AccuTemp Accu-Steam G2 Series Administrator Guide

MP5017-2002
AccuTemp Products INC
8415 N. Clinton Park Dr, Fort Wayne IN 46825
www.accutemp.net
INSTALLATION/OPERATORS MANUAL
ACCUSTEAM GAS G2 GRIDDLE
Serial Number:
Model:
MODELS
GG24A/GG36A/GG48A
GG24B/GG36B/GG48B
PG24A/PG36A/PG48A
PG24B/PG36B/PG48B
This manual should be retained for future
reference

MP5017-2002 Accu-Steam Gas Griddle 1
The State of California enacted the California Safe Drinking Water and Toxic
Enforcement Act of 1986, (Prop. 65), which “prohibits any person in the course
of doing business from knowingly and intentionally exposing any individual to
a chemical known to the State of California to cause cancer or reproductive
toxicity without first giving clear and reasonable warning to such individuals.”
The Governor’s Scientific Advisory Panel added Carbon Monoxide to the list of
hazardous chemicals known to cause reproductive harm.
In order to establish full compliance with Proposition 65, a yellow warning label has
been attached to each gas fired unit manufactured by AccuTemp Products,Inc.
Carbon monoxide would not be present in concentrations that would pose a
“significant risk” to the consumer when the equipment is installed, operated and
maintained as follows:
1. Installed in accordance with all local codes, or in the absence of local codes,
with the current National Fuel Gas Code Z223.1, latest addenda.
2. Installed under a properly designed and operating exhaust hood.
3. Connected to the type of gas for which the unit is equipped.
4. Proper appliance pressure regulator installed on the gas supply line and adjusted
for the manifold pressure marked on the rating plate.
5. Adequate air supply to the unit and adequate clearance around the flue.
6. The equipment is operated in the manner intended using the proper utensil for
that type of appliance.
7. Keep the equipment clean and have it checked periodically.
8. Burner air adjustments, mechanical maintenance and repairs should be
performed by qualified service personnel.
WARNING

MP5017-2002 Accu-Steam Gas Griddle 2
TABLE OF CONTENTS
SAFETY WARNINGS INFORMATION PAGE 3
GENERAL INFORMATION PAGE 7
START UP FORM PAGE 9
INSTALLATION PAGE 12
OPERATION - USE PAGE 19
OPERATION CLEANING PAGE 29
PLANNED MAINTENANCE PAGE 30
SERVICE & TROUBLESHOOTING PAGE 33
WARRANTY PAGE 36
DOCUMENT HISTORY
CURRENT
REVISION
DATE PRIOR
REVISION
DATE CHANGE
2002 02/13/2020 1907 07/26/2019 Added AccuSteam Stand
Installation Instructions

MP5017-2002 Accu-Steam Gas Griddle 3
1. WARNING SYMBOL DEFINITIONS
SYMBOL DEFINITIONS
Symbols are used to attract your attention to possible dangers. They are only
eective if the operator uses proper accident prevention measures. Some of the
symbols are boxed text; while others maybe just picture icons. Please give this
information the respect they deserve for safe operation.
Symbol Icons
Below are definitions of the symbol icons used
in this manual.
CAUTION -
HOT SURFACE
DANGEROUS
VOLTAGE
EARTH GROUND
DANGER
Indicates an imminently hazardous
situation; which, if unchanged, will result
in death or serious injury.
CAUTION
Indicates a potentially hazardous
situation; which, if unchanged, will
result in minor or moderate injury.
NOTE
Advises the reader of information
or instructions, vital to the
operation or maintenance of the
equipment.

MP5017-2002 Accu-Steam Gas Griddle 4
The safety instructions listed below on this page should be posted in a
prominent location as a reminder of safe practices as well as recommended
actions to follow in the event of an equipment or facility utility issue.
In the event a gas odor is detected, shut down all appliances at the main gas shut-o valve
and contact the local gas company or gas supplier service.
1.1 IMPORTANT FOR YOUR SAFETY
WARNING
In the event of a power failure, do not attempt to operate this appliance.
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or
any other appliance.
Improper installation, adjustment, alteration, service or maintenance can cause property
damage, injury or death. Read the installation, operating, and maintenance instructions
thoroughly before installing or servicing this equipment.
Only qualified service technicians/electricians should install this appliance to ensure that all
electrical and safety requirements are met and that all wiring is installed in accordance with
all national, state and local electrical codes.
WARNING
WARNING
WARNING
WARNING

MP5017-2002 Accu-Steam Gas Griddle 5
Improper installation, adjustment,
alteration, service or maintenance can cause
property damage, injury or death. Read the
installation, operating and maintenance
instructions thoroughly before installing or
servicing the equipment.
A five minute complete shuto must be
observed before the appliance is relighted.
Intended for other than household use.
Plug the appliance into a properly
grounded electrical outlet of the correct
voltage, size and plug configuration. If they
do not match, contact a qualified electrician
to determine the proper voltage and size and
install the proper electrical outlet.
Do not connect to a circuit operating
more than 150V to ground.
To avoid any personal injury or damage to
the unit do not pull the appliance by the power
cord.
To prevent any injury, discontinue any use
if power cord is frayed or worn.
To prevent any injury or damage this
commercial appliance must be installed by a
qualified electrician.
To avoid any injury, turn the power o,
unplug from the power source and allow to
cool before performing any maintenance.
To avoid electrical shock or personal
injury, do not steam clean or use excessive
water on this commercial appliance.
This product has no “user” serviceable
parts. To avoid injury or damage to the
commercial appliance use only Authorized
AccuTemp Service Agents and Genuine
Replacement Parts when service is required.
Genuine AccuTemp Replacement Parts are
specified to operate safely in the environments
in which they are used. Some aftermarket parts
or generic replacements parts do not have
the same specifications to operate safely in
AccuTemp equipment. It is imperative that to
use Genuine AccuTemp Replacement Parts
to avoid injury or damage to the commercial
appliance.
Always disconnect from power source
before cleaning or servicing.
Any in-the-field modification that bypass
the built-in safety features will result in personal
injury or death.
This appliance must be properly
grounded, in accordance with all National,
State or local electrical codes.
This appliance has a totally unique design
and is constructed unlike any other griddle
on the market today. Any modification may
permanently damage the appliance.
This appliance must be level for proper
operation and to reduce possible damage to
this commercial appliance.
This appliance is heavy, for safe handling,
the installer should obtain help as needed
or employ appropriate material handling
equipment to remove the commercial
appliance from the skid and move to the final
location in the building.
IMPORTANT: Read the following safety installation to avoid personal injury or death and to avoid
damage to the equipment or property
1.2 WARNING & CAUTION NOTES

MP5017-2002 Accu-Steam Gas Griddle 6
Temperatures in and around the appliance
are very hot and can cause severe burns.
To avoid damage to the cooking surface
of this appliance do not use abrasive cleaners
such as a griddle stone or brick.
To avoid personal injury or damage to the
appliance do not use a water jet to clean the
unit.
To avoid damage to the appliance do not
leave a chlorine sanitizer in contact with the
stainless steel longer than 10 minutes.
To avoid severe burns slowly remove the
grease reservoir to avoid spilling the contents.
It is recommended to let it cool before
removing.
To avoid damage to the appliance do not
leave a chlorine sanitizer in contact with the
stainless steel longer than 10 minutes.
To avoid severe burns slowly remove the
grease reservoir to avoid spilling the contents.
It is recommended to let it cool before
removing.

MP5017-2002 Accu-Steam Gas Griddle 7
2. General Information
2.1 Unit Specifications
Fig 2.A
Fig 2.B
THE UNIT SHOULD NOT BE FLUSH MOUNTED UNDER ANY CIRCUMSTANCES.

MP5017-2002 Accu-Steam Gas Griddle 8
2.2 EQUIPMENT DATA PLATE
Model: AA B CCC D E FF GG
Example: GGF1201A4850
Ais the base model N = Natural Gas, P = Propane
B is the model configuration
CCC is the supply Voltage
Dis the number of phases: 1 or 3
Eis the depth
F is the width
Gis the special configuration
Fig 2.C
The Serial Number is also stamped into
the upper right corner of the front plate,
above the grease tray.
Fig 2.D

MP5017-2002 Accu-Steam Gas Griddle 9
To register this AccuTemp product for warranty complete the following items:
1. Complete the Installation/Operational Checklist and Warranty Registration Form enclosed in
the document packet that was sent with the appliance.
2. Mail, fax or scan and send via e-mail the form to AccuTemp Products, Inc to the contacts listed
for each type on the form.
If you have any questions about warranty registration please contact our technical service group.
They are available 7 days a week from 7:00 am to 7:00 PM EST.
Toll Free 800 480-0415
Oce 260 469-3040
Fax 260 469-3045
Email -Service service@AccuTemp.net
Email-Parts parts@AccuTemp.net
Web Site www.AccuTemp.net

MP5017-2002 Accu-Steam Gas Griddle 10
• AccuTemp Products, Inc. is not responsible for the installation and/or modifications to the electrical or
gas supply sources.
• It is recommended that the wall receptacle be placed as low as State and Local codes allow.
Placement in high heat zones such as, just above, below or beside the exhaust flue, will cause service
issues that will not be covered under the product warranty.
• An external regulator should not be used unless the supply gas pressure is more than 0.5 psig/14”WC
• If the altitude is greater than 3,000 feet above sea level, contact the AccuTemp Technical Services
Department to verify the correct orifice size for the main burners.
SERIAL NUMBER: MODEL NUMBER:
Location Name:
Street Address:
State/ Zip Code:
Building Name/#:
Contact Name:
Phone:
Email:
Date:
Service Company:
Street Address:
State/ Zip Code:
Service Phone #:
Technicians Name:
Technicians Email:
Additional Info:
This Start-Up Form must be completely filled out, emailed, faxed or mailed or emailed to the
AccuTemp Technical & Customer Support Department, before the warranty is activated.
1. Is the wall receptacle placed in a low heat zone? Y N
2. When measured across the fuses, is the voltage 120V (+/- 10%) Y N
3. Is the griddle being installed at an altitude greater than 2,000 feet (Circle Y/N) Y N
4. Is this griddle installed using the legs or stand provided (flush mounting will void
warranty). Y N
5. Is the griddle level? (Circle Y/N) Y N
6. Is there sucient spacing to ensure maximum airflow for proper combustion (Circle
Y/N) Y N
7. If the griddle has legs, have the (4) rubber foot tips been installed (Circle Y/N) Y N
8. Is the griddle hard connected to the gas supply line? (Circle Y/N) Y N
9. If the griddle is connected with a 3/4” flexible commercial grade gas hose? (Circle
Y/N) Y N
10. If yes, is a restraining device used? (Circle Y/N) Y N
AccuTemp Products, Inc
Attn: Technical & Customer Support Department
8415 North Clinton Park
Ft. Wayne, IN 46825
Phone: 260.469.0415 or 800.480.0415 Fax: 260.493.8914 Email: service@AccuTemp.net
ACCU-STEAM Gas Griddle Start-Up Form

MP5017-2002 Accu-Steam Gas Griddle 11
9. Is an external gas regulator connected to the griddle (Circle Y/N) Y N
10. What is the Length and Width of the Gas Supply Line L W
11. Gas Pressure measurements
Natural Gas: Static WC Dynamic WC
Dynamic pressure should be 5”WC (Regulator valve pressure tap - 1/8NPT)
Propane: Static WC Dynamic WC
Dynamic pressure should be 10”WC (Regulator valve pressure tap -1/8NPT)
12. What is the measured flame sense on the unit when the main burners are lit?
DCuA (microampere)
ACCU-STEAM Gas Griddle Start-Up Form (continued)
Temperature Verification
1. What is the customers normal operating temperature for the Griddle? °F
2. Using a weighted contact temperature probe with digital thermometer, does the
surface temperature match the set temperature on the griddle controller? (Circle
Y/N)
Y N
3. Does the griddle heat light cycle ON/OFF once the surface temperature has met the
set temperature? (Circle Y/N) Y N
4. Bring the griddle to 350°F and allow it to cycle twice. Take 9 temperatures across the surface of
the unit in grid form and record (the temperatures should be consistent to ±10°F):
LEFT MIDDLE RIGHT
5. Does the unit operate correctly for 15 minutes after unit has reached temperature?
(Circle Y/N) Y N
I accept this Start-up form as complete and accurate:
Signed: Restaurant Management
Print Name:
Date: / /

MP5017-2002 Accu-Steam Gas Griddle 12
3. INSTALLATION
TABLE TOP/STAND MODEL - GGF & PGF
TOOLS REQUIRED:
Spirit Level
Phillips Screw Driver
Small Blade Straight Screw Driver
Digital Volt Meter with ability to read DCuA-
for Flame Sense Measurement.
Manometer
Weighted Temperature Probe
Digital Temperature Meter
Installation must conform with local codes , or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation
Code, CSA B149.1, as applicable.
3.1 INSTALLATION NOTICE
Only qualified service technicians/electricians
should perform the installation to ensure that
all electrical, gas and safety requirements are
met and that all wiring, gas and plumbing
installations are performed in accordance with
all national, state and local codes.
The installation must conform with local codes,
or in the absence of local codes, with the
National Fuel Gas Code, ANSA/NFPA 54, or the
Natural Gas and Propane Installation Code,
CSA B149.1 as applicable.
The appliance and its individual shuto must
be disconnected from the gas supply piping
system during any pressure testing of that
system at test pressures in excess of 1/2
PSI(3.5kPA)
3.2 UNPACKING
This appliance was carefully inspected before
shipment from the factory. The transportation
company assumes full responsibility for safe
delivery to the customer until customer
acceptance of the package. Careful inspection
of the packaging and the appliance should
be completed before acceptance from the
transportation company.
3.3 GRIDDLE LIFTING
Griddles are heavy enough to require additional
manpower or powered assistance when
installing or moving the griddle.
When moving the equipment manually make
sure there are enough people for the task as the
equipment is heavy.
Make sure the equipment is not dropped
during moving. People doing the carrying could
be seriously injured and/or the equipment
damaged. The manufacturer does not accept
any responsibility for damage resulted from
such actions.
3.4 LOCATION AND PLACEMENT
The ACCU-STEAM™ gas appliance has been
designed to be placed on a commercial kitchen
counter-top, an AccuTemp griddle stand or
directly onto any flat, non combustible level
surface that will support the appliance weight.
The operating temperature ranges from 200°-
400°F (93°- 204°C). Since these temperatures
can also be found on surfaces around the
perimeter of this commercial appliance, care
should be given not to install next to or against,
objects or surfaces with a low melting or flash
point.

MP5017-2002 Accu-Steam Gas Griddle 13
3.5 CLEARANCES
Level left to right Level
front to
back
Griddle cooking surface
Fig 3.A
3.6 LEVELING
The appliance must be installed in a level
condition. An out-of-level condition may cause
uneven temperatures and in a severe out of level
condition damage to the appliance can occur.
Use a spirit level resting on the appliance cooking
surface to ensure it is level front-to-back and
left-to-right.
3.7 TABLE TOP
Install the (4) rubber foot tips provided with your
appliance onto the four foot adjusters of each of
the commercial appliance legs. This will keep the
griddle from sliding on the counter-top under
normal use. Once the rubber foot tips have been
installed, adjust the four foot adjusters up or
down as needed to level the griddle side to side
and front to back.
THE UNIT SHOULD NOT BE FLUSH MOUNTED
UNDER ANY CIRCUMSTANCES.
Location Combustible
Construction
Non-Combustible
Construction
Back 2 Inches 0 inches
Right Side 1 Inch 0 inches
Left Side 1 inch 0 inches
Above
Flue
No combustible
materials above
flue
6 inches
SUITABLE FOR ALL INSTALLATION ON COMBUSTIBLE
FLOORS.
3.8 STAND INSTALLATION
Improper installation, adjustment,
alteration, maintenance or service can
cause death or injury or property damage.
Read the installation instructions completely
before installing, maintaining or servicing this
accessory.
Use of any replacement parts other than
those supplied by AccuTemp Products may
cause bodily injury, damage to property, and
damage to the equipment. Use of non OEM
parts will void all active warranties.
Do not touch this accessory while running
as the outside will be hot and can cause a burn
injury. Always wait until the accessory is cool
before servicing.
Griddles that mount to the this accessory
are heavy enough to require additional people
or powered assistance when installing. Failure to
do so can cause injury or death.
Operation of this accessory in an out of
level condition could cause poor performance of
the griddle that is mounted to it.
TOOLS REQUIRED:
Lifting device that is rated for lifting a
minimum of 500 pounds to a minimum
height of 26 inches
7/16” combination wrench
Inch pound torque wrench and 7/16” socket
1” Open end wrench or Adjustable wrench
Level

MP5017-2002 Accu-Steam Gas Griddle 14
1. Carefully remove the packing material of
the stand.
2. Locate the stand in an area where there is
room to work around If the stand model
has casters lock the front casters to the on
position
(Fig 3.B).
Fig 3.B
3. Using the lifting device make sure that
the plate or forks extend the width of the
griddle bottom to avoid damaging the
griddle (Fig 3.C).
Fig 3.C
4. Raise the lifting device enough to gain
access to the four shipping legs (Fig 3.D).
Fig 3.D
5. Remove the two fasteners that attach each
of the four legs to the griddle and retain the
fasteners for later use (Fig 3.E).
Fig 3.E
6. Raise the lifting device so that the griddle
clears the mounting tabs of the stand (Fig
3.F). Align the holes in the four mounting
tabs of the stand to the threaded holes of
the griddle.
Fig 3.F
7. Locate the eight fasteners and lock washers
removed in step 6. Place a split lockwasher
on each bolt and push through the hole in
the mounting tab (2 holes per mounting
tab) and hand thread each into the griddle’s
threaded holes. Verify that the fasteners are
not cross threaded (Fig 3.G).
Fig 3.G

MP5017-2002 Accu-Steam Gas Griddle 15
8. Tighten each fastener to 75 inch pounds
(Fig 3.H).
Fig 3.H
9. Stands with adjustable feet: Level the
griddle using the adjustable feet from front
to back and side to side by using a 1” open
end wrench or adjustable wrench and turn
each foot clockwise to raise and counter
clockwise to lower (Fig 3.I).
Fig 3.I
Stands with casters:
If the stand is fitted with casters they can not
be adjusted and the floor must be level.
This accessory carries a one year parts
only warranty for manufacturing defects.

MP5017-2002 Accu-Steam Gas Griddle 16
When this appliance is installed with
casters it must be installed with the casters
supplied. A connector complying with
either ANSI Z21.69 - CSA 6.9. It must also
be installed with restraining means to the
connector as specified in the appliance
manufacturer’s instructions.
3.9 ELECTRICAL CONNECTIONS
3.9.1 ELECTRICAL SUPPLY
The ACCU-STEAM™ griddle has been designed,
manufactured and tested to meet or exceed
the demanding standards of safety set forth by
ANSI Z83.11. To to ensure that this high level
of safety is maintained in your installation, it is
important that you read and understand the
following information before attempting to
plug in your griddle.
3.8.2 ELECTRICAL REQUIREMENTS
Electrical requirements are listed on the
data plate located on the front right of the
control panel. All standard AccuTemp griddles
are supplied with a 6ft (1.83m) cord and
the appropriate UL listed plug that must be
connected to a 15 Amp (120Vac) or a 20 Amp
(208-240Vac) depending on the rating listed
on the data plate. Make sure that the voltage
at your supply receptacle is within ± 10 % of
the voltage listed on the griddle data plate.
Connection to any other voltage may cause
damage to components in the commercial
appliance. The appliance plug must be used
with the appropriate receptacle.
Direct wiring will void the warranty.
This commercial appliance must
be properly grounded in accordance of
all current National, state and local codes.
Never remove the ground prong of the plug.
3.9.3 GROUNDING INSTRUCTIONS
Grounding provides a path for electric current
to reduce the risk of shock. This product
is equipped with a power cord having a
grounding conductor and a grounding plug.
The plug must be plugged into a grounded
receptacle that is installed and grounded
in accordance with local codes, or in the
absence of local codes, with the National
Electric Code, NFPA 70, or the Canadian
Electrical Code, CSA22.2, as applicable.
Under no circumstances shall the grounding
or prong of the plug be cut o or bent to fit
a receptacle other than the one supplied. Do
not use any adapters to fit the receptacle.

MP5017-2002 Accu-Steam Gas Griddle 17
3.10 GAS CONNECTION
The griddle has a 90° male 1/2”
connection installed (Fig 3.L).
The gas supply pressures for the internal
regulator must be verified with a calibrated
manometer while the appliance is operating in
maximum load condition.
A 1/8” NPT tap is provided in the front of
the internal regulator to measure the burner
STATIC pressure, see FIGURE
Use a pipe joint compound or sealant designed
for the use with liquefied petroleum gas when
replacing the 1/8” NPT tap.
Flexible residential appliance connection
hoses are not suitable for this appliance and
will void any warranty.
Do not use an excessive amount of sealant
in order to prevent potential obstruction of the
gas control valve.
3.10.1 GAS PRESSURE ADJUSTMENT
INSTRUCTIONS
1. Ensure unit is connected to gas supply.
2. Turn gas o at supply.
3. Remove 1/8” NPT plug from dual solenoid
control valve.
4. Use a 1/8” NPT tap to connect a
manometer to the control valve. Ensure
manometer is set to read inches water
column (Fig 3.J & 3.K).
5. Turn gas and power supply on and turn unit
on.
6. When unit powers on, the pilot valve will
open and the STATIC pressure will be
present.
7. Once unit attempts ignition, the main valve
will open and the DYNAMIC pressure will
register on the manometer.
8. The DYNAMIC pressure must be set to 5
Inch Water Column (NG) or 10 inch WC
(Propane).
9. To adjust the pressure, remove the dust cap
on the regulator as seen in Fig 3.J & 3.K.
10. Adjustment screw can be turned using a
slot head screwdriver. Adjust while burner
is on.
Fig 3.L
Use a 1/8” NPT Barbed Pressure Tap
to connect a manometer and verify
pressure setting.
Gas pressure adjustment
screw
Fig 3.J - 2018 and older,
valve design
Fig 3.K - New Valve design as
of 2019

MP5017-2002 Accu-Steam Gas Griddle 18
3.10.2 FLAME SENSE RECTIFICATION
The Accu-Steam Gas Griddle utilizes a flame
sensing circuit to determine if the system has
proper combustion. When the system is turned
on, gas is sent to the burner and an electronic
ignition tries to ignite the burner. The ignition
module then checks to see if flame is
established in the burner.
If the flame sense feedback is within the proper
range the system will stay on until the control
board ceases the call for heat.
The ignition module continues to monitor the
voltage and as long as its within the proper
range the burner will stay on. If the flame sense
reading falls below the threshold of 0.38 DCµA
(microamperes) the griddle will go into lock
out and will stop heating. The external signal
for a lock-out is a 4 second flash on the FAULT
light.
1. The flame sense should be monitored and
recorded as part of the install.
2. To test for flame sense, Disconnect the
orange wire from the flame sense.
3. Connect the probes of an multimeter
capable of reading DCµA (DC micro-
amperes) to the flame sensor and orange
wire.
4. Run the unit and monitor the reading.
5. If the gas pressure is set correctly for the
gas type the reading should be 4 to 6
DCµA.
3.10.3 IGNITION TROUBLESHOOTING
Should the unit trigger an ignition lockout
during installation and testing, verify the
following
1. Verify the flame sense is above 0.38 DCµA.
a. If the reading is zero, ensure the flame
sense is not grounded.
b. If the reading fluctuates, check for drafts
that could be causing an unstable flame or
loose venturi connections to the burners
c. Ensure the flame sense is properly placed to
be engulfed by flame.
2. Double check the gas hose connection and
verify pressure.
a. Ensure the dynamic pressure is set to 5
Inches Water Column.
b. Test the unit when the supply is under
maximum load, ensure the static and
dynamic pressures do not fluctuate.
c. If an external regulator is connected to the
gas line, ensure its breathing vent is clear.
3. Confirm the ignition and ground probes are
correctly spaced.
a. The probes should have a gap of 0.125
±.020.

MP5017-2002 Accu-Steam Gas Griddle 19
4. OPERATION
RISKS RESULTING FROM CONTACT WITH
VERY HOT OBJECT:
HOT
Hot areas may form during the cooking
process, especially on the cookware, grills
and the inner side of the door. Use protective
gloves whenever handling hot objects.
During the cooking process, do not handle
cookware containing liquids or liquid
foodstus located above eye level. Danger of
burns.
Be sure all operators read, understand
and follow the information contained in this
manual including caution warnings, operating
instructions and safety instructions.
Never use wet or damp gloves as moisture
can conduct heat quickly.
Keep the floor in front of the equipment
clean and dry. If spills occur, clean immediately
to avoid potential injuries.
Do not use abrasive (or steel) materials,
such as wire brushes, metal scouring pads to
clean the griddle surface
4.1 OPERATION INTRODUCTION
The ACCU-STEAM G2™ griddle is constructed
and uses technology like no other griddle in
the world. The stainless steel cooking surface
is heated by steam. The griddle steam chamber
requires no additional liquid or maintenance.
A temperature sensor to sense temperature
and an over-temperature safety shutdown
system are part of the griddle assembly.
At temperatures below 212°F (100°C), the
chamber is actually in a vacuum, similar to
that of a canning jar. At temperatures above
212°F (100°C), the chamber operates under
pressure. The temperature sensor senses the
temperature of the steam and reports this
data to the temperature control electronics,
which energizes the heating system. This
system maintains the griddle cooking surface
temperatures to within ± 5°F (2.7°C) over the
entire cooking surface and provides a near
instant temperature recovery, even in the same
spot on the griddle, when turning food in
place.
Fig 4.A
Other manuals for Accu-Steam G2 Series
1
This manual suits for next models
12
Table of contents
Other AccuTemp Griddle manuals
Popular Griddle manuals by other brands

Southbend
Southbend Platinum Series Installation & operation manual

Avantco
Avantco EG24 user manual

Elite
Elite EGL-3450GD Instruction manual & recipes

Camplux
Camplux FMGG303B Instructions for installation and use

ASBER
ASBER AEMG-12 Manual instructions

Vulcan-Hart
Vulcan-Hart VCRG24-M Installation & operation manual