manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Accuphase
  6. •
  7. Amplifier
  8. •
  9. Accuphase E-600 User manual

Accuphase E-600 User manual

E-600 is a succession model of E-560 and flag ship
integrated amplifier of Accuphase.
We name it E-600 instead of E-five hundred something
because the progress is more than ‘change of model’.
1
The big difference in appearance is LED bar graph
meters instead of needle meters.
2
Precise and well-designed volume sensor mechanism is
installed.
The volume mechanism is modified from C-2820’s.
It is consisted of CNC machining aluminum block, extra-
thick shaft and so on.
The volume knob provides very smooth touch and feel.
The drive sound by a remote commander becomes more
silent than before.
3
AAVA is re-designed to achieve low noise.
AAVA in E-600 achieves low noise by the paralleled
buffer amplifier and paralleled V-I converter in larger two
units.
Then the input stage of power amplifier is low-noised.
As a result, the overall noise of E-600 is 56%(-5dB) of E-
560.
4
The Damping-factor is an index of speaker driving ability.
By using Balanced Remote-sensing, MOS-FET switch
and Low impedance components, E-600 achieves
higher Damping-factor than E-560.
E-560 is 200 and E-600 is 500.
It is 2.5 times higher.
*Damping-factor = 8 ohm / Zo
Zo : Output impedance of amplifier
By CEA-490-A R-2008 standard
5
Remote-sensing is the technique to lower the output
impedance of amplifier by the negative feedback with
signal sensing from close up the speaker terminals.
Balanced Remote-sensing is the technique to make
impedance even lower by GND sensing and the negative
feedback of GND level with adding the signal sensing.
Not only Damping-factor is improved but also Total
Harmonic Distortion and Intermodulation Distortion get
better by Balanced Remote-sensing.
6
MOS-FET switch is mounted on the speaker protection.
Generally, a mechanical relay is used for the power-amp
output for speaker protection.
E-600 replaces a mechanical relay with MOS-FET switch.
As a result, the reliability, Damping-factor and sound
quality is improved.
Super-heavy-gauge edgewise coil is chosen because the
DC-resistance is extremely low.
Output coil is essential for stable power amplifier
movement.
*On-resistance of MOS-FET used for E-600: 2.6mOHM
7
E-600 accepts the new digital input board, DAC-40.
You can see the figure of music signal sampling
frequency input into DAC-40 on the front panel display.
Balanced-type input and output are additionally equipped
as Pre-Output and Power-Input.
The remote commander is elegant and high-quality.
8

Other Accuphase Amplifier manuals

Accuphase E-202 User manual

Accuphase

Accuphase E-202 User manual

Accuphase E-550 Operating and installation instructions

Accuphase

Accuphase E-550 Operating and installation instructions

Accuphase E-212 Operating and installation instructions

Accuphase

Accuphase E-212 Operating and installation instructions

Accuphase M-8000 Operating and installation instructions

Accuphase

Accuphase M-8000 Operating and installation instructions

Accuphase E-307 Operating and installation instructions

Accuphase

Accuphase E-307 Operating and installation instructions

Accuphase C-2810 Operating and installation instructions

Accuphase

Accuphase C-2810 Operating and installation instructions

Accuphase E-350 User manual

Accuphase

Accuphase E-350 User manual

Accuphase E-460 User manual

Accuphase

Accuphase E-460 User manual

Accuphase A-60 Operating and installation instructions

Accuphase

Accuphase A-60 Operating and installation instructions

Accuphase E-407 User manual

Accuphase

Accuphase E-407 User manual

Accuphase E-213 User manual

Accuphase

Accuphase E-213 User manual

Accuphase E-308 Operating and installation instructions

Accuphase

Accuphase E-308 Operating and installation instructions

Accuphase E-213 Operating and installation instructions

Accuphase

Accuphase E-213 Operating and installation instructions

Accuphase P-7100 User manual

Accuphase

Accuphase P-7100 User manual

Accuphase P-7100 Operating and installation instructions

Accuphase

Accuphase P-7100 Operating and installation instructions

Accuphase E-202 User manual

Accuphase

Accuphase E-202 User manual

Popular Amplifier manuals by other brands

TIC AMP88 quick start guide

TIC

TIC AMP88 quick start guide

Lab.gruppen fP Series FP 6400 Specifications

Lab.gruppen

Lab.gruppen fP Series FP 6400 Specifications

RCS LSA-3400 operating instructions

RCS

RCS LSA-3400 operating instructions

Ayre K-1x owner's manual

Ayre

Ayre K-1x owner's manual

Maxview MHA12CD/S User instructions

Maxview

Maxview MHA12CD/S User instructions

Atoll Electronique AM400 owner's manual

Atoll Electronique

Atoll Electronique AM400 owner's manual

Russound R1250MC user manual

Russound

Russound R1250MC user manual

Design by Mr. K PPA - 01 owner's manual

Design by Mr. K

Design by Mr. K PPA - 01 owner's manual

RF-Lambda REMC18G40GN manual

RF-Lambda

RF-Lambda REMC18G40GN manual

XINDAK XA6950 instructions

XINDAK

XINDAK XA6950 instructions

Becker IC6100-2-(01) Installation and operation

Becker

Becker IC6100-2-(01) Installation and operation

icon Audio MB90 MK IIm instruction manual

icon Audio

icon Audio MB90 MK IIm instruction manual

Vicon V-DA-8-16 Installation & operation manual

Vicon

Vicon V-DA-8-16 Installation & operation manual

moon 250i owner's manual

moon

moon 250i owner's manual

Schiit LYR 2 SCH-03-2 owner's manual

Schiit

Schiit LYR 2 SCH-03-2 owner's manual

AudioSource AMP 210 owner's manual

AudioSource

AudioSource AMP 210 owner's manual

Pioneer PRS-X720 owner's manual

Pioneer

Pioneer PRS-X720 owner's manual

Mackie UP4061 instruction manual

Mackie

Mackie UP4061 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.