SPECIFICATIONS:
Power source: 12V DC, 300mA per station.
Use PS-1225UL
Output: 800mW @ 20 ohms (reception),
500mW @ 20 ohms (transmission)
Communication: Press-to-talk, release-to-listen at
master station. Hands free response.
Talk channel: 1 talkpath. Occupied LED when in use.
Capacity: Up to 4 stations, intermixable
Wiring: 5 common wires (E, R, Y, +, -), plus 1
individual wire per station, looped.
All Call: 3 add’l common wires (P1~P3).
Sub stations: 2 wires homerun in
1-master system only, or 2 common
wires (E, -), plus 1 individual wire per
station, looped or homerun.
Wiring Distance: 650’ w/22AWG; 1600’ w/18AWG
Speaker sensitivity: 40dB
Total Harmonic
Distortion: Less than 5% at rated output power
Signal to Noise
Ratio: 60dB
Frequency Response: -3dB, 770-6800Hz.
Dimensions LEF-3C
(H x W x D): 8-1/4” x 6-1/8” x 1-3/8”
ARCHITECTS/ENGINEERS’ SPECIFICATIONS:
The intercom system shall be of an open voice,
selective calling type with selector switches for each
station. System shall be fully intermixable with other
LEF-series masters or sub stations. Master station
shall be simplex operation, with hands free reply from
the responding station.
Master station shall be equipped with station selector
switches, OFF button for standby mode, TALK button
for simplex operation, and PRIV (privacy) button to
block unauthorized monitoring. An All Call button
shall be provided for initiation of an announcement
throughout the system when the All Call Adaptor is
included in the system. Voice volume control shall
adjust transmit and receive volume at the calling
master station, and a call tone volume control shall
be located beneath the operation plate. A call from a
sub or door shall be annunciated by a momentary
electronic call tone, and the corresponding station
LED shall light for approximately 20 seconds. The
LED shall not light if a master station calls another
master station. LEDs above selector buttons shall
illuminate when the station button is pressed at the
calling master. The Occupied LED shall light to
indicate that the system is in use, and the Off LED
shall light on the unit that has a station selected.
Master station shall flush mount into a wall. An
optional backbox (BBX-1E) shall be available for
ease of installation. Sub stations shall be available
in the following configurations: (1) surface or flush
mount styles, with or without privacy; (2) surface
mount with three call buttons, with or without privacy;
(3) weather resistant door stations in surface or flush
mount styles, mounted on or in standard 1-gang or
2-gang boxes; and (4) vandal proof style, indoor or
outdoor models.
Optional equipment shall be available to provide
chime from up to three door stations, All Call from a
master station, and background music distribution
to all or selected sub or master stations in the system.
Wiring shall be multiple conductors with an overall
shield inside a single jacket, including eight (8)
common wires, plus one (1) individual wire per
station in the system between masters. Maximum
12 conductors. Wiring to sub stations shall be two
(2) conductors in a 1-master system, or three (3)
conductors in a system with two or more masters,
or when All Call is included.
Manufacturer must have earned ISO 9001
certification for quality standards.
Aiphone Communication Systems • 1700 130th Ave. NE • Bellevue, WA 98005
(425) 455-0510 • FAX: (425) 455-0071 • (800) 692-0200 • http://www.aiphone.com
Intercom Solutions For
Communications and Security
153 (6-1/8”)
208 (8-1/4”)
LEF-3C-SS 92326 1104