OPERATION
Please make sure that you have already read and fully understand the WARNING section on page 1.
Making Measurements with the AC Current Probe Model JM835A
• Connect the black and red terminals to the Ampere AC range of your DMM or current measuring
instrument. Select the appropriate current range (5A AC). Clamp the probe around the conductor to be
tested. If the reading is less than 2 A, select the lower range until you obtain the best resolution. Read the
value display on the DMM and multiply it by the probe ratio (3000/5 = 600). (If reading = 0.592A AC, the
current flowing through the probe is 0.592 A x 600 = 355.2 A).
• For best accuracy: carefully center the conductor inside the probe jaw, avoid if possible, the proximity of
other conductors which may create noise.
Tips for Making Precise Measurements
• When using a current probe with a meter, it is important to select the range that provides the best
resolution. Failure to do this may result in measurement errors.
• Make sure that probe jaw mating surfaces are free of dust and contamination. Contaminants cause air
gaps between the jaws, increasing the phase shift between primary and secondary. It is very critical for
power measurement.
MAINTENANCE:
Warning
• For maintenance use only original replacement parts.
• To avoid electrical shock, do not attempt to perform any servicing unless you are qualified to do so.
• To avoid electrical shock and/or damage to the instrument, do not get water or other foreign agents into
the probe.
Cleaning
To ensure optimum performance, it is important to keep the probe jaw mating surfaces clean at all times.
Failure to do so may result in error in readings. To clean the probe jaws use a very fine sand paper (fine
600) to avoid scratching the jaw, then gently clean with a soft, oil cloth.
REPAIR AND CALIBRATION
You must contact our Service Center for a Customer Service Authorization number (CSA#). This will ensure
that when your instrument arrives, it will be tracked and processed promptly. Please write the CSA# on the
outside of the shipping container.
Chauvin Arnoux®, Inc. d.b.a. AEMC®Instruments
15 Faraday Drive •Dover, NH 03820 USA
(800) 945-2362 (Ext. 360) • (603) 749-6434 (Ext. 360) • [email protected]
(Or contact your authorized distributor)
NOTE: All customers must obtain a CSA# before returning any instrument.
TECHNICAL AND SALES ASSISTANCE
If you are experiencing any technical problems, or require any assistance with the proper use or application
of this instrument, please contact our technical hotline:
(800) 945-2362 (Ext. 351) • (603) 749-6434 (Ext. 351) • techsupport@aemc.com
LIMITED WARRANTY
The current probe is warranted to the owner for a period of two years from the date of original purchase
against defects in manufacture. This limited warranty is given by AEMC®Instruments, not by the distributor
from whom it was purchased. This warranty is void if the unit has been tampered with, abused or if the
defect is related to service not performed by AEMC®Instruments.
Full warranty coverage and product registration is available on our website at:
www.aemc.com/warranty.html.
Please print the online Warranty Coverage Information for your records.
AC Current Probe
Model JM835A
User Manual
DESCRIPTION
The JM835A (Catalog #2110.84) is designed for use in industrial environments. The “squared” jaws permit
multiple conductor or bus bar positioning. The current output makes it the perfect tool for measurement
with DMMs, recorders, power and harmonic meters. The Model JM835A is compatible with any AC
Ammeter, multimeter, or other current measuring instrument with an input impedance lower than 1Ω. To
achieve the stated accuracy, use the JM835A with the DMM having an accuracy of 0.75%.
WARNING
These safety warnings are provided to ensure the safety of personnel and proper operation of the
instrument.
• Read the instruction manual completely and follow all the safety information before attempting to
use or service this instrument.
• Use caution on any circuit: Potentially high voltages and currents may be present and may pose
a shock hazard.
• Read the Safety Specifications section prior to using the current probe. Never exceed the
maximum voltage ratings given.
• Safety is the responsibility of the operator.
• ALWAYS connect the current probe to the display device before clamping the probe onto the
sample being tested.
• ALWAYS inspect the instrument, probe, probe cable, and output terminals prior to use. Replace
any defective parts immediately.
• NEVER use the current probe on electrical conductors rated above 600V in overvoltage category
III (CAT III). Use extreme caution when clamping around bare conductors or bus bars.
INTERNATIONAL ELECTRICAL SYMBOLS
This symbol signifies that the current probe is protected by double or reinforced insulation. Use
only factory specified replacement parts when servicing the instrument.
This symbol signifies CAUTION! and requests that the user refer to the user manual before
using the instrument.
This is a type A current sensor. This symbol signifies that application around and removal
from HAZARDOUS LIVE conductors is permitted.
DEFINITION OF MEASUREMENT CATEGORIES
Cat. IV: For measurements performed at the primary electrical supply (<1000V) such as on primary
overcurrent protection devices, ripple control units, or meters.
Cat. III: For measurements performed in the building installation at the distribution level such as on
hardwired equipment in fixed installation and circuit breakers.
Cat. II: For measurements performed on circuits directly connected to the electrical distribution system.
Examples are measurements on household appliances or portable tools.
RECEIVING YOUR SHIPMENT
Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify your
distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the
carrier and notify your distributor at once, giving a detailed description of any damage.
99-MAN 100077.v8 02/18
ELECTRICAL SPECIFICATIONS
Current Range:
1 to 2400A AC, continuous cycle for
the full temperature range
(3000A if temperature < 35°C or 95°F)
Transformation Ratio:
3000:5
Output Signal:
1.666 mA AC/A AC (5A at 3000A)
Accuracy and Phase Shift*:
Primary current
150A
600A
3000A
Accuracy %
3%
1.5%
1%
Phase shift
3°
1.5°
1°
(*Reference conditions: 23°C±3°K, 20 to 85%
RH, 48 to 65 Hz, external magnetic field < 40
A/m, no DC component, no external current
carrying conductor, test sample centered.)
Load impedance 0.2Ω.
Overload: 3600A during 10 mn
Accuracy: Per IEC 185-26-27
Class 1 (5 VA) from 48 to 1000 Hz
Open Secondary Voltage:
< 42V by limiting circuit
Frequency Range:
30 Hz to 5 kHz; current derating above
1 kHz for continuous use
Load Impedance: ≤ 1Ω
Working Voltage: 600V AC
Common Mode Voltage: 600V AC
Influence of Adjacent Conductor:
0.005A/A AC
Influence of Conductor in Jaw Opening:
1% ± 0.1A of reading
MECHANICAL SPECIFICATIONS
Operating Temperature:
14° to 122°F (-10° to 50°C)
Storage Temperature:
-13° to 176°F (-25° to 80°C)
Influence of Temperature:
< 0.1% per 10°K
Jaw Opening: 3.54" (90 mm)
Maximum Conductor Size:
Cable: 2.52" Ø max. (64mm)
Bus bar: 1.97 x 5.31" (50 x 135 mm)
2.52 x 3.94" (64 x 100 mm)
Envelope Protection:
IP 20 (IEC 529)
Drop Test:
500 mm (IEC 68-2-32)
Mechanical Shock:
100 g (IEC 68-2-27)
Vibration:
10/55/10 Hz, 0.15 mm (IEC 68-2-6)
Polycarbonate Material:
Handles: 10% fiberglass charged
polycarbonate UL 94 V0
Jaws: ABS UL 94 V2
Dimensions:
4.72 x 12.40 x 1.89" (120 x 315 x 48 mm)
Weight:
2.65 lbs. (1200 g)
Colors:
Dark gray handles with red jaws
Output:
5 ft (1.5m) lead with safety 4mm banana plug
SAFETY SPECIFICATIONS
Electrical:
Double insulation or reinforced insulation between
primary or secondary and outer case of handle
upon IEC 1010
Common Mode Voltage:
- 600V Category III, Pollution: 2
- 300V Category IV, Pollution: 2
Electromagnetic Compatibility:
EN 50081-1 Class B
EN 50082-2 Electrostatic discharge
IEC 1000-4-2
Radiated field IEC 1000-4-3
Fast transients IEC 1000-4-4
Magnetic field at 50/60 Hz IEC 1000-4-8
ORDERING INFORMATION
Current Probe JM835A.................. Cat #2110.84
Includes a user manual and a product warranty
and registration card.
Accessories:
Banana plug adapter
(to non-recessed plug)..................... Cat #1017.45

This manual suits for next models

1

Other AEMC instruments Measuring Instrument manuals

AEMC instruments 6501 User manual

AEMC instruments

AEMC instruments 6501 User manual

AEMC instruments SR601 User manual

AEMC instruments

AEMC instruments SR601 User manual

AEMC instruments FlexProbe 24-3001 User manual

AEMC instruments

AEMC instruments FlexProbe 24-3001 User manual

AEMC instruments MN185 User manual

AEMC instruments

AEMC instruments MN185 User manual

AEMC instruments 5050 Operating and safety instructions

AEMC instruments

AEMC instruments 5050 Operating and safety instructions

AEMC instruments MD304 User manual

AEMC instruments

AEMC instruments MD304 User manual

AEMC instruments MR525 User manual

AEMC instruments

AEMC instruments MR525 User manual

AEMC instruments 1510 User manual

AEMC instruments

AEMC instruments 1510 User manual

AEMC instruments MN290 User manual

AEMC instruments

AEMC instruments MN290 User manual

AEMC instruments AmpFlex 193-24-BK User manual

AEMC instruments

AEMC instruments AmpFlex 193-24-BK User manual

AEMC instruments 502 User manual

AEMC instruments

AEMC instruments 502 User manual

AEMC instruments Clamp-On 3705 User manual

AEMC instruments

AEMC instruments Clamp-On 3705 User manual

AEMC instruments 6550 User manual

AEMC instruments

AEMC instruments 6550 User manual

AEMC instruments MN185 User manual

AEMC instruments

AEMC instruments MN185 User manual

AEMC instruments 6505 User manual

AEMC instruments

AEMC instruments 6505 User manual

AEMC instruments 6505 User manual

AEMC instruments

AEMC instruments 6505 User manual

AEMC instruments PEL 105 User manual

AEMC instruments

AEMC instruments PEL 105 User manual

AEMC instruments 6528 User manual

AEMC instruments

AEMC instruments 6528 User manual

AEMC instruments SIMPLE LOGGER L100 User manual

AEMC instruments

AEMC instruments SIMPLE LOGGER L100 User manual

AEMC instruments A196-24-BK User manual

AEMC instruments

AEMC instruments A196-24-BK User manual

AEMC instruments MN261 User manual

AEMC instruments

AEMC instruments MN261 User manual

AEMC instruments CA846 User manual

AEMC instruments

AEMC instruments CA846 User manual

AEMC instruments JM852 User manual

AEMC instruments

AEMC instruments JM852 User manual

AEMC instruments 6536 User manual

AEMC instruments

AEMC instruments 6536 User manual

Popular Measuring Instrument manuals by other brands

PCB Piezotronics 3743F1150G Installation and operating manual

PCB Piezotronics

PCB Piezotronics 3743F1150G Installation and operating manual

Musical Fidelity M8xtt Instructions for use

Musical Fidelity

Musical Fidelity M8xtt Instructions for use

SMC Networks PFG3 0 Series Operation manual

SMC Networks

SMC Networks PFG3 0 Series Operation manual

ATD Tools 8658 owner's manual

ATD Tools

ATD Tools 8658 owner's manual

Comet Commeter C0111 manual

Comet

Comet Commeter C0111 manual

DKK-TOA WQC-30 instruction manual

DKK-TOA

DKK-TOA WQC-30 instruction manual

Endress+Hauser analytikjena Biometra TMS operating manual

Endress+Hauser

Endress+Hauser analytikjena Biometra TMS operating manual

WIKA 732.14.100 per ATEX operating instructions

WIKA

WIKA 732.14.100 per ATEX operating instructions

Wabtec Mors Smitt Nieaf Smitt NI 19 PLUS manual

Wabtec

Wabtec Mors Smitt Nieaf Smitt NI 19 PLUS manual

RoboCam F12 Quick installation guide

RoboCam

RoboCam F12 Quick installation guide

ANALOX ACG+ Service & Troubleshooting Manual

ANALOX

ANALOX ACG+ Service & Troubleshooting Manual

SUTO S601 Instruction and operation manual

SUTO

SUTO S601 Instruction and operation manual

Magnescale DS50NR5 instruction manual

Magnescale

Magnescale DS50NR5 instruction manual

Niigata seiki WDI-3058SP instruction manual

Niigata seiki

Niigata seiki WDI-3058SP instruction manual

EIJKELKAMP Aquameter Series instruction manual

EIJKELKAMP

EIJKELKAMP Aquameter Series instruction manual

Bosch RTM 430 Description of the Unit

Bosch

Bosch RTM 430 Description of the Unit

Ditel IORD1826 Quick installation guide

Ditel

Ditel IORD1826 Quick installation guide

YOKOGAWA GD402G /M1 user manual

YOKOGAWA

YOKOGAWA GD402G /M1 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.