ADJ Products, LLC - www.adj.com - Par ZP100 3K User Manual Page 10
Par ZP100 3K System Menu
FReq - With this function you can adjust the dimming frequency.
1. Press the MENU button until “FReq” is displayed, then press ENTER.
2. Use the UP or DOWN buttons to adjust the dimming frequency between 900hz, 1000hz, 1100hz,
1200hz, 1300hz, 1400hz, 1500hz, 2500hz, 4000hz, 5000hz, 10000hz, 15000hz, 20000hz, or
250000hz.
3. Once you have found your desired dimming frequency press ENTER to conrm.
gAnn - In this menu you are able to make gamma corrections.
1. Press the MENU button until “gAnn” is displayed, then press ENTER.
2. Use the UP or DOWN buttons to scroll through gamma correction options.
3. Once you have found your desired gamma correction press ENTER to conrm.
dISP - This function will invert the display 180 degrees.
1. Press the MENU button until “dISP” is displayed, then press ENTER.
2. Press the UP button to select “dSIP” to “ip” the display, or “dISP” to revert the display to nor-
mal.
3. Press ENTER to conrm.
NAnd - This function will allow you to manually adjust each brightness, ne dimming, and
strobing. Fine dimming and strobing are only used with 3 channel mode.
1. Press the MENU button until “NAnd” is displayed, then press ENTER.
2. Use the UP and DOWN buttons to scroll through the settings. Once you have found your desired
function you would like to adjust press ENTER.
3. After you have pressed ENTER, use the UP and DOWN buttons to adjust the values. Once you
have made your adjustments press ENTER to set them. Press the MENU button to exit.
teSt - This function will run a self-test program.
1. Press the MENU button until “teSt” is displayed, then press ENTER.
2. The xture will now run a self test. Press the MENU button to exit and quit the self test.
tENP - With this function you can check the temperature of the xture.
1. Press the MENU button until “tENP” is displayed, then press ENTER.
2. The xture temperature will now be displayed. Press MENU to exit.
FhrS - With this function you can display the running time of the unit.
1. Press the MENU button until “FhrS” is displayed, then press ENTER.
2. The running time of the xture will now be displayed. Press MENU to exit.
ver - Use this function to display the software version of the unit.
1. Press the MENU button until “ver” is displayed, then press ENTER.
2. The display will now show the software version.