AAPW40 43 (163) 5 (19) 3 5/16" (8mm)
AAPW160 172 (650) 15 (57) 9.5 1/2" (12.7mm)
AAPW250 291 (1,100) 25 (95) 16 1/2", 3/4" (12,7mm, 19mm)
AAPW400 370 (1,400) 40 (151) 24 1/2", 3/4" (12.7mm, 19mm)
AAPW550 529 (2,000) 55 (208) 33 1/2", 3/4" (12.7mm,19mm)
AAPW800 793 (3,000) 80 (303) 58 1/2", 3/4", 1" (12.7mm,19mm, 25mm)
AAPW1000 1110 (4,200) 100+ (378+) 92 1/2", 3/4", 1" (12.7mm,19mm, 25mm)
WARNING
• This pump is supplied with a grounding conductor and a grounding type aachment
plug. To reduce risk of electric shock, connect only to a properly grounded outlet.
• Do not remove the grounding pin from the plug.
• Do not connect to any voltage other than that shown on the pump.
• Do not pump ammable liquids.
• The naonal electric code requires that a grounded fault circuit interrupter (GFCI)
be used in the branch circuit supplying fountain pumps and other pond equipment.
See your electrical supplies dealer for this device.
• Do not use with water above 86°F (30°C).
• Do not allow the pump to freeze in winter, remove pump from fountains and ponds
and store in a frost-free area.
CAUTION:
Always disconnect from electrical outlet before handling the pump.
Do not let the pump run dry.
Do not li the pump by the power cord.
Do not pump heated liquids.
Do not operate in salt water.
PERFORMANCE
• A clogged or dirty intake screen will greatly reduce performance. If the pump is
used on a dirty surface, raise it slightly to reduce the amount of debris contacng
the intake. If less ow is desired, adjust the ow control knob on the front of the
pump or restrict the discharge ow.
• This pump can be used submersed or in-line. Note that when used in-line it should
be placed below the water level since it is not self priming. Never run this pump
dry. If inially the pump does not work, it may be “air locked”. To clear the air lock,
unplug the pump and rotate 180 degrees under water, repeat if necessary.
The included gray ng should be aached to the inlet side of the pump only when
operated in-line. The barbed gray and black ngs use a dierent sized thread and
rubber O-rings. The gray in-line ng aaches to the front of the pump and uses
the larger sized O-ring. The black ngs aach to the top of the pump and use the
smaller sized O-ring. Please use only as intended (see chart for reference).
Product
Item Code
Rated
GPH (LPH)
Recommended Size
gallons (litres,litros)
Was Fing Sizes Included
inches (milimeters)
0
2
4
6
8
10
12
0 200 400 600 800 1000 1200
HEAD (FT) HEIGHT
GALLONS PER HOUR (LPH) VOLUME
AAPW1000
800
550
160
40
400