abbexa abx725008 User manual

Product Manual
Abbexa Ltd., Cambridge Science Park, Cambridge, CB4 0EY, UK
www.abbexa.com · Email: inf[email protected] · Phone: +44 (0) 1223 755950 · Fax: +44 (0) 1223 755951
Registered in England: 8475531 · VAT Reg. No: GB 167 9240 79
1
abx725008
Mini Vortex Mixer
Table of Contents
1Preface.............................................................................................................. 2
1.1 Introduction........................................................................................................ 2
1.2 Features............................................................................................................. 2
2Installing the device......................................................................................... 3
2.1 Standard accessories ........................................................................................ 3
2.2 Standard parts................................................................................................... 3
2.3 Unpacking the device......................................................................................... 3
3Operating the device ....................................................................................... 4
3.1 Start and stop operation..................................................................................... 4
4System maintenance and troubleshooting.................................................... 4
4.1 Safety precautions............................................................................................. 4
4.2 Instrument disinfection....................................................................................... 4
4.3 Routine maintenance......................................................................................... 5
4.4 Troubleshooting................................................................................................. 5
5Specification parameters................................................................................ 6
6Product disposal.............................................................................................. 6
7Warranty statement ......................................................................................... 7
Revision date: 15-Aug-17
For Reference Only

Product Manual
Abbexa Ltd., Cambridge Science Park, Cambridge, CB4 0EY, UK
www.abbexa.com · Email: inf[email protected] · Phone: +44 (0) 1223 755950 · Fax: +44 (0) 1223 755951
Registered in England: 8475531 · VAT Reg. No: GB 167 9240 79
2
1 Preface
1.1 Introduction
Abbexa’s Mini vortex mixer, abx725008, is designed specifically for mixing
substances in individual test tubes or vials at a speed of 4500 RPM. It offers versatility,
simplicity, safety and ease of use in a single package. It is intended to be used to vortex
biological substances in various laboratory settings. The substances that are usually
mixed with this device are not highly reactive or dangerous.
1.2 Features
•Brushless DC motor for maintenance-free and long life operation
•Touch start operation
•Small footprint
•Die cast base and suction cups for stability
•Highly efficient and accurate
•Low power supply
•Speed of 4500 RPM
•Silent operation (noise level < 50 dB)
•Orbital motion with a 4.5mm diameter
For Reference Only

Product Manual
Abbexa Ltd., Cambridge Science Park, Cambridge, CB4 0EY, UK
www.abbexa.com · Email: inf[email protected] · Phone: +44 (0) 1223 755950 · Fax: +44 (0) 1223 755951
Registered in England: 8475531 · VAT Reg. No: GB 167 9240 79
3
2 Installing the device
2.1 Standard accessories
•Product user manual and warranty card
2.2 Standard parts
2.3 Unpacking the device
•Check the packaging and seal condition upon receipt of the product to find whether it
has arrived intact.
•When unpacking, gently remove the device from the box.
•Plug in the power adaptor pin before connecting to the main power source.
•Read the user manual carefully before installation. Do not discard the packaging
material which can be used for future transportation.
•The device should be kept on a flat and non-slippery surface.
.
For Reference Only

Product Manual
Abbexa Ltd., Cambridge Science Park, Cambridge, CB4 0EY, UK
www.abbexa.com · Email: inf[email protected] · Phone: +44 (0) 1223 755950 · Fax: +44 (0) 1223 755951
Registered in England: 8475531 · VAT Reg. No: GB 167 9240 79
4
3 Operating the device
3.1 Start and stop operation
•This device operates by touch start.
•The mixer will automatically start when the rubber cup
is pressed down.
•The device will stop when the test tube is removed.
•The mixer has one speed setting at 4500 RPM.
4 System maintenance and troubleshooting
4.1 Safety precautions
•The vortex mixer should be used only for the application specified in the manual. It
must not be operated in hazardous or flammable environments.
•Do not move the device while it is in operation.
•Donotusesubstancesthatarehazardous,explosive or highlyreactivewith this mixer.
•Only use tubes that have a diameter of 30 mm or less.
•To avoid spillage, cover tubes before mixing contents. Do not overfill the tubes.
•If liquid is spilled on the rotor, the mixer must be cleaned immediately.
•Do not use the device if they show any signs of external mechanical or electrical
damages.
•Do not fill tubes while they are on the device. Liquid spillage may damage the device.
•Do not immerse the mixer in liquid or pour liquid over it.
4.2 Instrument disinfection
After using dangerous and/or infectious substances, disinfect the apparatus:
For Reference Only

Product Manual
Abbexa Ltd., Cambridge Science Park, Cambridge, CB4 0EY, UK
www.abbexa.com · Email: inf[email protected] · Phone: +44 (0) 1223 755950 · Fax: +44 (0) 1223 755951
Registered in England: 8475531 · VAT Reg. No: GB 167 9240 79
5
•Personal protective equipment (PPE), such as lab coats, disposable gloves and eye
protection, should be used.
•Turn off the device and unplug the power supply plug at the mains.
•Using 75% alcohol disposable wipes, clean the external surface of the apparatus.
•Wait for the instrument to fully dry before reconnecting the power supply.
4.3 Routine maintenance
•Only use a cloth with water, mild soap or a non-abrasive cleaning liquid (pH 6 – 8) to
clean the instrument. Using abrasive reagents may damage the instrument.
•If any reagents or any corrosive substances are spilled on the instrument, immediately
wash with a wet cloth and water.
•The exterior of the equipment should be cleaned regularly and at least on a monthly
basis.
•Good operating practice may extend the life of the product.
4.4 Troubleshooting
The table below lists some common problems
encountered when using the instrument. If the problems are
still not resolved after following the suggested solutions,
please contact a service engineer.
Issue Possible causes Solution
The device is only
partially working.
Small screw in the
bottom may be
loose.
Tighten by ½ or 1 turns.
Device will not start.
Small screw in the
bottom may be
loose.
Tighten by 1-2 turns.
Device is running
continuously
without touch start.
Small screw in the
bottom may be
too tight.
Loosen by 1-2 turns
Table 1. Troubleshooting table
For Reference Only

Product Manual
Abbexa Ltd., Cambridge Science Park, Cambridge, CB4 0EY, UK
www.abbexa.com · Email: inf[email protected] · Phone: +44 (0) 1223 755950 · Fax: +44 (0) 1223 755951
Registered in England: 8475531 · VAT Reg. No: GB 167 9240 79
6
5 Specification parameters
Motor type Brushless DC motor
Maximum speed 4500 RPM
Speed accuracy ± 5 %
Tube diameter Up to 30 mm
Shaker diameter 4.5 mm
Operation type Touch
Size (L x W x H) 100 x 100 x 70 mm
Weight 0.55 kg
Input voltage 100-240 V (A/C), 50/60 Hz
Output voltage and current 9 V (DC), 1.5 A
Power consumption 15 W
Operating temperature 5 to 40 °C
Permissible relative moisture < 80%
Table 2.Specification table
6 Product disposal
This symbol indicates that the product is planned for
use in a country complying with the Waste Electrical and
Electronic Equipment EU Directive, 2012/19/EU. This
symbol indicates that the product must not be disposed of
with unsorted municipal waste. It is the product user’s
responsibility to correctly dispose of the waste equipment
by handling it over to an authorised facility to
decontaminate the waste equipment from biological,
chemical and/or radiological hazards prior to disposal.
For Reference Only

Product Manual
Abbexa Ltd., Cambridge Science Park, Cambridge, CB4 0EY, UK
www.abbexa.com · Email: inf[email protected] · Phone: +44 (0) 1223 755950 · Fax: +44 (0) 1223 755951
Registered in England: 8475531 · VAT Reg. No: GB 167 9240 79
7
7 Warranty statement
This product is warranted to be free from defects in material and workmanship for a
period of one (1) year from date of purchase. The product will be duly repaired upon
prompt notification in compliance with the following conditions:
•This warranty is valid only if the product is used for its intended purpose and
within the guidelines specified in this instruction manual.
•This warranty does not cover damage caused by accident, neglect, misuse,
improper service, natural forces or other causes not arising from defects in the
original material or workmanship.
•This warranty does not cover any incidental or consequential damages,
commercial loss or other damages from the use of this product.
•This warranty is invalidated by any non-factory modification, which will
immediately terminate all liabilities on us for the products or damages caused
by its use. The customer shall be responsible for the product or use of products,
as well as any supervision required for safety.
•If the product must be returned to the distributor, the customer is responsible
for ensuring the product is suitably packed. The customer is also responsible
for any shipping charges that may arise.
•This warranty is only applicable to the original purchaser.
•This warranty is only valid if it is registered with the supplier within 30 days
from the purchase date.
Some regions or states do not allow limitation on the length of implied warranties or
the exclusion or limitation of incidental or consequential damages. This warranty gives
you specific legal rights. This warranty is given expressly in lieu of all other warranties,
expressed or implied.
The purchaser agrees that there is no warrantyof merchantability or of fitness for any
intended purpose and that there are no other remedies or warranties, expressed or
implied, which extend beyond the description on the face of the agreement.
Products received without proper authorisation will not be entertained. All items
returned for service should be sent by prepaid postage in the original packaging or other
suitable carton. The package must be suitably paddedto avoid damage in transit. We will
not be responsible for damage caused by improper packaging.
For Reference Only
Table of contents