AEG Powertools AEGLDM50 User manual

2
I
MPORTANT SAFETY INSTRUCTIONS
SYMBOLS
LASER CLASSIFICATION
WARNING:
TECHNICAL DATA
UNPACKING
AEGLDM50
AAA batteries x 2
Original instructions
Quick start guide
Belt clip
CD
Safety alert
Regulatory Compliance Mark (RCM). Product
meets applicable regulatory requirements.
Please read the instructions carefully before
starting the machine.
Do not dispose of electric tools together with
household waste material. Electric tools and
electronic equipment that have reached the
end of their life must be collected separately
and returned to an environmentally compatible
recycling facility.
Dust and Water resistance IP54
Receiving Lens 14 mm
Focus 35 mm
Maximum Measuring Range 50 meters
Minimum Measuring Range 0.05 meters
Absolute Accuracy @ < 10m ± 1.5 mm (Max)
Repeatability Accuracy @ < 10m ± 1.5 mm (Max Typical, 2σ)
Repeatability Accuracy @ > 10m Increase ± 0.25 mm / meter
(Max Typical, 2σ)
Measurement Time 0.5 s
Display Type LCD ( 22.7 mm x 31 mm )
Power Type AAA 2x (Alkaline Battery)
Battery Life 10000 (Single Measure)
Laser Output Power 0.6 mW ~ 0.95 mW
(Class 2, 650nm )
Laser Spot Size 25 mm x 30 mm @ 16 m(Max)
Laser Radiation Vertical Angle ±1 degree
Laser Radiation Horizontal Angle ±1 degree
Device auto off time 180 seconds
Laser auto off time 30 seconds
Operating Temperature Range -10°C to +50°C
Storage Temperature Range -25°C to +70°C
Weight without Battery 80 g
3
The reflective surface could reflect the beam back at the
operator or other persons.
Keep extremities in a safe distance from the moving
parts.
Carry out periodic test measurements. Particularly
before, during and after important measurements.
Watch out for erroneous measurements if the product is
defective or if it has been dropped or has been misused
or modified.
WARNING: Use of controls, adjustments, or the
performance of procedures other than those specified in
the manual may result in hazardous radiation exposure.
The laser distance measurer has limits of use. (Refer to
the “Technical data” section). Attempts to measure
outside the maximum and minimum range will cause
inaccuracy. Use in adverse conditions including too hot,
too cold, very bright sunlight, rain, snow, fog, or other
vision restricting conditions will result in inaccurate
readings.
When the laser distance measurer is brought into a
warm environment from very cold conditions, or vice
versa, allow it to come to the surrounding temperature
before use.
Always store the laser distance measurer indoors, avoid
exposing the tool to shock, continuous vibration or
extreme temperatures.
Always keep the tool away from dust, liquids and high
humidity. These may damage internal components or
affect accuracy.
Do not use aggressive cleaning agents or solutions. Use
only a clean, soft cloth for cleaning.
Avoid heavy impact to or dropping of the measuring tool.
The accuracy of the tool should be checked before use if
it has been dropped or subjected to other mechanical
stresses.
Any repair required on this laser product should be
performed only by authorised service personnel.
Do not operate the product in explosion hazardous
areas or in aggressive environments.
Only use chargers recommended by the manufacturer to
charge the batteries.
Flat batteries must not be disposed of with
household waste. Care for the environment and
take them to the collection points provided in
accordance with national or local regulations.
The product must not be disposed with
household waste. Dispose of the product appropriately
in accordance with the national regulations in force in
your country. Adhere to the national and country specific
regulations. Please contact your local authority or your
dealer for how to dispose of batteries properly.
WARNING:
Avoid direct eye exposure. The laser beam can cause
flash blindness.
Do not stare into the laser beam or direct it towards
other people unnecessarily.
Don't dazzle other individuals.
WARNING:
Do not operate the tool around children or allow children
to operate the tool.
Techtronic Industries GmbH
Max-Eyth-Straße 10
71364 Winnenden
Germany
Techtronic Industries (Australia) Pty. Ltd.
31 Gilby Road,
Mount Waverley VIC 3149,
Australia
Techtronic Industries N.Z. Limited
2 Landing Drive, Mangere,
Auckland, New Zealand 2022

Other manuals for AEGLDM50

1

Popular Measuring Instrument manuals by other brands

VOLTCRAFT GM-100 operating instructions

VOLTCRAFT

VOLTCRAFT GM-100 operating instructions

Parametric TCR user manual

Parametric

Parametric TCR user manual

Mantech Ap2000 instruction manual

Mantech

Mantech Ap2000 instruction manual

zatech ZMCBR-H65 manual

zatech

zatech ZMCBR-H65 manual

sauter FS Series manual

sauter

sauter FS Series manual

SPS PRO X 200 instruction manual

SPS

SPS PRO X 200 instruction manual

UEi C163 quick start guide

UEi

UEi C163 quick start guide

Cirris Signature 1000R+ user guide

Cirris

Cirris Signature 1000R+ user guide

Black & Decker BDTM250 instruction manual

Black & Decker

Black & Decker BDTM250 instruction manual

Maximum Maestro manual

Maximum

Maximum Maestro manual

Gryzzly H3022 owner's manual

Gryzzly

Gryzzly H3022 owner's manual

Raydon RA-170 user manual

Raydon

Raydon RA-170 user manual

Ecomatik DD-L1 user manual

Ecomatik

Ecomatik DD-L1 user manual

PCE Instruments PCE-CSM 6 manual

PCE Instruments

PCE Instruments PCE-CSM 6 manual

SBC Saia PCD ALD1D5FS Assembly and operating instructions

SBC

SBC Saia PCD ALD1D5FS Assembly and operating instructions

Pro DP1008 Series product manual

Pro

Pro DP1008 Series product manual

Squirrel OMICRON 116 user manual

Squirrel

Squirrel OMICRON 116 user manual

Geometrics MagEx quick start guide

Geometrics

Geometrics MagEx quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.