Aiphone TB-10T User manual

®
AlPHONE
832883
0
7
88
®
INTERNAL
TELEPHONE
SYSTEM
MODELS:
TB-1OT
(lO-call
master)
TB-20T
(20
•call
master)
-
INSTRUCTIONS
-
NAMES
AND
FUNCTIONS
1.
Handset
2.
Power
lamp
3.
Power
switch
4.
Communication
lamp
5.
OFF
(Cancel)
button
6.
Selector
button
7.
Annunciator
lamp
8.
Terminal
block
(on
back
of
cabinet)
9.
Tone
volume
control
(on
panel)
10.
Selection
lamp
11.
Directory
card
12.
AC
plug
FEATURES
1.
Tone
&
lamp
anunciation
on
calling.
2.
Telephone
sub
station
with
automatic
call
in.
3.
Door
station
&
adaptor
available.
4.
Warning
tone
to
indicate
master
has
not
been
cleared.
5.
Two
msaters
per
system.
6.
Various
combinations
of
conversation:
A.
Master
to
master
B.
Master
to
sub
C.
Sub
to
sub
through
master
D.
One
master
to
sub
of
second
master
7.
Wall-mountable
master
station.
8.
Call
extension
speaker
available.
9.
One
paging
zone
in
lieu
of
one
sub
station
may
be
installed.
SPECIFICATIONS
*
POWER
SOURCE:
*
POWER
CONSUMPTION:
*
CAPACITY:
*
WIRING:
*
PAGING:
ACllOV,
AC120V,
AC125V,
AC220V,
AC240V,
50/60Hz.
5.0W
maximum
10
&
20
station
masters
20
&
40
station
additional
selectors
2
conductors
per
sub
(Non-polarized),
3
conductors
between
masters
5
conductors
to
additional
selector
(using
the
included
connector)
3
conductors
to
door
station
adaptor
(2
common
and
1
individual)
2
conductors
from
door
station
adaptor
to
door
station
(Non-polarized)
Use
PA-T
paging
adaptor
in
conjunction
with
AlPHONE
standard
Paging
Amplifier
Models:
PG-lOB,
PG-30B
or
PG-60B
(PG-lOA,
PG-30A
or
PG-60A
in
North
America)
and
speakers.
-
1
-

BEFORE
YOU
INSTALL
AND
OPERATE
THE
EQUIPMENT
-
Prohibitions
and
precautions-
*
Operation;
1.
D
O
NOT
HOLD
HOOK
SWITCH
DOWN
WHILE
PICKING
UP
HANDSET.
THE
CALL
TONE
SOUNDS
THRU
THE
HANDSET
RECEIVER
ELEMENT
AND
COULD
CAUSE
HEARING
DAMAGE.
*
Installation;
1.
DO
NOT
CONNECT
ANY
TERMINAL
ON
ANY
UNIT
TO
AC
POWER
LINES.
2.
Be
sure
to
remove
plug
of
power
supply
from
AC
outlet
before
you
open
the
unit
or
make
wiring
connections.
3.
Avoid
running
the
connecting
wires
thru
doors,
windows
or
between
furniture,
which
may
pinch
and
disconnectect
the
wires.
4.
The
intercom
equipment
must
be
installed
in
as
dry
and
dust-free
environment
as
possible.
*
Maintenance;
1.
Clean
your
intercom
equipment
with
a
soft
cloth
dampened
with
neutral
household
cleanser.
Never
use
thinner
nor
benzine,
etc.
2.
Do
not
splash
water
on
the
door
station
by
hose,
etc.
NEVER
COMPONENTS
AVAILABLE
FOR
USE
IN
THE
TB-T
SYSTEM
TB-IOT:
10-call
master.
TB-20T:
20-catl
master.
TB-20AS:
Add-on
selector
for
20
additional
sub
stations.
TB-40AS:
Add-on
selector
for
40
additional
sub
stations.
TB-RC:
Substation.
TB-RC
(R):
Sub
station
with
red
case.
ICR-1;
Call
extension.
PA-T:
Paging
adaptor.
Connects
TB-T
master
to
a
paging
system
and
background
music
system.
PG-lOA,
PG-30A,
PG-60A:
UL
&
CSA
LISTED
paging
amplifier,
low,
30W,
60W
(for
North
America
only).
PG-10B,PG-30B,PG-60B:
Standard
paging
amplifier.
lOW,
30W,
60W.
SP-3NA:
Ceiling
mount
speaker.
Install
with
or
without
NBZ-M
square
frame.
DB-TS:
Door
station
adaptor
(required
for
each
door
station)
■
Door
stations;
All
weather
resistant
type.
LED
mounted
on
each
cover.
IC-DC
IC-NA
IC-RA
IC-KA
IC-JA
ACTUAL
TERMINAL
LOCATIONS
ic
pY
The
master
station
terminal
block
is
located
on
back
of
the
cabinet.
nn\
itiit
iHil
■
m
-
O
,j
IC-DA-R
ID-DA
ID-NC
I
for
connecting
©
i
sub
station
\
for
connecting
j
master
station
(^
,
(^
..
for
connecting
call
extension
speaker
..
for
power
supply
to
the
door
station
adaptor
NOTE:
For
connecting
master
station
and
additional
selector,
joint
each
connector
on
back
of
the
cabinet.
-
2
-

WALL
MOUNTING
INSTALLATION
MASTER
STATION:
(1)
When
wall
mounting,
install
sub
chassis
upside
down.
(2)
When
mounting
to
a
gang
box,
use
sub
plate
(available
from
Aiphone)
as
shown
in
the
figure.
NOTE:
Sub
chassis
must
be
ALWAYS
used
for
heat
SUB
STATION:
Attach
the
mounting
bracket
to
wall
or
gang
box.
TERMINALS
WRING
Layout
your
system
in
advance.
Determine
the
location
of
each
station
and
wiring
to
each.
Two
conductors
are
repuiied
from
a
master
to
each
sub
station
under
control
of
that
master.
Three
conudctors
are
required
between
the
two
masters.
Door
station
adaptor
DB-TS
should
be
located
as
near
master
as
possible.
Three
conductors
are
required
to
DB-TS.
*
Connect
a
single
pair
of
wires
(non-polarized)
to
TB-RC
phone,
and
to
numbered
station
terminals
on
master
station
which
you
wish
to
call.
*
Adjust
call
tone
volume
as
desired
on
the
panel
of
master.
Do
not
common
one
side
of
pair
at
any
other
point
than
at
master.
Doing
so
will
affect
proper
operation
of
your
system.
Refer
to
the
connection
diagrams.
Extend
a
single
pair
of
wires
from
terminals:
S,
S
on
master
to
ICR-1,
extension
call
speaker
in
places
where
you
wish
to
receive
a
call
besides
at
master.
Refer
to
the
chart
below
and
select
the
proper
size
wire
for
your
needs.
24
AWG
22
AWG
20
AWG
18
AWG
Master
to
sub
750'
1,300'
2,000'
3,000'
Master
to
master
400'
650'
1,000'
1,600'
DB-TS
to
door
station
300'
500'
750'
1,200'
0.5
mm
0.65
mm
0.8
mm
1.0
mm
Master
to
sub
230
m
400
m
600
m
900
m
Master
to
master
120
m
'
200
m
300
m
480
m
DB-TS
to
door
station
90
m
150
m
1
230
m
360
m
After
installation
of
a
master
and
one
sub
station,
we
recommend
that
the
system
be
turned
on
and
tested
for
proper
operation.
The
system
should
further
be
tested
after
the
addition
of
each
five
stations.
INSTALLATION
OF
DOOR
STATION
1.
Terminal
N
indicates
the
number
to
which
door
will
announce.
2.
DB-TS
should
be
mounted
so
as
to
keep
wiring
to
the
master
as
short
as
possible.
3.
Mount
door
station
to
wall
or
gang
box
as
desired.
4.
Connect
terminals
1
and
2
on
DB-TS
to
door
station.
Wiring
is
non-polarized.
5.
Connect
terminals
+
and
-
to
master
station.
Observe
polarity.
NOTE:
DB-TS
can
not
be
connected
to
additional
selector.
-3
-

INSTALLATION
EXAMPLE
#(1)
:
TB-IOT
w/9
TB-RC
&
1
door
station
*
The
master
station
may
select
and
call
up
to
two
sub
stations
simultaneously,
except
including
door
station.
*
Install
DB-TS
door
station
adaptor
as
near
master
station
as
possible.
*
A
door
station
may
be
connected
to
either
master
station
but
can
not
be
connected
to
two
masters.
-
4
-

INSTALLATION
EXAMPLE
#
(2)
:
TB-IOT
w/additional
selector
&
30
TB-RC
CONNECTION
OF
TB-T
MASTER
TO
ADD-ON
SELECTOR
The
provided
connector
allows
easy
plug-in
connection
between
master
and
additional
selector.
INSTALLATION
OF
CALL
EXTENSION:
ICR-1
CONNECTOR
A
call
extension
device:
ICR-1
may
be
added
to
each
master
station
so
as
to
signal
calls
in
a
room
other
than
master’s.
Connect
terminals
S,
S
on
master
to
ICR-1
—
wiring
is
non-polarized.
After
wiring
terminals,
install
ICR-1
to
a
gang
box
or
to
wall
with
supplied
screws,
as
shown.
-
5
-

INSTALLATION
EXAMPLE
#(3)
:
2
TB-IOT
w/each
9
TB-RC
subs
*
In
the
above
example,
sub
stations
from
#1
to
#6
can
call
two
masters
simultaneously.
In
this
case,
separate
wires
(each
2)
are
required
from
sub
to
each
master.
*
When
a
sub
station
#
1
picks
up
handset,
both
masters
may
be
signalled
by
tone
and
lamp.
But
when
a
master
is
engaged
in
other
communication,
a
sub
station
#
1
may
hear
both
call
and
busy
tones.
When
a
call
is
received
by
either
master,
the
call
will
be
automatically
cancelled
at
the
other
master.
6

INSTALLATION
EXAMPLE
#
(4)
TB-IOT
SYSTEM
WITH
ONE
PAGING
BLOCK
NOTE:
IN
A
TWO-MASTER
SYSTEM,
SEPARATE
PAGING
EQUIPMENT
IS
REQUIRED
FQR
EACH
MASTER.
*
For
full
information,
please
refer
to
the
Instructions
packed
with
PA-T.
ADJUSTING
CALL
TONE
VOLUME
MASTER
STATION
.
by
The
call
tone
volume
may
be
adjusted
to
three
levels
setting
switch
as
desired.
•
TONE
VOLUME
CONTROL
M
I2r
M
SUB
STATION;
When
sub
station
is
located
in
a
quiet
place,
you
may
reduce
the
call
tone
volume
by
removing
a
jumper
between
terminals
S,
S
on
back
of
TB-RC
phone.
-
7
-

OPERATIONS
MASTER
STATION
1.
R
eceiving
a
call;
A.
Incoming
calls
are
annunciated
by
tone
and
lamp.
B.
Pick
up
handset
and
depress
the
selector
button
above
the
illuminated
LED.
C.
If
a
second
station
calls
the
annunciator
lamp
will
illuminate
but
the
tone
will
not
sound.
D.
If
a
door
station
calls
the
annunciator
lamp
will
illuminate
for
approximately
20
seconds,
and
the
tone
will
sound
unless
the
master
is
busy.
E.
Depress
OFF
button
at
the
end
of
every
conversation.
A
tone
will
sound
to
remind
you
if
you
forgot
to
depress
OFF
button.
2.
Placing
a
call;
Pick
up
handset
and
depress
selector
button
of
sub
station
desired.
Your
call
will
automatically
be
annunciated
by
audio
tone.
When
you
hear
busy
tone
upon
calling
to
another
master,
please
call
it
later.
3.
Conversation
between
subs
can
be
accomplished
as
follows
(except
to
door
station);
A.
Sub
station
#1
calls
master
and
indicates
that
it
would
like
to
talk
with
sub
station
#3.
B.
The
master
places
sub
station
#1
on
hold
by
depressing
OFF
cancel
button
and
then
calls
sub
station
#3
and
informs
him
that
sub
station
#1
is
waiting
to
talk
with
him.
C.
The
master
then
selects
sub
station
#1
again
and
hangs
up.
D.
At
the
end
of
conversation
both
parties
hang
up
and
a
tone
will
sound,
reminding
the
master
to
cancel
the
selector
switches.
4.
Paging;
A.
Pick
up
handset
and
depress
selector
button
of
zone
desired.
This
will
cut
out
background
music
and
transmit
pre¬
tone
over
paging
speakers.
Make
paging
announcement
through
handset.
B.
Upon
completing
page,
hang
up
handset
and
cancel
the
selected
button
by
depressing
OFF
button.
NOTE:
Up
to
2
paging
zones
may
be
selected
at
a
time.
SUB
STATION
To
place
a
call
simply
pick
up
handset
and
wait
for
the
master
station
to
answer.
A
tone
will
be
heard
indicating
the
master
is
ringing.
If
a
faster
repeated
tone
is
heard,
the
master
is
busy.
Your
call
is
announced
at
master
by
a
lamp
only
and
you
may
wait
for
a
reply
or
call
later.
DOOR
STATION
Momentarily
depress
the
call
button.
Talk
and
listen
hands
free
to
master
station.
Do
not
push
call
button
during
conversation.
*
*
We
at
AIPHONE
are
proud
of
our
products.
Our
designers
and
engineers
strive
to
bring
you
the
finest
in
communication
equipment.
Each
item
has
been
carefully
tested
and
inspected
before
leaving
our
factory.
Properly
installed
and
used,
your
Aiphone
intercom
system
should
give
years
of
trouble-free
service.
We
are
pleased
to
offer
the
following
warranty:
WARRANTY
Aiphone
warrants
its
products
to
be
free
from
defects
of
material
and
workmanship
under
normal
use
and
service
for
a
period
of
one
year
after
delivery
to
the
ultimate
user
and
will
repair
free
of
charge
or
replace
at
no
charge;
should
it
become
defective
upon
which
examination
shall
disclose
to
be
defective
and
under
warranty.
Aiphone
reserves
unto
itself
the
sole
right
to
make
the
final
decision
whether
there
is
a
defect
in
materials
and/or
workmanship;
and
whether
or
not
the
prod¬
uct
is
within
the
warranty.
This
warranty
shall
not
apply
to
any
Aiphone
product
which
has
been
subject
to
misuse,
neglect,
accident,
or
to
use
in
violation
of
instructions
furnished,
nor
extended
to
units
which
have
been
repaired
or
altered
outside
of
the
factory.
This
warranty
does
not
cover
batteries
or
damage
caused
by
batteries
used
in
connection
with
the
product.
This
warranty
covers
bench
repairs
only,
and
any
repairs
must
be
made
at
the
shop
or
place
des¬
ignated
in
writing
by
Aiphone.
Aiphone
will
not
be
responsible
for
any
costs
incurred
involving
on
site
service
calls.
Aiphone
Co.,
Ltd.,
Nagoya,
Japan
Aiphone
Corporation,
Bellevue,
Washington
TB-T-ME)
0788H
^1^
INTERCOM
SYSTEMS
O
AlPHOHE
HOME.
BUSINESS,
INDUSTRY
Printed
in
Japan
(E)
This manual suits for next models
1
Table of contents
Other Aiphone Telephone System manuals
Popular Telephone System manuals by other brands

Panasonic
Panasonic KX-TG6700BXB Service manual

Panasonic
Panasonic KX-TDE200AL Brochure & specs

Auerswald
Auerswald COMpact 5010 VoIP Installation and commissioning instructions

Mitel
Mitel Superset 1000 owner's manual

Toshiba
Toshiba Strata DK8 General description

Toshiba
Toshiba STRATA CIX Programming manual