AEMC Simple Logger II Series User manual

ENGLISH User Manual
TRMS CLAMP-ON • AC CURRENT
AC VOLTAGE • DC CURRENT
DC VOLTAGE • THERMOCOUPLE
TEMP/RH • EVENT LOGGER
Simple Logger®II
Data Loggers
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Statement of Compliance
Chauvin Arnoux®, Inc. d.b.a. AEMC®Instruments
certifies that this instrument has been calibrated
using standards and instruments traceable to
international standards.
We guarantee that at the time of shipping your
instrument has met its published specifications.
An NIST traceable certificate may be
requested at the time of purchase, or obtained
by returning the instrument to our repair and
calibration facility, for a nominal charge.
The recommended calibration interval for this
instrument is 12 months and begins on the date of
receipt by the customer. For recalibration, please
use our calibration services. Refer to our repair
and calibration section at .
Serial #: ________________________________
Catalog #: _______________________________
Model #: ________________________________
Please fill in the appropriate date as indicated:
Date Received: _________________________________
Date Calibration Due: _______________________
Chauvin Arnoux®, Inc.
d.b.a AEMC®Instruments
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

2
Simple Logger®II Series
Table of Contents
1. INTRODUCTION ................................................................................. 4
1.1 Symbols Used...........................................................................5
1.2 DenitionofMeasurementCategories .....................................5
1.3 ReceivingYourShipment..........................................................6
1.4 OrderingInformation.................................................................6
1.4.1 RecommendedProbes:ModelsL101/L102/L562 ........7
1.4.2 RecommendedProbes:ModelL111.............................8
1.4.3 AccessoriesandReplacementParts............................8
2. PRODUCT FEATURES......................................................................... 9
2.1 Description................................................................................9
2.2 ControlFeatures .....................................................................10
2.2.1 StandardModels.........................................................10
2.2.2 Clamp-onModelCL601..............................................12
3. SPECIFICATIONS ............................................................................. 14
4. OPERATION..................................................................................... 26
4.1 LEDControlOperationandStatusFunction ..........................26
4.2 BatteryUse .............................................................................28
4.3 RecordingData.......................................................................29
4.3.1 StartingaRecordingSession .....................................29
4.3.2 StoppingaRecordingSession ...................................29
4.4 DownloadingRecordedData..................................................30
4.5 ClearingAlarmIndication........................................................30
4.6 ErasingDatafromMemory.....................................................30
4.7 DataStorage...........................................................................31
4.7.1 TrendMeasurements..................................................31
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Simple Logger®II Series
3
4.8 LoggerOperation....................................................................32
4.8.1 RecordingwithMemoryCleared ................................32
4.8.2 RecordingwithaPartialorFullMemory.....................32
4.8.3 MemoryFilledDuringRecordingSession ..................33
4.8.4 Batt.PowerInsucientforFullRecordDuration ........33
4.8.5 RecordingSessionhasEnded ...................................34
4.9 EventLoggerOperation(ModelL404) ...................................34
4.9.1 SampleEventCapture................................................35
4.9.2 ApplicationExamples .................................................36
4.10ResetSwitchOperation ..........................................................36
4.11FlashUpgradeSwitches.........................................................37
5. DATAVIEW SOFTWARE..................................................................... 38
5.1 InstallingDataView®................................................................38
5.2SimpleLoggerIIControlPanel ...............................................40
6. MAINTENANCE................................................................................ 41
6.1 ReplacingtheBatteries...........................................................41
6.2 ReplacingtheFuse(ModelL111) ...........................................42
6.3 Cleaning..................................................................................42
APPENDIX A: TROUBLESHOOTING....................................................... 43
APPENDIX B: GLOSSARY..................................................................... 44
Repair and Calibration....................................................................... 45
Technical and Sales Assistance......................................................... 45
Limited Warranty ............................................................................... 46
Warranty Repairs............................................................................... 46
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

4
Simple Logger®II Series
CHAPTER 1
INTRODUCTION
WARNING
TheseinstrumentscomplywithsafetystandardEN61010-1(Ed2-2001)orEN
61010-2-032 (2002) for voltages and categories of installation, at an altitude
below6562ft(2000m)andindoors,withadegreeofpollutionatmostequalto2.
• Do not use in explosive atmosphere or in the presence of ammable
gasesorfumes.
• Donotuseonvoltagenetworksgreaterthancategoriesmentionedabove.
• Observethemaximumvoltagesandintensitiesassignedbetweenterminals
andearth.
• Donotuseitifappearsdamaged,incompleteorimproperlyclosed.
• Beforeeachuse,checktheconditionoftheinsulationofcables,caseand
accessories. Anything which appears damaged (even partially) must be
reportedforrepairorscrapping.
• Useleadsandaccessoriesofvoltagesandcategoriesatleastequaltothose
oftheinstrument.
• Observetheenvironmentalconditionsofuse.
• Useonlyrecommendedfuse. Disconnectallleadsbeforereplacingthe
fuse(L111).
• Do not modify the instrument and use only original replacement parts.
Repairsoradjustmentsmustbeperformedbyauthorizedpersonnel.
• Replacethebatterieswhenthe“LowBat”LEDisblinking. Disconnect
allcablesfromtheinstrumentorremovetheclamponfromthecablebefore
openingtheaccessdoortothebatteries.
• Useprotectiveequipmentwhensecurityconditionsarerequired.
• Keepyourhandsawayfromunusedterminalsofthedevice.
• Whenhandlingprobes,probetips,currentsensorsandalligatorsclips,
keepngersbehindtheguards.
• Formeasurementsofdangerousvoltages,rstconnecttheblackleadtothe
blackterminaloftheinstrumentandthenconnectthisleadtothelowvolt-
agepointofthesourcetomeasure(potentialclosertoEarth).Thenconnect
theredleadtotheredterminaloftheinstrumentandconnecttheleadtothe
hotsourcetomeasure.Disconnectionmustbedonerespectingthereverse
order,rstdisconnectthehotleadandthenredthenblacklead.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Simple Logger®II Series
5
1.1 Symbols Used
Signifies that the instrument is protected by double or reinforced insulation.
CAUTION - Risk of Danger! Indicates a WARNING and that the operator must
refer to the user manual for instructions before operating the instrument in all
cases where this symbol is marked.
Risk of electric shock. The voltage at the parts marked with this symbol may
be dangerous.
Refers to a type A current sensor. This symbol signifies that application around
and removal from HAZARDOUS LIVE conductors is permitted.
Ground/Earth
Important instructions to read and understand completely.
Important information to acknowledge.
Battery
Fuse
USB socket
Compliance with the Low Voltage & Electromagnetic Compatibility European
directives (73/23/CEE & 89/336/CEE)
In the European Union, this product is subject to a separate collection system
for recycling electrical and electronic components In accordance with directive
WEEE 2002/96/EC
1.2 Definition of Measurement Categories
CAT IV: Formeasurementsperformedattheprimaryelectricalsupply
(<1000V)suchasonprimaryovercurrentprotectiondevices,
ripplecontrolunits,ormeters.
CAT III: For measurements performed in the building installation at the
distributionlevelsuchasonhardwiredequipmentinxedinstal-
lationandcircuitbreakers.
CAT II: For measurements performed on circuits directly connected to
theelectricaldistributionsystem(ACsupplywalloutlet).Exam-
ples are measurements on household appliances or portable
tools.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

6
Simple Logger®II Series
1.3 Receiving Your Shipment
Uponreceivingyourshipment,makesurethatthecontentsareconsistent
with the packing list. Notify your distributor of any missing items. If the
equipmentappearstobedamaged,leaclaimimmediatelywiththecarrier
and notify your distributor at once, giving a detailed description of any
damage.Savethedamagedpackingcontainertosubstantiateyourclaim.
1.4 Ordering Information
Simple Logger®II Model CL601...................................... Cat. #2126.01
(1-Channel,TRMSClamp-on600AAC)
Includes USB cable, DataView®software, 2x1.5V AA-cell alkaline batteries and quick start
guide.
Simple Logger®II Model L101 ......................................... Cat. #2126.02
(1-Channel,TRMS0to1VAC)
Includes a USB cable, DataView®software, 2x1.5V AA-cell alkaline batteries and quick start
guide. Probes purchased separately.
Simple Logger®II Model L102 ......................................... Cat. #2126.03
(2-Channel,TRMS0to1VAC)
Includes a USB cable, DataView®software, 2x1.5V AA-cell alkaline batteries and quick start
guide. Probes purchased separately.
Simple Logger®II Model L111.......................................... Cat. #2126.04
(1-Channel,TRMS0to1AAC)
Includes a USB cable, DataView®software, 2x1.5V AA-cell alkaline batteries, one fuse 2A
(250V) and quick start guide. Probes purchased separately.
Simple Logger®II Model L261 ........................................ Cat. #2126.05
(1-Channel,TRMS600VAC/DC)
Includes USB cable, DataView®software, 2x1.5V AA-cell alkaline batteries, one set of leads,
one set of alligator clips and quick start guide.
Simple Logger®II Model L322 ........................................ Cat. #2126.06
(2-Channel,4to20mADC,Current)
Includes USB cable, one 4-position terminal block connector, DataView®software, 2x1.5V
AA-cell alkaline batteries and quick start guide.
Simple Logger®II Model L404 ........................................ Cat. #2126.29
(4-Channel,EventLogger)
Includes USB cable, one 8-position terminal block connector, DataView®software, 2x1.5V
AA-cell alkaline batteries and quick start guide.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Simple Logger®II Series
7
Simple Logger®II Model L432 ........................................ Cat. #2126.07
(2-Channel,DC±100mV / 1V / 10VDC)
Includes USB cable, one 4-position terminal block connector, DataView®software, 2x1.5V
AA alkaline batteries and quick start guide.
Simple Logger®II Model L481 ........................................ Cat. #2126.25
(1-Channel,±850VDC)
Includes USB cable, DataView®software, 2x1.5V AA alkaline batteries, one set of leads, one
set of alligator clips and quick start guide.
Simple Logger®II Model L562 ........................................ Cat. #2126.35
(2-Channel,TRMS600VVoltageInput&1VCurrentProbeInput)
Includes USB cable, DataView®software, 2x1.5V AA alkaline batteries, one set of leads, one
set of alligator clips and quick start guide. Probes purchased separately.
Simple Logger®II Model L642 ........................................ Cat. #2126.08
(2-Channel,TemperatureThermocouple)
Includes USB cable, Thermocouple - Flexible (1M), K Type, -58° to 480° F, DataView®
software, 2x1.5V AA alkaline batteries and quick start guide.
Simple Logger®II Model L702 ........................................ Cat. #2126.09
(2-Channel,Temp/RHLogger)
Includes USB cable, DataView®software, 2x1.5V AA alkaline batteries and quick start guide.
Simple Logger®II Model ML912 ..................................... Cat. #2126.37
(2-Channel,TRMS,MiniFlex®100/1000AAC)
Includes USB cable, DataView®software, 2x1.5V AA alkaline batteries and quick start guide.
1.4.1 Recommended Probes for Models L101, L102 & L562
ACCurrentProbeModelMN261
(24A-100mV/A, 240A-10mV/A, BNC) ............................................. Cat. #2115.82
NOTE: The MN261 current probe should not be used on applications above
10 or 100A (depending on range) when used with either the L101 or L102 data
loggers. Clipping of the input signal could result.
ACCurrentProbeModelSR661
(10A-100mV/A, 100A-10mV/A, 1000A-1mV/A, BNC) .......................... Cat. #2113.49
ACCurrentProbeModelJM861
(30A-10mV/A, 300A-1mV/A, 3000A-0.1mV/A, BNC)........................... Cat. #2110.90
ACCurrentProbeModelMN379
(5A-200mV/A; 100A-10mV/A, Lead)............................................... Cat. #2153.01
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

8
Simple Logger®II Series
1.4.2 Recommended Probes for Model L111
ACCurrentProbeModelMN313
(150A, 1mA/A, Lead).................................................................. Cat. #2116.25
ACCurrentProbeModelSR604
(1000A, 1mA/A, Lead) ................................................................ Cat. #2113.44
ACCurrentProbeModelJM830A
(3000A, .333mA/A, Lead) ............................................................ Cat. #2110.83
ACCurrentProbeModelMN01
(150A, 1mA/A, Lead)..................................................................Cat. #2129.17
ACCurrentProbeModelMN02
(100A, 1mA/A, Lead, 1% Accuracy) ............................................... Cat. #2129.20
1.4.3 Accessories and Replacement Parts
110VOutletAdapterw/4mmBananaPlug .......................... Cat. #2118.49
Thermocouple-Needle(12x5.9"),
KType,-58°to1292°F(ModelL642)................................. Cat. #2126.46
Thermocouple-Flexible(1.2mm),
KType,-58°to480°F(ModelL642)................................... Cat. #2126.47
Fuse-Setof5,2A(250V)FA(ModelL111) ........................ Cat. #2126.48
Replacement-TypeAto5-pinmini-B2MUSBcable ......... Cat. #2126.49
SmallClassicCarryingBag.................................................Cat. #2133.72
Lead-Setof2,color-coded5ftw/color-codedalligatorclips
(Rated600VCATIV,15A)................................................... Cat. #2140.62
Lead-Setof2,color-coded10ftw/color-codedalligatorclips
(Rated600VCATIV,15A)................................................... Cat. #2140.63
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Simple Logger®II Series
9
CHAPTER 2
PRODUCT FEATURES
2.1 Description
The Simple Logger® II Series include one and two channel recording
devices(modeldependent)poweredbyalkalinebatteries.ForACunits,
linetracking isperformedsuch that64samples overoneline cycleare
taken. Frequency tracking is performed over the range of ±2Hz around
the nominal line frequency (50 or 60Hz). Harmonic measurements are
calculatedfromthese64samples(harmonicsareonlyavailablefromthe
SimpleLoggerIIControlPanelwithintheDataView®software).
TheSimpleLogger®IIrecordsatarateofuptoeighttimespersecond
(model dependent). Samples are taken at a user dened storage rate.
Thismeansthattheinput(s)areignoredbetweenmeasurementintervals.
Batteryoperationandcompactsizeallowsforinstallationintightlocations
withouttheneedforexternalpower.AseriesoffrontpanelLEDsprovide
aquickstatusofthelogger’sstateandmemoryusage.
The main advantage of the logger is its ability to perform a variety of
recording tasks with easy and intuitive setup from a computer using
DataView®software.
Analog information on the input is sampled and converted to a digital
value. This digital signal is processed and stored along with scale and
time information. An optically isolated Universal Serial Bus (USB) port
providesforthetransferofdatafromtheinstrument’sinternalmemoryto
thecomputerforanalysis.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

10
Simple Logger®II Series
2.2 Control Features
2.2.1 Standard Models
3
1
2
4
Figure 2-1
1. Input (model dependent)
L101/L102 - BNCInputTermination
L261/L481 - Tworecessed4mmsafetybananajacks
L111 - Tworecessed4mmsafetybananajacksandfuselocation
L322/L432 -One4-positionremovablescrew-typeterminalblock
L404 -One8-positionremovablescrew-typeterminalblock
L562 - BNC/Tworecessed4mmsafetybananajacks
L642 -Twominiaturethermocoupleconnectors
L702 -Temp/RHSensor
ML912 - TwocaptiveMiniFlex®sensors
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Simple Logger®II Series
11
2. Five LED Indicators
TheLEDsontheloggerservetwofunctions:Control Operationand
Status Function.
• The control operation (when holding down the PRESS button) is
indicatedwithtexttotheleftofeachLED.
• Thestatusfunction(whenPRESSisnotbeinghelddown)associ-
atedwitheachLEDisindicatedwithtexttotherightofeachLED.
• Referto§4.1fordetaileddescriptionsofeachLED.
3. Control Button (PRESS)
Thisbuttonmarked“PRESS”selectsthemodeofoperation.Usethis
buttontostartorstoprecordings,erasethememory,clearalarmsand
turntheinstrumentON/OFF.
4. Female Type Mini-B USB Connector
Thisconnectorislocatedonthebottomoftheinstrument.
5. Reset Switch (not shown)
The RESET switch resets the CPU. To access this switch, remove
the battery compartment cover then remove the four screws hold-
ingthe twohalvesof thecasetogether.The resetswitchis located
ontheexposedPCBneartheinputs(referto§4.11).
6. Flash Upgrade Switches (not shown)
Thesetwoswitches(accessiblefromunderthetopcover),theRESET
switchandupgradesoftwareareusedtorecoverfromafailedash
upgradeprocedure(referto§4.12).
WARNING: If the RESET switch is pressed when the logger is recording,
data in memory may be lost.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

12
Simple Logger®II Series
2.2.2 Clamp-on Model CL601
INPUT: 0-600A
AC
600V CAT III
2
1
3
4
Figure 2-2
1. Safety barrier anti-slip guard
Forsafetypurposes,alwaysholdtheprobeundertheguard.
2. Control Button (PRESS)
Thebuttonmarked“PRESS”selectsthemodeofoperation.Usethis
buttontostartorstoprecordings,erasethememoryandclearalarms.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Simple Logger®II Series
13
3. Five LED Indicators
The LEDs on the instrument serve two functions: control operation
andstatusfunction.
• The control operation (function when holding down the PRESS
button)isindicatedwithtexttotheleftofeachLED.
• Thestatusfunction(functionwhenPRESSisnotbeinghelddown)
associatedwitheachLEDisindicatedwithtexttotherightofeach
LED.
• Referto§4.1fordetaileddescriptionsofeachLED.
4. Female Type Mini-B USB Connector
5. Reset Switch (not shown)
TheRESETswitchresetstheCPU.Toaccesstheswitch,removethe
batterycompartmentcover.Theswitchislocatedatthetopleftofthe
batterycompartment(referto§4.11).
6. Flash Upgrade Switches (not shown)
Thesetwoswitches(accessiblefromunderthebatterycompartment),
theRESET switchandupgradesoftwareareusedtorecoverfroma
failedashupgradeprocedure(referto§4.11).
WARNING: If the RESET switch is pressed when the logger is recording,
data in memory may be lost.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

14
Simple Logger®II Series
CHAPTER 3
SPECIFICATIONS
ReferenceConditions:73°F±4.8°F(23°C±3°C),30-50%RH,DCor50/60Hz,noACexternal
magneticeld,DCmagneticeld≤40A/m,centeredconductor,batteryvoltage:3V±10%.
MODEL L101 L102
ELECTRICAL
Channels One Two
Input BNC
Input Level 0 to 1VAC
Accuracy
(50/60Hz)
0 to 10mV unspecified
10 to 50mV: ±(0.5% of Reading +1mV)
50 to 1000mV: ±(0.5% of Reading +0.5mV)
Resolution 0.1mVAC
Maximum Input Voltage*** 5Vrms or ±7.07VPEAK
Input Impedance 800kW
Sample Rate 64 samples/cycle
Storage Rate Programmable from 125ms to 1 per day
Storage Modes Start/Stop, FIFO and Extended Recording Mode*(XRM™), Alarm
Recording Length 15 minutes to 8 weeks, programmable using DataView®
Memory 240,000 measurement (512kB). Recorded data is stored in non-volatile
memory and retained even if battery is low or removed.
Communication USB 2.0 optically isolated
Power Source** 2x1.5V AA (LR6) alkaline batteries
Battery Life 100 hrs to >45 days (dependent on storage rate/recording length)
MECHANICAL
Dimensions 5.38 x 2.75 x 1.28" (136 x 70 x 32mm)
Weight (with battery) 6.4 oz (180g)
Case UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)
ENVIRONMENTAL
Operating Temperature 14° to 122°F (-10° to 50°C)
Storage Temperature -4° to 140°F (-20° to 60°C)
Relative Humidity Up to 85% at 95°F (35°C), Non-condensing
Altitude 6562’ (2000m)
SAFETY & ELECTRO-MAGNETIC COMPATIBILITY
Safety Rating EN 61010-1; 50V CAT III; Pollution Degree 2
Protection Degree IP40
Electro-Magnetic
Compatibility
EN 61326-1; 07/1997 (+A1 10/1998, +A2 09/2001, +A3 05/2004)
CE Approved
Yes
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Simple Logger®II Series
15
MODEL L111
ELECTRICAL
Channels One
Input Two recessed banana jacks
Input Level 0 to 1AAC
Accuracy
(50/60Hz)
0 to 10mA unspecified
10 to 50mA: ±(0.5% of Reading +1mA)
50 to 1000mA: ±(0.5% of Reading +0.5mA)
Resolution 0.1mA
Maximum Input Current*** 1.2A
Input Impedance 1W
Sample Rate 64 samples/cycle
Storage Rate Programmable from 125ms to 1 per day
Storage Modes Start/Stop, FIFO and Extended Recording Mode*(XRM™), Alarm
Recording Length 15 minutes to 8 weeks, programmable using DataView®
Memory 240,000 measurement (512kB).
Recorded data is stored in non-volatile memory and
retained even if battery is low or removed.
Communication USB 2.0 optically isolated
Fuse 2A FA 250V 5x20mm
Power Source** 2x1.5V AA (LR6) alkaline batteries
Battery Life 100 hours to >45 days
(dependent on storage rate/recording length)
MECHANICAL
Dimensions 5.18 x 2.75 x 1.28" (132 x 70 x 32mm)
Weight (with battery) 6.64 oz (188g)
Case UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)
ENVIRONMENTAL
Operating Temperature 14° to 122°F (-10° to 50°C)
Storage Temperature -4° to 140°F (-20° to 60°C)
Relative Humidity Up to 85% at 95°F (35°C), Non-condensing
Altitude 6562’ (2000m)
SAFETY & ELECTRO-MAGNETIC COMPATIBILITY
Safety Rating EN 61010-1; 50V CAT III; Pollution Degree 2
Protection Degree IP40
Electro-Magnetic
Compatibility
EN 61326-1; 07/1997 (+A1 10/1998, +A2 09/2001, +A3 05/2004)
CE Approved Yes
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

16
Simple Logger®II Series
MODEL L261
ELECTRICAL
Channels One
Input Two recessed 4mm safety banana jacks
Input Level 0 to 600VAC/DC
Accuracy
(50/60Hz)
0 to 5V: unspecified
5 to 50V: ±(0.5% of Reading +1V)
50 to 600V: ±(0.5% of Reading +0.5V)
Resolution 0.1V
Maximum Input Voltage*** 1.2 x 600V
Input Impedance 40MW
Sample Rate 64 samples/cycle
Storage Rate Programmable from 125ms to 1 per day
Storage Modes Start/Stop, FIFO and Extended Recording Mode*(XRM™), Alarm
Recording Length 15 minutes to 8 weeks, programmable using DataView®
Memory 240,000 measurement (512 KB). Recorded data is stored in non-volatile
memory and retained even if battery is low or removed.
Communication USB 2.0 optically isolated
Power Source** 2x1.5V AA (LR6) alkaline batteries
Battery Life 100 hours to >45 days
(dependent on storage rate/recording length)
MECHANICAL
Dimensions 4.94 x 2.75 x 1.28" (125 x 70 x 32mm)
Weight (with battery) 6.4 oz (180g)
Case UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)
ENVIRONMENTAL
Operating Temperature 14° to 122°F (-10° to 50°C)
Storage Temperature -4° to 140°F (-20° to 60°C)
Relative Humidity Up to 85% at 95°F (35°C), Non-condensing
Altitude 6562’ (2000m)
SAFETY & ELECTRO-MAGNETIC COMPATIBILITY
Safety Rating EN61010-1; 600V CAT III, 300V CAT IV; Pollution Degree 2
Protection Degree IP40
Electro-Magnetic
Compatibility
EN 61326-1; 07/1997 (+A1 10/1998, +A2 09/2001, +A3 05/2004)
CE Approved Yes
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Simple Logger®II Series
17
MODEL L322
ELECTRICAL
Channels Two
Input One 4-position removable screw-type terminal block
Input Level -20mADC to +20mADC
Accuracy (0.25% of Reading +0.05mA)
Resolution 0.01mA
Maximum Input Current*** ±24mADC
Input Impedance 50W
Sample Rate Maximum of 8 samples taken at storage interval
Storage Rate Programmable from 125ms to 1 per day
Storage Modes Start/Stop, FIFO and Extended Recording Mode*(XRM™), Alarm
Recording Length 15 minutes to 8 weeks, programmable using DataView®
Memory 240,000 measurement (512 KB).
Recorded data is stored in non-volatile memory and
retained even if battery is low or removed.
Communication USB 2.0 optically isolated
Power Source** 2x1.5V AA (LR6) alkaline batteries
Battery Life 100 hours to >45 days
(dependent on storage rate/recording length)
MECHANICAL
Dimensions 5.45 x 2.75 x 1.28" (136 x 70 x 32mm)
Weight (with battery) 6.4 oz (181g)
Case UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)
ENVIRONMENTAL
Operating Temperature 14° to 122°F (-10° to 50°C)
Storage Temperature -4° to 140°F (-20° to 60°C)
Relative Humidity Up to 85% at 95°F (35°C), Non-condensing
Altitude 6562’ (2000m)
SAFETY & ELECTRO-MAGNETIC COMPATIBILITY
Safety Rating EN 61010-1; 50V CAT III; Pollution Degree 2
Protection Degree IP40
Electro-Magnetic
Compatibility
EN 61326-1; 07/1997 (+A1 10/1998, +A2 09/2001, +A3 05/2004)
CE Approved Yes
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

18
Simple Logger®II Series
MODEL L404
ELECTRICAL
Channels Four
Input One 8-position removable screw-type terminal block
Input Level Contact closure, 0 to 5V
Maximum Input Voltage*** 10VDC
Input Impedance >150KW
Sample Rate Maximum of 8 per second
Storage Rate Maximum once every two sample periods (event dependent)
Storage Mode Event Recording(1)
Recording Length 15 minutes to 8 weeks, programmable using DataView®
Memory 50,000 events (512 KB).
Recorded data is stored in non-volatile memory and
retained even if battery is low or removed.
Communication USB 2.0 optically isolated
Power Source** 2x1.5V AA (LR6) alkaline batteries
Battery Life 100 hours to >45 days
(dependent on storage rate/recording length)
MECHANICAL
Dimensions 5.45 x 2.75 x 1.28" (136 x 70 x 32mm)
Weight (with battery) 6.4 oz (181g)
Case Polycarbonate UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)
ENVIRONMENTAL
Operating Temperature 14° to 122°F (-10° to 50°C)
Storage Temperature -4° to 140°F (-20° to 60°C)
Relative Humidity Up to 85% at 95°F (35°C), Non-condensing
Altitude 6562’ (2000m)
SAFETY & ELECTRO-MAGNETIC COMPATIBILITY
Safety Rating EN 61010-1; 50V CAT III; Pollution Degree 2
Protection Degree IP40
CE Approved Yes
(1) This recording mode stores the time and duration of the event, and the channel the event occurred on.
An event occurs when the input falls below 0.7V and ends when it rises above 0.8V. An internal pull up is
provided for contact closure.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Simple Logger®II Series
19
MODEL L432
ELECTRICAL
Channels Two
Input One 4-position removable screw-type terminal block
Input Level
(3 ranges/channel)
Range 1: -100mV to 100mVDC
Range 2: -1V to 1VDC
Range 3: -10V to 10VDC
Accuracy Range 1: ±(0.5% of Reading +1mV)
Range 2: ±(0.5% of Reading +1mV)
Range 3: ±(0.5% of Reading +10mV)
Resolution Range 1: 0.1mV
Range 2: 1mV
Range 3: 10mV
Maximum Input Voltage*** ±(1.2 x Nominal Range)
Input Impedance 100mV/1V: 80kW; 10V: 800kW
Sample Rate Maximum of 8 samples taken at storage interval
Storage Rate Programmable from 125ms to 1 per day
Storage Modes Start/Stop, FIFO and Extended Recording Mode*(XRM™), Alarm
Recording Length 15 minutes to 8 weeks, programmable using DataView®
Memory 240,000 measurement (512 KB). Recorded data is stored in non-volatile
memory and retained even if battery is low or removed.
Communication USB 2.0 optically isolated
Power Source** 2x1.5V AA (LR6) alkaline batteries
Battery Life 100 hours to >45 days
(dependent on storage rate/recording length)
MECHANICAL
Dimensions 5.45 x 2.75 x 1.28" (136 x 70 x 32mm)
Weight (with battery) 6.4 oz (181g)
Case UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)
ENVIRONMENTAL
Operating Temperature 14° to 122°F (-10° to 50°C)
Storage Temperature -4° to 140°F (-20° to 60°C)
Relative Humidity Up to 85% at 95°F (35°C), Non-condensing
Altitude 6562’ (2000m)
SAFETY & ELECTRO-MAGNETIC COMPATIBILITY
Safety Rating EN 61010-1; 50V CAT III; Pollution Degree 2
Protection Degree IP40
Electro-Magnetic
Compatibility
EN 61326-1; 07/1997 (+A1 10/1998, +A2 09/2001, +A3 05/2004)
CE Approved Yes
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
Other manuals for Simple Logger II Series
1
This manual suits for next models
13
Table of contents
Other AEMC Data Logger manuals

AEMC
AEMC Simple Logger II User manual

AEMC
AEMC PEL 102 User manual

AEMC
AEMC PEL 105 User manual

AEMC
AEMC Simple Logger II User manual

AEMC
AEMC Simple Logger II User manual

AEMC
AEMC PEL 102 Use and care manual

AEMC
AEMC PEL 52 User manual

AEMC
AEMC PEL 102 User manual

AEMC
AEMC SENTINEL SDL-V301 User manual

AEMC
AEMC DL-1080 User manual