2607 Colorado Blvd. Los Angeles, CA 90041
TEL: (323) 254-8131 FAX: (323) 254-4928
www.adrftech.com
_____________________________________________________________________________
_________
Advanced RF Technologies, Inc. Proprietary Document 4
-Technical Support: Will display ADRF’s Technical Support contact
information.
-Installer Contact Info: Will display the installer’s name, phone and e-mail
address.
Note: Once successfully logged in, the repeater model name and the site/cascade
ID will be displayed on the top of all the windows (except for the Main Window).
6. If you click on Control, the following window will appear:
In this window, the user can adjust the following parameters:
General Setting
- Automatic Gain Control (Default mode is Off)
- Downlink HPA on/off (Default mode is On)
- Uplink HPA on/off (Default mode is On)
- Uplink Tracking mode on/off (Default mode is Off)
Manual Gain Control
- Downlink Gain Control (40 to 65 dB @ 0.5 dB step, default value: 25 dB)
- Uplink Gain Control (40 to 65 dB @ 0.5 dB step, default value: 25 dB)
- Downlink AGC Level (15o 25 dBm @ 0.5 dB step)
- Uplink AGC Level (15o 25 dBm @ 0.5 dB step)
- Uplink Tracking Offset (0 to 10 dB @ 0.5 dB step - Default mode is Off)
System
- If you click the Reboot button, the following message box will appear: