
Table of Contents
Page
EPM-P Series Power Meters Programming Guide Contents-1
Equipment Operation..................................................................iii
Personal Safety Considerations............................................iii
General Safety Considerations.................................................... iv
User Environment................................................................. iv
About this Guide........................................................................... v
Related Publications..................................................................viii
Power Meter Remote Operation...................................................... 1-1
Introduction................................................................................... 1-2
Configuring the Remote Interface................................................ 1-3
Interface election.................................................................... 1-3
GPIB Address......................................................................... 1-3
RS232/RS422 Configuration.................................................. 1-4
Zeroing and Calibrating the Power Meter .................................. 1-5
Zeroing .................................................................................... 1-5
Calibration.............................................................................. 1-5
Setting the Reference Calibration Factor ............................ 1-7
Making Measurements ................................................................ 1-8
Using MEASure? ................................................................... 1-9
Using the CONFigure Command ......................................... 1-14
Using the Lower Level Commands........................................ 1-23
Making Measurements on Wireless Communication Standards 1-24
Measuring GSM...................................................................... 1-24
Measuring EDGE .................................................................. 1-26
Measuring NADC .................................................................. 1-28
Measuring iDEN .................................................................... 1-31
Measuring Bluetooth.............................................................. 1-33
Measuring cdmaOne .............................................................. 1-35
Measuring W-CDMA.............................................................. 1-37
Measuring cdma2000 ............................................................ 1-39
Using Sensor Calibration Tables ................................................ 1-41
Overview................................................................................. 1-41
Editing Sensor Calibration Tables ....................................... 1-44
Selecting a Sensor Calibration Table ................................... 1-49
Enabling the Sensor Calibration Table System ................... 1-49
Making the Measurement...................................................... 1-50
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com