manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Aiphone
  6. •
  7. Intercom System
  8. •
  9. Aiphone LEM-1DL/C User manual

Aiphone LEM-1DL/C User manual

Other manuals for LEM-1DL/C

4

Other Aiphone Intercom System manuals

Aiphone AX SERIES User manual

Aiphone

Aiphone AX SERIES User manual

Aiphone IS SERIES Manual

Aiphone

Aiphone IS SERIES Manual

Aiphone JK-1HD User manual

Aiphone

Aiphone JK-1HD User manual

Aiphone TB-10T User manual

Aiphone

Aiphone TB-10T User manual

Aiphone LEF-3 User manual

Aiphone

Aiphone LEF-3 User manual

Aiphone HM-7 User manual

Aiphone

Aiphone HM-7 User manual

Aiphone JF User manual

Aiphone

Aiphone JF User manual

Aiphone LAM-1 User manual

Aiphone

Aiphone LAM-1 User manual

Aiphone LAF-10B User manual

Aiphone

Aiphone LAF-10B User manual

Aiphone LA-B User manual

Aiphone

Aiphone LA-B User manual

Aiphone MYW-P1L User manual

Aiphone

Aiphone MYW-P1L User manual

Aiphone MYW-P10L User manual

Aiphone

Aiphone MYW-P10L User manual

Aiphone IX-SS-2RA User manual

Aiphone

Aiphone IX-SS-2RA User manual

Aiphone TC-NMD TC-10MD Owner's manual

Aiphone

Aiphone TC-NMD TC-10MD Owner's manual

Aiphone Ra-D User manual

Aiphone

Aiphone Ra-D User manual

Aiphone JKW-IP User manual

Aiphone

Aiphone JKW-IP User manual

Aiphone CHIME-COM C-123L/A User manual

Aiphone

Aiphone CHIME-COM C-123L/A User manual

Aiphone AH-108 User manual

Aiphone

Aiphone AH-108 User manual

Aiphone Jb-Da User manual

Aiphone

Aiphone Jb-Da User manual

Aiphone GHV-DES/A User manual

Aiphone

Aiphone GHV-DES/A User manual

Aiphone LAF-10S User manual

Aiphone

Aiphone LAF-10S User manual

Aiphone JK-1HD User manual

Aiphone

Aiphone JK-1HD User manual

Aiphone MFH-UB User manual

Aiphone

Aiphone MFH-UB User manual

Aiphone LEM-1DL/C User manual

Aiphone

Aiphone LEM-1DL/C User manual

Popular Intercom System manuals by other brands

Videx VRDK1 (25H) Technical manual

Videx

Videx VRDK1 (25H) Technical manual

Auta COMPACT VISUALTECH manual

Auta

Auta COMPACT VISUALTECH manual

Comelit 4893M Technical manual

Comelit

Comelit 4893M Technical manual

MGL Avionics V16 manual

MGL Avionics

MGL Avionics V16 manual

SSS Siedle BVI 750-0 Installation & programming

SSS Siedle

SSS Siedle BVI 750-0 Installation & programming

urmet domus AIKO 1716/1 quick start guide

urmet domus

urmet domus AIKO 1716/1 quick start guide

urmet domus IPerVoice 1039 Installation

urmet domus

urmet domus IPerVoice 1039 Installation

Alpha Communications STR QwikBus TT33-2 Installation, programming, and  user's manual

Alpha Communications

Alpha Communications STR QwikBus TT33-2 Installation, programming, and user's manual

Monacor ICM-20H instruction manual

Monacor

Monacor ICM-20H instruction manual

Logenex A202CR Installation & programming

Logenex

Logenex A202CR Installation & programming

Quantum QR5 Installation and programming manual

Quantum

Quantum QR5 Installation and programming manual

EVGA XR1 quick guide

EVGA

EVGA XR1 quick guide

CyberData 011211 series Installation quick reference

CyberData

CyberData 011211 series Installation quick reference

Vidos duo M1021 user manual

Vidos

Vidos duo M1021 user manual

Savant DOR-SMS-00 Deployment guide

Savant

Savant DOR-SMS-00 Deployment guide

SSS Siedle BTSV 850-03 operating instructions

SSS Siedle

SSS Siedle BTSV 850-03 operating instructions

Dahua VTO Series quick start guide

Dahua

Dahua VTO Series quick start guide

Elvox 5651 Wiring instructions

Elvox

Elvox 5651 Wiring instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

LEM-1DL/C
Aiphone Communication Systems • 1700 130th Ave. N.E. • Bellevue, WA 98005
(425) 455-0510 • FAX: (425) 455-0071 • (800) 692-0200 • www.aiphone.com
- 28 -
Multi-Master Door Answering System
DESCRIPTION:
TheLEM-1DL/Cisacompactmasterstationable
toansweradoorstation andactivatea doorstrike.
Up to six master stations can be used to answer
the same door. The master has a TALK, OFF and
door release button, as well as volume controls
for voice communication and incoming call tone.
Communication is push-to-talk, release-to-listen
at the master, and hands free at the door station.
Any remote station compatible with the LEM or
LEF series can be used. There is no master-to-
master communication. The unit can be mounted
on a wall or placed on a desk or counter.
NOTE: No master-to-master communication.
SOME APPLICATIONS:
• Offices
• Courthouses
• Hotel/Motel door entry
• Retail/Convenience Stores
• Small Secured Facilities
FEATURES:
• One door station and up to six master stations
• Occupied lamp indicating another master is in use
• Door release button
• Normally Open door release contacts can be modified
to Normally Closed for use with a magnetic lock
• Voice and call tone volume controls
•Desk or wall mount
• Any “LE- or “LS-” series remote can be used
SPECIFICATIONS:
Power: 12-16V AC. Use PT-1210N (12VAC, 10VA) or equivalent
Consumption: Max. 4W (16VAC), Max. 200mA (24VDC)
Output: 100mW at 20Ω
Calling: Mono-electronic tone during call-in from sub
Communication:
Push-to-talk at master, hands free at remote
Mounting: Desk or wall mount
Door Release: Normally open dry contact, Max. 30VAC, 1A or 30VDC, 1A
Wiring: 2 conductors to door station (#822202), 3 conductors between masters (#822203)
Door release: Separate 2 conductor cable between masters and to strike (#822202)
Wiring Distance:
650’ with 22AWG; 1600’ with 18AWG.
Dimensions: 7”H x 5-1/2”W x 2-1/4”D
LEM-1DL/C
LEM-1DL/C Multi-Master Door Answering System
- 29 -
ARCHITECTS/ENGINEERS’ SPECIFICATIONS:
The intercom system shall be of an open voice, selective
calling type with one channel for communication to a remote
station. Up to six master stations shall be able to be
connected, each answering the remote, and requiring their
own power source. Distance from the door to the last master
station shall be within the specified limitations.
A call signal from a remote station shall activate a call tone
on the master stations. The call tone shall last as long as the
call button is being pressed on the remote. Any master shall
be able to answer by pressing the “TALK” button, holding
the “TALK” button to transmit, and releasing to listen. The
person at the remote station speaks hands free.
SPECIAL ORDER PRODUCTS:
Master Station
LEM-1DL/C Master station w/ occupied LED
Sub Stations
LS-NVP/A Vandal proof, weather resistant
sub station
STANDARD PRODUCTS:
Sub Stations
LE-D Door station, surface mount
LE-DA Door station, flush stainless steel
AH-108 10W 8 ohm horn w/ built-in capacitor
Accessories
NP-B Call button for use with AH-108
NP-W Surface mount box for NP-B
RY-AC External signaling relay
(Req’s 12VDC power)
SBX-NVP Surface mount box for LS-NVP/A
EL-9S Electric door strike
PT-1210N 12V AC, 10VA power supply,
1 per master (and for EL-9S)
There shall be no master-to-master communication.
Master station shall be equipped with a door release button,
providinga normally open contact.Othercontrols shall include
TALK and OFF buttons, voice and call tone volume controls.
An “Occupied” LED shall indicate if the system is in use.
Compatible remote stations shall include surface or flush
mount styles, indoor or outdoor stations, and vandal proof
stations.
System shall be manufactured by Aiphone.
LEM-1DL/C (2)
SYSTEM LAYOUT EXAMPLE:
LEM-1DL/C
LE-D
DoorStrike
LEM-1DL/C
3
2
2
2
22
PT-1210N
PT-1210N