AccuTemp EGD Series S/N 7547 Operating instructions

AccuTemp Products, Inc. · 8415 North Clinton Park · Fort Wayne, IN 46825 ·800 210-5907 · accutemp.net
MP5004-1202
ELECTRIC GRIDDLE
INSTALLATION & OWNERS MANUAL
Serial Number:
Model:
Install Date:

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 1
TABLE OF CONTENTS
Instructions for Warranty Registration 2
Startup Form 3
Document History 4-5
Safety Warnings Denition 6
Safety Symbols Deniton 7
Specication Model EGF 8-9
Specication Model EGD 10
Introduction 11
Installation Model EGF 12-14
Installation Model EGD 15-21
Operation 22-23
Cleaning 24-26
Service and Troubleshooting 27-29
Parts - Commercial 30-34
Parts-Military 35-40
Model EGF Schematics 41-45
Model EGD Schematics 46-48
Warranty 49
This manual is for AccuSteam Griddles Starting with:
Model EGD Series S/N 7547
Model EGF Series S/N 7642

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 2
Before installing this appliance complete the following items:
Fill in the warranty registration card that was enclosed in the documentation packet that came with the1.
appliance.
Complete the startup checklist on page 2 of this manual.2.
Mail, fax or email the warranty registration card and startup form to AccuTemp™.3.
If you have any questions please contact our technical service group. They are available 7 days a week from
7:00 am to 7:00 pm EST.
800 480-0415 Toll Free
260 469-3040 Ofce
260 469-3045 Fax
[email protected] email
www.accutemp.net web site

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 3
"
6+):165
,,8-99
1:?
":):-
'17
065-;4*-8
4)13
6,-3
"-81)3
)4-6."-8<1+-/-5+?
#-+051+1)5
-)9;8-,";773?$63:)/-0-+265-
$ $ $ $
0)915/0-+265-
"15/3- 0)9- #08-- 0)9-
";773?+68,19+655-+:-,:67867-8/86;5,
&-9 6
$-81.?)+:;)39;8.)+-:-47-8):;8-):)
:0-8469:):9-::15/6.
6#;9-15.-88-,:0-8464-:-89
$-81.1-,(((((((((
644-5:9
)++-7::019+0-+26..319:)9+6473-:-)5,)++;8):-
!-9:);8)5:)5)/-8
):-
6:-":)8:;7.6844;9:*-.133-,6;:+6473-:-)5,+688-+:3?:0-5-1:0-8.)>-,684)13-,:6:0-
++;#-47#-+051+)3"-8<1+--7)8:4-5:*-.68-7)?4-5:19199;-,
++;#-47 86,;+:95+
::5#-+051+)3"-8<1+--7:
68:0315:65 )828
68:%)?5-
065-)>
"-8<1+-6;89,)?9)=--2)4 @ 74

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 4
DOCUMENT HISTORY
Current revision: – Prior revision: None
Date: 8/4/05 Date: None
Change
Initial release.
_______________________________________________________________________
Current revision: A Prior revision: –
Date: 8/16/05 Date: 8/4/05
Change
Added pages 26, 28 – 30, and 34 – 36; Renumbered pages as necessary.
_______________________________________________________________________
Current revision: B Prior revision: A
Date: 10/7/05 Date: 8/16/05
Page Change
Added pages ii and 24 – 27; Modied pages 4 – 8 and 19 – 23; Renumbered pages as necessary.
_______________________________________________________________________
Current revision: C Prior revision: B
Date: 10/12/05 Date: 10/7/05
Page Change
Added page iii; Modied pages iv, 19 – 27; Renumbered page iv.
_______________________________________________________________________
Current revision: D Prior revision: C
Date: 11/10/05 Date: 10/12/05
Page Change
Deleted pages ii, iii, and 25; Added pages 18, 33 and 34; Modied pages 13, 14, 25 – 32, and 35 –
40; Rearranged sections and pages for clarity; Renumbered pages as necessary.
_______________________________________________________________________

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 5
DOCUMENT HISTORY (cont.)
Current revision: E Prior revision: D
Date: 12/29/05 Date: 11/10/05
Page Change
Added page ii; Modied pages 18, 19, 22 – 24, 33, and 34.
_______________________________________________________________________
Current revision: MP5004-0811 Prior revision: D
Date: 12/29/05 Date: 11/10/05
Page Change
Added page ii; Modied pages 18, 19, 22 – 24, 33, and 34.
Current revision: MP5004-1412 Prior revision: MP5004-0811
Date: 02/14/2012 Date: 11/10/05
Page Change
Numeric Page Numbers all pages
All Pages Modied for Engineering Changes

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 6
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or
serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, could result in minor or
moderate injury.
NOTE
Advises reader of information or instructions vital to the operation or maintenance of the
equipment.
SAFETY WARNINGS
SYMBOL DEFINITIONS
Symbols are used to attract your attention to possible dangers. They are only effective
if the operator uses proper accident prevention measures. Some of the symbols are
boxed text, while other maybe just picture icons. Please give this information the
respect they deserve for safe operation.
WARNING TEXT BOXES
Below are denitions of the warning text boxes:
DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or
serious injury.

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 7
SAFETY WARNINGS (cont.)
SYMBOL ICONS
Below are denitions of symbol icons used in this manual:
ALERT – Noties the reader of an important message/warning, usually a safety related
message.
INFORMATION – Noties the reader of important information that may or may not be
safety-related.
EARTH GROUND
DANGEROUS VOLTAGE
CAUTION, HOT SURFACE

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 8
RIGHT SIDE VIEW
TOP VIEW
(2)
Power Cord
Provided
Grease Trough
(A)
4 1/2"
[114]
Control Panel
Grease Pan
(C)
(Cooking Depth)
17 5/8"
[448]
12 3/4" [323]
(Cooking Height)
(B)
(Cooking Width)
Feet Standard
(D)
Unit Depth
22 3/4" [578]
Bullet Feet Footprint
(E) 2 5/8”
[66]
Griddle Width
24”
36”
48”
Dim leg-to-leg
20”
32”
44”
RIGHT SIDE VIEW
EGF FLUSH MOUNT SERIES
8 1/4" [209]
(Cooking Height)
12 9/16"
[319]
--
AccuTemp Products, Inc.
.ORTH#LINTON0ARKs&ORT7AYNE).sss&AXsACCUTEMPNET
Accu-Steam Griddle Specifications (replace **** with voltage & phase, i.e. 2083)
Model # EGF****A2400-T1 EGF****B2400-T1 EGF****A3600-T1 EGF****B3600-T1 EGF****A4800-T1 EGF****B4800-T1
KW Input 9.6 kW 9.6 kW 14.25 kW 14.25 kW 14.25 kW 14.25 kW
208/3 Amp Load 26.68 26.68 39.56 39.56 39.56 39.56
240/1 Amp Load 40 40 n/a n/a n/a n/a
240/3 Amp Load 39.58 39.58 34.28 34.28 34.28 34.28
440/3 Amp Load 17.1 17.1 25 25 25 25
480/3 Amp Load 15.41 15.41 22.87 22.87 22.87 22.87
Unit Width (A) 24.25 [616] 24.25 [616] 36.25 [921] 36.25 [921] 48.25 [1226] 48.25 [1226]
Unit Depth (D) 33.125 [841] 28.125 [714] 33.125 [841] 28.125 [714] 33.125 [841] 28.125 [714]
Cooking Surface Width (B) 23.875 [606] 23.875 [606] 35.875 [911] 35.875 [911] 47.875 [1216] 47.875 [1216]
Cooking Surface Depth (C) 28.375 [721] 23.375 [594] 28.375 [721] 23.375 [594] 28.375 [721] 23.375 [594]
Depth to Front Leg (E) 3.188 [81] 5.688 [144] 3.188 [81] 5.688 [144] 3.188 [81] 5.688 [144]
Effective Cooking Area 677 sq. in. 558 sq. in. 1017 sq. in. 838 sq. in. 1358 sq. in. 1119 sq. in.
Grease Pan Capacity 1.5 gal. 1.5 gal. 2 gal. 2 gal. 2 gal. 2 gal.
NEMA Plug (208/240) 15-50P 15-50P 15-50P 15-50P 15-50P 15-50P
NEMA Plug (440/480) L16-20P L16-20P L16-30P L16-30P L16-30P L16-30P
A
CCU
-S
TEAM
™ G
RIDDLE
EG S
ERIES
%LECTRIC3TEAM(EATED
4ABLETOP'RIDDLE
Notes:
1.) Dimensions in brackets [ ] are metric.
2.) 5’ power cord wtih plug provided.

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 9
AccuTemp Products, Inc.
.ORTH#LINTON0ARKs&ORT7AYNE).sss&AXsACCUTEMPNET
Accu-Steam Griddle Specifications (replace **** with voltage & phase, i.e. 2083)
Model # EGF****A2400-S2 EGF****B2400-S2 EGF****A3600-S2 EGF****B3600-S2 EGF****A4800-S2 EGF****B4800-S2
KW Input 9.6 kW 9.6 kW 14.25 kW 14.25 kW 14.25 kW 14.25 kW
208/3 Amp Load 26.68 26.68 39.56 39.56 39.56 39.56
240/1 Amp Load 40 40 n/a n/a n/a n/a
240/3 Amp Load 39.58 39.58 34.28 34.28 34.28 34.28
440/3 Amp Load 17.5 17.5 25 25 25 25
480/3 Amp Load 15.41 15.41 22.87 22.87 22.87 22.87
Unit Width (A) 24.25 [616] 24.25 [616] 36.25 [921] 36.25 [921] 48.25 [1226] 48.25 [1226]
Unit Depth (D) 33.125 [841] 28.125 [714] 33.125 [841] 28.125 [714] 33.125 [841] 28.125 [714]
Cooking Surface Width (B) 23.875 [606] 23.875 [606] 35.875 [911] 35.875 [911] 47.875 [1216] 47.875 [1216]
Cooking Surface Depth (C) 28.375 [721] 23.375 [594] 28.375 [721] 23.375 [594] 28.375 [721] 23.375 [594]
Depth to Front Leg (E) 3.188 [81] 5.688 [144] 3.188 [81] 5.688 [144] 3.188 [81] 5.688 [144]
Effective Cooking Area 677 sq. in. 558 sq. in. 1017 sq. in. 838 sq. in. 1358 sq. in. 1119 sq. in.
Grease Pan Capacity 1.5 gal. 1.5 gal. 2 gal. 2 gal. 2 gal. 2 gal.
NEMA Plug (208/240) 15-50P 15-50P 15-50P 15-50P 15-50P 15-50P
NEMA Plug (440/480) L16-20P L16-20P L16-30P L16-30P L16-30P L16-30P
A
CCU
-S
TEAM
™ G
RIDDLE
EG S
ERIES
%LECTRIC3TEAM(EATED
3TAND-OUNTED'RIDDLE
Notes:
1.) Dimensions in brackets [ ] are metric.
2.) 5’ power cord wtih plug provided.
(D)
Unit Depth
(2)
Power Cord
Provided
Grease Chute
(A)
(B)
(Cooking Width)
(C)
(Cooking Surface Depth)
40 7/16"
[1028]
Control Panel
Grease Pan
27 7/8"
[709] 36 1/8"
[918]
(Cooking Height)
Stand With
Casters
Griddle Width
24”
36”
48”
Dim leg-to-leg
20”
32”
44” 22 3/4”[578]
Leg-to-Leg Footprint
--

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 10
35.50"
[902mm]
1.625 - 4.125"
[41 - 105mm]
6.50"
[165mm]
(A)
(B)
Cooking Surface Width
(C)
Cooking Surface
Depth
29.50"
[749mm]
8.87 - 11.0"
[225 - 279mm]
See Note 2
1.31"
[33]mm
1.5" [38mm]
Depth To Cooking Surface
.73 - 2.63"
[9 - 67mm]
See Note 2
0" - 1.0"
[0 - 25mm]
MM5207-0912
AccuTemp Products, Inc.
.ORTH#LINTON0ARKs&ORT7AYNE).sss&AXsACCUTEMPNET
Accu-Steam Drop-In Griddle Specifications
(replace **** with voltage & phase, i.e. 2083)
Model #
EGD****B3600-00 EGD****B4800-00
KW Input 14.25 kW 14.25 kW
208/3 Amp Load 39.56 39.56
240/3 Amp Load 34.28 34.28
440/3 Amp Load 21 21
480/3 Amp Load 17.14 17.14
Unit Width (A) 36.5 [927] 49 [1245]
Unit Depth (D) 29.5 [749] 29.5 [749]
Cooking Surface Width (B) 34 [864] 46.5 [1181]
Cooking Surface Depth (C) 23.5 [597] 23.5 [597]
Effective Cooking Area 799 sq in
[20295 sq mm]
1093 sq in
[27762 sq mm]
Rough Opening Griddle 35.5 x 28.5
[902 x 724]
47.75 x 28.5
[1213 x 724]
Rough Opening Control
Panel
33.75 x 4.875
[857 x 124]
33.75 x 4.875
[857 x 124]
Grease Pan Capacity 1.5 gal. 1.5 gal.
NEMA Plug (208/240) 15-50P 15-50P
NEMA Plug (440/480) L16-30P L16-30P
A
CCU
-S
TEAM
™ G
RIDDLE
EG S
ERIES
%LECTRIC3TEAM(EATED
Drop-In Griddle
Notes:
1.) Dimensions in brackets [ ] are metric.
2.) 5’ power cord wtih plug provided.

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 11
THEORY OF OPERATION
INTRODUCTION
The ACCU-STEAM™ griddle is constructed and uses technology like no other griddle in the
world. The diagram below is a cross-sectional view of the griddle. The griddle cooking surface
is the top of a chamber in which we have produced a unique environment. Welded stainless steel
reinforcement studs connect the chamber top to the chamber bottom. The perimeter joints are
all robotically welded to produce a vessel that is airtight, which is veried using a helium mass
spectrometer. The chamber is lled half full with distilled water. The remaining air is removed
and the chamber is welded shut. At this point, the chamber becomes a hermetically sealed vessel,
never to be opened again. The griddle steam chamber requires no water or maintenance. A
thermowell for a temperature sensor to sense temperature and a thermowell for the overtemp
safety shutdown system are also welded into the griddle steam chamber.
At temperatures below 212°F (100°C), the chamber is actually in a vacuum, similar to that of a
canning jar. At temperatures above 212°F (100°C), the chamber operates under pressure. Located
between the water and the bottom of the cooking surface is the best heat transfer medium –
steam, the most effective way to transfer heat. The temperature sensor senses the temperature
of the steam and reports this data to the thermostat, which energizes the heating elements. This
system maintains the griddle cooking surface temperatures to within ± 5°F (2.7°C) over the
entire cooking surface and provides a near instant temperature recovery, even in the same spot on
the griddle, when turning food in place.

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 12
ELECTRIC
TABLE TOP & STAND
MODEL EGF SERIES
INSTALLATION INSTRUCTIONS

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 13
INSTALLATION
TABLE TOP/STAND MODEL - EGF SERIES
LOCATION AND PLACEMENT
The AccuTemp ACCU-STEAM™ electric griddle has been designed to be placed on a
commercial kitchen counter-top, an AccuTemp griddle stand or directly onto any at, level
surface.
The operating temperature ranges from 200°- 400°F (93°- 204°C). Since these temperatures can
also be found on surfaces around the perimeter of the griddle, care should be given not to install
griddle next to or against, objects or surfaces with a low melting or ash point.
LEVELING
The griddle must be installed in a level condition. An out-of-level condition may cause uneven
temperatures and in server out of level condition damage to the griddle that may not be covered
by warranty. Use a spirit level resting on the griddle surface to ensure it is level front-to-back and
left-to-right.
Table Top
Install the (4) rubber foot tips provided with your griddle onto the four foot adjusters of each of
the griddle legs. This will keep the griddle from sliding on the counter-top under normal use.
Once the rubber foot tips have been installed, adjust the four foot adjusters up or down as needed
to level the griddle.
ACCUTEMP STAND
If on an AccuTemp™ stand with casters, ensure that the oor surface is level and place the
two locking casters to the “on” position and follow the leveling instructions to verify the the
appliance is level.
IN-FIELD MODIFICATIONS
This griddle has a totally unique design and is constructed unlike any other griddle on the market
today. Any modication may permanently damage the griddle.
Only a qualied service or electrician should complete the installation to ensure that all
eletrical and safety requirements are met and that all wiring is installed as per all National,
State and Local electrical codes.
WARNING
This appliance is heavy. For safe handling, the installer should obtain help as needed or
employ appropriate material handling equipment to remove the appliance from the skid
and move into the nal destination.
WARNING
Any in eld modications made without written authorization from AccuTemp™ will void
all warranties
NOTE

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 14
NEMA 6-50R NEMA 15-50R NEMA L16-30R
INSTALLATION
This appliance must be properly grounded, In accordance with all the National, State and
local electrical codes.
WARNING
ELECTRICAL SUPPLY
The ACCU-STEAM™ griddle has been designed, manufactured and tested to meet or exceed
the demanding standards of safety set forth by Underwriters Laboratories, Inc. To ensure that
this high level of safety is maintained in your installation, it is important that you read and
understand the following information before attempting to plug in your griddle.
ELECTRICAL REQUIREMENTS
Electrical requirements are listed on the data plate located on the right side of the unit, near the
front. All standard AccuTemp griddles are supplied with a 6ft (1.83m) cord and the appropriate
UL listed plug. Please note, that the plug is rated for 250VAC. This plug is commonly used for
both 208VAC and 240VAC installations. Make sure that the voltage at your supply receptacle
is within ± 10 % of the voltage listed on the griddle data plate. Connection to any other voltage
may cause damage to components in the griddle and damage of this type is not covered under
warranty.
GROUNDING INSTRUCTIONS
Grounding provides a path for electric current to reduce the risk of shock. This product is
equipped with a power cord having a grounding conductor and a grounding plug.
ELECTRICAL CONNECTIONS (MODEL EGF ONLY)
The receptacle requirements vary between models.
If you have purchased a 240 V single-phase model, you will need a NEMA 6-50R
receptacle. If you have purchased 208/240V a three-phase model, you will need a NEMA
15-50R receptacle and if you purchased a 440V/480V three-phase model you will need a
NEMA l16-30R receptacle
These receptacles are congured as shown below.

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 15
MODEL EGD
INSTALLATION INSTRUCTIONS
This appliance is heavy. For safe handling, the installer should obtain help as needed or
employ appropriate material handling equipment to remove the appliance from the skid
and move into the nal destination.
WARNING
Any in eld modications made without written authorization from AccuTemp™ will void
all warranties
NOTE
The appliance must be installed in accordance with the following building codes:
USA: National Electrical Code, ANSI/NFPA-70, state and local codes, International
Plumbing Codes 2003, ICC or Uniform Plumbling Code 2003, IAMPO. Canada Electric
Code, CSA C22.2 and state and local codes.
WARNING

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 16
Fig. 1
Introduction
It is highly recommended that a survey of the kitchen site be conducted to determine the
requirements for the installation. Electrical supply, counter space as well as counter arrangement
are critical to the choice of Drop-In-Griddle options. The Drop-In-Griddle is available in many
options to accommodate size, control panel arrangements and supply voltage. The model data
label indicating the model number, phase, voltage, current, wattage and UL information is
located on the bottom cover of the unit.
Counter designs that have an “L” arrangement such that the shortest part of the “L” is to the left
may require a “Right Hand Control Panel” option. A counter design that has an “L” arrangement
such that the shortest part of the “L” is to the right may require a “Left Hand Control Panel”
option. See Figure 1 for views of these congurations.
INSTALLATION
MODEL EGD
This product is to be installed in stainless or non-combustible countertops only.
CAUTION
Installation must allow inspection and serviceability to the undeside of the appliance
NOTE

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 17
INSTALLATION (cont.)
MODEL EGD
ELECTRICAL SUPPLY
The ACCU-STEAM griddle has been designed, manufactured and tested to meet or
exceed the demanding standards of safety set forth by Underwriters Laboratories, Inc.
To ensure that this high level of safety is maintained in your installation, it is important
that you read and understand the following information before attempting install your
griddle.
ELECTRICAL REQUIREMENTS
Electrical requirements are listed on the data plate located on the Bottom of the Control
Box, near the front. The EGD Series griddles are supplied with a 5ft (1.52m) cord. Make
sure that the voltage at your supply is within ± 10 % of the voltage listed on the griddle
data plate. Connection to any other voltage may cause damage to components in the
griddle and damage of this type is not covered under warranty.
This appliance must be properly grounded, in accordance with all National, State and local
electrical codes.
WARNING
GROUNDING INSTRUCTIONS
Grounding provides a path for electric current to reduce the risk of shock. This product
is equipped with a power cord having a grounding conductor.

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 18
GETTING STARTED
Please read and comprehend all instructions and manuals provided with each Drop-
In-Griddle. Read and understand all safety warnings and operator instructions for all
powered tools required to complete the installation of the Drop-In-Griddle. Disconnect
all power from house supply connection boxes at the appropriate fuse panel
and label the breakers “In service”.
This is to warn others that work is in process, preventing accidental electrocution.
TYPICAL TOOLS AND SUPPLIES REQUIREMENTS
• Putty knife
• Grease solvents
• Clean sponges or rags
• Latex gloves
• Caulking gun
• Approximately 3oz. NSF-approved aluminized silicone sealant
• Tape measure
• Carpenters square
• #2 Phillips screw driver
• Channel lock pliers
• ½ inch box/open wrench
• 3/8 inch nut driver
• 3/8 inch electric or cordless drill
• #25 drill bit
• 3/8 inch drill bit
• Saber saw with metal cutting blades
• Permanent marking pen, preferably a “Sharpie” ne point.
• 4 inch grinder. (If replacing an existing competitors griddle, it is recommend to use
a 4 inch grinder to clean off any welds, welded on brackets or framing attached to
the counter top.)
LIST OF PACKAGING REQUIREMENTS:
• (1) Owners/Installation Manual
• (1) Griddle Module
• (1) Control Panel Module
• (1) Cable Assembly
• (4) Grease Spout Extension
• (1) Grease Trough Assembly
• (1) Grease Tray Assembly
• (1) Grease Trough Hanger Bracket
• (1) Grease Trough Hanger
• (8) 10-24 x 3/8 inch Self-Tapping Truss Head Screw
• (6) 10-24 x ½ inch Phillips Round Head Machine Screw
• (2) 5/16-18 X ¾ inch Carriage Head Bolt
• (2) 5/16 inch Lock Washer
• (2) 5/16-18 Hex Nut
• (8) 1/4-20 Nyloc Nut
• (4) Retainer Bracket
INSTALLATION (cont.)
MODEL EGD

Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 19
1. Inspect the griddle packaging to ensure there are no missing components.
2. Complete the appropriate power disconnection procedures for existing equipment
or local power junction boxes.
3. Clean surfaces with grease solvents and dry off with clean rags or sponges.
4. Determine the location and orientation for the griddle and control panel modules.
Mark the centerline on the countertop for the griddle module, using a Carpenter’s
square. See Figure 2 for the countertop and control panel layouts. Continue the
centerline to the control panel module mounting surface. Accurate centerline
alignment of the countertop and control panel modules is critical to ensure the
correct alignment of the grease trough assembly to the griddle module.
Fig. 2
INSTALLATION DROP-IN GRIDDLE (cont.)
MODEL EGD
This manual suits for next models
7
Table of contents
Other AccuTemp Griddle manuals
Popular Griddle manuals by other brands

Keating Of Chicago
Keating Of Chicago Teppanyaki Griddle manual

Presto
Presto 7039 instructions

CPG
CPG 351GTCPG15NL Conversion guide

Alice's Garden
Alice's Garden BBQCP40SS manual

Ultra Max
Ultra Max 724TA Installation and operation instructions

Fagor
Fagor Kore 700 Series Installation, Usage and Maintenance Instructions

Vulcan-Hart
Vulcan-Hart Vulcan 924RE Installation & operation manual

APW Wyott
APW Wyott GGT-18i Installation and operating instructions

INOX-bazis
INOX-bazis PLUS 600 Series Original operating instructions

Star
Star 515TGD-AP Installation and operation instructions

Lang
Lang 136SDI Installation and operation instructions

Cecilware