AI-OPTIC 71739 User manual

CONTENTS
Short Manual 1 Getting to Know AI-Optic Vision Screener.........1
1 Packing list...........................................................................................................1
2 Charging.............................................................................................................. 2
3 Power on and off................................................................................................ 4
4 Screen-off protection.........................................................................................5
5 Product appearance........................................................................................... 6
6 USB port.............................................................................................................. 6
7 Daily use.............................................................................................................. 6
8 Serial number......................................................................................................7
Short Manual 2 Wi-Fi and Settings................................................... 8
1 Wi-Fi.................................................................................................................... 8
2 Settings................................................................................................................ 8
2.1 Language.............................................................................................................9
2.2 Wi-Fi..................................................................................................................... 9
2.3 Factory Settings............................................................................................... 10
2.4 Time and Time Zone........................................................................................ 10
2.5 Referral Criteria................................................................................................ 10
2.6 Screen Off Time................................................................................................11
2.7 System Update................................................................................................. 11
2.8 Machine ID........................................................................................................ 11
2.9 IP Address......................................................................................................... 11
Short Manual 3 Examination Procedure........................................ 12
1 Select a referral criterion..................................................................................12
2 Enter the basic information of the Subject.................................................... 12
3 Prepare the examination environment...........................................................13
4 Check the examination distance..................................................................... 13
5 Start examination..............................................................................................14
6 View examination results................................................................................. 15
7 Operations related to subject information.....................................................16
7.1 Input the information of a new subject.......................................................... 16
7.2 Retrieve the information of an existing subject........................................... 16
7.3 Save or delete data..........................................................................................17
7.4 Exporting Data.................................................................................................. 17

Short Manual 4 Troubleshooting.....................................................19
1 The device cannot be turned on.....................................................................19
2 The device is automatically powered off after power on............................. 19
3 The screen suddenly turns off......................................................................... 19
4 Common reasons for measurement failure................................................... 19
4.1 The image is not clear.................................................................................... 20
4.2 The subject does not look at the camera.................................................... 20
4.3 Glasses are found........................................................................................... 20
4.4 No pupils are found.........................................................................................21
4.5 The brightness value is excessively large................................................... 21
4.6 The measurement is not completed............................................................. 21
4.7 Eyes are closed or blocked............................................................................21

1
Short Manual 1
Getting to Know AI-Optic Vision
Screener
This manual gives a brief introduction to the AI-Optic Vision Screener device.
For more detailed information about the product, such as the product features,
basic operations, technical specifications, and maintenance, service, and
warranty information, refer to the paper user manual included with the product.
You can also download the electronic user manual by visiting www.ai-
optic.com and finding the Support section.
1 Packing list
Once you receive the product, make sure that the packaging is undamaged
and that all contents are accounted for. If the outer packaging is damaged or
anything in the package is missing, contact the AI-Optic Vision Screener
distributor.
Figure 1-1 All items in the AI-Optic Vision Screener box

2
Product Instruction x 1
Type-C power cable x 1
Power adapter X 1
Tripod x 1
AI-Optic Vision Screener x 1
2 Charging
The AI-Optic Vision Screener supports two power modes: Wired mode and
Battery mode.
Wired mode is when the power cable is plugged in and receiving power
from an external power source.
Battery mode is when the device is unplugged from a power source.
Be sure to charge the AI-Optic Vision Screener before using it for the first time.
To charge the battery, plug the Type-C connector into the USB port of the
device and the Type-A connector into the USB port of a power source or
computer.
Figure 1- 2 Charging connection
When the screen displays the charging status icon, your device is being
charged.

3
Figure 1- 3 Charging status
It takes two hours to fully charge the battery, which holds a two hour charge.
When the battery is less than 20%, the system automatically displays a low
battery icon, as shown in Figure 1-4. In this case, plug the Type-C connector
into the USB port of the device to charge the device.
Figure 1- 4 Low battery icon
You can use the device even while it is being charged.

4
3 Power on and off
Power on: Press and hold the power button for 2 seconds to turn on the
device.
Figure 1-5 Position of the power button
Power off: Tap the Power off icon in the navigation bar on the Home screen;
or press and hold the power button for 4 seconds, and tap Yes in the
confirmation dialog box that appears.
Figure 1- 6 Power off button

5
Figure 1- 7 Shutdown confirmation window
If the device does not respond, press and hold the power button for 6 seconds
to force a shut down.
4 Screen-off protection
While the device is on, if it goes unused for 5 minutes, the screen
automatically turns off. To wake it up, just tap anywhere on the screen.
If the device is idle for 10 minutes, the device is automatically powered off. To
use the device, you need to power the device on again.
To change the screen-off protection settings, choose Settings >Screen Off
Time on the Home screen and specify a desired value.
Figure 1- 8 Screen Off Time settings

6
5 Product appearance
The AI-Optic Vision Screener is equipped with a 7-inch display screen, with a
capacitive touch sensor at the rear. To use a specific function, just touch the
corresponding icon on the Home screen. The screen and touch sensor are
protected by a thin glass cover.
6 USB port
The AI-Optic Vision Screener has a USB power port for intended only for
charging, not for data transmission with other devices.
Do not plug any external devices into this USB port. Otherwise, the device
may be damaged.
Figure 1- 9 Position of the USB port
7 Daily use
When you use the AI-Optic Vision Screener, place it in the way shown in
Figure 1-10.

7
Figure 1- 10 Device with the bottom down and camera facing front
During examination, the device takes a series of photos. The subject must
look into the camera; otherwise, the examination could fail.
8 Serial number
The serial number is at the bottom of the product. You will need to provide it in
the event that you need to contact our customer service center.
Figure 1- 11 Serial number at the bottom of the product

8
Short Manual 2 Wi-Fi and Settings
1 Wi-Fi
Once you turn on the power, the system will show a loading screen followed
by a Wi-Fi option screen.
Figure 2- 1 Wi-Fi configuration screen
Select your desired Wi-Fi network, enter the password, and click Connect to
complete the Wi-Fi connection. To change the Wi-Fi settings, choose
Settings >Wi-Fi on the Home screen, select another network, and enter the
password to connect to this network.
2 Settings
Tap Settings on the Home screen to go to the Settings screen.

9
Figure 2- 2 Power off, Settings, Retrieval, Camera, and Home icons on the Home screen
Figure 2- 3 Settings screen
You can tap the Back icon in the lower-left corner to return to the Home
screen.
2.1 Language
On the Settings screen, you can tap Language to change the system
language. The system supports two languages: English and Chinese.
2.2 Wi-Fi
On the Settings screen, tap Wi-Fi to go to the Wi-Fi configuration screen.
Select your desired Wi-Fi network, enter the password, and tap Connect.

10
2.3 Factory Settings
On the Settings screen, you can tap Factory Settings to restore all settings
and configurations to default factory settings.
2.4 Time and Time Zone
After the device is connected to the Wi-Fi, the system time is automatically
updated.
The AI-Optic Vision Screener uses the international standard date format of
YEAR-MONTH-DAY. For example, January 1st 2020 would appear as 2020-
01-01.
The default time zone on the device is UTC+0. To change the time zone, tap
Time Zone on the Settings screen and select the country and the
corresponding time zone. The system automatically updates the time based
on your local time zone.
Figure 2- 4 Time and time zone settings
2.5 Referral Criteria
The AI-Optic Vision Screener features three examination settings: Arnold,
Matta/Silbert, and Arthur2. The default setting is Arnold. The sensitivity and
specificity of the Arnold setting is best suited for a routine examination.
If you are in a medically developed country or region, you can choose
Matta/Silbert. This option is more sensitive and designed for children to
receive an examination.
If you are in a medically underdeveloped country or region, you can choose

11
Arthur2. This option features high specificity and thus helps reduce
unnecessary referrals.
Figure 2- 5 Referral criteria
2.6 Screen Off Time
On the Screen Off Time settings screen, you can set Auto-Timeout and
Auto-Power off. In the Auto-Timeout drop-down list box, tap the down arrow
and select a value as required. In the Auto-Power off drop-down list box, tap
the down arrow and select a value as required.
2.7 System Update
In the system upgrade interface, if you need to check the update, click "Yes",
the machine will check whether there is the latest version in the state of
networking, if there is, you can download and install the latest software.
2.8 Machine ID
Each AI-Optic Vision Screener has a unique ID. You can click Machine ID on
the setting interface and scan the QR code on the screen to obtain the ID.
2.9 IP Address
This is set up before delivery by the manufacturer, and users do not need to
make any operation changes.

12
Short Manual 3 Examination
Procedure
The inspection light source of the AI-Optic Vision Screener is infrared light,
which is safe for human eyes. Infrared light can avoid causing glare and
miosis.
1 Select a referral criterion
The AI-Optic Vision Screener features three examination settings: Arnold,
Matta/Silbert, and Arthur2. The default setting is Arnold. The sensitivity and
specificity of the Arnold setting is best suited for a routine examination.
If you are in a medically developed country or region, you can choose
Matta/Silbert. This option is more sensitive and designed for children to
receive an examination.
If you are in a medically underdeveloped country or region, you can choose
Arthur2.This option features high specificity and thus helps reduce
unnecessary referrals.
2 Enter the basic information of the Subject
Enter the name, gender, and date of birth of the subject.
Figure 3-1 Entering subject information on the Home screen

13
3 Prepare the examination environment
To obtain the correct measurement values, we recommend that you perform
the examination indoors and avoid direct sunlight during the examination. If
the room has lots of windows, try to close as many curtains or blinds as
possible.
The brightness value should be 5 or below. If the value is greater than 5, the
flash cannot be turned on, and you need to reduce the brightness of the
surrounding environment. If the brightness is 5 or below, turn on the flash.
Then, you can start the procedure.
The examination environment must be quiet and free from distraction. The
subject must hold still during the procedure, so make sure that if the patient is
a child that they are able to hold still.
4 Check the examination distance
The recommended examination distance is 3-4 feet away from the device.
First, place the device at eye level of the subject, about 3-4 feet away from
their face.
Figure 3-2 Taking photos
Then, adjust the position of both the device and the subject to make sure that
their eyes are seen on the screen. Move the device back and forth until a
clear corneal reflection point is obtained. Then, you are ready to start the
measurement.

14
Figure 3-3 Clear corneal reflection points on the screen, with the eyebrows and eyelashes
visible
To ensure that results are as accurate as possible, make sure that the subject
looks directly into the device during the examination. The subject should sit up
straight, with the body facing the camera.
Please remove glasses or contact lenses before starting the exam.
5 Start examination
To start the examination, tap the camera icon on the screen.
During shooting, make sure that the camera is oriented vertically, and keep
the camera at eye level of the subject.
Figure 3-4 Orientation of the AI-Optic Vision Screener during shooting

15
In addition, in order to improve the stability and accuracy of the measurement,
we recommend that customers use the included tripod stabilizing device.
Remind the subject to avoid blinking during the examination, otherwise the
examination will fail.
The entire examination process lasts about 5 seconds. After the scan is
completed, a dialog box appears, as shown in Figure 3-5. You can tap Result
to check the examination results.
Figure 3-5 Shooting completed
6 View examination results
After the scan is completed, the examination results will be ready within
approximately 10 seconds. After you tap Result, the name of the subject, the
date of examination, the spherical degrees and cylinder degrees of both eyes,
and the pupillary distance are displayed.
If the examination result is good, the system displays Passed in green, as
shown in Figure 3-6. If any problem is identified, the system displays Referral
Required in red, as shown in Figure 3-7.

16
Figure 3-6 Examination completed, with good examination results
Figure 3-7 Examination completed, with a referral suggestion
After each measurement, you can tap the Home icon to return to the Home
screen.
7 Operations related to subject information
7.1 Input the information of a new subject
You can input the information of a new subject directly on the Home screen.
7.2 Retrieve the information of an existing subject.
Tap the Retrieval icon at the bottom of the Home screen, to go to the retrieval
screen. Enter the name of the subject and verify the date of birth of the
subject, to avoid mistakes caused by duplicate names. After the

17
corresponding name is found, you can view the examination records of the
subject or start a new examination.
Figure 3-8 Retrieving the information of an existing subject and verifying the date of birth
7.3 Save or delete data
Every time an examination is completed, the AI-Optic Vision Screener
automatically saves the examination results by default. To delete a result, tap
the Retrieval icon on the Home screen, enter the name of the subject, find
the corresponding entry, and then delete the result.
Figure 3-9 Deleting the historical record or starting a new examination
7.4 Exporting Data
After the check, if you need to export the data for easy viewing, you can click
the export button in the menu bar below, and then enter the email address to
receive the summary email about the data. You can download it as needed.
Table of contents
Popular Medical Equipment manuals by other brands

Skytrofa
Skytrofa Auto-Injector Quick reference guide

Dentsply Sirona
Dentsply Sirona Intego installation manual

Invacare
Invacare 9630E Styxo Service manual

Albrecht
Albrecht CDS KNEE BRACE FLEXION User instructions

DeRoyal
DeRoyal Element Sport Instructions for use

Otto Bock
Otto Bock 12K110N-50-S Instructions for use