AC Current Probe
Model MN01
User Manual
DESCRIPTION
The MN01 (Cat. #2129.17) is small, compact AC current probe. Designed to meet the most stringent
demands in industry and electrical contracting, they also meet the latest safety and performance
standards. The probe has a measurement range up to 150Arms which makes it a perfect tool for
measurement with DMMs, recorders. The Model MN01 is compatible with any AC ammeter, multimeter,
or other current measurement instrument with an input impedance lower than 10 . To achieve the
stated accuracy, use the probe with an ammeter having an accuracy of 0.75% or better.
WARNING
These safety warnings are provided to ensure the safety of personnel and proper operation of the
instrument.
Read the instruction manual completely and follow all the safety information before attempting
to use or service this instrument.
Use caution on any circuit: Potentially high voltages and currents may be present and may
pose a shock hazard.
Read the Safety Specifications section prior to using the current probe. Never exceed the
maximum voltage ratings given.
Safety is the responsibility of the operator.
ALWAYS connect the current probe to the display device before clamping the probe onto the
sample being tested.
ALWAYS inspect the instrument, probe, probe cable, and output terminals prior to use.
Replace any defective parts immediately.
NEVER use the current probe on electrical conductors rated above 600V in overvoltage
category III (CAT III). Use extreme caution when clamping around bare conductors or bus bars.
INTERNATIONAL ELECTRICAL SYMBOLS
This symbol signifies that the current probe is protected by double or reinforced insulation. Use
only factory specified replacement parts when servicing the instrument.
This symbol signifies CAUTION! and requests that the user refer to the user manual before
using the instrument.
This is a type A current sensor. This symbol signifies that application around and removal from
HAZARDOUS LIVE conductors is permitted.
Voltage limiting circuit
DEFINITION OF MEASUREMENT CATEGORIES
CAT II: For measurements performed on circuits directly connected to the electrical distribution system.
Examples are measurements on household appliances or portable tools.
CAT III: For measurements performed in the building installation at the distribution level such as on
hardwired equipment in fixed installation and circuit breakers.
CAT IV: For measurements performed at the primary electrical supply (<1000V) such as on primary
overcurrent protection devices, ripple control units, or meters.
RECEIVING YOUR SHIPMENT:
Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify
your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately
with the carrier and notify your distributor at once, giving a detailed description of any damage.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
ELECTRICAL SPECIFICATIONS
Nominal Range: 150A
Measurement Range: 2 to 150AAC
Transformation Ratio: 1000:1
Output Signal: 1mA/A from 1 to 10
Accuracy and Phase Shift*:
Accuracy 1 load: 2.5% Reading ± 0.15A
Accuracy 10 load: 3% Reading ± 0.15A
Phase Shift: Not Specified
*Reference conditions: 18°C to 28°C, 20 to 75% RH, external
magnetic field <40 A/m, 48 to 65 Hz sine wave, distortion
factor less than 1%, no DC component, no external current
carrying conductor, test sample centered. Load impedance
1 or 10 .
Overload: 170A for 10 min ON, 30 min OFF
Frequency Range: 48 to 500Hz
Open Secondary Voltage: 30V
Working Voltage: 600Vrms
Common Mode Voltage: 600Vrms
Influence of Adjacent Conductor:
< 2mA/A at 50 Hz
Influence of Conductor Position in Jaw:
0.1% of mA output @ 50/60Hz
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
Influence of Frequency:
< 2% of mA output from 65 to 500Hz
Influence of Temperature:
0.2%/10°K
Influence of Humidity (10 to 90% RH):
0.1% of mA
MECHANICAL SPECIFICATIONS
Operating Temperature:
14° to 122°F (-10° to +50°C)
Storage Temperature:
-40° to 176°F (-40° to +80°C)
Maximum Cable Diameter:
One Ø 0.39 (10mm)
Case Protection:
IP 40 (IEC 529)
Drop Test:
Test per IEC 68-2-32:
1.0m drop on 38mm of Oak on concrete
Mechanical Shock:
Test per IEC 68-2-27
Vibration: Test per IEC 68-2-6
Dimensions:
4.43 x 1.48 x 1.02"
(112.5 x 37.5 x 26mm)
Weight:
180 g (6.5 oz)
Polycarbonate Material:
Jaws: Red Polycarbonate
Case: Dark Polycarbonate
Opening Operations - Life:
> 50,000
Output:
Double/reinforced insulated 5 ft (1.5m) lead with
safety 4mm banana plug
Altitude: <2000 m
Indoor use only
SAFETY SPECIFICATIONS
Electrical:
Conforms to IEC 1010-2-32. ed. 2 2003
Common Mode Voltage:
300V CAT IV, 600V CAT III, Pollution Degree 2
Electromagnetic Compatibility:
EN61326-1 (ed. 97)+A1 (ed. 98) : transmission
and immunity in an industrial site
ORDERING INFORMATION
AC Current Probe MN01 ................ Cat. #2129.17
Accessories:
Banana plug adapter
(to non-recessed plug) ..................... Cat #1017.45
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
99-MAN 100332 v 0 1
OPERATION
Please make sure that you have already read and fully understand the WARNING section on page 1.
Making Measurements with the AC Current Probe Model MN01
Connect the black lead of the current probe to common and the red lead to the AC current input on
your DMM or other current measuring instrument. Select the appropriate current range (400mAAC
range). Clamp the probe around the conductor to be tested. If the reading is less than 400mA, select the
lower range until you obtain the best resolution. Read the value display on the DMM and multiply it by the
probe ratio (1000/1). (If reading = 0.159A, the current flowing through the probe is 0.159A x 1000 =
159AAC)
For best accuracy, avoid if possible, the proximity of other conductors which may create noise.
Tips for Making Precise Measurements
When using a current probe with a meter, it is important to select the range that provides the best
resolution. Failure to do this may result in measurement errors.
Make sure that probe jaw mating surfaces are free of dust and contamination. Contaminants cause air
gaps between the jaws, increasing the phase shift between primary and secondary. It is very critical for
power measurement.
MAINTENANCE:
Warning
For maintenance use only original factory replacement parts.
To avoid electrical shock, do not attempt to perform any servicing unless you are qualified to do so.
To avoid electrical shock and/or damage to the instrument, do not get water or other foreign agents
into the probe
Cleaning
To ensure optimum performance, it is important to keep the probe jaw mating surfaces clean at all times.
Failure to do so may result in error in readings. To clean the probe jaws, use very fine sand paper (fine
600) to avoid scratching the jaw, then gently clean with a soft oiled cloth.
REPAIR AND CALIBRATION
You must contact our Service Center for a Customer Service Authorization number (CSA#). This will
ensure that when your instrument arrives, it will be tracked and processed promptly. Please write the CSA#
on the outside of the shipping container.
Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments
(Or contact your authorized distributor)
NOTE: All customers must obtain a CSA# before returning any instrument.
TECHNICAL AND SALES ASSISTANCE
If you are experiencing any technical problems, or require any assistance with the proper use or
application of this instrument, please contact our technical hotline:
LIMITED WARRANTY
he current probe is warranted to the owner for a period of year from the date of original
purchase against defects in manufacture. This limited warranty is given by AEMC®Instruments,
not by the distributor from whom it was purchased. This warranty is void if the unit has been tampered
with, abused or if the defect is related to service not performed by AEMC® Instruments.
Full warranty coverage and product registration is available on our website at:
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

This manual suits for next models

1

Other AEMC instruments Measuring Instrument manuals

AEMC instruments 6505 User manual

AEMC instruments

AEMC instruments 6505 User manual

AEMC instruments Simple Logger AmpFlex AL24-2500 User manual

AEMC instruments

AEMC instruments Simple Logger AmpFlex AL24-2500 User manual

AEMC instruments JM865A User manual

AEMC instruments

AEMC instruments JM865A User manual

AEMC instruments 502 User manual

AEMC instruments

AEMC instruments 502 User manual

AEMC instruments A196-24-BK User manual

AEMC instruments

AEMC instruments A196-24-BK User manual

AEMC instruments OX5042 User manual

AEMC instruments

AEMC instruments OX5042 User manual

AEMC instruments FlexProbe 24-3001 User manual

AEMC instruments

AEMC instruments FlexProbe 24-3001 User manual

AEMC instruments 6527 User manual

AEMC instruments

AEMC instruments 6527 User manual

AEMC instruments MN09 User manual

AEMC instruments

AEMC instruments MN09 User manual

AEMC instruments MD304 User manual

AEMC instruments

AEMC instruments MD304 User manual

AEMC instruments Clamp-On 3705 User manual

AEMC instruments

AEMC instruments Clamp-On 3705 User manual

AEMC instruments MN261 User manual

AEMC instruments

AEMC instruments MN261 User manual

AEMC instruments CA846 User manual

AEMC instruments

AEMC instruments CA846 User manual

AEMC instruments 6550 User manual

AEMC instruments

AEMC instruments 6550 User manual

AEMC instruments MR525 User manual

AEMC instruments

AEMC instruments MR525 User manual

AEMC instruments MD305 User manual

AEMC instruments

AEMC instruments MD305 User manual

AEMC instruments 6528 User manual

AEMC instruments

AEMC instruments 6528 User manual

AEMC instruments 5070 User manual

AEMC instruments

AEMC instruments 5070 User manual

AEMC instruments JM840A User manual

AEMC instruments

AEMC instruments JM840A User manual

AEMC instruments SL261 User manual

AEMC instruments

AEMC instruments SL261 User manual

AEMC instruments SR759 User manual

AEMC instruments

AEMC instruments SR759 User manual

AEMC instruments 6501 User manual

AEMC instruments

AEMC instruments 6501 User manual

AEMC instruments Measure Up PowerPad III User manual

AEMC instruments

AEMC instruments Measure Up PowerPad III User manual

AEMC instruments AmpFlex 193-24-BK User manual

AEMC instruments

AEMC instruments AmpFlex 193-24-BK User manual

Popular Measuring Instrument manuals by other brands

McLaughlin VISION FLX2 manual

McLaughlin

McLaughlin VISION FLX2 manual

Schaeffler OPTIME user manual

Schaeffler

Schaeffler OPTIME user manual

Extech Instruments SDL550 user guide

Extech Instruments

Extech Instruments SDL550 user guide

Ebtron Advantage IV HTA104-P Startup guide

Ebtron

Ebtron Advantage IV HTA104-P Startup guide

Siko SA01 user manual

Siko

Siko SA01 user manual

Spire Metering Technology UM103EM-737-1.1 user manual

Spire Metering Technology

Spire Metering Technology UM103EM-737-1.1 user manual

CARLO GAVAZZI CERTUS installation manual

CARLO GAVAZZI

CARLO GAVAZZI CERTUS installation manual

Extech Instruments SDL150 user guide

Extech Instruments

Extech Instruments SDL150 user guide

PCB Piezotronics IMI SENSORS 624B61 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 624B61 Installation and operating manual

OWL WaveSource Series Operation guide

OWL

OWL WaveSource Series Operation guide

FLIR EXTECH INSTRUMENTS PQ34-12 user guide

FLIR

FLIR EXTECH INSTRUMENTS PQ34-12 user guide

Electrosmith 2144 LPF Build guide

Electrosmith

Electrosmith 2144 LPF Build guide

AMALGAMATED INSTRUMENT RM4-FX Operation and instruction manual

AMALGAMATED INSTRUMENT

AMALGAMATED INSTRUMENT RM4-FX Operation and instruction manual

e-survey E3L user guide

e-survey

e-survey E3L user guide

Akron Style operating instructions

Akron

Akron Style operating instructions

BRUEL & KJAER HBK Z6AM Mounting instructions

BRUEL & KJAER

BRUEL & KJAER HBK Z6AM Mounting instructions

HEIDENHAIN ND 200 installation instructions

HEIDENHAIN

HEIDENHAIN ND 200 installation instructions

Mianyang Weibo Electronic WBV412M05 user manual

Mianyang Weibo Electronic

Mianyang Weibo Electronic WBV412M05 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.