ADAMS RITE RITE Touch User manual

User Guide
RITE Touch
* The functions and design of this product can be
changed for quality improvement without prior notice.

Safety Features
This product is for indoor
use only.
Do not force with a tool.
Keep the surface of the lock
free from foreign materials
and debris. Do not use touch
pad with dirty or wet fingers.
Ensure the glass door surface
is free from films and protective
coverings before installation.
For double doors, it is
recommended that the strike
side is stationary.
Keep the PIN code concealed.
Do not let an unauthorized
person observe the PIN code.
Ensure the door is securely
locked when leaving the area,
especially in manual lock mode.
Do not apply water directly to
the RITE Touch. Do not apply
chemical substances such as
alcohol during cleaning.
Do not attempt to
disassemble the RITE
Touch. To do so may
result in injury and
product damage.
2

Product Features
1
3
2
4
5
Advanced Mode
Advanced Mode can be used for professional and high security
management.
Magic Mirror
The Magic Mirror design allows the keypad to appear on the mirror as
soon as it is touched by a user. The user can also use the Magic Mirror to
visually survey the surroundings to monitor safety and security.
Safe Thumb-Turn
The manual thumb-turn enhances user security by requiring the pressing
of the two safe buttons on either side of the knob and simultaneous turning
of the knob.
Modern Design
The sophistication of the digital keypad technology is complemented by the
elegantly thin design of the solid lock base.
High Temperature Alarm
In the event of a fire, an audible alarm will be triggered and the lock will
automatically retract the deadbolt.
3

Components Overview
4
• User Guide
• Installation Template
• Card Keys (x4)
• Mounting Screws
Due to the nature of the Magic Mirror, exposure to intense direct light may change
the color of the product over time.
Front Body
Single Door Magnet Extension type deadbolt
10mm door thickness
gasket (13/32”)
Back Body Strike for Double Doors
Basic Contents
Specifications
Parts Specifications Remarks
Front Body 9/16(D) x 2-7/8(W) x 7-5/16(H) inches
14(D) x 73(W) x 186 (H) millimeters
Operating Temperature:
5 to 130 °F
-15 to 55 °C
Back Body 1-15/16(D) x 3-1/16(W) x 7-1/2(H) inches
49(D) x 77.5(W) x 190.5(H) millimeters
Battery 1.5 AA Alkaline batteries x4
Operating voltage: 4.5 – 6 V
Effective for 1 year
(based on 10 daily uses)

Specifications
5
Keypad
Battery
Cover
® Registration
Button
Manual
Thumb Turn
Slot for Remote
Control module
(sold separately)
Safe Knob
Open/Close
Button
Dead Bolt
Low Battery
Indicator
Card
Reader
Emergency Power
Supply Terminal
Front Body Back Body

Operating Instructions
6
User PIN Code must be 4 to 12 digits. Special characters [*] and [#] are not allowed.
Using the Keypad
Using the Card Reader
Registering User PIN Code
Registering Card Keys
Open Door with User PIN Code
Open Door with Card Key
Press ®
(Registration) button
Press ®
(Registration) button
Touch with palm
Contact Card Key
Press ®
(Registration) button
Press ®
(Registration) button
Touch with palm or
press [*] button to end
Enter User PIN Code
(4 to 12 digits)
Contact all the cards
you wish to register
one by one
Enter User PIN Code
(4 to 12 digits)
Caution
∙ Keep the door open while you register card keys to prevent accidentally getting locked out.
∙ Previously registered card keys will automatically be deleted when new card keys are registered.
∙ For security, please use only the RF cards provided in this package.

Operating Instructions
7
Locking the Door
To Close Door from Outside
To Close Door from Inside
If the door is twisted, the auto-lock feature will not function properly. Please check before use.
Step Icon Description
Manual lock status Touch the keypad on the front body gently with your
palm to lock the door.
Auto lock status The built-in auto lock sensor automatically locks the
door within 5 seconds after closing the door.
Step Icon Description
Manual lock status
(default setting)
Turn the manual thumb turn to unlock while pressing
safe thumb turn buttons together.
Press open/close button.
Auto lock status The built-in auto lock sensor automatically locks
the door within 5 seconds after closing the door. If
an auto-lock magnet is not installed, the auto-lock
feature is not enabled.

Operating Instructions
8
Forced Lock
Outside Forced Lock Setting - PIN Code
Outside Forced Lock Setting - Card Key
Touch with palm
Contact Card Key for 3 seconds until you hear 3 beeps.
Inside Forced Lock Setting
Press and hold [#]
button for 3 seconds
Enter User PIN Code
∙ If compulsory external lock is set up, the door open/close button will not function. The alarm will go off if
someone tries to open the door by manually opening/closing the unit.
∙ To open the door by manually opening/closing the unit under compulsory external lock setting,
completely turn the knob within one second, or else the door will lock itself again.
Press and hold the open/close button for 5 seconds.
Press the ® Registration button or turn the manual
thumb turn while pressing buttons together.
Set
Release

Operating Instructions
9
Auto/Manual Locking Mode
To Set Automatic Locking Mode
To Set Manual Locking Mode
Volume Setting Feature
*Factory default setting
*Factory default setting: High
After a door is locked by the auto-lock function, please verify that the door is completely locked.
Do not to leave the door open in manual lock mode.
Auto-lock setting locks a door within 5 seconds after closing the door.
Press ®
(Registration) button
Press ®
(Registration) button
Press ®
(Registration) button
Press ®
(Registration) button
Press ®
(Registration) button
Press ®
(Registration) button
Enter [#] button
Enter [#] button
Enter [#] button
Enter number and
on the keypad
Enter number and
on the keypad

Operating Instructions
10
Open/Close Button Setting Feature
Outside Forced Lock Setting - PIN Code
This feature disables and enables the open/close button. The on/off status of the function changes every time
the setting is modified. When the system is set to ‘off’, the open/close button is disabled.
Enter [#] button Enter number 2 and
4 on the keypad
Press ® button Press ® button

The alarm sounds for 30 minutes or until it is reset.
The alarm can be reset by presenting the card key, or entering the User PIN code, or pushing and holding
the open/close button for 5 seconds.
Safety Features
11
Alarm Features
Break in / Damage Alarm
High Temperature Alarm
Break in: When someone tries to break in by opening the door when it is locked, the alarm sounds.
Damage: When the front body is damaged due to forced separation or drilling, the alarm sounds.
In the event of a fire, an audible alarm is triggered and the lock automatically retracts the
deadbolt. The High Temperature Alarm releases the deadbolt automatically even when the
inside Forced Lock mode is set.

If incorrect security codes or unregistered card keys are attempted 5 times in a row, the RITE Touch locks out
for 3 minutes with the blinking LED.
A fake PIN code may be used to prevent the User PIN code from being unintentionally exposed. It may be
used with the User code, not the One Time PIN code.
* 3-Minute Lock mode will not affect an alarm and is sustained even after the product is rebooted.
* Once 3-Minute Lock mode is initiated, the Fake PIN Code will not work until the next normal verification
(card key verification, User PIN code, or open door from inside). In this case, please open the door with User
PIN Code.
Safety Features
12
3-Minute Lock Feature
Open Door with Fake PIN Code
To Release 3-Minute Lock
Press the Open/Close button.
Press the ® Registration button.
Open with the thumb turn by pressing both buttons and turning.
Method 1
Method 1
Method 2
Method 2
Method 3
Touch with palm
Touch with palm
Touch with palm
Touch with palm
Press Any button
Press PIN Code
Press Pin Code
Press Any button

The Remote Control Module may be purchased separately from
Adams Rite. It may be installed in the back body of the RITE Touch
to activate the remote control feature.
Remote Control Module
Optional Accessories
13
Remote Control Module
Installing the Remote Control Module
Press the Open/Close button.
Press the ® Registration button.
Open with the thumb turn by pressing both buttons and turning.
Touch with palm
Touch with palm
Remove batteries
Open the battery cover
in the Back Body
and remove
all batteries.
Install Remote Control Module
Connect the
Remote Control Module
to the connector.
Insert batteries
Note polarity of
batteries prior
to installation.
Insert batteries
An audible tone
will signal
successful startup.
1
3
2
4

Remote Control
To Register Remote Control
Reset Remote Control
Optional Accessories
Step Icon Description
Press ® (Registration)
button and #
Open the battery cover in the Back Body.
Press ® (Registration) button and then #.
Enter number 0 and 5
on the keypad
Enter number 0 and then 5 on keypad.
Register Remote
Control
Press the SET button on the Remote Control.
(Up to 5 Remote Controls may be registered)
Press ® (Registration)
button
Press the ® (Registration) button in the Back Body
again to complete the procedure.
Step Icon Description
Press ® (Registration)
button and #
Open the battery cover in the Back Body.
Press ® (Registration) button and then #.
Enter number 7 and 5
on the keypad
Enter number 7 and then 5 on keypad.
Press ® (Registration) Press the ® (Registration) button in the Back Body
again to complete the procedure.
1
2
3
4
1
2
3
14

Step Icon Description
Contact the 9V
Alkaline battery
Open the emergency cover. Hold the 9V alkaline
battery on the emergency power supply terminal
during the following steps.
Touch with palm Touch the keypad gently with your palm.
Enter User PIN Code Enter User PIN Code.
Touch with palm or
enter * button
Touch the keypad gently with your palm or enter
* button to conrm.
1
1
2
2
3
4
In the event of battery failure, the RITE Touch may be unlocked using a 9V battery.
Expiration Period
The product uses four 1.5V Alkaline AA batteries. They should be effective for one year (based on 10 daily uses).
(Users are advised to use authentic alkaline batteries.)
Low Battery Alarm
All four batteries must be replaced in the following situations:
• The low battery indicator light is illuminated on the front body
• The alarm melody sounds (nursery rhyme ting-a-ling melodies)
Emergency Power Supply for Discharged Batteries
Emergency Power Supply for Discharged Batteries
Emergency Power
The battery life varies depending on temperature, moisture levels,
frequency of use, and the quality of batteries.
15

www.adamsrite.com
800.872.3267
Table of contents
Other ADAMS RITE Lock manuals
Popular Lock manuals by other brands

Carbine
Carbine CDL7100-KDSC installation instructions

AmazonBasics
AmazonBasics B088XWZ95X manual

GEONFINO
GEONFINO G4PRO installation instructions

FUHR
FUHR autotronic 834 Installation, operation and maintenance instructions

Waferlock
Waferlock L701 user manual

Sargent and Greenleaf
Sargent and Greenleaf 3007 Direct Drive operating instructions