LDC
Aiphone Communication Systems • 1700 130th Ave. N.E. • Bellevue, WA 98005
(425) 455-0510 • FAX: (425) 455-0071 • (800) 692-0200 • www.aiphone.com
- 26 -
Door Com Door Entry System
DESCRIPTION:
TheLDCDoorComsystemprovideschimeand
dooransweringforonedoorwithuptosixinside
stations. The LDC-S set comes complete for a
systemwiththreeinsidestations,withtheability
to add up to three additional LDC-1C stations.
A chime sounds through all the inside stations
when a visitor calls, answered from any inside
station.Adoorreleasebuttonis included toopen
adoororgate.Communicatetoallroomsinside
with the one-touch All Call feature.
FEATURES:
• One door with chime and hands free communication
• Up to six inside stations
• Monitor entry area from any inside station
• Door or gate release from each inside station
• All Call to other inside stations from any master
• Mute control to cut off station from receiving All Call
• Chime volume is adjustable, and can be turned off
• Voice volume control
• Easy common wiring, 2 wires to door, 7 wires inside
SPECIFICATIONS:
Power Source: 12V AC, 830mA. Use PT-1210N transformer
Current consumption: Maximum 300mA per station
Communication Output:
800mW at 20Ω(receive); 500mW at 20Ω (transmit)
Calling: 2-stroke chime when called from door station
Communication: Hands free at door station. Push-to-talk at inside station.
Wiring: LE-D to ACC-3: 2 conductor, shielded. Use Aiphone wire #822202.
ACC-3 to LDC-1C’s: 7 conductors (8 conductors with door release) looped.
Use Aiphone wire #822210.
Wiring Distance: 650’ with 22AWG; 1600’ with 18AWG.
Mounting: LDC-1C: Semi-flush. Cut into wall (6-1/8” x 3-3/4”), or rough in BBX-1E backbox.
ACC-3 and LE-D: Surface mount to 1-gang box or ring.
Dimensions (HxWxD): LE-D: 4-3/4” x 3-1/2” x 1-1/8“
ACC-3: 6-1/4” x 6” x 1-3/4”
LDC-1C: 8-1/4” x 6-1/8” x 1-3/8” (outer dimensions)
LDC-S
SOME APPLICATIONS:
• Residences
• Small offices
• Medical offices or clinics
LDC Door Com Door Entry System
- 27 -
ARCHITECTS/ENGINEERS’ SPECIFICATIONS:
The intercom system shall provide door answering for one
door by up to six inside stations. System shall be Aiphone
LDC series. Door station shall be available in surface or flush
mount styles,a nd shall be weather resistant. Flush mount
door station shall be available with stainless steel, brass, or
antiquebrass finish. Insidestations shall besemi-flush mount
style with Talk, All Call, Door Release, and Mute buttons.
User shall be able to adjust chime and All Call volume at
each unit.
Door call-in shall ring a 2-stroke chime at all inside stations,
answered by pressing TALK at any inside station.
Communication at the inside stations shall be push-to-talk,
release-to-listen, and hands free at the door location.
SPECIAL ORDER PRODUCTS:
LDC-S Door Com Set, includes LE-D,
ACC-3, 3 LDC-1C, PT-1210N
Inside Station
LDC-1C Master station, semi-flush mount.
Includes Talk, Off, Door Release,
All Call, Mute, Voice volume, and
Chime volume controls
Accessories
ACC-3 Chime and All Call adaptor.
Includes Chime and All Call
master volume control.
STANDARD PRODUCTS:
Door Stations
LE-D Surface mount door station
LE-DA Flush mount stainless steel door stn.
LE-DA-BR Flush door stn. with brass cover
LE-DA-AB Flush door stn., antique brass cover
Accessories
PT-1210N 12V AC transformer, 1 per system
RY-PA Relay for door release
EL-9S Electric door strike (for wood framed
doors only)
#243340 Optional surface mount back case
for LDC-1C (spare part)
LDC (2)
SYSTEM LAYOUT EXAMPLE:
Internal communication shall be accomplished by pressing
the All Call button and speaking. A person may reply from
another inside station by pressing their All Call button. All
stations in the system shall receive the All Call
announcement unless their Mute button is pressed.
System adaptor shall provide chime from door, amplification
for All Call, power input, and a master volume control.
Wiring shall be 2 conductors from the door station to the
adaptor, and 7 common conductors between inside stations.
A separate 2 conductor wire shall be run from the adaptor
to the door location to activate a door opening mechanism.
System shall be manufactured by Aiphone.
LDC-1C LDC-1C
ACC-3 LDC-1C
LE-D
2888
LDC-1C LDC-1C LDC-1C
88
8
Optional door strike
RY-PA
PT-1210N

This manual suits for next models

1

Other Aiphone Intercom System manuals

Aiphone DE-UR User manual

Aiphone

Aiphone DE-UR User manual

Aiphone IS SERIES User manual

Aiphone

Aiphone IS SERIES User manual

Aiphone MC-U User manual

Aiphone

Aiphone MC-U User manual

Aiphone MA-1A User manual

Aiphone

Aiphone MA-1A User manual

Aiphone MK-DS User manual

Aiphone

Aiphone MK-DS User manual

Aiphone GT-1A User manual

Aiphone

Aiphone GT-1A User manual

Aiphone NDR-LD User manual

Aiphone

Aiphone NDR-LD User manual

Aiphone DA-1MD User manual

Aiphone

Aiphone DA-1MD User manual

Aiphone IXG System User manual

Aiphone

Aiphone IXG System User manual

Aiphone LDC-S/A User manual

Aiphone

Aiphone LDC-S/A User manual

Aiphone KB-DAR-M User manual

Aiphone

Aiphone KB-DAR-M User manual

Aiphone GF-1MDK User manual

Aiphone

Aiphone GF-1MDK User manual

Aiphone TB-nM/D Manual

Aiphone

Aiphone TB-nM/D Manual

Aiphone IE-1GD User manual

Aiphone

Aiphone IE-1GD User manual

Aiphone GH SERIES 0207 AIC User manual

Aiphone

Aiphone GH SERIES 0207 AIC User manual

Aiphone MC-3B User manual

Aiphone

Aiphone MC-3B User manual

Aiphone NCH-2 User manual

Aiphone

Aiphone NCH-2 User manual

Aiphone KBW-M User manual

Aiphone

Aiphone KBW-M User manual

Aiphone AX-DV-P User manual

Aiphone

Aiphone AX-DV-P User manual

Aiphone AP-10M User manual

Aiphone

Aiphone AP-10M User manual

Aiphone IS SERIES Operating instructions

Aiphone

Aiphone IS SERIES Operating instructions

Aiphone NEM-10 User manual

Aiphone

Aiphone NEM-10 User manual

Aiphone MK-1MD User manual

Aiphone

Aiphone MK-1MD User manual

Aiphone MK-DGV User manual

Aiphone

Aiphone MK-DGV User manual

Popular Intercom System manuals by other brands

KOCOM KIP-304 user manual

KOCOM

KOCOM KIP-304 user manual

Viking E-35-IP product manual

Viking

Viking E-35-IP product manual

Bticino PIVOT Technical data

Bticino

Bticino PIVOT Technical data

KOCOM KLP-305 series Operating & installation manual

KOCOM

KOCOM KLP-305 series Operating & installation manual

golmar PE-90-MS/6 quick start guide

golmar

golmar PE-90-MS/6 quick start guide

Fermax Cityline Installer manual

Fermax

Fermax Cityline Installer manual

Sygonix 1698497 operating instructions

Sygonix

Sygonix 1698497 operating instructions

Telex Audiocom IFB-1000 operating instructions

Telex

Telex Audiocom IFB-1000 operating instructions

Telex BTR-24 operating manual

Telex

Telex BTR-24 operating manual

Avidsen ELIA manual

Avidsen

Avidsen ELIA manual

DORANI C10 QUICK APARTMENT SETUP GUIDE

DORANI

DORANI C10 QUICK APARTMENT SETUP GUIDE

Vimar Elvox 7200 Series user guide

Vimar

Vimar Elvox 7200 Series user guide

Vimar ELVOX 0002/841.05 Installer's guide

Vimar

Vimar ELVOX 0002/841.05 Installer's guide

2N Helios IP Configuration manual

2N

2N Helios IP Configuration manual

Genway WL-03NL user manual

Genway

Genway WL-03NL user manual

Midland BTX1 quick start guide

Midland

Midland BTX1 quick start guide

Pentatech VT 81 Operating and safety instructions

Pentatech

Pentatech VT 81 Operating and safety instructions

IDTECK Star RFK101 user manual

IDTECK

IDTECK Star RFK101 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.