ABB CL Series Instructions for use

—
APPLICATION MANUAL
Display system
CL range

I
Before commencing the installation
• Disconnect the power supply of the device.
• Ensure that devices cannot be accidentally
restarted.
• Verify isolation from the supply.
• Earth and short circuit.
• Cover or enclose neighbouring units that
are live.
• Follow the operating and installation
instructions of the device concerned.
• Only suitably qualified personnel in
accordance with EN 50110-1/-2
(VDE 0105 Part 100) may work on this
device/system.
• Before installation and before touching
the device ensure that you are free of
electrostatic charge.
• The functional earth (FE) must be
connected to the protective earth (PE) or
to the potential equalisation. The system
installer is responsible for implementing
this connection.
• Connecting cables and signal lines should
be installed in such a way that inductive or
capacitive interference does not impair the
automation functions.
• Install automation devices and related
operating elements in such a way that they
are well protected against unintentional
operation.
• Suitable safety hardware and software
measures should be implemented for the
I/O interface so that a line or wire breakage
on the signal side does not result in
undefined states in the automation
devices.
• Ensure a reliable electrical isolation of the
low voltage for the 24 volt supply. Only
use power supply units complying with
IEC 60364-4-41 (VDE 0100 Part 410) or
HD 384.4.41 S2.
• Deviations of the mains voltage from the
rated value must not exceed the tolerance
limits given in the specifications, otherwise
this may cause malfunction and dangerous
operation.
•Emergencystopdevices complying with
IEC/EN 60204-1 must be effective in all
operating modes of the automation
devices. Unlatching the emergency-stop
devices must not cause restart.
• Devices that are designed for mounting in
housings or control cabinets must only be
operated and controlled after they have
been installed with the housing closed.
Desktop or portable units must only be
operated and controlled in enclosed
housings.
Safety instructions
Warning!
Dangerous electrical voltage!
SI1_G.FM Seite I Mittwoch, 7. März 2007 9:49 09

II
• Measures should be taken to ensure the
proper restart of programs interrupted
after a voltage dip or failure. This should
not cause dangerous operating states even
for a short time. If necessary, emergency-
stop devices should be implemented.
• Wherever faults in the automation system
may cause damage to persons or property,
external measures must be implemented to
ensure a safe operating state in the event
of a fault or malfunction (for example, by
means of separate limit switches,
mechanical interlocks etc.).
SI1_G.FM Seite II Mittwoch, 7. März 2007 9:49 09

1
1SVC 440 795 M1100
About this manual 9
Device designation 9
Reading conventions 9
1 Display system 11
Intended users 11
Proper use 11
– Improper use 11
Overview 12
Device overview 14
– Display system devices at a glance 14
Operating the display system 16
– Keypad 16
– Selecting menus and entering values 16
– Selecting main and system menu 18
– Status display display system 18
– Status display for local expansion 19
– Advanced status display 19
– Display system LED display 19
–Menustructure 21
– Selecting or toggling between menu items 27
– Cursor display 28
– Setting values 28
2 Installation 29
Mounting 29
Connecting the expansion device 46
Terminals 46
– Tool for cage clamp terminals 46
– Connection cross-sections of the cage clamp
terminal cables for the display system 46
– Tool for the screw terminals of the CL
expansion 46
– Connection cross-sections of screw terminal
cables of the CL expansions 46
Network cables and plugs 47
Table of Contents

Table of Contents
2
1SVC 440 795 M1100
Connecting the power supply 47
– Cable protection 50
Connecting inputs 51
– Connecting AC display I/O modules 51
– Connecting DC display I/O modules 56
Connecting outputs 61
Connecting relay outputs 62
– CL-LDR… 62
– CL-LER.18AC2, CL-LER.20DC2 63
– CL-LER.2O 63
Connecting transistor outputs 64
– CL-LDT… 64
– CL-LET.20DC2 64
Connecting the analog output 66
– Connecting servo valves 67
– Setpoint entry for a drive 67
Connecting the CL-NET network 68
– Accessories 68
– Cable length with cross-sections 69
– Plugging and unplugging network cables 71
Connecting the serial interface 73
Expanding inputs/outputs 76
– Local expansion 77
– Remote expansion 78
3 Commissioning 79
Switching on 79
Setting the menu language 79
Display system operating modes 80
Creating your first circuit diagram 81
– Starting point: Status display 83
– Circuit diagram display 84
– From the first contact to the output coil 85
– Wiring 86
– Testing the circuit diagram 88
– Deleting the circuit diagram 91
– Fast circuit diagram entry 91

Table of Contents
3
1SVC 440 795 M1100
Configuring a CL-NET network 92
– Entering the network station number 93
– Entering network stations 94
– Configuring a CL-NET network 95
– Changing the CL-NET network configuration 96
– Displaying the status display of other stations 97
Configuring the interface for the COM-LINK mode 98
– Setting up the COM-LINK 99
Terminal mode operation 103
– Terminal mode 103
4 Wiring with the display system 113
Display system operation 113
– Buttons for editing circuit diagrams and
function relays 113
– Operation 114
– Usable relays and function blocks (coils) 122
– Markers, analog operands 125
– Number formats 128
– Circuit diagram display 128
– Saving and loading programs 130
Working with contacts and relays 131
– Creating and modifying connections 134
– Inserting and deleting a rung 136
– Saving circuit diagrams 137
– Aborting circuit diagram entry 137
– Searching for contacts and coils 137
– “Go to” a rung 138
– Deleting a rung 138
– Switching with the cursor buttons 138
– Checking the circuit diagram 140
– Function block editor 141
– Checking function blocks 144
– Coil functions 146

Table of Contents
4
1SVC 440 795 M1100
Function blocks 150
– Analog value comparator/threshold value
switch 152
– Arithmetic function block 155
– Data block comparator 159
– Data block transfer 166
– Boolean operation 177
– Counter 180
– High-speed counters 186
– Frequency counter 187
– High-speed counters 191
– High-speed incremental encoder counter 196
– Comparators 201
– Data function block 203
– PID controller 205
– Signal smoothing filter 211
– GET, fetch a value from the network 214
– Seven-day time switch 215
– Year time switch 220
– Value scaling 224
– Jumps 228
– Master reset 231
– Numerical converter 232
– Operating hours counter 237
– PUT, send a value onto the network 239
– Pulse width modulation 240
– Setting date/time 244
– Set cycle time 245
– Timing relay 247
– Value limitation 260
– Example with timing relay and counter function
block 262

Table of Contents
5
1SVC 440 795 M1100
5 Visualization with the display system 267
Screens 267
– Memory layout 268
– Western European character table 269
Screen overview 271
Screen editor 273
– Static text 273
– Bit display 276
– Date and time 280
– Bitmap 283
– Numerical value 289
– Example program – Numerical value: 290
– Value entry 299
– Message text 305
Button editor 317
– Select operable screen element 317
– Display backlight 317
– Screen change 317
– Password logout 318
– Set variable to fixed value 318
– Increment variable 318
– Decrement variable 318
– Changeover relay 318
6 CL-NET network, COM-LINK serial
connection 319
Introduction to CL-NET 319
CL-NET network topologies, addressing and
functions 320
– Loop through the unit wiring method 320
– T connector and spur line. 320
– Position and addressing of the operands via
CL-NET 322
– Possible write and read authorisation in the
network 324

Table of Contents
6
1SVC 440 795 M1100
Configuration of the CL-NET network 325
– Station number 325
– Transmission speed 325
– Pause time, changing the write repetition rate
manually 326
– Automatic change of the RUN and STOP
mode 327
– Configuring an input/output device (REMOTE
IO) 328
– Station message types 329
– Transfer behaviour 330
– Signs of life of the individual stations and
diagnostics 331
Introduction to COM-LINK 334
– Configuration of the COM-LINK 338
7 Display system settings 343
Password protection 343
– Password setup 344
– Selecting the scope of the password 345
– Activating the password 346
– Unlocking the display system 347
Changing the menu language 350
Changing parameters 351
– Adjustable parameters for function blocks 352
Setting date and time 353
Changing between winter/summer time (DST) 354
– Manual selection 355
Activating input delay (debounce) 356
– Deactivating debounce (input delay) 356
Activating and deactivating the P buttons 357
– Activating the P buttons 357
– Deactivating the P buttons 357

Table of Contents
7
1SVC 440 795 M1100
Startup behaviour 358
– Setting the startup behaviour 358
– Behaviour when the circuit diagram is deleted 359
– Behaviour during upload/download to memory
module or PC 359
– Possible faults 359
– Startup behaviour for memory module 360
– Terminal mode 361
Setting LCD contrast and backlight 362
Retention 363
– Requirements 364
– Setting retentive behaviour 365
– Deleting ranges 366
– Deleting retentive actual values of markers and
function blocks 366
– Transferring retentive behaviour 366
Displaying device information 367
8 Inside the display system 369
Display system program cycle 369
– How the display system evaluates the
high-speed counters CF, CH and CI 373
– Display system memory management 373
Delay times for inputs and outputs 374
– Delay times for the display system inputs 375
Monitoring of short-circuit/overload with CL-LST,
CL-LMT and CL-LET 376
Expanding the display system 378
– How is an expansion unit recognised? 378
– Transfer behaviour 379
– Function monitoring of expansion units 379
Analog output QA 380
Loading and saving programs 380
– Display system without display and keypad 381
– Interface 381
– Memory module 382
– CL-SOFT 385
Device version 388

Table of Contents
8
1SVC 440 795 M1100
Appendix 389
Technical data 389
– General 389
– Display base module, real-time clock/timing
relay/memory 398
– Transistor outputs 404
– Analog output 407
– CL-NET network 408
List of function blocks 409
– Function blocks 409
– Function block coils 410
– Function block outputs (operands) 413
– Other operands 413
Memory requirement 413
Index 415

9
1SVC 440 795 M1100
About this manual
This manual describes the installation, commissioning and
programming (circuit diagram generation) of the display
system.
Specialist electrical training is needed for commissioning and
creating circuit diagrams. When controlling active
components such as motors or pressure cylinders, parts of
the system can be damaged and persons put at risk if the
display system is connected or programmed incorrectly.
Device designation This manual uses the following abbreviated designations for
different device models:
• Display system
• CL-AC2 for CL-LER.18AC2
• CL-DC2 for CL-LER.18DC2, CL-LET.20DC2
Reading conventions Symbols used in this manual have the following meanings:
XIndicates actions to be taken.
hAttention!
Warns of the risk of material damage.
iCaution!
Warns of the possibility of serious damage and slight
injury.
jWarning!
Indicates the risk of major damage to property, or serious
or fatal injury.
hDraws your attention to interesting tips and
supplementary information.

About this manual
10
1SVC 440 795 M1100
For greater clarity, the name of the current chapter is shown
in the header of the left-hand page and the name of the
current section in the header of the right-hand page. This
does not apply to pages at the start of a chapter and empty
pages at the end of a chapter.

11
1SVC 440 795 M1100
1 Display system
Intended users The display system must only be installed and connected up
by trained electricians or other persons who are familiar with
the installation of electrical equipment.
Specialist electrical training is needed for commissioning and
creating circuit diagrams. When active components such as
motors or pressure cylinders are controlled, parts of the
system can be damaged and persons put at risk if the display
system is connected or programmed incorrectly.
Proper use The display system is a programmable HMI, switching
closed-loop and open-loop control device for replacing relay
and contactor controls as well as for use as an HMI unit. The
display system must be properly installed before use.
The display module of the display system is protected to
IP 65 and does not normally need any special housing
protection. The rear units of the display system are designed
as mounting units and must be installed in an enclosure,
control cabinet or a service distribution board. Both the
power feed and the signal terminals must be laid and
covered so as to prevent accidental contact.
The installation must comply with regulations for
electromagnetic compatibility (EMC).
The power up of the display system must not cause any
hazards arising from activated devices, such as unexpected
motor startups or power ups.
Improper use
The display system should not be used as a substitute for
safety-related controls such as burner or crane controls,
emergency-stop or two-hand safety controls.

Display system
12
1SVC 440 795 M1100
Overview The display system is an electronic display and operating
device as well as a logic relay with the following:
• Logic frunctions,
• Timing relay and counter functions,
• Time switch functions,
• Arithmetic functions,
• PID controllers,
• Operator and display functions.
The display system is a control and input device rolled into
one. The display system allows you to implement many
different tasks in domestic applications as well as in machine
building and plant construction. The display system is a
modular and flexible device.
The integrated CL-NET network allows up to eight CL-NET
stations to be connected to a controller. Each CL-NET station
can contain a program. In this way, high speed control
systems with remote intelligence can be created.
In Terminal mode, the display system can be used to control
any device in the network and display data from it. The
display system makes its keypad and display available to the
other device for use.
Two display systems can be connected simply via the serial
interfaces.
Circuit diagrams are connected up using ladder diagrams,
and each element is entered directly via the display system
display. For example, you can:
• Connect N/O and N/C contacts in series and in parallel
• Connect output relays and markers,
• Define outputs as coils, impulse relays, rising or falling
edge-triggered relays or as latching relays,
• Select timing relays with different functions:
–On-delayed
– On-delayed with random switching,
–Off-delayed,

Overview
13
1SVC 440 795 M1100
– Off-delayed with random switching,
– On- and off-delayed,
– On- and off-delayed with random switching,
– Single pulse,
– Synchronous flashing,
– Asynchronous flashing.
• Use up and down counters,
• Count high-speed signals:
– Up/down counters with upper and lower limit value,
– Preset,
– Frequency counters,
– High-speed counters,
– Count incremental encoder values.
•Comparevalues,
• Display graphics, texts, variables, enter setpoints, display
flashing values and graphics, change and replace graphics
and texts by pushbutton,
• Process analog inputs and outputs,
• Use 7-day and year time switches,
• Count operating hours (operating hours counter),
• Communicate via the integrated CL-NET network,
• Set up point-to-point communication via the serial
interface,
• Implement closed-loop control with P, PI and PID
controllers,
• Scale arithmetic values,
• Output manipulated variables as pulse-width modulated
signals,
• Run arithmetic functions:
–Add,
–Subtract,
–Multiply,
– Divide.
• Track the flow of current in the circuit diagram
• Load, save and password-protect circuit diagrams

Display system
14
1SVC 440 795 M1100
If you prefer to wire up the display system from a PC, then
use the CL-SOFT programming tool. This software is used to
create and test your circuit diagram on the PC. All display
and operator functions on the display system device are
created exclusively using CL-SOFT. CL-SOFT enables you to
print out your circuit diagram in DIN, ANSI or CL format.
Device overview Display system devices at a glance
Display module
Figure: 1: Display module device overview
aDEL button
bGraphic display
cALT button
dLEDs for signalling
eMode button
fRight, down cursor buttons
gOK button
hLeft, up cursor buttons
iESC button
a
d
b
iefg
h
c

Device overview
15
1SVC 440 795 M1100
Display base module
Figure: 2: Device overview of display base module
aSupply voltage
bCL-NET terminals
cCL-LINK terminal
dInterface for memory module, PC and point-to-point connection
ePower supply/operating mode LED
fCL-NET LED
Display I/O module
Figure: 3: Device overview of display I/O module
aInputs
bAnalog output (optional)
cOutputs
ab
c
e
f
d
b
a
c

Display system
16
1SVC 440 795 M1100
Operating the display
system
Keypad
Selecting menus and entering values
DEL: Delete object in circuit diagram
ALT: Special functions in circuit diagram, status display
Cursor buttons úíÍÚ:
Move cursor
Select menu items
Set numbers and values
OK: Next menu level, Save your entry
ESC: Previous menu level, Cancel
*:
Toggle between visualization display and status display
Close Terminal mode
hIn visualization applications, the keypad of the operating
unit can be used for other functions than the ones stated
above. In this case the buttons are assigned the function
selected in the application. The standard button functions
are only restored when you leave the application.
*
DEL ALT
ESC
OK
and Show system menu
Move to next menu level
Call menu item
Activate, change, store entries
Move to previous menu level
Cancel entries since last OK
DEL ALT
OK
ESC

Operating the display system
17
1SVC 440 795 M1100
Í Ú
ú í Change menu item
Change value
Change digit
P button function:
ú
í
í
Input P1
Input P3
Í
ÚInput P2
Input P4
and Reset the display system display
DEL ESC
Other manuals for CL Series
1
This manual suits for next models
2
Table of contents
Other ABB Monitor manuals

ABB
ABB 9438 User manual

ABB
ABB 8232 User manual

ABB
ABB Endura AZ25 Series User manual

ABB
ABB IRC5 Compact User guide

ABB
ABB 7835 User manual

ABB
ABB M2238 Series User manual

ABB
ABB TMC User manual

ABB
ABB CEM11-FBP.35 User manual

ABB
ABB Industrial enabled Analyzer 9437 User manual

ABB
ABB Endura AZ20 series Operating manual