ActronAir LM7-D User manual

TM
AIR CONDITIONER
ULTIMA ZONE CONTROL
Master Controller
LM7-D
Ultima Zone Controller
LM-ZC
®
Copyright © 2013
All rights reserve. No part or contents of this book maybe reproduced or transmitted in any
form or by any means without the written permission of Actron Engineering Pty. Ltd.
Operating Instructions
Please Read This Manual
Congratulations on your purchase of an
ActronAir air conditioning system. This unit
has been designed and manufactured with
the highest quality standard in mind.
Please read this manual carefully and keep it
for future reference.

2
GENERAL INFORMATION
YOUR ACTRONAIR ESP ULTIMA SYSTEM IS A STATE OF THE ART PRODUCT with
advanced Microprocessor Control that automatically controls and regulates conditioned air in
each zone to provide year-round climate control and comfort.
INSIDE THIS MANUAL You will find instructions for Zone Controller used with ActronAir ESP
Ultima system. Functions of the Master Controller, LM7-D and LM24W in conjunction with ESP
Ultima operation, are also explained.
NOTE: Basic and detailed functions of the Master Controller, LM7-D and LM24W,
are explained in the operation manual (0500-121) supplied with your A/C unit.
ACTRONAIR ESP ULTIMA SYSTEM is a highly advanced and efficient VAV system that lets
you control the temperature of each zone. It is also used in conjunction with ECM (Electronically
Commutated Motor) Indoor fan and ActronAir ESP digital compressor technology for maximum
energy savings and comfort.
IMPORTANT To ensure efficient and proper operation of your equipment, read and understand
all instructions contained in this manual and the Master Controller Manual. Failure to do so may
result in damage of equipment and warranty may be void.
CONTENTS
General Information ................................................... Page 1
Zone Controller Functions ......................................... Page 2
Turning Zone Controller On ....................................... Page 3
ESPAuto Mode ......................................................... Page 4
Zone Damper Blade Indicator .................................... Page 5
Fan Only Mode .......................................................... Page 6
Zone Temperature Display......................................... Page 8
Zone Open Mode ....................................................... Page 10
Trouble Shooting ....................................................... Page 11
Frequently Asked Questions ...................................... Page 12

3
ZONE CONTROLLER FUNCTIONS
Zone Indicator
ESP Auto Indicator
Illuminates when zone controller is
modulating the airflow.
OFF Indicator
Illuminates when zone is off and damper
is fully closed.
Set Temperature UP Button
Raises the set point for warmer
temperature.
Set Temperature DOWN Button
Lowers the set point for cooler
temperature.
Mode ON/OFF Button
Turn the zone ON or Off.
Room Temperature Button
View actual room temperature.
Damper Position Indicator
Indicates the position of of zones air
damper. (shown fully open damper)
COOL Indicator
Illuminates when zone is receiving
cooling.
HEAT Indicator
Illuminates when zone is receiving
heating.
Temperature Set Point Display
1
2
3
4
5
6
7
8
9
10
11
ROOM
TEMP
MODE
ON/OFF
SET
ZONE COOL HEAT
ESP
OFF
AUTO
C
TEMP
ZONE CONTROL
MAX
Zone Controller
11
10
8
7
6
9
5
4
3
2
1

4
TURNING ZONE CONTROLLER ON
Notes
* Zone Controller temperature setting can only be adjusted 2• 0C below or above
the Master Controller set point temperature. This is a factory set limit, which is
recommended in order to maintain system accuracy and maximize efficiency. Should
this require changing, contact ActronAir Technical support on freecall number :
1800 119 229
Master Controller shown above is LM7-D, same procedure applies with LM24W model.•
1Turn the system ON by pressing the button on Master
Controller LM7-D or LM24W.
2To turn the zone ON, press the button on Zone
Controller. Alternatively, press the designated zone on the
Master Wall Controller.
Zone Controller display will show the SET TEMPERATURE, ZONE and ESP AUTO.
3Set the desired temperature by pressing either the
SET TEMP UP / or DOWN / arrow key. *
For warmer room temperature, press the UP arrow key.• For cooler room temperature, press the DOWN arrow key.•
ON
OFF
MODE
ON/OFF
Master Wall Controller
FAN
AUTO
HEAT / COOL
AUTO
HEAT / COOL
LOW COOL
ON
OFF
PROGRAM
EXIT
SELECT
SET TEMP
SET TEMP
TIMER
REPEAT /
REPEAT /
RUMPUSFAMILY
BEDROOM 1
BEDROOM 1
KITCHEN DINING
MASTER BED
MASTER BED
BEDROOM 2
BEDROOM 2
BEDROOM 3
BEDROOM 3
2
1
3
3
ROOM
TEMP
MODE
ON/OFF
SET
ZONE COOL HEAT
ESP
OFF
AUTO
C
TEMP
ZONE CONTROL
MAX
Zone Controller
3
3
2

5
ESP AUTO MODE
Turning Off
3Press the button to turn off the zone. Alternatively,
press the designated zone button on the Master Controller.
When the designated zone LED in the Master Controller turns off,
the zone is off.
MODE
ON/OFF
Notes
In Zone Control ESPAUTO mode, the controller will adjust the position of zone• damper automatically in order to meet the desired temperature.
Heating mode will be displayed when the zone starts to heat the room.•
Cooling mode will be displayed when the zone starts to heat the room.•
1Press the button on until ESP AUTO appears
on the display.
2Set the desired temperature by pressing either the
SET TEMP UP / or DOWN / arrow key. *
For warmer room temperature, press the UP arrow key.• For cooler room temperature, press the DOWN arrow key.•
MODE
ON/OFF
ROOM
TEMP
MODE
ON/OFF
SET
ZONE COOL HEAT
ESP
OFF
AUTO
C
TEMP
ZONE CONTROL
MAX
Indications of COOL or HEAT will show
zone conditioning. (When zone damper is
providing warm or cold air to your zone).
Zone Controller
2
2
1
3
Master Wall Controller
FAN
AUTO
HEAT / COOL
AUTO
HEAT / COOL
LOW COOL
ON
OFF
PROGRAM
EXIT
SELECT
SET TEMP
SET TEMP
TIMER
REPEAT /
REPEAT /
RUMPUSFAMILY
BEDROOM 1
BEDROOM 1
KITCHEN DINING
MASTER BED
MASTER BED
BEDROOM 2
BEDROOM 2
BEDROOM 3
BEDROOM 3
3
2
2

6
ZONE DAMPER BLADE INDICATOR
DISPLAY STATUS
FULLY OPEN DAMPER BLADE
Allows full airflow through in order to meet your
required conditions.
PARTIALLY CLOSED DAMPER BLADE
Regulating airflow and temperature to
meet set conditions.
PARTIALLY OPEN DAMPER BLADE
Regulating airflow and temperature to
meet set conditions.
NO DAMPER BLADE INDICATOR
Room is satisfied with temperature.•Zone is turned off.•Zone is waiting on HEAT / COOL mode change.•
Note
When in ESPAUTO, damper blade indicator will automatically adjust itself to
regulate the correct amount of airflow (HEAT or COOL) in order to maintain the
desired setpoint temperature.

7
FAN ONLY MODE
1Ensure your air conditioner is turned off.
2Press the button. The current fan speed setting will
appear and the display backlight will turn on (if it is off).
3Press the button again to select HIGH, MED, LOW
fan speed.
4All open zones will circulate air throughout your home.
5If you wish to shut any particular zone in this mode, simply
turn off zone by pressing the designated zone button. Zone
LED will go off.
FAN
FAN
Notes
This mode is commonly used to circulate airflow without Cooling / Heating• throughout your home.
Quite often used on mild days to circulate fresh air through the home. Simply open•
a few windows and let the FAN ONLY MODE circulate fresh air through your home.
Master Wall Controller
FAN
AUTO
HEAT / COOL
AUTO
HEAT / COOL
LOW COOL
ON
OFF
PROGRAM
EXIT
SELECT
SET TEMP
SET TEMP
TIMER
REPEAT /
REPEAT /
RUMPUSFAMILY
BEDROOM 1
BEDROOM 1
KITCHEN DINING
MASTER BED
MASTER BED
BEDROOM 2
BEDROOM 2
BEDROOM 3
BEDROOM 3
3
2

8
FAN ONLY MODE
FAN MODE
will be displayed on zone control display when the Master Wall
Controller is set to circulation operation. During this period, zone damper will
be in fully open position for maximum air circulation.
Press the button to turn off the zone damper.
If you do not want the unit to circulate airflow in your room in this mode, simply
press the button in your zone controller or turn your zone OFF at the
Master Wall Controller
MODE
ON/OFF
MODE
ON/OFF
ROOM
TEMP
MODE
ON/OFF
SET
ZONE COOL HEAT
ESP
OFF
AUTO
C
TEMP
ZONE CONTROL
MAX
Zone Controller

9
ZONE TEMPERATURE DISPLAY
Notes
Room temperature displayed can be the temperature at a zone controller or at a
remote sensor or the average of both depending on your installation set up.
Average Room Temperature Display
1Press any of the buttons and the average room
temperature will be displayed for 3 seconds.
“INSIDE,” “0C” and “.” will be flashing. The temperature displayed is the average of
all activated zone sensors.
SELECT
Checking Individual Zone Temperatures
1Press any of the buttons.
2While “INSIDE,” “0C” and “.” are flashing, press the zone to
be checked.
“• INSIDE,” and “0C” will turn off. The selected zone LED and “.” flashes.
During this time, the selected zone temperature is displayed.•
3To check another zone, simply press the zone button while
the previous zone LED and “.” are flashing.
SELECT
TO CHECK TEMPERATURE AT MASTER WALL CONTROLLER
FAN
AUTO
HEAT / COOL
AUTO
HEAT / COOL
LOW COOL
ON
OFF
PROGRAM
EXIT
SELECT
SET TEMP
SET TEMP
TIMER
REPEAT /
REPEAT /
RUMPUSFAMILY
BEDROOM 1
BEDROOM 1
KITCHEN DINING
MASTER BED
MASTER BED
BEDROOM 2
BEDROOM 2
BEDROOM 3
BEDROOM 3
3
1
1
2

10
ZONE TEMPERATURE DISPLAY
TO CHECK TEMPERATURE AT ZONE CONTROLLER
Notes
To display the room/zone temperature for 45 minutes, press and hold button• for 5 seconds.
Press any button to exit.•
The room/zone temperature display can be the temperature at the zone controller or•
at a remote sensor or the average of both depending on your installation set up.
ROOM
TEMP
1Press the button.
Actual room/zone temperature will be displayed for several seconds then display
will return to setpoint temperature.
During this period, the blue LED on the button will flash indicating
the room temperature is shown on the display.
ROOM
TEMP
ROOM
TEMP
ROOM
TEMP
MODE
ON/OFF
SET
ZONE COOL HEAT
ESP
OFF
AUTO
C
TEMP
ZONE CONTROL
MAX
Zone Controller
1

11
ZONE OPEN MODE
Notes
It is not possible to control or adjust the temperature in this mode.•
This zone temperature will now depend on the systems operating mode•
(HEAT or COOL).
This mode has no control on room temperature, your sensor is ignored in this mode.•
A zone in OPn mode is like having a non-temperature controlled ON/OFF•
zone damper.
Zone 1 cannot be put in OPn mode.•
1Press the button twice in quick succession
until appears on the display.
indicates that the Zone Damper blade is in maximum open position.
MODE
ON/OFF
Turning Off Zone
2Press the button to turn off the zone.
Alternatively, press the designated zone button in the master
wall controller.
MODE
ON/OFF
Master Wall Controller
FAN
AUTO
HEAT / COOL
AUTO
HEAT / COOL
LOW COOL
ON
OFF
PROGRAM
EXIT
SELECT
SET TEMP
SET TEMP
TIMER
REPEAT /
REPEAT /
RUMPUSFAMILY
BEDROOM 1
BEDROOM 1
KITCHEN DINING
MASTER BED
MASTER BED
BEDROOM 2
BEDROOM 2
BEDROOM 3
BEDROOM 3
2
ROOM
TEMP
MODE
ON/OFF
SET
ZONE COOL HEAT
ESP
OFF
AUTO
C
TEMP
ZONE CONTROL
MAX
Zone Controller
1
2

12
For any assistance with your ESP Ultima System,
do not hesitate to contact our Customer Care Team for
technical support on freecall number:
1800 119 229
TROUBLE SHOOTING
Condition Causes or Check Points
The system does
not start. Check that 5 minutes has passed from the time you turned•
the system on, as the system has in-built safety timers.
Check thermostat settings are correct.• Check the thermostat “set-point” is set low enough for•
cooling or high enough for heating.
Check that the Master Controller is set to correct mode for•
COOL / AUTO / HEAT.
Air does not flow.
(Indoor Unit) Check if the unit is set in the correct mode•
COOL / AUTO / HEAT.
Check your Zone Controller is turned on. If using zone sensor,•
ensure your zone is turned on at the Master Controller.
During defrost cycle of the outdoor unit (in HEAT mode),•
the indoor fan will not operate.
Defrost cycle is indicated when “HEAT” is flashing on the
Master Controller display.
OFF is displayed on
my zone controller
and I cannot turn the
zone On.
This means the Master Controller is turned off.•
First turn on your air conditioner at the Master Controller.
You will now be able to turn on your Zone Controller.

13
FREQUENTLY ASKED QUESTIONS
Q. I cannot adjust my set point on my Zone Controller any more than 2Ohigher or
lower than the Master Controller.
A. 2Ois the default setting for master temperature offset.ActronAir recommend this 2O
offset to optimise temperature control and maximize energy efficiency. Moving this
setting +/- 2Owill result in temperature inaccuracy. Contact ActronAir technical support:
Tel. No. 1800 119 229.
Q. Cooling and Heating seems to take a long time to achieve temperature in ESP
fan mode. Am I using the correct settings?
A. ESP fan mode really comes into it’s own when minimal zones are used. For quicker
and more responsive Cooling and Heating, when using more than minimal zones,
select HIGH or CONT HIGH fan speed on Master Controller. This will boost heating
and cooling and is best optimized when you want to condition more than the minimal
zone set up.
Q. Cooling and Heating is not sufficient in my zone.
A. Air balancing is essential part of system commissioning in ESP Ultima system. The
duct design may be prohibiting the correct amount of airflow reaching your area.
Please contact your installer to ensure air balancing has been carried out.
Q. There is substantial air noise coming from my outlet.
A. If the outlet gets too noisy when the unit or zone is first turned on, the system maybe
over supplying airflow to your area. Ensure ESP fan mode is selected when minimal
zones are used.
Q. There are dashes across my control display.
A. Make sure you have not had a power interruption. If this is still present on the display
after 20 seconds, please contact your installer. Incorrect wiring or a broken circuit
could also cause these symptoms.
FAULT CODES:
When E? is displayed in the Master Controller or Zone Controller, take note of the
digits after E and contact your installer.
E3 - System has detected less than 2 sensors (Ultima requires at least 2 sensors
in circuit) or, a remote sensor is short circuit.
E5 - No Communication. The system is constantly relaying information back and forth.
This indicates the communication is not happening. Contact your installer to check
your wiring and cable’s integrity.

14
THIS PAGE INTENTIONALLY LEFT BLANK