6 Installation and Operating Instructions
ABS lifting station Nirolift & Sanisett
4 Set-up and Installation
Installation and dimensions (mm) of the Nirolift/Sanisett (Figure 1-6)
1 Synthetic tank 12 Cable inlet, odour-tight
2Waste-water pump Robusta (not supplied with tank
must be ordered separately)
13 Socket
3Bend (Accessory) 14 Concrete
4Upper tting (adjustable 360°) 15 Screed
5Cover plate with oor run-off and odour lock (only
suitable for foot trafc).
16 Floor tiles
6 Two inlet ports DN 100 (Nirolift) 100/150 (Sanisett) 17 Motor connection cable
7 Discharge line for connection P.V.C pipe 40 mm
(Nirolift), 50 mm (Sanisett)
18 Branch pipe (T-piece)
8Seal to nished oor 1) Anti-siphon loop
9 Discharge line. --- Approximate excavation dimensions
10 Shut-off valve (Accessory) * Cable ties
11 Vent/cable pipe DN 70, lead to above roof level ** Installation cover (on completion replaced by Pos. 5)
4.1 Installation of the collection tank
Set the collection tank on a bed of sand in the prepared opening of dimensions approximately 600x600x750mm
Nirolift and 1100x900x850 mm Sanisett in a frost free area and ensure that it is horizontal in all directions.
Place the tank in such a manner that the vent openings are in line with the chosen pipe directions.
If for reasons of the progress of construction work it is impossible to install the venting and pressure pipes
before pouring of the concrete one has to use a polystyrene core between the tank and the intended wall to
allow an assembly of the pipes later.
NOTE During concreting, the collection tank should be prevented from oating upwards
and should also be closed off with the plastic cover. This will avoid the danger that
the edge of the tank could be pressed inwards.
If there is a danger of pressure arising due to ground water, then the concrete surround of the collection tank
must be laid at the same time as the cellar oor, and should be closed off tightly on all sides (including under
the tank). The pipes must also be laid in the concrete.
If there is no danger of ground water pressure then a gravel bed and cementing in of the upper portion of the
collection tank is adequate
4.2 Installation of the submersible pump
The Nirolift has been designed for tting of submersible pumps from the Robusta, Coronada or
MF 054-334 series.
The Sanisett has been designed for tting of submersible pumps from the Robusta, Coronada or MF or
Piranha 08/09 series.
A suitable installation Kit should be chosen depending on the type of pump selected.
NOTE The connection or junction piece is already tted in the Nirolift or Sanisett collection
tank.
The tting of the submersible pumps is given in the leaet supplied with the installation kit.