bottomofthe TRXMAINS (see diagram c)andpress P, 0 then E.
The TRXMAINS will giveatriplebeepifaccepted.
ProgrammingOptions
*Programmingbelowisdone fromthe Control PanelKeypadinInstallerMode.
Lights Off whenSystemis Armed
P47 E1E (turn 8On) E
Lights OnwhenSystemis Disarmed
P49 E1E (turn 7On) E
Lights OnwhenFireAlarm Activates
P130E(zone No. ofsmokedetector 1-16) E (turn 7On) E (must bedone for each 24-hourFirezone)
Lights OnwhenBurglarAlarmActivates
P128E(zone No. ofdetector 1-16)E (turn 7On) E (mustbedone foreach zone/detector)
Lights OnwhenStay BurglarAlarmActivates
P129E(zone No. ofdetector 1-16)E (turn 7On) E (mustbedone foreach zone/detector)
Page9

Heated TowelRail Wiring
Phase In
Neutral In
TRXMAINS
Optional
Override
Input
Earth In
To Heated
TowelRail
8AMax.
Mounted insideplastic enclose
TB-AG-1010 (100x100mm)
Warning: TheTRXMainsrelayisnot suitableformounting inaccessiblelocations.
It must beinstalledwithinanenclosureproviding suitableinsulation, asshownabove.
Page10

=
=
=
1– Set OnTime 1.
P172E1E (enterstarttime is 24hrformat 0000-2359) E
2- Set Off Time 1. noteOff time mustbeafterOntime.
P173E1E (enterfinishtime is 24hrformat 0000-2359) E
3- Set Timer1DaysofWeek.
P171E1E (put indayactivedays1-7,see table) E
4- AssignTimer1toan Output.
P44 E (enteroutput number)E1 E
5– ChangingResetTimerofOutput.
P40 EE0 E
NeedanotherOnandOffsequence?Followthe steps below.
6– Set OnTime 2.
P172E2E (enterstarttime is 24hrformat 0000-2359) E
7- Set Off Time 2. noteOff time mustbeafterOntime.
P173E2E (enterfinishtime is 24hrformat 0000-2359) E
8- Set Timer2DaysofWeek.
P171E2E (put indayactivedays1-7,see table) E
9- AssignTimer2toan Output.
P44 E (enteroutput number)E2 E
No.Day
1=Sunday
2=Monday
3=Tuesday
4=Wednesday
5=Thursday
6=Friday
7=Saturday
Page11
AutomaticOn/Offtimer(RecommendedforHeated Towel Rail)
Thereare8different On/Off timers that can beset inthe Elite-S seriescontrol panel.
Beforestartingthe Programmingsteps belowmakesurethe TRXMainshasbeen pairedtothe TRX
Transceiver(see page6)andan Output numberhasbeen assigned(see page7).
*Programmingbelowisdone fromthe Control PanelKeypadinInstallerMode.
SmartFeatures
AutomaticTurnLights Off whenSystemArms
Each Output(TRXMAINS) can beSelectedtoturnOff when the AlarmSystem is Armed.
*Programmingbelowisdone fromthe Control PanelKeypadinInstallerMode.
P54 E1E E (each TRXMainsnumbercan beturnedonhere)
Note.Don’t turnon1or2this will triggerthe sirens
=
AdjustingLightsOn ExitTimer
Once youhaveturnedOnthe optionabove,youcan choosetoextendtheOff delaytime upto25 sec-
onds. This will giveyouanilluminatedexit fromthepropertybeforeturningthe lightsOff.
Each Output(TRXMAINS) can beadjustedindividually.
*Programmingbelowisdone fromthe Control PanelKeypadinInstallerMode.
P39 EE time in10ths/second 1-255E (250 =25seconds)
Note.Repeatthe processfor each TRXMAINS youwishtohavethis feature
=
FallbackFeature
If communicationis lost tothe TRXTransceiver, the TRXMainswillautomatically Fallback andoperating
directly fromit’sTriggerInput.

ARROWHEAD ALARM PRODUCTSLtd.
344bRosedaleRd,
Albany,
Auckland.
Ph.09414 0085
Fax. 09 4140088
www.aap.co.nz
v1.01
Page12
Warning! Thisunit containsno userserviceableparts, it must bereturned to the
manufactureifit failsto operateorthecableisdamaged.
Install onlyaspermanufactures instructionsand/orinrecommended enclosure.