GE moisture.IQ User manual

Moisture and Oxygen
910-298 Rev. E
September 2017
bhge.com
moisture.IQ
User’s Manual


bhge.com
© 2017 Baker Hughes, a GE company – All rights reserved.
Baker Hughes reserves the right to make changes in specifications and features shown herein, or discontinue the product
described at any time without notice or obligation. Contact your BHGE representative for the most current information. The
Baker Hughes logo is a trade mark of Baker Hughes, a GE company. The GE Monogram is a trademark of the General Electric
Company.
moisture.IQ
Multi-Channel Moisture and Oxygen Analyzer
User’s Manual
910-298 Rev. E
September 2017

[no content intended for this page]

moisture.IQ User’s Manual iii
Contents
Product Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Terms and Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Typographical Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Safety Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Auxiliary Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Environmental Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ix
Chapter 1. Installation
1.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.2 Unpacking the moisture.IQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.3 Installing the moisture.IQ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.4 Choosing an Installation Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.4.1 General Site Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.4.2 Low Voltage Directive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.5 Moisture Probe Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.5.1 Temperature Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.5.2 Moisture Condensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.5.3 Static or Dynamic Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.5.4 Pressure Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.5.5 Long-Term Storage & Operational Stability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.5.6 Interference Effects. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.5.7 Corrosive Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.6 Sample System Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.6.1 Moisture Sample Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.6.2 Oxygen Sample Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.7 Mounting the Hygrometer System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.7.1 Mounting the Electronics Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.7.2 Mounting a Sample System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.7.3 Mounting the Oxygen Cell. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.8 Installing the Probes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.8.1 Moisture Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.8.2 Adapting an Existing TF-Series Probe Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
1.8.3 Adapting an Existing M-Series Probe Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
1.8.4 Pressure Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
1.8.5 Delta F Oxygen Cell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
1.9 Making Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
1.9.1 Using the Lever to Make Wiring Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
1.9.2 Connecting the Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
1.9.3 Connecting Moisture Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
1.9.4 Connecting the Delta F Oxygen Cell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

Contents
iv moisture.IQ User’s Manual
1.10 Establishing a Gas Flow Through the Oxygen Cell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
1.11 Connecting an Auxiliary Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
1.12 Connecting Analog Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
1.13 Connecting Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Chapter 2. Operation
2.1 Powering Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
2.2 Measurement Display Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
2.3 The Help Button. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
2.4 The Data Element Editor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
2.5 Initial Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
2.6 Restarting the System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
2.7 Shutting Down the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Chapter 3. Using the Settings Menu
3.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
3.2 Display Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
3.3 System Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
3.4 File Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
3.5 Screen Alignment (Weatherproof and Explosion-Proof) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
3.6 Screen Configuration (Weatherproof and Explosion-Proof). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
3.7 Notifications Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
3.8 Fault Alarm Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
3.9 Module Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
3.10 Service Menu Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
3.10.1 Software Update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
3.10.2 Restart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
3.10.3 Shut Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Chapter 4. Using the Outputs, Alarms and Logger Menus
4.1 Setting Up the Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
4.1.1 Configuring an Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
4.1.2 Testing the Selected Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
4.1.3 Trimming the Selected Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
4.1.4 Setting the Output Range Error Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
4.2 Setting Up the Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
4.2.1 Configuring an Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
4.2.2 Testing the Selected Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
4.2.3 Setting the Alarm Range Error Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
4.3 Setting Up and Running Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Chapter 5. Using the Configuration Menu
5.1 Configuring the Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59

moisture.IQ User’s Manual v
Contents
5.1.1 The Probe Configuration Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
5.1.2 Configuring Delta F Oxygen Sensor Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
5.1.3 Calibrating Individual Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
5.1.4 Setting the Probe Auto-Cal Schedule. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
5.2 Calibrating the Probes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
5.2.1 Entering Calibration Data Automatically . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
5.2.2 Entering Calibration Data Manually . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
5.3 Tagging the Inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
5.4 Entering User Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
5.4.1 Entering User Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
5.4.2 Entering User-Defined Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71
5.4.3 Entering User Constants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
5.4.4 Entering Saturation Constants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
Chapter 6. Setting Up Communications
6.1 Setting Up moisture.IQ Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
6.2 Configuring the Serial Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
6.3 Configuring the Modbus Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
6.4 Connecting to an Ethernet LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
6.4.1 Configuring the Ethernet TCP/IP Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
6.4.2 Capabilities of the Ethernet Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
6.5 Configuring a VNC Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82
6.6 Configuring the Web Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83
6.7 User Management Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84
6.8 Setting Up a Remote Connection to a PC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85
Chapter 7. Maintenance
7.1 Delta F Oxygen Cell Electrolyte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87
7.1.1 Checking the Electrolyte Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
7.1.2 Replenishing the Electrolyte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
7.2 Replacing and Recalibrating Moisture Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89
7.3 Calibrating the Delta F Oxygen Cell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89
7.3.1 Displaying Oxygen Content in PPMv and μA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89
7.3.2 Checking the Oxygen Cell Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
7.4 Delta F Oxygen Cell Background Gas Correction Factors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91
7.4.1 Correcting for Different Background Gases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91
7.4.2 Entering the Background Gas Correction Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
Chapter 8. Troubleshooting
8.1 Screen Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93
8.2 Common Problems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96

Contents
vi moisture.IQ User’s Manual
Chapter 9. Specifications
9.1 Electronics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99
9.2 Moisture Measurement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
9.3 Temperature Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
9.4 Pressure Measurement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
9.5 Oxygen Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
9.6 General Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
9.7 Output Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
9.8 Input Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
9.9 Probe Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Appendix A. Menu Maps
A.1 The Settings Menu Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
A.2 The Outputs, Alarms and Logger Menu Map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
A.3 The Configuration > Probe & User Menu Maps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
A.4 The Configuration > Comms Menu Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Appendix B. Wiring Diagrams
B.1 Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
B.2 Rear View Channel Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
B.3 Power Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
B.4 RS-485 Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Appendix C. Updating the moisture.IQ Firmware
C.1 Updating the Chassis Firmware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
C.2 Updating the moisture.IQ Module Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Appendix D. Modbus Register Map

moisture.IQ User’s Manual vii
Preface
Product Registration
Thank you for purchasing your moisture.IQ from Baker Hughes, a GE Company. Please register your product at
www.gemeasurement.com/productregistration for product support such as the latest software/firmware
upgrades, product information and special promotions.
Services
BHGE provides customers with an experienced staff of customer support personnel ready to respond to
technical inquiries, as well as other remote and on-site support needs. To complement our broad portfolio of
industry-leading solutions, we offer several types of flexible and scalable support services including: Training,
Product Repairs, Extended Warranties, Service Agreements and more. Please visit
www.gemeasurement.com/services for more details.
Terms and Conditions
Sales Terms and Conditions for your recent purchase of a BHGE product, including the applicable product
Warranty, can be found on our website at the following link:
www.gemeasurement.com/sales-terms-and-conditions
Typographical Conventions
Note: These paragraphs provide information that provides a deeper understanding of the situation, but is not
essential to the proper completion of the instructions.
IMPORTANT: These paragraphs provide information that emphasizes instructions that are essential to proper
setup of the equipment. Failure to follow these instructions carefully may cause unreliable
performance.
Safety Issues
CAUTION! This symbol indicates a risk of potential minorpersonal injury and/or severe damage to the
equipment, unless these instructions are followed carefully.
WARNING! This symbol indicates a risk of potential serious personal injury or death, unless these
instructions are followed carefully.
WARNING! It is the responsibility of the user to make sure all local, county, state and national codes,
regulations, rules and laws related to safety and safe operating conditions are met foreach installation.
Attention European Customers! To meet CE Marking requirements for all units intended for use in
the EU, all electrical cables must be installed as described in this manual.

Preface
viii moisture.IQ User’s Manual
Auxiliary Equipment
Local Safety Standards
The user must make sure that he operates all auxiliary equipment in accordance with local codes, standards,
regulations, or laws applicable to safety.
Working Area
Qualification of Personnel
Make sure that all personnel have manufacturer-approved training applicable to the auxiliary equipment.
Personal Safety Equipment
Make sure that operators and maintenance personnel have all safety equipment applicable to the auxiliary
equipment. Examples include safety glasses, protective headgear, safety shoes, etc.
Unauthorized Operation
Make sure that unauthorized personnel cannot gain access to the operation of the equipment.
WARNING! Auxiliary equipment may have both manual and automatic modes of operation. As
equipment can move suddenly and without warning, do not enterthe work cell of this equipment during
automatic operation, and do not enterthe work envelope of this equipment during manual operation. If
you do, serious injury can result.
WARNING! Make sure that power to the auxiliary equipment is turned OFF and locked out before you
perform maintenance procedures on this equipment.

moisture.IQ User’s Manual ix
Preface
Environmental Compliance
RoHS
The moisture.IQ fully complies with RoHS regulations (Directive 2011/65/EU).
Waste Electrical and Electronic Equipment (WEEE) Directive
BHGE is an active participant in Europe’s Waste Electrical and Electronic Equipment (WEEE) take-back initiative
(Directive 2012/19/EU).
The equipment that you bought has required the extraction and use of natural resources for its production. It
may contain hazardous substances that could impact health and the environment.
In order to avoid the dissemination of those substances in our environment and to diminish the pressure on
the natural resources, we encourage you to use the appropriate take-back systems. Those systems will reuse or
recycle most of the materials of your end life equipment in a sound way.
The crossed-out wheeled bin symbol invites you to use those systems.
If you need more information on the collection, reuse and recycling systems, please contact your local or
regional waste administration.
Please visit http://www.gemeasurement.com/environmental-health-safety-ehs for take-back instructions and
more information about this initiative.

Preface
x moisture.IQ User’s Manual
[no content intended for this page]

moisture.IQ User’s Manual 1
Chapter 1. Installation
Chapter 1. Installation
1.1 Introduction
Users typically install the moisture.IQ as part of a complex process system, which includes components such as
filters, pumps, and pressure regulators. In such an environment, probes and other parts of the system may be
subjected to environmental hazards, such as high temperature, pressure extremes, corrosive elements and
mechanical vibrations.
This section contains information and instructions for installing the moisture.IQ into a process system, while
taking into account all of the above factors. The following section describes how to set up and connect the
moisture.IQ.
If you have questions about the installation procedures, contact our technical support department. See the rear
cover of this manual for contact information.
1.2 Unpacking the moisture.IQ
Before beginning the installation, unpack the unit and make sure all the parts and documentation listed on the
packing slip are included. Be sure to inspect each piece of equipment, including the sample system, for
evidence of mishandling. If anything has been damaged or is missing, report this to the carrier and to BHGE
immediately.
1.3 Installing the moisture.IQ
To install the moisture.IQ, refer to the drawing for your specific configuration (benchtop, rack mount, panel
mount, weatherproof or explosion-proof) in the Certification and Safety Statements at the end of this manual.
WARNING! To ensure the safe operation of this unit, you must install and operate the moisture.IQ as
described in this user’s manual. In addition, be sure to follow all applicable safety codes and regulations
for installing electrical equipment in your area.
WARNING! For Zone 2 Stainless Steel: Do not rub front face with a dry cloth within the hazardous
area as a spark may occur.

Chapter 1. Installation
2 moisture.IQ User’s Manual
1.4 Choosing an Installation Site
You should have discussed environmental and installation factors with a BHGE applications engineer or field
sales person by the time you receive the meter. The equipment provided should be suited to your application
and installation site.
The moisture.IQ is available in rack-mount, bench top, or panel-mount versions that are suitable for most
indoor installations. BHGE also provides weatherproof and explosion-proof housings for outdoor and
hazardous area locations. See the drawings in the Certification and Safety Statements at the end of this manual
for details of each enclosure.
Before installing the unit, read the guidelines below to verify that you have selected the best installation site.
1.4.1 General Site Guidelines
•Choose an installation site for the probes and sample systems that is as close to the process line as
possible. Avoid long lengths of connecting tubing. If long distances are unavoidable, a fast sampling
by-pass loop is recommended. Do not install any other components, such as filters, upstream from the
probes or sample system unless instructed to do so by BHGE.
•Observe all normal safety precautions. Use the probes within their maximum pressure and
temperature ratings.
•Although the moisture.IQ may not need to be accessed during normal operation, install the electronics
unit at a convenient location for programming, testing and servicing. A control room or instrument
shed are typical locations.
•Locate the electronics unit away from high temperatures, strong electrical transients, mechanical
vibrations, corrosive atmospheres, and any other conditions that could damage or interfere with the
meter operation. See Chapter 9. “Specifications” on page 99 for environmental limits.
•Protect the probe cables from excessive physical strain (e.g., bending, pulling, twisting, etc.).
•Observe the proper cable restrictions for the probes. You can locate Moisture Image Series probes up to
915 m (3000 ft) from the electronics unit with unshielded twisted-pair cable. M-Series probes can be
located up to 600 m (2000 ft) from the unit with the use of specially shielded cable.
1.4.2 Low Voltage Directive
If the power mains switch on the unit remains accessible to the user after installation a disconnect device is
not required. However, if installation blocks access to the power mains switch, compliance with the EU Low
Voltage Directive (IEC 61010) requires an external power disconnect device such as a switch or circuit breaker.
The disconnect device must be marked as such, clearly visible, directly accessible, and located within
1.8 m (6 ft) of the unit.

moisture.IQ User’s Manual 3
Chapter 1. Installation
1.5 Moisture Probe Considerations
The M-Series and Moisture Image Series probes consist of an aluminum oxide sensor mounted on a connector
head. Standard probe mounts include a protective stainless steel shield.
The probe sensor materials and housing maximize durability and insure a minimum of water absorbing
surfaces in the vicinity of the aluminum oxide surface. A sintered stainless steel shield is used to protect the
sensor from high flow rates and particulate matter. The end cap should not be removed except upon advice
from BHGE.
The sensor has been designed to withstand normal shock and vibration. You should make sure that the active
sensor surface is never touched or allowed to come into direct contact with foreign objects, since this may
adversely affect performance.
Observing these few simple precautions will result in a long and useful probe life. BHGE recommends that
probe calibration be checked routinely, at 12-month intervals, or as recommended by our applications
engineers for your particular application.
The probe will measure the water vapor pressure in its immediate vicinity. Therefore, readings will be
influenced by its proximity to the system walls, materials of construction, and other environmental factors.The
sensor can be operated under vacuum or pressure and under flowing or static conditions.
See the following sections for the recommended environmental precautions.
1.5.1 Temperature Range
See “Probe Specifications” on page 105, for details.
1.5.2 Moisture Condensation
Be sure the temperature is at least 10°C higher than the dew/frost point temperature. If this condition is not
maintained, moisture condensation could occur on the sensor or in the sample system, which will cause
reading errors. If this happens, dry out the probe following the procedures outlined in BHGE document
#916-064, Basic Hygrometry Principles.
1.5.3 Static or Dynamic Use
The sensor performs equally well in still air or where considerable flow occurs. Its small size makes it ideal for
measuring moisture conditions within completely sealed containers or dry boxes. It will also perform well
under gas flow conditions as high as 10,000 cm/sec and liquid flow conditions up to 10 cm/sec. Refer to BHGE
document #916-064, Basic Hygrometry Principles, for maximum flow rates in gases and liquids.

Chapter 1. Installation
4 moisture.IQ User’s Manual
1.5.4 Pressure Range
The moisture probe always senses the correct water vapor pressure regardless of the total ambient pressure.
The moisture sensor measures water vapor under vacuum or high pressure conditions from as little as a few
microns of Hg to as high as 5000 psi total pressure.
1.5.5 Long-Term Storage & Operational Stability
Sensors are not affected by continuous abrupt humidity changes or damaged by exposure to saturation
conditions even when stored. However, you should store probes in their original shipping containers in a clean,
dry location. If the probe is saturated during storage, refer to “Moisture Condensation” on page 3 before
installing the probe. For best performance, do not store probes longer than one to two years from their
calibration date.
1.5.6 Interference Effects
The sensor is completely unaffected by the presence of a wide variety of gases or organic liquids. Large
concentrations of hydrocarbon gases, Freon, ozone, carbon dioxide, carbon monoxide, and hydrogen have no
effect on sensor water vapor indications. The sensor will operate properly in a multitude of gaseous or
non-conductive liquid environments.
1.5.7 Corrosive Materials
Avoid all materials that are corrosive or otherwise damaging to aluminum or aluminum oxide. These include
strongly acidic or basic materials and primary amines.

moisture.IQ User’s Manual 5
Chapter 1. Installation
1.6 Sample System Guidelines
A sample system is required for oxygen measurement and, although not mandatory, is highly recommended
for moisture measurement. The purpose of a sample system is to condition or control a sample stream to
within the specifications of a probe. The application requirements determine the design of the sample system.
BHGE applications engineers will make recommendations based on the following general guidelines.
1.6.1 Moisture Sample Systems
Typically, sample systems should be kept very simple. They should contain as few components as possible and
all or most of those components should be located downstream of the measurement probe. Figure 1 below
shows an example of a basic sample system consisting of an explosion-proof housing with a sample cell, a
filter, a flow meter, a vent valve, an inlet shut-off valve and an outlet shut-off valve.
The sample system components should not be made of any material that will affect measurements. A sample
system may include a filter to remove particulates from the sample stream or a pressure regulator to reduce or
control the pressure of the stream. However, most common filters and pressure regulators are not suitable for
sample systems because they have wetted parts that may absorb or release components (such as moisture) into
the sample stream. They may also allow ambient contamination to enter the sample stream. In general, you
should use stainless steel construction for all wetted parts. Contact BHGE for further instructions.
Figure 1: A Typical Moisture Sample System
Note: The actual sample system design is dependent on the application requirements.
Sample
Cell
Sample
Inle t
Sample
Outlet
Vent

Chapter 1. Installation
6 moisture.IQ User’s Manual
1.6.2 Oxygen Sample Systems
Oxygen sample systems are required and can be ordered from BHGE for bench or wall mounting. You can also
build your own sample system by using the following guidelines.
IMPORTANT: The BHGE warranty will be voided if the sample system does not have a relief valve.
The basic sample system requirements are as follows (see Figure 2 below):
•The oxygen cell requires a sample gas flow of 0.5 to 1 LPM (1 to 2 SCFH).
•The gas pressure in the sample cell must be between 0.0 and 1.0 psig. The pressure must not exceed
1.0 psig.
•A 10 psig pressure relief valve installed upstream of the oxygen cell is required to prevent
over-pressure.
•A flow meter is required to measure the flow.
•A pressure gauge is required to measure the pressure.
•A flow regulating or needle valve is required and should be located upstream of the sample cell.
•A pressure regulator is required for sample gas supplies of 50 psig or greater.
If a sample pump is required to draw a sample to the oxygen cell, the pump should be installed downstream
from the oxygen cell. You must also install a vacuum relief valve set at 1.0 psig between the oxygen cell and the
pump.
Figure 2: A Typical Oxygen Cell Sample System
Note: The actual sample system design is dependent on the application requirements.
Sample
Inlet
Sample
Outlet

moisture.IQ User’s Manual 7
Chapter 1. Installation
1.7 Mounting the Hygrometer System
Mounting the hygrometer system consists of mounting the electronics unit, the probes, and the sample
systems.
1.7.1 Mounting the Electronics Unit
Use the outline and dimension drawings in the Certification and Safety Statements at the end of this manual to
mount the moisture.IQ. These drawings provide clearance and other mounting dimensions needed to prepare
the site for mounting.
Be sure to follow the guidelines outlined in “Choosing an Installation Site” on page 2 before mounting the
enclosure.
Note: If the installation location does not provide enough room for connections to be made easily after
installation, you may want to make connections to the MIS or M-Series probes, Delta F Oxygen Cell,
Outputs and Alarms before mounting the instrument.
1.7.2 Mounting a Sample System
BHGE sample systems are normally fastened to a metal plate that has four mounting holes. BHGE can also
provide the sample system in an enclosure, if requested. In either case, fasten the sample system plate or
enclosure with bolts in the mounting holes at each of the four corners. If you ordered sample system outline
and dimension drawings, they will be included in your shipment.
Connect the sample system inlet to the process and the outlet to the return, using the appropriate fittings or an
appropriate NPT adapter.
WARNING! If the power mains switch on the unit remains accessible to the user after installation, a
disconnect device is not required. However, if the installation blocks access to the power mains switch,
compliance with the EU's Low Voltage Directive (IEC 61010) requires an external power disconnect
device such as a switch or circuit breaker. The disconnect device must be marked as such, clearly visible,
directly accessible, and located within 1.8 m (6 ft) of the unit.
CAUTION! Do not start a flow through the sample system until all probes and transmitters are
properly installed.

Chapter 1. Installation
8 moisture.IQ User’s Manual
1.7.3 Mounting the Oxygen Cell
If your oxygen cell is not mounted in a sample system, refer to the Figure 3 below for mounting details.
Figure 3: Oxygen Cell Dimensions
5.00
(127.0 MAX)
.40
(6.4)
0.25
0.62
(15.8) (38.1)
1.50
1.05
(26.7) (53.3)
2.10
MIN
MAX
4.91
(124.7)
(71.1)
2.80
outlet
gas
Sample
inlet
gas
Sample
window
level
Electrolyte
reservoir
Electrolyte
(9.4)
0.37
(52.1)
2.05
(31.2)
1.23
(26.9)
1.06
(14.0)
0.55
MIN
MAX
(149.9)
5.90
TEMPERATURE SENSOR
CONN
CONN
SERVOMEX
MAX
Other manuals for moisture.IQ
1
Table of contents
Other GE Measuring Instrument manuals