2Model ACT20 Last updated: 26-09-2020
Introduction
The AcquaSaver Valve is a fully automatic mechanical rainwater/mains changeover
device designed for submersible pressure pump system for harvesting rainwater for
the toilet, laundry and household applications with automatic mains water backup.
Features
Patent design
Easy to install
Watermark Approved
2 year warranty
Does not require regular maintenance
No electrical consumption
No electrical components
Solid brass construction
Fully waterproof - Built to last
Built-in certified dual check valve for
backflow prevention
Watermark Approved right angle ball valves
Specifications
Max Mains Pressure 500 KPa recommended
Max Pump Pressure 600 KPa
Min Pump Pressure 300 KPa Recommended
Max Flow Rate 50 LPM
Max water temperature 40° C
Min Water Temperature 0° C*
Pump Inlet 25mm 1” BSP F
Mains Water Inlet 20mm 3/4” BSP
Outlet 20mm 3/4” BSP
Weight 2.5 Kg
*Ensure proper protection against freezing weather
Operation
The AcquaSaver valve will always prioritize the use
of rainwater over mains water when rainwater is
available and will automatically switch to mains
water in the event of the rainwater tank running low
or in an electrical failure.
When rainwater has been replenished, or power
has been restored to the pump, the AcquaSaver
valve will always automatically prioritize back to
rainwater.
The pump is only active when rainwater is being
drawn from the rainwater tank; it does not operate
when the AcquaSaver valve has switched to mains
water position.
The pump’s controller will start and stop the pump
when it detects a demand, for example; flushing a
toilet.
The operating mechanism of the AcquaSaver valve
is a unique patent design and works by hydraulic
water pressure created by the pump to close the
mains water inlet, which ensures an extremely
reliable mechanism using few moving parts and no
electronic components..
Maintenance
The AcquaSaver valve does not require
maintenance; however, there are things you can do
to ensure its most reliable operation:
– Cleaning your gutters
– Cleaning the inlet strainer on the rainwater tank
Installation &
Operating Instructions