manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Aiphone
  6. •
  7. Intercom System
  8. •
  9. Aiphone IX-SS-2RA User manual

Aiphone IX-SS-2RA User manual

• Read this manual before installation and connection.
Read the "Setting Manual" and "Operation Manual" included on the DVD-ROM that comes with the
Master Station (IX-MV).
• &RQ¿JXUHWKHV\VWHPVHWWLQJVDFFRUGLQJWRWKH6HWWLQJ0DQXDODIWHUFRPSOHWLQJWKHLQVWDOODWLRQ
DQGFRQQHFWLRQ7KHV\VWHPZLOOQRWIXQFWLRQXQOHVVLWKDVEHHQSURSHUO\FRQ¿JXUHG
• After installation, explain to the customer how to use the device, and be sure to provide the
DFFRPSDQ\LQJ'9'520WKDWFDPHZLWKWKH0DVWHU6WDWLRQ,;09
Important
• Perform the installation and connection only after fully understanding this device and the manual.
,OOXVWUDWLRQVXVHGLQWKLVPDQXDOPD\EHGLIIHUHQWIURPWKHDFWXDORQHV
Warning Negligence could result in death or serious injury.
1. Voltage is applied to parts within the
HTXLSPHQW'RQRWWRXFKDQ\SDUWVWKDWDUH
not associated with the installation, wiring,
or connection. Electric shock could result.
Dismantling
or
alteration
2. Do not dismantle or alter the unit.
Fire or electric shock could result.
3. .HHSWKHXQLWDZD\IURPZDWHURUDQ\
other liquid.
Fire or electric shock could result.
4. The unit is not explosion-proof. Do not
LQVWDOORUXVHQHDUJDVHVRUÀDPPDEOH
materials.
Fire or explosion could result.
5. 'RQRWFRQQHFWDQ\WHUPLQDORQWKHXQLW
to an AC power line.
Fire or electric shock could result.
6. 'RQRWSXWDQ\PHWDORUÀDPPDEOH
material into the unit through the
openings.
Fire, electric shock, or unit trouble could
result.
Caution
Negligence could result in injury to people or damage to property.
1. 'RQRWLQVWDOORUPDNHDQ\ZLUH
WHUPLQDWLRQVZKLOHSRZHUVXSSO\LV
plugged in. It can cause electrical shock
or damage to the unit.
2. Before turning on power, make sure
wires are not crossed or shorted. If not,
¿UHRUHOHFWULFVKRFNFRXOGUHVXOW
3. 'RQRWLQVWDOOWKHXQLWLQDQ\RIWKH
following locations. Fire, electric shock,
or unit trouble could result.
• Places under direct sunlight or places
near heating equipment that varies in
temperature.
• Places subject to dust, oil, chemicals,
K\GURJHQVXO¿GHKRWVSULQJ
• Places subject to moisture and
KXPLGLW\H[WUHPHVVXFKDV
bathrooms, cellars, greenhouses, etc.
• Places where the temperature is quite
low, such as inside a refrigerated area
or in front of an air conditioner.
• Places subject to steam or smoke (near
heating or cooking surfaces).
• Where noise generating devices
such as dimmer switches or inverter
HOHFWULFDODSSOLDQFHVDUHFORVHE\
• /RFDWLRQVVXEMHFWWRH[WUHPHO\
SRZHUIXOHOHFWULF¿HOGV
4. When mounting the unit on a wall,
install the unit in a convenient location,
but not where it could be jarred or
EXPSHG,QMXU\FRXOGUHVXOW
5. Do not place or install the unit in the
locations subject to frequent vibration or
LPSDFW,IWKHXQLWIDOOVLQMXU\WRSHRSOH
or damage to the unit could result.
6. Do not run wires between movable
REMHFWVGRRUVZLQGRZVHWF,WPD\
cause malfunction.
7. 'RQRWSXWDQ\WKLQJRQWKHXQLWRUFRYHU
the unit with cloth, etc. Fire or unit
trouble could result.
8. Be sure to perform a call test or check
the chime volume with the handset on
WKHKRRN,I\RXRSHUDWHWKHKRRNVZLWFK
ZLWKWKHKDQGVHWRQ\RXUHDUDVXGGHQ
FDOOHWFPD\DUULYHFDXVLQJGDPDJHWR
\RXUHDU
Installation Manual
This manual includes Product Liability Precautions. Provide this manual to
end user after installation.
IX-DF-2RA(Video Door Station)
IX-SS-2RA(Audio Only Door Station)
Precautions
Introduction
([DPSOHRI6\VWHP&RQÀJXUDWLRQ
Indicators
Refer to the separate "IX-DA & IX-BAOperation Manual" for indicators other than those listed.
:
Light ON
:
Light OFF
Name Status (Pattern)
Explanation
Status
indicator
Red
ÀDVKLQJ
1RUPDOÀDVKLQJ
0.75 sec 0.75 sec
Booting
)DVWÀDVKLQJ
0.25 sec 0.25 sec
Device
error
/RQJLQWHUYDOÀDVKLQJ
0.5 sec 4 sec
Communication
failure
/RQJLUUHJXODUÀDVKLQJ
1 sec 0.25 sec 0.25 sec0.25 sec 0.25 sec 0.25 sec
Firmware
version
upgrading
6KRUWLUUHJXODUÀDVKLQJ
1 sec 0.25 sec0.25 sec 0.25 sec
Initializing
Red
light
6WDQGE\
Part Names and Accessories
LAN
PoE-enabled switch
(third party)
IX Support Tool
(included with IX-MV)
PC
(
third party
)
PoE-enabled switch
(third party)
PoE-enabled switch
(third party)
IX-BAIX-DA
IX-MV Network Video
Recorder
(third party)
Network Camera
(third party)
EMERGENCY
PoE-enabled switch
(third party)
PoE-enabled switch
(third party)
IX-DF-HID*1
IX-DF-P*2
IX-DF
PoE-enabled switch
(third party)
IX-DF-2RA
JNumber of station registrations in address book
Product number Product name
Number of station registrations
in address book
IX-MV Master Station 500 stations
IX-DA, IX-DF, IX-DF-HID-I*1, IX-DF-HID*1,
IX-DF-2RA*1, IX-DF-PI*2, IX-DF-P*2Video Door Station 20 stations*3
IX-BA, IX-SS, IX-SS-2RA*1
$XGLR2QO\'RRU6WDWLRQ
20 stations*3
*11RUWK$PHULFDRQO\
*2Except North America
*32QO\0DVWHU6WDWLRQVFDQEHUHJLVWHUHG0D[
1. $LSKRQHDVVXPHVQRUHVSRQVLELOLW\IRUGDPDJHVDVDUHVXOWRIGHOD\HGRUXQXVDEOHVHUYLFHVZKLFKZHUH
GXHWRIDLOXUHVLQQHWZRUNHTXLSPHQWFRPPXQLFDWLRQVHUYLFHVE\,QWHUQHWDQGFHOOXODUSKRQHFRPSDQLHVOLQH
interruptions, communication failures, or inaccuracies or omissions in the transmission unit.
2. :HZLOOXQGHUQRFRQGLWLRQVEHOLDEOHIRUGDPDJHWKDWRFFXUVGXHWRWKHLQDELOLW\WRFRPPXQLFDWHGXHWR
malfunctions, problems, or operational errors in this product.
3. ,ISHUVRQDOLQIRUPDWLRQOHDNHGE\HDYHVGURSSLQJRUXQDXWKRUL]HGDFFHVVLQWKHFRPPXQLFDWLRQSDWKVRYHU
WKH,QWHUQHWSOHDVHEHDZDUHWKDW$LSKRQHDVVXPHVQRUHVSRQVLELOLW\IRUWKHGDPDJHV
4. :HZLOOXQGHUQRFRQGLWLRQVEHOLDEOHIRUDQ\GDPDJHVRUORVVHVUHVXOWLQJIURPWKLVSURGXFW¶VFRQWHQWVRU
VSHFL¿FDWLRQV
5. 7KLVPDQXDOZDVFUHDWHGE\$LSKRQH&R/WGDOOULJKWVUHVHUYHG&RS\LQJDSDUWRIRUWKLVHQWLUHPDQXDO
ZLWKRXWSULRUSHUPLVVLRQIURP$LSKRQH&R/WGLVVWULFWO\IRUELGGHQ
6. 3OHDVHQRWHWKDWWKLVPDQXDOPD\EHUHYLVHGRUFKDQJHGZLWKRXWSULRUQRWLFH
7. 3OHDVHQRWHWKDWSURGXFWVSHFL¿FDWLRQVPD\EHFKDQJHGIRUWKHVDNHRILPSURYHPHQWZLWKRXWSULRUQRWLFH
8. 3OHDVHEHDZDUHWKDWLWLVWKHFXVWRPHU¶VUHVSRQVLELOLW\WRHQVXUHWKDWWKHLUFRPSXWHULVVHFXUH:HZLOOXQGHU
QRFRQGLWLRQVEHOLDEOHIRUVHFXULW\IDLOXUHV
9. 7KLVV\VWHPLVQRWLQWHQGHGIRUOLIHVXSSRUWRUFULPHSUHYHQWLRQ,WLVMXVWDVXSSOHPHQWDU\PHDQVRI
FRQYH\LQJLQIRUPDWLRQ$LSKRQHZLOOXQGHUQRFRQGLWLRQVEHOLDEOHIRUORVVRIOLIHRUSURSHUW\ZKLFKRFFXUV
ZKLOHWKHV\VWHPLVEHLQJRSHUDWHG
10. .HHSWKHXQLWPRUHWKDQP¶DZD\IURPUDGLRRU79VHW
11. Install the unit in an area that will be accessible for future inspections, repairs, and maintenance.
12. ,IWKHXQLWLVGRZQRUGRHVQRWRSHUDWHSURSHUO\XQSOXJWKHSRZHUVXSSO\RUWXUQRIIWKH32:(5VZLWFKHV
13. ,ILWLVXVHGFORVHWRDFHOOXODUSKRQHWKHXQLWPD\PDOIXQFWLRQ
14. The unit can be damaged if dropped. Handle with care.
15. The unit turns inoperative during power failure.
16. ,QDUHDVZKHUHEURDGFDVWLQJVWDWLRQDQWHQQDVDUHFORVHE\WKHLQWHUFRPV\VWHPPD\EHDIIHFWHGE\UDGLR
IUHTXHQF\LQWHUIHUHQFH
17. $WDJDWHRUSRUFKLOOXPLQDWHGE\DÀXRUHVFHQWODPSWKHSLFWXUHPD\YDU\EXWWKLVLVQRWDPDOIXQFWLRQ
18. ,IVWULSHVRU¿QHSDWWHUQVDUHUHÀHFWHGRXWOLQHVDQGFRORUVVKRZQPD\GLIIHUIURPDFWXDOSHRSOHRU
backgrounds, but this is not a malfunction.
19. :DUPFRORUOLJKWLQJVKLQLQJRQWKHYLGHRGRRUVWDWLRQPD\FKDQJHWKHWLQWRIWKHSLFWXUHRQWKHPRQLWRU
20. :KHQXVLQJÀXRUHVFHQWOLJKWVWRLOOXPLQDWHWKHVFUHHQLWVFRORUVPD\SHULRGLFDOO\FKDQJHFRORUUROOLQJEXW
this is not a malfunction.
21. 7KHXQLWFDVHPD\EHFRPHDZDUPZLWKXVHEXWWKLVLVQRWDXQLWPDOIXQFWLRQ
22. :DUPDLUÀRZLQJIURPLQVLGHPD\LQWHUDFWZLWKWKHWHPSHUDWXUHGLIIHUHQFHLQWKHRXWVLGHDLUWRFDXVH
FRQGHQVDWLRQWRRFFXURQWKHFDPHUDXQLW,WLVUHFRPPHQGHGWKDW\RXEORFNWKHSRLQWVIURPZKLFKZDUPDLU
LVÀRZLQJRXWVXFKDVLQFRPLQJOLQHSRUWVLQRUGHUWRSUHYHQWFRQGHQVDWLRQ
23. .HHSWKHLQWHUFRPZLUHVPRUHWKDQFP¶¶DZD\IURP$&9ZLULQJ$&LQGXFHGQRLVHDQGRU
unit malfunction could result.
24. 'RRUVWDWLRQLVZHDWKHUUHVLVWDQWEXWGRQRWVSUD\KLJKSUHVVXUHZDWHU8QLWWURXEOHFRXOGUHVXOW
25. Due to the nature of the camera built into the Video Door Station, external light and the surrounding
HQYLURQPHQWPD\DIIHFWWKHSURMHFWLRQTXDOLW\RIWKH79PRQLWRUVRSOHDVHDYRLGLQVWDOOLQJLQWKHIROORZLQJ
locations.
Where the background
is white
Where the sky can be seen
in the background
Where direct sunlight
is present
Sky White
wall
Notice
Issue Date : November 2014 FK2122 A P1114 SQ 56142 Printed in Thailand
Call indicator (orange)
Camera
Microphone
Communication
indicator (green)
Speaker
LED for night illumination
Call button
Status indicator (red)
Front panel Main unit Back box
Camera angle adjustment
OHYHU9LGHR'RRU6WDWLRQRQO\
Reset button*
&$7HFDEOH
connections
Option connector input
* Press and hold the reset
button for longer than 1
second, then release to
restart station.
MAC Address
(PHUJHQF\FDOOEXWWRQ
Call indicator (orange)
Microphone
Communication
indicator (green)
Speaker
Call button
Status indicator (red)
(PHUJHQF\FDOOEXWWRQ
IX-DF-2RA IX-SS-2RA
Front View Front View Side View Back View Supplemental
Instructions x1
2-pin connector
for latch reset x1
Accessories included
Installation Manual
(this manual) x1
Option connector
x1
Special screwdriver
x1
Chinese RoHS paper
x1
Special Screw
x4 Back Box
x1
Installation of Door Station
,PDJLQJ5DQJHDQG0RXQWLQJ/RFDWLRQ,;')5$RQO\
JImaging Position Settings
The camera angle can be adjusted up or down (-8°, 0°, +15°) using the camera angle adjustment lever.
Set it to the optimal level.
JWall Mounting
7KHLQGLFDWHGUDQJHLVDJXLGHOLQHWKDWPD\FKDQJHGHSHQGLQJRQWKHLQVWDOODWLRQHQYLURQPHQW
Unit
center Unit
center
Unit
center
Approx. 1,900 mm (6'3")
Approx. 650 mm (2'2")
500
mm
(20")
500
mm
(20")
500
mm
(20")
Approx. 1,250 mm (4'1" )
1,500 mm (5')
Approx. 1,900 mm (6'3")
Approx. 700 mm (2'3")
Approx. 1,200 mm (3'11")
1,300 mm (4'3")
Approx. 1,950 mm (6'5")
Approx. 700 mm (2'3")
150 mm (5")
Approx. 1,250 mm (4'1" )
1,500 mm (5')
Camera angle 0° Camera angle +15°
If lower due to a level difference
Vertical
Horizontal
Camera angle -8°
Approx. 950 mm (3'1")
500mm (20")
:KHQOLJKWHQWHUVWKHFDPHUDWKHPRQLWRUVFUHHQPD\ÀLFNHUEULJKWO\RUWKHVXEMHFWPD\EHFRPHGDUN7U\WRSUHYHQWVWURQJOLJKWLQJIURPHQWHULQJWKH
FDPHUDGLUHFWO\
FCC
7KLVGHYLFHFRPSOLHVZLWK3DUWRIWKH)&&5XOHV2SHUDWLRQLVVXEMHFWWRWKHIROORZLQJWZRFRQGLWLRQVWKLVGHYLFHPD\QRWFDXVHKDUPIXOLQWHUIHUHQFH
DQGWKLVGHYLFHPXVWDFFHSWDQ\LQWHUIHUHQFHUHFHLYHGLQFOXGLQJLQWHUIHUHQFHWKDWPD\FDXVHXQGHVLUHGRSHUDWLRQ
1RWH7KLVHTXLSPHQWKDVEHHQWHVWHGDQGIRXQGWRFRPSO\ZLWKWKHOLPLWVIRUD&ODVV%GLJLWDOGHYLFHSXUVXDQWWR3DUWRIWKH)&&5XOHV
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses,
DQGFDQUDGLDWHUDGLRIUHTXHQF\HQHUJ\DQGLIQRWLQVWDOOHGDQGXVHGLQDFFRUGDQFHZLWKWKHLQVWUXFWLRQVPD\FDXVHKDUPIXOLQWHUIHUHQFHWRUDGLR
communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference
WRUDGLRRUWHOHYLVLRQUHFHSWLRQZKLFKFDQEHGHWHUPLQHGE\WXUQLQJWKHHTXLSPHQWRIIDQGRQWKHQXVHULVHQFRXUDJHGWRWU\WRFRUUHFWWKHLQWHUIHUHQFHE\
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
• &RQVXOWWKHGHDOHURUDQH[SHULHQFHGUDGLR79WHFKQLFLDQIRUKHOS
Connection Precautions
JCable
The cable is not included with the product.
About the CAT5e/6 cable
• Use a straight cable when connecting between equipment.
• 'RQRWXVHD&$7HFDEOHZLWKDEHQGLQJDQJOHRIOHVVWKDQD
25 mm (1”) radius. Aradius of less than 25 mm (1”) could cause a
communication failure.
CAT5e/6 cableCAT5e/6 cable
Radius ≥ 25 mm (1") Radius < 25 mm (1")
• 'RQRWSHHOWKHMDFNHWRIIWKH&$7HFDEOHDQ\PRUHWKDQLV
QHFHVVDU\
• $WWDFKWKH5-PRGXODUSOXJVXVLQJHLWKHU(,$7,$$RU%
Pair4
Pair3
Pair2
Pair1
T568A
Pair4
Pair2
Pair3
Pair1
T568B
1234567812345678
• 8VHWKH/$1WHVWHUWRFRQ¿UPFRQGXFWLRQEHIRUHFRQQHFWLQJWKH
CAT5e/6 cable.
Cable precautions
• Do not use separate conductors or twisted pair cables.
• Do not use an odd number cable.
• 7KH5-FRQQHFWRUZLWKFRYHUFDQQRWEHFRQQHFWHGWR&$7HFDEOH
WHUPLQDOVIRU0DVWHU6WDWLRQRU'RRU6WDWLRQV8VHFDEOHVZLWKRXWFRYHUV
on the connectors.
• 'RQRWSXOOWKH&$7HFDEOHRUDSSO\H[FHVVLYHORDG
:LULQJ&RQQHFWLRQ
IX-BAIX-DA
Door Station
Green
Purple
Blue
Brown
Red
Orange
Yellow
NO
LAN/PoE
10BASE-T
100BASE-TX
CAT5e/6 straight (UTP)
Door Relay*3
(such as the electric lock)
Contact Input*1
Shielded wire
ϕ0.8mm(20AWG)-2C
ϕ0.8mm(20AWG)-2C
Polarized
PoE-enabled switch
100 m (330')
NC
COM
S
SE
P
P
Audio Output*2
(to paging amplifier)
15 m (50')
Connector
Insulate and secure unused wires.
*1&RQWDFW,QSXW6SHFL¿FDWLRQV
Input method )RUP&GU\FRQWDFW12RU1&
Level detection method
Fixed detection time
200 msec or more
Contact resistance 0D[LPXPFORVXUHUHVLVWDQFHȍRUOHVV
0LQLPXPRSHQUHVLVWDQFHNȍRUPRUH
Terminal short-circuit
current
10 mA or less
Voltage between
the terminals DC 5V or less (between open terminals)
*2$XGLR2XWSXW6SHFL¿FDWLRQV
Output impedance ȍ
Output audio level 300 mVrms ȍZKHQWHUPLQDWHG
How to Install How to Connect
Tighten
Special screw x 4
(included)
Front panel with the unit attached
Back box (included)
45 mm
(1-3/4'')
148 mm
(5-13/16'')
281 mm
(11-1/16'')
Mounting height (box center)
GL=1,500 mm (5')
Loosen
Special screwdriver
(included)
Install the back box in the wall, and
1 then connect the CAT5e/6 cable
and option wires to the unit with the
terminal cover open.
Fasten the front panel to the
2back box with the special screws.
Brown
Red
Orange
Yellow
Green
Blue
NO
C
NC
NO
C
NC
Output method )RUP&GU\FRQWDFW12RU1&
Voltage between
the terminals AC 24V, 0.5A (resistive load)
DC 24V, 0.5A (resistive load)
Minimum load (DC): 10 mV, 0.01 mA
*4$X[5HOD\2XWSXW6SHFL¿FDWLRQV
$X[5HOD\
$X[5HOD\
*4
*4
IX-DF-2RA IX-SS-2RA
Output method )RUP&GU\FRQWDFW12RU1&
Voltage between
the terminals AC 24V, 0.5A (resistive load)
DC 24V, 0.5A (resistive load)
0LQLPXPORDG$&'&P9P$
*3'RRU5HOD\2XWSXW6SHFL¿FDWLRQV
Brown
Red Latch Reset
PCB 0.8mm(20AWG)-2C
0.8mm(20AWG)-2C
Camera angle adjustment lever
+15°
0°
-8°
(Back)
*5
Input method 'U\FRQWDFW12
Contact resistance 0D[LPXPFORVXUHUHVLVWDQFHRUOHVV
*5/DWFK5HVHW6SHFL¿FDWLRQV
Terminal short-
circuit current 10mA or less
Voltage between
the terminals DC 5V or less (between open terminals)
Dip Switch “SW2” and Contact Locations
IX-DF-2RA / IX-SS-2RA Supplemental Instructions
Reset Connector “CN7”
Aux Relay 1
• NO - brown
• C - red
• NC - orange
Aux Relay 2
• NO - yellow
• C - green
• NC - blue
Aux Relay Outputs
Option Connector
DIP Switch “SW2”
* &RQWDFW,QSXWDQG2XWSXW6SHFL¿FDWLRQLVVHWWRGHVLUHGVWDWHXVLQJWKH,;6XSSRUW7RROZKLOHSURJUDPPLQJWKHGRRUVWDWLRQ
ON
1234
Call Button Emergency Button Door Release State
Door Relay State
AUX RY1 State
AUX RY2 State
OFF
OFF
OFF
Calling
OFF
OFF
ON
Talking
OFF
ON
ON
Calling
ON
OFF
ON ON
ON
ON
Default Settings:
*Contact Input Set to “Call”
2XWSXW6SHFLÀFDWLRQ Set to “Contact Input Call / Communication State”
DIP SWITCH “SW2” Settings (Relay PCB Dip Switch)
Talking Monitoring
OFF
ON
ON
ON
1234
Door Release Settings:
*Contact Input Set to “Call”
2XWSXW6SHFLÀFDWLRQ Set to “Door Release”
DIP SWITCH “SW2” Settings (Relay PCB Dip Switch)
*Door Release Operation Tone must be set to “Operation sound”.
Call Button Emergency Button Door Release State
Door Relay State
AUX RY1 State
AUX RY2 State OFF
OFF
Calling
OFF
OFF
ON
Talking
OFF
ON ON
Calling
OFF ON ON
ON
Talking Monitoring
OFF
ON
OFF OFF ON*
OFF
ON
1234
Manual Reset Settings:
*Contact Input Set to “Call”
2XWSXW6SHFLÀFDWLRQ Set to “Contact Input Call / Communication State”
DIP SWITCH “SW2” Settings (Relay PCB Dip Switch)
*AUX RY2 remains “ON” (latched) until Reset Connector “CN7” on PCB is shorted.
Call Button Emergency Button Door Release State
Door Relay State
AUX RY1 State
AUX RY2 State
OFF
OFF
OFF
Calling
OFF
OFF
ON
Talking
OFF
ON ON
Calling
ON
OFF ON ON
ON
ON*
Talking Monitoring
OFF
ON
OFF
ON
1234
Optional Settings:
*Contact Input Set to “Call”
2XWSXW6SHFLÀFDWLRQ Set to “Contact Input Call / Communication State”
DIP SWITCH “SW2” Settings (Relay PCB Dip Switch)
Call Button Emergency Button Door Release State
Door Relay State
AUX RY1 State
AUX RY2 State
OFF
OFF
OFF
Calling
OFF
OFF
ON
Talking
OFF
ON
Calling
ON
OFF
ON ON
ON
Talking Monitoring
OFF
ON
OFF OFF OFF
ON
1234
Door Release & Manual Reset Settings:
*Contact Input Set to “Call”
2XWSXW6SHFLÀFDWLRQ Set to “Door Release”
DIP SWITCH “SW2” Settings (Relay PCB Dip Switch)
*Door Release Operation Tone must be set to “Operation sound”.
**AUX RY2 remains “ON” (latched) until Reset Connector “CN7” on PCB is shorted.
Call Button Emergency Button Door Release State
Door Relay State
AUX RY1 State
AUX RY2 State OFF
OFF
Calling
OFF
OFF
ON
Talking
OFF
ON ON
Calling
OFF ON ON
ON**
Talking Monitoring
OFF
ON ON*OFF OFF
OFF
IX-DF-2RA / IX-SS-2RA Supplemental Instructions
IX Support Tool
8VHWKH,;6XSSRUW7RROLQWKH7DEOH9LHZ
7KHXVDJHIRUWKHFRQWDFWLQSXWRIWKHVWDWLRQZLOO
QHHGWREHVHWWRFDOO([SDQGContact / Audio
Output Settings and select Contact InputIURPWKH
PHQXRQWKHOHIW8VHWKHGURSGRZQXQGHU³8VDJH´
and select CallIRUWKHDSSURSULDWHVWDWLRQ¿JXUH
3UHVVWKH8SGDWHEXWWRQWRVDYHFKDQJHV
Figure 1
Figure 2
7KH,;(PHUJHQF\VWDWLRQLVWREHSURJUDPPHGWRFDOOGHVLJQDWHGPDVWHUVYLDWKHUHGPXVKURRPEXWWRQDWDKLJKHUSULRULW\7KH
PXVKURRPEXWWRQFDQFDOOGLIIHUHQWPDVWHUVWKDQWKHVWDQGDUGFDOOEXWWRQFDOOV7KLVSURFHGXUHVKRZVKRZWRVHWXSWKHHPHUJHQF\
FDOOEXWWRQRQO\6WDWLRQ$VVRFLDWLRQIRUDOOVWDWLRQVZLOOQHHGWREHGRQHSULRUWRFRPSOHWLQJWKHVHVWHSV5HIHUWRWKH,;6XSSRUW7RRO
6HWWLQJ0DQXDOIRUFRPSOHWHSURJUDPPLQJLQVWUXFWLRQV
Figure 3
Figure 4
Figure 5
7KHFRQWDFWRXWSXWVSHFL¿FDWLRQVZLOOQHHGWREHVHW
IRUFRQWDFWLQSXWFDOOFRPPXQLFDWLRQVWDWH
Select 2XWSXW6SHFL¿FDWLRQVIURPWKHPHQXRQWKH
OHIW8VHWKHGURSGRZQXQGHU³8VDJH´DQGVHOHFW
Contact Input Call / Communication State IRU
WKHDSSURSULDWHVWDWLRQ¿JXUH3UHVVWKH8SGDWH
EXWWRQWRVDYHFKDQJHV
,QRUGHUIRUWKHPXVKURRPEXWWRQSXVKWREHDEOH
WRFDOOWKHPDVWHUVDGRRUVWDWLRQJURXSZLOOQHHG
WREHFUHDWHG([SDQGFunction SettingsIURPWKH
PHQXRQWKHOHIWDQGVHOHFWContact Input Call
Click on the Open Door Station Group List button
DWWKHWRSRIWKHSDJH¿JXUH
2QFHLQWKHGRRUVWDWLRQJURXSOLVWVFUROOULJKW
to the appropriate door station and use the drop
GRZQWRVHOHFW³8´IRU8QLFDVWRU³0´IRU0XOWLFDVW
IRUHDFKPDVWHUVWDWLRQWKLVGRRUQHHGVWRFDOO,W
LVUHFRPPHQGHGWKDW*URXS'EHVHW¿JXUH
3UHVVWKH8SGDWHEXWWRQWRVDYHFKDQJHV
Select Contact Input CallDJDLQIURPWKHPHQXRQ
WKHOHIW8VLQJWKHGURSGRZQXQGHU*URXS1XPEHU
select the group that was created in the previous
VWHS8VLQJWKHGURSGRZQXQGHU3ULRULW\VHOHFWWKH
SULRULW\OHYHODWZKLFKWKHPXVKURRPEXWWRQLVWR
SODFHDFDOO¿JXUH3UHVVWKH8SGDWHEXWWRQWR
VDYHFKDQJHV
2QFHDOOVWHSVKDYHEHHQFRPSOHWHGWKHGRRUVWDWLRQZLOOQHHGWREHXSGDWHGZLWKWKHQHZVHWWLQJV)URPWKH)LOH0HQXVHOHFW
Upload Settings To Station. &KHFNWKHER[EHVLGHWKHVWDWLRQWKDWKDVEHHQXSGDWHGDQGFOLFN6WDUW8SORDG7KHVWDWXVPHQXZLOO
GLVSOD\WKHUHVXOWRIWKHXSORDG

This manual suits for next models

1

Other Aiphone Intercom System manuals

Aiphone MK-DS User manual

Aiphone

Aiphone MK-DS User manual

Aiphone LAF-3A User manual

Aiphone

Aiphone LAF-3A User manual

Aiphone AH-108 User manual

Aiphone

Aiphone AH-108 User manual

Aiphone DA-1DS User manual

Aiphone

Aiphone DA-1DS User manual

Aiphone IX SERIES Installation guide

Aiphone

Aiphone IX SERIES Installation guide

Aiphone RCX-48CEU/B User manual

Aiphone

Aiphone RCX-48CEU/B User manual

Aiphone IXG Series User manual

Aiphone

Aiphone IXG Series User manual

Aiphone JF-DVF-XP User manual

Aiphone

Aiphone JF-DVF-XP User manual

Aiphone TD-6Z User manual

Aiphone

Aiphone TD-6Z User manual

Aiphone IS-DVF-2RA-FR User manual

Aiphone

Aiphone IS-DVF-2RA-FR User manual

Aiphone MCW-P3 User manual

Aiphone

Aiphone MCW-P3 User manual

Aiphone MC-60/4A User manual

Aiphone

Aiphone MC-60/4A User manual

Aiphone KB-3MRD User manual

Aiphone

Aiphone KB-3MRD User manual

Aiphone PP-MK User manual

Aiphone

Aiphone PP-MK User manual

Aiphone YAZ-90-3 User manual

Aiphone

Aiphone YAZ-90-3 User manual

Aiphone RA-A User manual

Aiphone

Aiphone RA-A User manual

Aiphone AX-DV-XP User manual

Aiphone

Aiphone AX-DV-XP User manual

Aiphone GF System User manual

Aiphone

Aiphone GF System User manual

Aiphone IXG Series User manual

Aiphone

Aiphone IXG Series User manual

Aiphone LEM-1DL/C User manual

Aiphone

Aiphone LEM-1DL/C User manual

Aiphone KB-3MRD User manual

Aiphone

Aiphone KB-3MRD User manual

Aiphone TC-MC User manual

Aiphone

Aiphone TC-MC User manual

Aiphone IE-1AD User manual

Aiphone

Aiphone IE-1AD User manual

Aiphone TD-24H/B Manual

Aiphone

Aiphone TD-24H/B Manual

Popular Intercom System manuals by other brands

TCS PVU14 0-0010 Series Product information

TCS

TCS PVU14 0-0010 Series Product information

Comelit 6701 Technical manual

Comelit

Comelit 6701 Technical manual

Cardo Systems PRO1 user manual

Cardo Systems

Cardo Systems PRO1 user manual

Godrej SeeThru user manual

Godrej

Godrej SeeThru user manual

Akuvox E21 Series Admin guide

Akuvox

Akuvox E21 Series Admin guide

SSS Siedle SET CA 812 Series Product information

SSS Siedle

SSS Siedle SET CA 812 Series Product information

urmet domus modo 1719 Installation and use manual

urmet domus

urmet domus modo 1719 Installation and use manual

Slinex UNIQUE DIRECT Series user manual

Slinex

Slinex UNIQUE DIRECT Series user manual

Alphatech IP BOLD 65 How to configure

Alphatech

Alphatech IP BOLD 65 How to configure

TCS ISH3022-0140 instruction manual

TCS

TCS ISH3022-0140 instruction manual

Viking Electronics K-1270-IP quick start guide

Viking Electronics

Viking Electronics K-1270-IP quick start guide

FunkTronic Major BOS 1a manual

FunkTronic

FunkTronic Major BOS 1a manual

HME Clear-Com HelixNet Partyline user guide

HME

HME Clear-Com HelixNet Partyline user guide

Sigtronics SDB-800 Installation and operating instructions

Sigtronics

Sigtronics SDB-800 Installation and operating instructions

M-E ADF-701 EX operating instructions

M-E

M-E ADF-701 EX operating instructions

ABB i-HD H81365P A Series product manual

ABB

ABB i-HD H81365P A Series product manual

Vimar ELVOX 69RH Installer's guide

Vimar

Vimar ELVOX 69RH Installer's guide

Mobotix T24S System manual

Mobotix

Mobotix T24S System manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.