ITALO 2_URBAN_TP_IM_ENG - Rev.04 of 27/10/14 Page 1 of 4
MOUNTING AND MAINTENANCE
INSTRUCTION
MOUNTING AND MAINTENANCE
TP mounting
ITALO 2 URBAN TP is providedwith post-top attachment for
tenon with diameter of 60mm / 2-3/8" (Pic. 1).
Mount the fixture as indicated on Pic. 1.
M8 / 5/16 set screws
Hex key: 4mm / 5/32"
Twisting moment: 8Nm
Pic. 6
A
Electrical parts
Remove the cover as per instructions on Pic. 2 to Pic. 5.
To gain access to the electrical components, release the latch (A – Pic.
6) and lift the upper frame until the hinge is locked (Pic. 7).
Pic. 1
Pic. 2
Release the set screw of
the bracket
Pic. 3
Remove the
cover
Pic. 5
Put the cover back on and
fasten by set screw (B).
Hinge
Pic. 7
Pic. 4
Pass the cable through the bracket,and
then through the cable gland or the
membrane.
B
ITALO 2_URBAN_TP_IM_ENG - Rev.04 of 27/10/14 Page 2 of 4
MOUNTING AND MAINTENANCE
INSTRUCTION
Pic. 8 Pic. 9
Tighten the screws until the cable is
firmly secured
Plastic M20 cable gland
Adjustable wrench: 24mm
Twisting moment: 3.5Nm
-------------------------------------------------
Plastic M25 cable gland
Adjustable wrench: 30mm
Twisting moment: 5Nm
CABLE GLAND MEMBRANE
Electrical line connection
- Luminaire with cable gland: follow the instructions as per Pic. 8. You must secure the external cable by tightening
plastic holder on the "on-load switch".
- Luminaire with membrane: follow the instructions as per Pic. 9. You must secure the external cable by tightening
plastic holder on the "on-load switch".
In case the luminaire is equipped with PLM device, before closing the luminaire, annotate the serial number of the device.
C
C
CLASS I
CLASS II C
A
B
A
B
C D
D
Cable gland Membrane
A 6 ÷7 mm / 1/4" 6 ÷7 mm / 1/4"
B < 25m / 1" < 25mm / 1"
C M20: 8 ÷12mm / .31"÷.47"
M25: 10 ÷ 17mm / .39"÷.67"
8 ÷ 12mm / .31"÷.47"
D ≤2.5mmq / 12AWG ≤2.5mmq / 12AWG
ITALO 2_URBAN_TP_IM_ENG - Rev.04 of 27/10/14 Page 3 of 4
MOUNTING AND MAINTENANCE
INSTRUCTION
Luminaire closure
To close the luminaire, follow the instructions from Pic. 10 to Pic. 12.
Pic. 10 Pic. 11 Pic. 12
Lift the upper frame Unlock the hinge and move down the
upper frame
Locked position
LED module removal
1) Disconnect the LED
connector (C);
2) Loosen the screws (E);
3) Remove the LED
module.
LED module
repositioning
1) Put the LED modules
back to the original
position
2) Tighten the screws (E);
3) Connect the LED
connector (C).
Gear tray removal
1) Disconnect the main
feed connector (B);
2) Disconnect the LED
connector (C);
3) Loosen the screws (D);
4) Remove the gear tray.
Gear tray repositioning
1) Replace in the original
position the gear tray;
2) Tighten the screws (D);
3) Connect the LED connector
(C);
4) Connect the
main feed
connector (B).
C
E
DB
SPD MAINTENANCE
The protection device is equipped with system that excludes power supply at the end of life of the luminaire.
If the luminaires switches-off when the system is still fed, the activity of the protection device should be checked looking at signaling
LED.
To check this, use the appropriate tool and ask the manufacturer for instructions
LED ON _ Right functioning of the SPD LED OFF _ End of life SPD, replace the SPD
ITALO 2_URBAN_TP_IM_ENG - Rev.04 of 27/10/14 Page 4 of 4
MOUNTING AND MAINTENANCE
INSTRUCTION
NOTE
a) The luminaire can be installed close to flammable surfaces.
b) Class II luminaires must be installed in such a way that it is impossible for any exposed metal part to come in contact with electrical
components.
c) The device has developed in compliance with the current standards; it is necessary that the installation is done properly, according with the
instructions supplied.
d) The present instruction paper has to be kept for any future maintenance operation on the luminaire. Non compliance with the above will
automatically release AEC Illumination from any responsibility and the warranty will be voided
ITALO 2 URBAN
luminaire is classified
under “EXEMPT
GROUP” according
to photobiologycal
safety standard
IEC/EN 62471.
NO RISK
for the operators and
end users.
The crossed-out wastebasket symbol on the appliance means that at the end of its useful lifespan, the product must be disposed of separately
from ordinary household wastes. The user is responsible for delivering the appliance to an appropriate collection facility at the end of its useful
lifespan. Appropriate separate collection to permit recycling, treatment and environmentally compatible disposal helps prevent negative impact
on the environment and human health and promotes recycling of the materials making up the product. For more information on available
collection facilities, contact your local waste collection service.
F Fuse 110Vac 10A (provide the fuse externally if not supplied with the luminaire) PD Protection device
CN Connector PSU Power Supply
S On-load switch CD Control device
ITALO 2 URBAN 1-2M 10.1 ÷ 10.7kg / 23.6 Lbs
ITALO 2 URBAN 3-4M 10.5 ÷ 11.1kg / 24.5 Lbs
ITALO 2 URBAN 5M-8M 11.0 ÷ 11.5kg / 25.4 Lbs
Protection grounding
(only in class I)
L
N
LED
modules
CN2
PSU
WIRING SCHEME
S1
PD
F1
(
o
p
tion
)
L
N
PLM WIRING SCHEME
Protection grounding
(only in class I)
CN1
LED
modules
CN2
PSU
S1
PD
F1
(
o
p
tion
)
CN1
CD
Side area: 0.64 Sq.f / 0.06m2
Base area: 2.69 Sq.f / 0.25m2
Form factor: 1.2
Ta 35°C / 95F
Use Indoor / Outdoor
Max height of installation: 15m / 50'F

This manual suits for next models

1

Other AEC ILLUMINAZIONE Outdoor Light manuals

AEC ILLUMINAZIONE Kaos 1 Manual

AEC ILLUMINAZIONE

AEC ILLUMINAZIONE Kaos 1 Manual

AEC ILLUMINAZIONE ITALO 1 Manual

AEC ILLUMINAZIONE

AEC ILLUMINAZIONE ITALO 1 Manual

AEC ILLUMINAZIONE GALILEO 1 Manual

AEC ILLUMINAZIONE

AEC ILLUMINAZIONE GALILEO 1 Manual

AEC ILLUMINAZIONE BASE BA/1 User manual

AEC ILLUMINAZIONE

AEC ILLUMINAZIONE BASE BA/1 User manual

Popular Outdoor Light manuals by other brands

Somogyi home MX 639 instruction manual

Somogyi

Somogyi home MX 639 instruction manual

SIGNIFY RoadFocus PLUS installation instructions

SIGNIFY

SIGNIFY RoadFocus PLUS installation instructions

OttLite 2598311P quick start guide

OttLite

OttLite 2598311P quick start guide

Maretti QUATRO FLOOR L H710 instruction manual

Maretti

Maretti QUATRO FLOOR L H710 instruction manual

Platek Block Series Assembly instructions

Platek

Platek Block Series Assembly instructions

Maretti CHIARA ROUND quick start guide

Maretti

Maretti CHIARA ROUND quick start guide

EE Systems Group eLEDing EE812W-AI8 quick start guide

EE Systems Group

EE Systems Group eLEDing EE812W-AI8 quick start guide

Original BTC Walter US-FT587 instruction manual

Original BTC

Original BTC Walter US-FT587 instruction manual

Ecom Instruments H-251 A instruction manual

Ecom Instruments

Ecom Instruments H-251 A instruction manual

JCL Lighting Nyx 330 manual

JCL Lighting

JCL Lighting Nyx 330 manual

DSI LIGHTING DS18690 Use and care guide

DSI LIGHTING

DSI LIGHTING DS18690 Use and care guide

LIGMAN ODESSA 2 installation manual

LIGMAN

LIGMAN ODESSA 2 installation manual

ESYLUX OSL 40 LED SPOT 5K manual

ESYLUX

ESYLUX OSL 40 LED SPOT 5K manual

Sulion BASIC manual

Sulion

Sulion BASIC manual

LIGMAN VANCOUVER 27 installation manual

LIGMAN

LIGMAN VANCOUVER 27 installation manual

Kira Home RV-TL2667-1 quick start guide

Kira Home

Kira Home RV-TL2667-1 quick start guide

BEMKO KAFLER KASTEL R-LFK-030-6K installation instructions

BEMKO

BEMKO KAFLER KASTEL R-LFK-030-6K installation instructions

LIGMAN BILLUND 6 installation manual

LIGMAN

LIGMAN BILLUND 6 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.