Advan AMM213TD User manual

AUTO - SCANNING WITH DIGITAL CONTROL
LCD COLOR MEDICAL MONITOR
AMM213TD / AMM240WTD
Operation Manual
For future reference, record the serial number of your display
monitor in the space below :
Serial Number
The serial number is located on the back of the monitor

back of the monitor
ADVAN INT’L CORP.2010
All other trademarks are the property of their reference owners.
This document is subject to change without notice.
Advan provides this information as reference only. Reference to other vendor’s
products does not imply any recommendation or endorsement.
Revision Control
WARNING
The title «WARNING» is used to inform the users of pos-
sible causes that could inict the injury, death, or property
damage to the patients.
CAUTION
The title «CAUTION» is used to inform the users of pos-
sible causes that could inict the patients although it might
not severe enough to cause deaths.
NOTE
The title «NOTE» is used to inform the users of items that
are of importance in terms of installation, operation, or
maintenance of the Equipment although the failure does
not inict the bodily harm to the patients.
Date Description
REV.F 100810 Document number
AMM213TD/AMM240WTD 1
ENGLISH

TABLE OF CONTENTS
Product Description and Intended Use......................................................
Warnings and Cautions .............................................................................
Symbol Explanations.................................................................................
EU Declaration of Conformity for Medical Applications .............................
Safety Precaution ......................................................................................
Cleaning Your Monitor ...............................................................................
Power Management Function....................................................................
Preset Modes..............................................................................................
Video Signals.............................................................................................
PIP / POP / PBP function...........................................................................
DDC...........................................................................................................
Installation .................................................................................................
Connecting the Power Cord ......................................................................
User Function / Messages.........................................................................
OSD Section..............................................................................................
Troubleshooting.........................................................................................
Specication of (AMM213TD/AMM240WTD)............................................
Classication .............................................................................................
Electromagnetic Compatibility ...................................................................
Dimension Drawing (mm) of AMM213TD..................................................
Dimension Drawing (mm) of AMM240WTD...............................................
Connectors ................................................................................................
Description of Warranty .............................................................................
3
4
7
8
9
9
10
11
12
13
14
14
15
16
17
25
26
27
28
31
32
33
34
2User’s Guide

Product Description and Intended Use
Please check the following items are present when you unpack the box, and save
AMM213TD/AMM240WTD LCD Monitor is intended to for displaying images from
imaging system.
the packing materials in case you will need to ship or transport the monitor in future.
• AMM213TD/AMM240WTD LCD Monitor and two video cables (1) HD15
VGA cable* (1) DVI-D cable*
• AC Power cord**
• AC-Adapter
• Composite Video BNC Jack Cable and Super Video Cable
• User Manual and 4pcs VESA screws
*Might be optional item, check with local representative
**Might vary pending on region standard
CAUTION
Model No : JM-
W1150KA2400F04
Part No : PS-52142415001A
**
AMM213TD/AMM240WTD 3
ENGLISH

Warnings and Cautions
Please read this manual and follow its instructions carefully. The words warning,
caution, and note carry special meanings and should be carefully reviewed:
Warning The personal safety of the patient or physician may be
involved. Disregarding this information could result in
injury to the patient or physician.
Caution Special service procedures or precautions must be
followed to avoid damaging the instrument.
Note Special information to make maintenance easier or important
information more clear.
An exclamation mark within a triangle is intended to alert the
user to the presence of important operating and maintenance
instructions in the literature accompanying the product.
A lightning bolt within a triangle is intended to warn of the
presence of hazardous voltage. Refer all service to authorized
personnel.
Warning TO AVOID POTENTIAL SERIOUS INJURY TO THE USER
AND THE PATIENT AND/OR DAMAGE TO THIS DEVICE,
THE USER MUST :
Warranty is void if any of these warnings are disregarded.
ADVAN Int’l Corp accepts full responsibility for the effects on safety, reliability, and
performance of the equipment only if:
• Re-adjustments, modications, and/or repairs are carried out exclusively
by ADVAN Int’l Corp.
• The electrical installation of the relevant operating room complies with the
applicable IEC and CE requirements.
Warning Federal law (United States of America) restricts this
device to use by, or on order of a physician.
The ADVAN Int’l Corp AMM213TD/AMM240WTD monitor has been tested under UL
60601-1 standard and UL listed for Medical application.
ADVAN Int’l Corp reserves the right to make improvements in the product(s)
described herein. Product(s), therefore, may not agree in detail to the published
design or specications. All specications are subject to change without notice.
Please contact ADVAN Int’l Corp directly or phone your local ADVAN Int’l Corp sales
representative or agent for information on changes and new products.
4User’s Guide

Warnings
1. Read the operating manual thoroughly and be familiar with its contents prior to using
this equipment.
2. Carefully unpack the unit and check if any damage occurred during shipment.
3. Should any solid object or liquid fall into the panel, unplug the unit and have it checked
4. Uplug the unit if it is not to be used for an extended period of time. To disconnect the
cord, pull it out by the plug. Never pull the cord itself.
6. Test this equipment prior to a medical procedure. This monitor was fully tested at the
factory before shipment.
7. Avoid removing covers on control unit to avoid electric shock.
manual.
9. Pay close attention to the care, cleaning instructions in this manual. A deviation may
cause damage (refer to the Cleaning section).
10. DO NOT STERILIZE MONITOR.
11. Read the entire instruction manual before assembling or connecting the camera.
12. Do not place the monitor or any other heavy object on the power cord. Damage to the
13. Monitor with power supply is suitable for use in patient environment.
14. DO NOT stack more than 8 boxes high
16. The use of the accessory or cable with the unit other than those specified may result
in increased EMISSIONS or decreased IMMUNITY of the unit.
15. The unit should not be used adjacent to or stacked with other equipment and that if
adjacent or stacked use is necessary, the unit should be observed to verify normal
operation in the configuration in which it will be used.
This equipment has been tested and found to comply with the limits for medical devices in
IEC 601-1-2:2003. These limits are designed to provide reasonable protection against harm-
ful interference in a typical medical installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to other devic-
es in the vicinity. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to other devices, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving device.
- Increase the separation between the equipment.
- Connect the equipment into an outlet on a circuit different from that to which the other
device(s) are connected.
NOTICES TO USER
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any inter-
ference received, including interference that may cause undesired operation.
FCC WARNING
expressly approved by the party responsible for compliance could void the user’s authority
to operate the equipment. The user could lose the authority to operate this equipment if an
AMM213TD/AMM240WTD 5
ENGLISH

Cautions
1. The AC Adapter must be plugged into a Grounded power outlet.
2. Use only the proprietary AMM213TD/AMM240WTD power supply for the
AMM213TD/AMM240WTD monitor. Make a proper connection by ensuring that the
shrink tubing completely secures the connection between the DC power cord and the
extension cord.
3. Turn power off when unit is not in use.
4. Never operate the unit right after having transported from a cold location directly to a
warm location.
5. Do not expose the monitor to moisture or directly apply liquid cleaners directly to the
screen. Spray the cleaning solution into a soft cloth and clean gently.
6. Handle the monitor with care. Do not strike or scratch the screen.
7. Do not block the monitor cooling vents. The monitor is cooled by natural convection
and has no fan.
8. Do not force the monitor past 28 degrees of vertical when adjusting the screen
position. (For monitors equipped with stands only.)
9. Remove the power module and connection when transporting the unit.
10. Save the original carton and associated packing material. They will be useful should
you have to transport or ship the unit.
11. Allow adequate air circulation to prevent internal heat buildup.
12. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains,
draperies) that may block the ventilation slots.
13. Do not install the unit near sunlight, excessive dust, mechanical vibration or shock.
14. The unit is designed for operation in a horizontal position. Never operate the unit in
a vertical position.
15. Keep the unit away from equipment with strong magnets (i.e. a large loudspeaker.)
16. Do not expose the monitor to moisture or excessive dust.
17. Equipment with SIP/SOP connectors should either comply with IEC 60601-1 and/or
IEC 60601-1-1 harmonized national standard or the combination should be evaluated.
Do not touch the patient with signal input or output connectors.
18. Use only a hospital grade power supply cord.
19.This equipment has been tested and found to comply with the limit for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable generate uses and can radiate radio frequency energy, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in
a particular installation, which can be detemined by turing the equipment off and on,
the user is encourage to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving device.
• Increase the separation distance between the equipment.
• Connect the equipment to an outlet on a circuit different from that to which the
other device(s) are connected.
• Consult the manufacturer or eld service technican for help.
20. Grounding reliability can only be achieved when the equipment is connected to an
equipment receptacle labeled “Hospital Only” or “Hospital Grade.”
Note To connect to an international power supply, use a an attachment plug
appropriate for the power outlet.
Note Refer to the “Electromagnetic Compatibility” (EMC) section of this manual to
ensure EMC. The AMM213TD/AMM240WTD must be installed and operated
according to the EMC information provided in this manual.
6User’s Guide

Symbol Denitions
AMM213TD/AMM240WTD 7
Dangerous: High Voltage
Direct Current
Serial Number
Top – Bottom
Fragile
Do not get wet
Consult accompanying documents.
Indicates proof of conformity to applicable European Economic
Community Council directives and to harmonized standards
published in the ofcial journal of the European Communities.
Authorized Representative in Europe
Indicates protective earth ground.
For indoor use only.
Medical Equipment is in accordance with UL 60601-1 and CAN/
CSA C22.2 No. 601.1 in regards to electric shock, re hazards,
and mechanical hazards.
Tested to comply with FCC Class B standards.
DC power control switch
51LJ
Medical Equipment
E215822
ENGLISH

EU Declaration of Conformity for Medical Applications
A Declaration of Conformity has been led for this product. A sample
of this document may be found in the addendum which accompa-
nied this manual. For a copy of the Declaration of Conformity docu-
ment, please contact ADVAN Int’l Corp. and request for AMM213TD/
AMM240WTD DOC.
Prepare for Unpack
Before you unpack your monitor, prepare a suitable workspace. You
need a stable and level surface near a grounded wall outlet in an area
which is relatively free of glare from sunlight or other sources of bright
light. The monitor is cooled by natural convection (it has no fan).
For optimum performance, do not block the cooling vents.
While unpacking the monitor, inspect it and other package contents
for shipping damage that could cause a re or shock hazard. Imme-
diately report any shipping damage to the carrier or transportation
company and contact customer service for monitor in the future or in
case of return.
After you unpack the monitor, make sure the following items are in-
cluded
• Monitor with video cable
• AC adapter with cable
CAUTION: AC Adapter must be plugged into Grounded a power outlet
CAUTION : AC adapter
Model No: JMW1150KA2400F04
Part No: PS-52142415001A
• This operations manual
Note: Your system provider may offer alternative cords or cables
depending on the installation requirement and local geography issues.
8User’s Guide

SAFETY PRECAUTION
· Avoid placing the monitor, or any other heavy object, on the power cord
to prevent re or electrical shock from damage to the power cord.
· Do not expose the monitor to rain, excessive moisture, or dust to avoid
re or shock hazard.
· Do not cover the slots or openings of the monitor for proper heat
dissipation. Always put the monitor in a place where there is adequate
ventilation.
· Avoid placing the monitor against a bright background or where sunlight
or other light sources may reect on the area of the monitor. Place the monitor
just below eye level.
· Handle with care when transporting the monitor.
· Refrain from giving the shock or scratch to the screen, as screen is
fragile.
CLEANING YOUR MONITOR
No specic liquid or chemical necessary when cleaning this LCD monitor
However, we suggest to clean the monitor with non-abrasive cloths and cleaning
solutions used in hospitals to clean similar equipment. We recommend using 70%
Isopropyl alcohol for the screen surface and warm water and a mild detergent for all
other surfaces. Other acceptable cleaning agents are listed below:
• 70% isopropyl alcohol
• Cidex (2.4% glutaraldehyde solution)
• 0.5% Chlorhexidine in 70% isopropyl alcohol
To clean the screen, do not spray liquid cleaners directly on to the unit. Stand away
Form the monitor and spray cleaning solution onto a cloth. Without applying exces-
sive pressure, clean the screen with the slightly dampened rag.
AMM213TD/AMM240WTD 9
ENGLISH

POWER MANAGEMENT FUNCTION
The monitor is equipped with the power management function which automatically
reduce the power consumption when not in use in three power level modes.
• Stand-by Mode
The monitor goes into stand-by mode when the horizontal sync signal is off for
about 10 seconds. In this mode, the screen goes off and the power LED blinks
for 1 seconds On and 1 second Off. The screen is displayed after the horizontal
sync signal is restored.
• Suspend Mode
The monitor goes into suspend mode when the vertical sync signal is off for
about 10 seconds. The power consumption during this is 27 W. In this mode,
the screen goes off and the power LED blinks for 1 seconds On and 1 second
Off. The screen is displayed after the vertical sync signal is restored.
• Off Mode
The monitor goes into power-off mode when the vertical and horizontal sync
signals are off for about 10 seconds. In this mode, the screen goes off and the
power LED blinks for 1 seconds On and 1 second Off. The screen is displayed
after the vertical and horizontal sync signals are restored.
Power Management System
The AMM213TD/AMM240WTD Medical Monitor power management proposal.
Provides four phases of power-saving modes by detecting the horizontal sync
signal as shown in the table below.
When the monitor is power saving mode or detects an incorrect timing, the screen
will be blank and power LED indicator will blink.
10 User’s Guide
State Normal
Operation
DPMS
Standby
DPMS
Suspend DPMS Off
Horizontal Sync Active Inactive Active Inactive
Vertical Sync Active Active Inactive Inactive
Video Active Blanked Blanked Blanked
Power Indicator Green Green Flashing (1
sec. Interval)
Green Flashing (1
sec. Interval)
Green Flashing (1
sec. Interval)
Power
Consumption 100W 27W 27W 27W

PRESET MODES
AMM213TD/AMM240WTD 11
Resolution
Horizontal
frequency
( KHz )
Vertical
frequency
( Hz )
Pixel clock
( MHz )
640 x 350 @70Hz 31.469 70.087 25.175
640 x 480 @60Hz 31.469 59.940 25.175
640 x 480 @75Hz 37.500 75.000 31.500
640 x 480 @85Hz *1 43.269 85.008 36.000
800 x 600 @56Hz 35.156 56.250 36.000
800 x 600 @60Hz 37.879 60.317 40.000
800 x 600 @72Hz *1 48.077 72.188 50.000
800 x 600 @75Hz 46.875 75.000 49.500
800 x 600 @85Hz *1 53.674 85.061 56.250
1024 x 768 @60Hz 48.363 60.004 65.000
1024 x 768 @70Hz 56.476 70.069 75.000
1024 x 768 @75Hz 60.023 75.029 78.750
1024 x 768 @85Hz *1 68.677 84.997 94.500
1152 x 864 @60Hz 54.348 60.053 80.000
1152 x 864 @70Hz 63.955 70.016 94.200
1152 x 864 @75Hz 67.500 75.000 108.000
1280 x 1024 @60Hz 63.974 60.013 108.500
1280 x 1024 @75Hz *1 79.976 75.025 135.000
1600 x 1200 @60Hz 75.000 60.000 162.000
1920 x 1200 @60Hz *2 74.099 59.999 154.125
*1 available for AMM213TD
*2 available for AMM240WTD
DVI and VGA input signal formats
ENGLISH

Video Signals
12 User’s Guide
Format DVI VGA C-Video S-Video SDI1 SDI2
Component / RGB
Y/Pb/Pr RGB
NTSC *1 O O
PAL *2 O O
480/59.94i O O O O O
480/59.94p O O
576/50i O O O O O
576/50p O O O O
720/50p O O O O O O
720/59.94p O O O O O O
720/60p O O O O O O
1080/23.98psf O O O O O
1080/24psf O O O O O
1080/23.98p O O O O O
1080/24p O O O O O
1080/25p O O O O O O
1080/29.97p O O O O O O
1080/30p O O O O O O
1080/50i O O O O O O
1080/59.94i O O O O O O
1080/60i O O O O O O
1080/59.94p O O
1080/60p O O
*1 NTSC-M, NTSC-433
*2 PAL-BDGHI, PAL-M, PAL-N, PAL-60

AMM213TD/AMM240WTD 13
PIP / POP / PBP function
The following combination options are available to you:
Main PIP VGA DVI SDI1 SDI2 C-Video S-Video Component
/ RGBs SOG
VGA O O O O O O O
DVI O O O O O O O O
SDI1 O O O O O O O
SDI2 O O O O O O O
C-Video O O O O O O O
S-Video O O O O O O O O
Component /
RGBs O O O O O O O O
SOG O O O O O O
ENGLISH

DDC
To make your installation easier, the monitor is able to Plug and Play with your
system if your system also supports DDC protocol. The DDC (Display Data
Channel) is a communication protocol through which the monitor automatically
informs the host system about its capabilities, for example, supported resolutions
and corresponding timing. The monitor supports DDC1 and DDC2B standard.
INSTALLATION
To install the monitor to your host system, please follow the steps as given below:
Steps
1. Use the supplied video cable (DVI, VGA, S-Video, C-Video) then connect to the
host system accordingly.
2. Connect the DC power to the DC power connector on the monitor.
3. Connect one end of AC power cord into the AC Adapter and the other end to AC
power outlet.
4. Then turn the host system on and then the monitor.
5. If the monitor still does not function properly, please refer to the troubleshooting
section to diagnose the problem.
14 User’s Guide
DVI VGA SDI INS - Video
C - Video /
SOG
DC Power
IN
OUT
RGB / Component SDI OUT

CONNECTING the POWER CORD
* Check rst to make sure that the power cord you use is the correct type required
for your area.
* This monitor has an universal AC adapter that allows operation in either
AC 100 - 240 V ac voltage area. No user-adjustment is required.
* Plug one end of the power cord to the AC adapter, plug another end to a proper
AC outlet.
The cord set should have the appropriate safety approvals for the country in which
the equipment will be installed and marked HAR.
For 120 volt Applications, use only UL Listed deachable power cord with NEMA
conguration 5-15P type (parallel blades) plug cap. For 240 volt applications use
only UL Listed Detachable power supply cord with NEMA conguration 6-15P type
(tandem blades) plug cap.
AMM213TD/AMM240WTD 15
Hospital-grade
power cord
Power Supply
Model No: JMW1150KA2400F04
Part No: PS-52142415001A AMM213TD/
AMM240WTD
Extension power cord (optional)
Manufacturer: Bridgepower
Part No: CB-47D2004P57MF (15ft) or
CB-47D2022P86MF (75ft)
ENGLISH

16 User’s Guide
User Functions / Messages
Key Name and Function
Power LED : Lights up to indicate the power is turned ON.
Power Switch : To power ON or OFF the monitor.
Rotary switch : With the OSD menu activated, increases the value of the selected
(Ture Right) parameter or moves rightward in OSD menu.
Rotary switch : With the OSD menu activated, increases the value of the selected
(Ture Left) parameter or moves leftward in OSD menu.
PIP Switch : To enable or disable Picture In Picture function.
PBP Switch : To enable or disable Picture By Picture function.
POP Switch : To enable or disable Picture On Picture function.
Adjust Switch : To activate or deactivate image adjustment in sub screen of PIP,
PBP, POP mode.
Locker Switch : To turn ON or OFF the system.
How to access the menu
1. Push the “Knob” button to activate the OSD menu.
2. Able to turn left or right the button to select those icons. The icon will be
highlighted when is selected.
3. Push the “knob” button to go into the another OSD menu.
4. Turn left or right “Knob” button to increase or decrease the number of selected
function.
5. In order to exit from the OSD menu in a different layer, then choose the “Exit
option”. In case of long pushing and holding the button around two or three
seconds, then it will completely out from the menu regardless wherever you are.
6. Turn the “Knob” button in a fast way to the left or right, while the menu is not
activated, then input signal menu will turns up with “V” mark which is chosen
current available input signal. You can switch to another input signal source by
turning the knob slowly then select the target source by pushing the knob.

AMM213TD/AMM240WTD 17
OSD Section
Chromatic Adjust Color Temp, Gamma
Visual Adjust Brightness, Contrast, Phase, Chroma,
Sharpness-H, Sharpness-V
Setting Adjust Scale Mode, Color Space, Mirror, Freeze Frame,
Zoom / Pan, PIP, POP, PBP
Advanced Adjust OSD Position Control, Screen Control, DPMS, Auto
Source Select, Smart Select, Restore Factory, Key Lock
Information Adjust Custom Entry, SN, Run Time, Input Format
Exit Exit the menu
Main Menu
ENGLISH

18 User’s Guide
OSD Section
Chromatic
Color Temp Change the color temperature - D65, D93, S1, S2
Gamma Change the gamma value - 1.8, 1.9, 1.95, 2.1, 2.1S, 2.2, 2.3,
2.4, 2.4S, S0, Radio graph
Exit Exit the menu
Visual
Brightness Adjust the brightness of panel (Range 0 - 100)
Contrast Adjust the contrast of video (Range 0 - 100)
Phase Adjust the phase of video (Range 0 - 100)
*available for C and S - video
Chroma Adjust the chroma of video (Range 0 - 100)
*available for C and S - video
Sharpness-H Set the sharpness of horizontal image (Range 0 - 100)
Sharpness-V Set the sharpness of vertical image (Range 0 - 100)
Exit Exit the menu

OSD Section
Setting
Scale Mode Change the scale mode - Fill all, One to One,
Vertical - ll, Horizontal - ll, Fill aspect ratio
Color Space Change color space between RGB and YPbPr
*available for Component and RGBS
Mirror Off / On mirror image
Freeze Frame Off / On freeze frame
Zoom / Pan Enable zoom - in and pan function
PIP Enable PIP (Picture In Picture) function
POP Enable POP (Picture On Picture) function
PBP Enable PBP (Picture By Picture) function
Exit Exit the menu
AMM213TD/AMM240WTD 19
ENGLISH
This manual suits for next models
1
Table of contents
Other Advan Monitor manuals

Advan
Advan AMM190WTD User manual

Advan
Advan AGM15TK User manual

Advan
Advan AMM190WTD2 User manual

Advan
Advan AMM240WTD User manual

Advan
Advan 240-030-970 User manual

Advan
Advan AMM215WTTP User manual

Advan
Advan VISION ELECT HDTV User manual

Advan
Advan AMM215MWTD User manual

Advan
Advan AMM215WTD User manual

Advan
Advan AMM15TK3 User manual