Resolved Issues
The following issues have been resolved in this release:
Documentation
The following documents are currently available for the Scalar 100 100:
Change
Request
Number Description
CR 35191 Corrects a condition in which SAC 73 errors occurred during cartridge
extractions from SDLT drives.
CR 40044 An extra character was added to the AIT media barcode serial number in the
3.32.0002 library code.
CR 41173 Corrects a firmware migration failure error that occurred when attempting to
update all 6 SDLT600 drives in the library with a FUP tape.
CR 41982 Corrects a condition in which Scalar 100 libraries timed out on a tape load and
unloaded after 2.5 minutes. The library timeout should be 16 minutes or
greater.
CR 42437 Improved tape pushing functionality to reduce failures during a put.
CR 42478 Current Hold Limit was increased to reduce SAC 81 errors and put retries.
CR 42528 Improves control management for media used for diagnostic functions in mixed
drive libraries.
CR 44450 Corrects a condition in which learned offset information was lost after library
columns were removed or replaced. Slot learned offset information is now
retained.
CR 47554 During put operations to storage and mailbox slots for LTO and SDLT libraries,
fingers remain open until the tape cartridge is completely seated in the
magazine.
Document Number Document Title
6-00667-05 Scalar 100 User’s Guide
6-00671-02 Scalar 100 Quick Start Guide
6-00064-06 ADIC Management Console 4.2 User’s Guide
6-00701-03 SNC 6101 Installation and Maintenance Guide
6-00676-03 SNC Firmware 4 User’s Guide
62-0197-01 SNC 5101 for the Scalar 100 User Manual
3-01153-06 Scalar 100 Documentation and Software CD