Acmeda SS38 User manual

SS38 SYSTEM
INSTALLATION MANUAL
July 2015

CONTENTS
July 2015
This manual is to be read in conjunction with the Product Specifications & Assembly manual
SECTION NO.
DESCRIPTION
PAGE NO.
SECTION 1 −ITEMS REQUIRED 1.1
SECTION 2 –INSTALL / UNINSTALL - USING LOW PROFILE CLIPS 2.1
PART A –PREPARING INSTALLATION SPACE 2.1
PART B –INSTALLATION 2.1
PART C –UN-INSTALLATION 2.4
SECTION 3 –INSTALL / UNINSTALL - USING SPRING LOADED CLIPS 3.1
PART A –INSTALLATION 3.1
PART B –UN-INSTALLATION 3.4
SECTION 4 –SLIM SPOOL CORD REPLACEMENT 4.1
SECTION 5 −TROUBLESHOOTING 5.1
DISCLAIMER
INTRODUCTION
This Installation manual has been produced by Acmeda to supply the necessary information for safe and correct installation of this system.
INSTALLERS RESPONSIBILITY
Before installing, please read & ensure you understand the safety information and installation instructions as defined in this installation manual.
If you do not fully understand these instructions, contact Acmeda for clarification before installing.
The Installer is responsible to ensure that all installation personnel have been adequately trained on the safe & correct installation and operation.
The Installer is responsible to ensure that a Job Safety Analysis or Safe Work Method Statement is completed prior to installation to identify hazards, to determine
appropriate risk control measures and to implement the control measures.
The Installer is responsible to ensure that supporting structures are sound and can adequately support the load.
The Installer is responsible to ensure that the devises used to anchor the product to the supporting structure are suitable for the application.
SAFETY INFORMATION
Ensure Job Safety Analysis/Safe Work Method Statement is completed and actions to reduce risks are implemented.
Ensure that electrical works are done only by a LICENSED ELECTRICIAN.
DO NOT modify any of the components of this system.
PERSONNEL REQUIREMENTS
Only suitably trained/qualified personnel should undertake installation.
DISCLAIMER
Acmeda has used reasonable care in preparing the information included in this document, but makes no representations or warranties as to the completeness or accuracy
of the information. Information is supplied upon the condition that the persons receiving the information will make their own determination as to its suitability for their
purposes prior to use. Acmeda assumes no liability whatsoever for any damages incurred by you resulting from errors in or omissions from the information included
herein. Acmeda reserves the right to make changes without further notice to any products to improve reliability, function or design.
COPYRIGHT
COPYRIGHT © ACMEDA 2015
All rights reserved. No part of this document may be reproduced or utilised in any means, by any means, electronic or mechanical including photocopying, recordings, or
by any information storage or retrieval system, without the express permission from Acmeda.

Page 1.1
SS38 SYSTEM Installation Manual | July 2015
© Copyright 2015 | All Rights Reserved Acmeda (International Group)
SECTION 1 −ITEMS REQUIRED
TOOLS REQUIRED
Drill
Drill Bits –[specify sizes required if detailed in assembly manual]
Screw Drivers
Measuring Tape
Pencil
BLIND ITEMS REQUIRED
Check you have all blind items;
1. Assembled SS38 Roman blind
2. Mounting clips and fixtures
ADDITIONAL ITEMS REQUIRED (NOT SUPPLIED)
To install the SS38 SYSTEM, the following non-stocked items are required:
Screws (appropriate for the material that the brackets will be fixed to)

Page 2.1
SS38 SYSTEM Installation Manual | July 2015
© Copyright 2015 | All Rights Reserved Acmeda (International Group)
SECTION 2 –INSTALL / UNINSTALL - USING LOW PROFILE CLIPS
PART A –PREPARING INSTALLATION SPACE
STEP 1 –DESCRIPTION
Check for any obstructions that may interfere with installation.
e.g. if there are any extra trimmings on the window frame that may interfere with the installation of SS38 system, ensure space is
prepared before installation.
PART B –INSTALLATION
STEP 1 –ATTACH MOUNTING CLIPS TO WALL/CEILING
TOP FIX
FACE FIX
STEP 2 –ENSURE STRAIGHT ALIGNMENT
Ensure mounting clips are in line.
TOP FIX
FACE FIX
STEP 3 –ADJUST IF REQUIRED
Slight adjustment is available (Top Fix 3mm, Face Fix 5.5mm)
TOP FIX FACE FIX

Page 2.2
SS38 SYSTEM Installation Manual | July 2015
© Copyright 2015 | All Rights Reserved Acmeda (International Group)
STEP 4 –INSTALLATION POSITIONING
To make installation of the blind easier, lift the blind to the raised position & temporarily take fabric off the head rail.
STEP 5 –ATTACH HEAD RAIL TO MOUNTING CLIPS
Mount the blind assembly onto the Mounting Clips.
TOP FIX
FACE FIX
*Top Fix shown as example. (also applies to Face Fix)

Page 2.3
SS38 SYSTEM Installation Manual | July 2015
© Copyright 2015 | All Rights Reserved Acmeda (International Group)
STEP 6 –ATTACH HEAD RAIL TO MOUNTING CLIPS (COMPLETE)
TOP FIX FACE FIX
STEP 7 –RE-ATTACH FABRIC

Page 2.4
SS38 SYSTEM Installation Manual | July 2015
© Copyright 2015 | All Rights Reserved Acmeda (International Group)
PART C –UN-INSTALLATION
STEP 1 –DISENGAGE ORDER
Disengage clips at each end first (1 & 3).
Disengage middle clip and remove blind (2).
OPTION 1 –TOUCH TAPE APPLICATION
OPTION 2 –SPLINE APPLICATION
Step 1. Remove fabric from head rail to access mounting clips.
If fabric is splined, reach in behind blind to disengage brackets.
Step 2. While bracket is flexing apply force to twist extrusion
off bracket.

Page 3.1
SS38 SYSTEM Installation Manual | July 2015
© Copyright 2015 | All Rights Reserved Acmeda (International Group)
SECTION 3 –INSTALL / UNINSTALL - USING SPRING LOADED CLIPS
PART A –INSTALLATION
STEP 1 –ATTACH MOUNTING CLIPS TO WALL/CEILING
TOP FIX
FACE FIX
STEP 2 –ENSURE STRAIGHT ALIGNMENT
Ensure mounting clips are in line.
TOP FIX
FACE FIX
STEP 3 –ADJUST IF REQUIRED
TOP FIX (NO ADJUSTMENT)
FACE FIX (SLIGHT 4MM ADJUSTMENT AVAILABLE)

Page 3.2
SS38 SYSTEM Installation Manual | July 2015
© Copyright 2015 | All Rights Reserved Acmeda (International Group)
STEP 4 –INSTALLATION POSITIONING
To make installation of the blind easier, lift the blind to the raised position & temporarily take fabric off the head rail.
STEP 5 –ATTACH HEAD RAIL TO MOUNTING CLIPS
Mount the blind assembly onto the Mounting Clips.
SAME FOR TOP OR FACE FIX
*Top Fix shown as example. (also applies to Face Fix)

Page 3.3
SS38 SYSTEM Installation Manual | July 2015
© Copyright 2015 | All Rights Reserved Acmeda (International Group)
STEP 6 –ATTACH HEAD RAIL TO MOUNTING CLIPS (COMPLETE)
TOP FIX FACE FIX
STEP 7 –RE-ATTACH FABRIC

Page 3.4
SS38 SYSTEM Installation Manual | July 2015
© Copyright 2015 | All Rights Reserved Acmeda (International Group)
PART B –UN-INSTALLATION
STEP 1 –REMOVE FABRIC FROM BLIND
Remove fabric from head rail to access mounting clips.
STEP 2 –DISENGAGE ORDER
Disengage clips at each end first (1 & 3).
Disengage middle clip and remove blind (2).
STEP 3 –DISENGAGE BRACKETS
Flex mounting clip with finger to disengage from head rail.

Page 4.1
SS38 SYSTEM Installation Manual | July 2015
© Copyright 2015 | All Rights Reserved Acmeda (International Group)
SECTION 4 –SLIM SPOOL CORD REPLACEMENT
STEP 1 –REMOVE DAMAGED CORD FROM GUIDE
If necessary, remove damaged cord from guide and pull from notch
NOTE: BEFORE INSTALLING NEW CORD, ENSURE THAT CORD NOTCH IS FACING UP
STEP 2 –ENSURE THAT EXISTING CORDS AND NOTCHES ARE ALIGNED

Page 4.2
SS38 SYSTEM Installation Manual | July 2015
© Copyright 2015 | All Rights Reserved Acmeda (International Group)
STEP 3 –TIE A KNOT IN END OF CORD, INSERT INTO NOTCH AND PULL
STEP 4 –RUN CORD UNDER GUIDE AND PULL UP
STEP 5 –ENSURE THAT THAT CORDS ARE IN ALIGNMENT

Page 5.1
SS38 SYSTEM Installation Manual | July 2015
© Copyright 2015 | All Rights Reserved Acmeda (International Group)
SECTION 5 −TROUBLESHOOTING
NO.
PROBLEM
CAUSE
SOLUTION
1
Uneven blind
Cord not running straight
down.
Make sure cord outlet of spool is aligned with cord
clips on the battens.
Cord in spool not aligned to
start with.
Make sure cords on every spool are aligned
horizontally to ensure they wind down evenly.
Cord knots are uneven.
Ensure the cord knots tied off at the bottom are even
lengths and sit level and tight against the last batten.
Cord has overlapped in spool
Check the cord is spooling evenly along when wound.
If the cord has overlapped itself bring the blind all the
way down then back up again to reset cord.
2
Cord loops seen below fabric
Cords are too long
Ensure the cord knots tied off at the bottom are even
lengths and sit level and tight against the last batten.
3
Noisy operation
Spool spacing is too great
Make sure you have enough spools across the length
of the blind. This will stop any possible sagging
between spools.
Spool not secure
Ensure all the spools are secured tightly to the head
rail
Rod deformed
Ensure the rod is straight and not deformed.
4
Broken Cord
1kg per spool exceeded
Add additional spools. To replace cord refer to
Section 4 - Slim spool cord replacement
Table of contents