AC Infinity CONTROLLER 67 User manual

USER MANUALUSER MANUAL
CONTROLLER 67


3
WELCOME
Thank you for choosing AC Infinity. We are committed to product quality and friendly customer service.
If you have any questions or suggestions, please don’t hesitate to contact us. Visit www.acinfinity.com
and click contact for our contact information.
EMAIL
support@acinfinity.com
WEB
www.acinfinity.com
LOCATION
Los Angeles, CA

4
MANUAL CODE CTR6720061X2
PRODUCT
CONTROLLER 67
MODEL
CTR67A
UPC-A
819137021426
COMPATIBILITY
This controller is compatible with AC Infinity fan models that contain an EC-motor. Typically, EC-motor
fans will have a separate cord coming out of it for the power and the controller. Note that certain
models that used to have a DC-motor now contain an EC-motor in newer versions.
EC Motor - Compatible AC or DC - NOT Compatible
Please visit www.acinfinity.com to check for the latest models compatible with this controller.

5
MANUAL INDEX
Compatibility ..................................................................................
Manual Index .................................................................................
Key Features .................................................................................
Product Contents ...........................................................................
Powering and Setup ......................................................................
Daisy Chain and Setup .................................................................
Programming .................................................................................
Other Settings ...............................................................................
Other AC Infinity Products .............................................................
Warranty ........................................................................................
Page 4
Page 5
Page 6
Page 7
Page 8
Page 10
Page 11
Page 23
Page 24
Page 25

6
KEY FEATURES
SENSOR PROBE
The corded probe is
constructed of stainless steel
to ensure precise temperature
and humidity readings.
SMART CONTROLLER
Features automation controls
that activate the fan according
to temperature, humidity, timer,
and schedules.
ACTIVE MONITORING
LCD display shows key
data including fan speed,
temperature, humidity, trends,
clock, countdowns, and more.
STEEL FRAME
Steel backplate with a black
powder coated finish. Includes
screws to securely mount the
controller to the wall.
EXTRA CORD LENGTH
Extended cord length of 144
inches (12 feet) for ease of
management and flexible
mounting options.
ADVANCE SETTINGS
Includes more setting options
such as Fahrenheit / Celsius
Toggle, Clock, Calibration, and
Transition.

7
PRODUCT CONTENTS
SENSOR
PROBE
(x1)
MACHINE SCREWS
(WALL MOUNT)
(x2)
SMART
CONTROLLER
(x1)
WOOD SCREWS
(WALL HANG)
(x2)
WIRE
TIE
(x1)
WOOD SCREWS
(WALL MOUNT)
(x2)

8
POWERING AND SETUP
STEP 1
Locate the molex connector of your fan and
plug it into the fan port at the bottom side of the
controller.
STEP 2
Locate the connector plug of the sensor probe
and plug it into the sensor port at the bottom
side of the controller.

9
STEP 3
Position the corded sensor probe and secure it
by using the included zip ties and tie mounts.
STEP 4
Lastly, to power the fan, plug the fan's
power cord into a wall outlet. The controller
will receive power from the fan to operate.
POWERING AND SETUP

10
DAISY CHAIN AND SETUP
The fan controller can power up to two compatible fans to share the same programming. The
compatible fans do not need to be the same model or part of the same product series. Please
see page 4 for compatibility details.
Note that the controller receives power to operate from the fans. The controller only supplies
programming and not power. Each linked fan will still require its own power source.

11
PROGRAMMING
1. MODE BUTTON
This button cycles through each of the controller’s mode: OFF, ON, AUTO (4 triggers), TIMER TO
ON, TIMER TO OFF, CYCLE (On and Off), and SCHEDULE (On and Off).
4. PROBE TEMPERATURE
Current temperature that the probe is detecting. Displays “--“ if no probe is plugged in. Includes a
trend indicator that signals a rise, steady, or fall in temperature within the last hour.
3. SETTING BUTTON
This button cycles through each of the controller’s settings: DISPLAY BRIGHTNESS, F/C, CLOCK,
CALIBRATION (Temperature and Humidity), and TRANSITION (Temperature and Humidity).
2. UP / DOWN BUTTON
Adjusts the parameters of the mode that you are in. In most modes, the up button increases and
down button decreases the setting. Holding both buttons simultaneously sets the parameters to off.
21 3
HIGH TEMP.
LOW TEMP.
AUTO AM
PM
HIGH HUMID.
LOW HUMID. TO
ON
4
5
678
9
10
11

12
8. CURRENT TIME
Displays the current time. The internal battery sustains the clock so it does not default to 00:00 if
power is cut off. Please see page 18 for instructions on how to set up the clock time.
6. CONTROLLER MODE
Displays the mode that the controller is currently in. Pressing the mode button cycles through the
available modes.
9. FAN SPEED
Displays the current speed in which the fan is running. Includes a trend indicator that signals if the fan
is currently rising, falling or holding steady.
10. COUNTDOWN
Displays TO ON or TO OFF countdown to show the amount of time before the timer to on, timer to
off, cycle, or schedule modes activates or deactivates the fan. TO ON represents the amount of time
that is left before the fan turns on. TO OFF represents the amount of time that is left before the fan
turns off.
11. USER SETTING
Displays the value you have set for the current mode that you are in. Press the up or down button to
adjust the value.
7. STATUS ICONS
Flashes or displays the alert icons from the controller. Icons include TIMER ALERT and DISPLAY
LOCK.
5. PROBE HUMIDITY
Current humidity that the probe is detecting. Displays “--“ if no probe is plugged in. Includes a trend
indicator that signals a rise, steady, or fall in humidity within the last hour.
PROGRAMMING

13
PROGRAMMING
CONTROLLER MODES
Pressing the mode button will cycle through the controller’s available programming modes: OFF, ON,
AUTO (4 triggers), TIMER TO ON, TIMER TO OFF, CYCLE (On and Off), and SCHEDULE (On and
Off).
ON MODE
Your fan will actively run at the speed set,
regardless of the probe's reading. The ON mode
also serves as the maximum speed setting the
other modes will run in.
OFF MODE
Your fan will not run while in this mode. However,
the fan speed set while in this mode establishes
the minimum speed in the other modes. When the
fan is triggered to turn OFF in all other modes, it
will instead run at the speed set here.
AUTO MODE (HIGH TEMPERATURE TRIGGER)
Pressing the up or down button sets the high
temperature trigger. The fans will activate if the
probe’s reading meets or exceeds this threshold.
Once triggered, the fan will gradually ramp up to the
speed set in ON mode. If the probe’s reading falls
below this trigger point, the fans will gradually slow
down to a stop or at the speed set in OFF mode.
You may set this trigger below the low temperature
trigger to create a specific range in which the fan is
active.
Note that this trigger can activate as long
as you are in AUTO Mode, even if you are
viewing a different trigger within AUTO Mode.
If there is a speed set in OFF Mode other
than zero, the fans will run at that speed when
triggered to turn off.

14
PROGRAMMING
AUTO MODE (LOW TEMPERATURE TRIGGER)
Pressing the up or down button sets the low
temperature trigger. The fans will activate if the
probe’s reading meets or falls below this threshold.
Once triggered, the fan will gradually ramp up to the
speed set in ON mode. If the probe’s reading rises
above this trigger point, the fans will gradually slow
down to a stop or at the speed set in OFF mode.
You may set this trigger above the high temperature
trigger to create a specific range in which the fan
is active.
AUTO MODE (HIGH HUMIDITY TRIGGER)
Pressing the up or down button sets the high
humidity trigger. The fans will activate if the probe’s
reading meets or exceeds this threshold.
Once triggered, the fan will gradually ramp up to the
speed set in ON mode. If the probe’s reading falls
below this trigger point, the fans will gradually slow
down to a stop or at the speed set in OFF mode.
You may set this trigger below the low humidity
trigger to create a specific range in which the fan
is active.
Note that this trigger can activate as long
as you are in AUTO Mode, even if you are
viewing a different trigger within AUTO Mode.
If there is a speed set in OFF Mode other
than zero, the fans will run at that speed when
triggered to turn off.
Note that this trigger can activate as long
as you are in AUTO Mode, even if you are
viewing a different trigger within AUTO Mode.
If there is a speed set in OFF Mode other
than zero, the fans will run at that speed when
triggered to turn off.

15
PROGRAMMING
AUTO MODE (LOW HUMIDITY TRIGGER)
Pressing the up or down button sets the low
humidity trigger. The fans will activate if the probe’s
reading meets or falls below this threshold.
Once triggered, the fan will gradually ramp up to the
speed set in ON mode. If the probe’s reading rises
above this trigger point, the fans will gradually slow
down to a stop or at the speed set in OFF Mode.
You may set this trigger below the low humidity
trigger to create a range in which the fan is active.
TIMER TO ON MODE
In this mode, press the up or down button to set
a countdown time. Once the timer ends, the fans
will trigger to run at the speed set in ON Mode. If
there was a speed set in OFF Mode other than
zero, then the fans will run at that speed during the
countdown.
The countdown will begin if no buttons are pressed
for 5 seconds. The time left on the countdown is
shown on the display, in the section below the
current fan speed. Leaving the timer mode while
the countdown is running will pause it until you
return to this mode.
If there is a speed set in OFF Mode other
than zero, the fans will run at that speed
when triggered to turn off.
Note that this trigger can activate as long
as you are in AUTO Mode, even if you are
viewing a different trigger within AUTO Mode.
If there is a speed set in OFF Mode other
than zero, the fans will run at that speed when
triggered to turn off.

16
PROGRAMMING
TIMER TO OFF MODE
In this mode, press the up or down button to set a
countdown time. The fans will run at the speed set
in ON Mode until the countdown ends. If there was a
speed set in OFF Mode other than zero, then the fans
will run at that speed after the end of the countdown.
The countdown will begin if no buttons are pressed for
5 seconds. The time left on the countdown is shown
on the display, in the section below the current fan
speed. Leaving the timer mode while the countdown
is running will pause it until you return to this mode.
Leaving the timer mode while the countdown is
running will pause it until you return to this mode.
CYCLE MODE (ON AND OFF)
In this mode, set an on duration and an off duration
for the fan to cycle through continuously. Press the
up or down button to first set a duration for the fan
to be on and then press the mode button again, to
set a duration for the fan to be off. When the fan is
triggered to be on, it will run at the speed set in ON
Mode. When the fan is triggered to be off, it will run
at the speed set in OFF Mode.
The countdown will begin if no buttons are pressed
for 5 seconds. The time left on the countdown
before the next on or off phase is shown on the
display, in the section below the current fan speed.
Leaving the cycle mode while the countdown is
running will pause it until you return to this mode.
If there is a speed set in OFF Mode other
than zero, the fans will run at that speed
when triggered to turn off.
If there is a speed set in OFF Mode other
than zero, the fans will run at that speed
when triggered to turn off.
PM
OFF
TO
OFF

17
PROGRAMMING
SCHEDULE MODE (ON AND OFF)
In this mode, set an on clock-time and an
off clock-time schedule for the fan to follow
through daily. Press the up or down button
to first set up an on clock-time for when the
fan will be on and then press the mode button
again, to set an off clock-time for when the fan
will be off. When the fan is triggered to be on, it
will run at the speed set in ON Mode. When the
fan is triggered to be off, it will run at the speed
set in OFF Mode. Please be sure to set the
current clock time under settings.
The countdown will begin if no buttons are
pressed for 5 seconds. The time left on the
countdown before the next on or off phase is
shown on the display, in the section below the
current fan speed. The fan will not follow this
schedule if you leave this mode. If you reenter
the schedule mode, it will continue to follow the
latest schedule you have set.
TO
ON
TO
ON
If there is a speed set in OFF Mode other
than zero, the fans will run at that speed
when triggered to turn off.
ADV. MODE
Advanced programs are automation, alarm,
and/or notification settings created in the AC
Infinity controller app. Its icon will display when
an advanced program is set. “ADV” will appear
when an automation advanced program is
activated.

18
PROGRAMMING
F/C SETTING
In this setting, change the displayed units to
Fahrenheit or Celsius. Press the up or down
button to cycle through F and C. All displayed
units on the controller will change automatically
with your setting.
DISPLAY SETTING
In this setting, adjust the brightness of the display
and auto-dimming. Press the up or down button
to cycle through 1, 2, 3, A2 and A3. The highest
brightness is 3 while the lowest brightness is 1. The
settings 1, 2, and 3 are not auto-dimming, and the
display will continuously be shown at that brightness
level. In A2, the display will be shown at brightness 2
but fall to brightness 1 whenever the controller is not
being adjusted after 15 seconds. In A3, the display
will be shown at brightness 3 but fall to brightness 1
whenever the controller is not being adjusted after
15 seconds.
CONTROLLER SETTINGS
Pressing the setting button will cycle through the controller’s available settings: DISPLAY, F/C, CLOCK,
CALIBRATION TEMPERATURE, CALIBRATION HUMIDITY, TRANSITION TEMPERATURE, and
TRANSITION HUMIDITY.

19
PROGRAMMING
CALIBRATION TEMPERATURE SETTING
In this setting, adjust the temperature reading
that the sensor probe is measuring. Press the
up or down button to increase or decrease the
data figure by 2°F (or 1°C) increments. The
calibration cycle ranges from -8°F to 8°F (or
-4°C to 4°C) and will be applied to the sensor
probe’s measurements.
CALIBRATION HUMIDITY SETTING
In this setting, adjust the real humidity
reading that the sensor probe is measuring.
Press the up or down button to increase or
decrease the data figure by 1% increments.
The calibration cycle ranges from -8% to
8% and will be applied to the sensor probe’s
measurements.
CLOCK SETTING
In this setting, adjust the current clock time.
Press the up or down button to increase or
decrease the time. Once you cycle through
12:00 each time, the units will automatically
change to AM or PM. The current clock time
will be shown at the top right corner of display.

20
PROGRAMMING
TRANSITION TEMPERATURE SETTING
In this setting, adjust the incremental rules in which
the fan speed ramps up or down for temperature
triggers in AUTO Mode. Press the up or down
button to cycle through 0°F to 8°F (or 0°C to 4°C)
to set a differential increment. Once setup, when
the sensor temperature first meets or exceeds
the high temperature trigger, the speed will start
at one speed above the speed set in OFF Mode.
Then for every differential increment that the sensor
temperature is different from the set temperature,
the speed of the fan will ramp up by one additional
speed level. This continues until the fan reaches the
speed set in ON Mode.
For example, let’s assume your high temperature
trigger is set at 80°F, the speed set in OFF Mode
is 0, and the speed set in ON Mode is 6. If the
differential increment was set to 0°F, then the fan
would have just triggered to run at speed 6 when
the sensor temperature meets or exceeds 80°F.
However, if the differential increment was set to 2°F.
Then the fan would start running at speed 1 when
it meets or exceeds 80°F. Then at speed 2 when
it meets or exceed 82°F. Then at speed 3 when it
meets or exceeds 84°F. Then at speed 4 when it
meets or exceed 86°F. Then at speed 5 when it
meets or exceed 88°F. Then from 90°F or higher, it
will run at speed 6 which was the speed set in ON
Mode.
This manual suits for next models
1
Table of contents
Other AC Infinity Controllers manuals

AC Infinity
AC Infinity CONTROLLER 69 User manual

AC Infinity
AC Infinity CTR69X User manual

AC Infinity
AC Infinity AC-CRA5 User manual

AC Infinity
AC Infinity AC-CTC7 User manual