ADJ Products, LLC - www.adj.com - Dotz Panel 2.4 User Manual Page 9
Dotz Panel 2.4 System Menu
The LCD backlight will shut o after 30 seconds. To reactive the backlighting, press and hold
the MODE button for 5 seconds.
DMX Mode - Set the DMX Address and DMX Channel Mode.
1. Press the MENU button until “DMX Mode” and underneath “ADDR: XXX” and “CH:XX” is dis-
played, press ENTER.
2. “XXX” will now begin to ash, use the UP and DOWN buttons to nd your desired DMX address,
then press ENTER.
3. “XX” will now begin to ash, use the UP and DOWN buttons to nd your desired DMX Channel
mode, then press ENTER.
Secondary Mode - This will let you set your unit as a secondary unit in a primary/secondary
conguration.
1. Press the MENU button until “Secondry Mode” is displayed.
2. Your unit will now follow the behavior of the Primary unit.
Sound Mode - In this mode the unit will run in sound active mode.
1. Press the MENU button until “Sound Mode” is displayed.
2. Press ENTER to adjust your sound sensitivity. When you press ENTER the number next to “Sens”
will begin to ash, use the UP and DOWN buttons to adjust the sound sensitivity. Once you found
your desired sensitivity press ENTER to conrm.
3. When you press ENTER the number next to “FQN” will begin to ash, use the UP and DOWN
buttons to adjust the amount of times you would like the program to cycle before changing to the
next program. Press ENTER to conrm.
Auto Run.
1. Press the MENU button until “Auto Run” is displayed, and “FQN:XX” will be displayed under-
neath. “XX” representing the number displayed.
2. Press ENTER and the number will begin to ash, use the UP and DOWN buttons to adjust the
amount of times you would like the program to cycle before changing to the next program. Press
ENTER to conrm.
Built-In Programs - See the chart for Built-In Programs at the beginning of this section for de-
tailed descriptions of the available programs.
1. Press the MENU button until one of the Programs shown in the Built-In Program table is dis-
played. The displayed program depends on the last program you had set the unit to.
2. Press ENTER to move through the various adjustments of each program, and use the UP and
DOWN button to make adjustments.
Dim Curve - This setting will let you select your desired dimming curve.
1. Press the MENU button until “Dim Curve” is displayed, press ENTER.
2. 1 of 5 dimming curve settings will be displayed: Standard, Stage, TV, Architectural, or Theatre.
Use the UP and DOWN buttons to select your desired dimming curve and press ENTER to con-
rm.