PRECAUTIONS ON INSTALLATION & WIRING
GENERAL PRECAUTIONS
DISMANTLE
PROHIBITIONS
GENERAL PROHIBITIONS
Examples of Symbols;
This Manual and the Markings on the product contain various
symbols in order that the product can be used safely and properly,
and that the installer and user are protected from injury and
property damage. The following precautions must be thoroughly
read and understood before proceeding.
TC-20M
The mark indicates caution
statement (incl. danger and warning),
which is specifically shown inside.
All the products of other manufacturers, power supply, buzzer, etc. used for TC-M, are not within our warranty,
and must be used under manufacturer or distributor's specifications and warranty.
The mark indicates contents
which demands a specific
action shown inside or attached.
The mark indicates contents
which prohibit a specific action
shown inside or attached.
MOISTURE
PROHIBITIONS
1. TC-M equipment is designed for indoor use only.
Do not install outdoors.
2. TC-M system is not operational during a power failure.
3. In areas where broadcasting station antennas are close by,
intercom system may be affected by radio frequency interference.
4. Keep all DC wiring at least 30cm, 1' away from AC 100~240V
wiring, fluorescent lighting, or dimmer switches.
Otherwise, cross AC wiring at a 90°angle.
Weather conditions, such as lightning storms, may cause damage
to TC-M equipment. It is suggested to take protective measures
as follows;
• When an AC transformer is used
• When a DC power supply is used:
On the power supply with grounding terminal, be sure to take the
terminal to earth ground.
In this case, it is not necessary to connect a surge-arrester.
When using a power supply that has no grounding terminal,
install a surge-arrester in the same manner as stated above.
Surge-arrester SA-1 is available from Aiphone.
1. Do not connect any power source other than specified on
TC-M master. Fire or damage to the unit could result.
2. Do not open TC-M master. High voltage is present inside,
and it can cause electric shock.
3. Do not change or alter TC-M master. It can cause fire
or electric shock.
4. Make sure wires are connected properly before plugging in
power supply.
5. Keep TC-M master away from water or any other liquid.
Fire or electric shock could result.
6. Keep AC plug away from moisture or dust.
7. Keep AC cord away from being marred or crushed.
8. Do not plug or unplug with wet hands.
9. Do not put any metal into TC-M through openings.
It can cause fire, electric shock or unit damage.
- Places subject to moisture or humidity extremes.
- Places subject to environmental conditions,
such as oil, dust, chemicals, salt, etc.
- Places subject to constant vibration or impact.
- Places where noise generating devices such as
TV or radio are close by.
WARNING
Negligence could result in death or serious injury.
CAUTION
Negligence could result in injury or damage to property.
WARNING
CAUTION
1. Do not make call tone testing with hook switch manually held down.
The call tone sounds very loud near your ears, and can cause
your hearing damage.
2. Do not install or make any wire terminations while power supply
is plugged in. It can cause electrical shock or damage to the unit.
3. Install TC-M master in a convenient location, but not
where it could be bumped or jarred.
4. In case of electrical storms, unplug power supply from AC outlet.
It can cause fire, electric shock, or power surge damage.
5. Do not install TC-M components in any of the following locations,
as it may cause the system to malfunction;
- High or extreme cold temperature area:
under direct sunlight, near equipment that varies in temperature,
in front of air conditioner, inside a refrigerated area, etc.
GENERAL PRECAUTIONS
GENERAL INSTRUCTIONS
TC-10M
AC trans.
TC-10M TC-20M
AC 15 – 16V
or DC 18V
Surge-
arrester
Install a surge-arrester
(discharging voltage: 100~180V)
at a point close to the output,
taken to earth ground.
Grounded
– 1
–
83945900 0102 A
A

TC-20M
TC-10M
TB-SE
TB-SE-R
TC-20G TC-40G
・Master stations
・Add-on selectors
・Sub stations ・Power supplies
PS-18C
(AC 120V)
PS-18E
(AC 220 ~ 240V)
・Door station adaptors
TB-AD1 TB-AD10
Notes;
1. TC-M & TC-G units can not interchangeably be used with TB-M & TB-G units.
2. TC-M masters & accessories are NOT compatible with TB-10T and TB-20T.
3. TB-RC sub station (for TB-T) can be used with TB-M & TC-M masters.
4. Video accessories;
TC-M system may be combined with a TB-ADM10 video adaptor, which can connect
up to 10 video door stations MK series (MK-DAC, MK-DBC, MK-DS/B), etc. Install a
video monitor MYH-CU beside TC-M. For details, refer to the Manual packed with TB-ADM10.
・Call extension
IER-2
・External signaling relay
TAR-3
IF-DA
TC-10M
TC-20M
TC-20G
TC-40G
TB-SE
TB-SE-R
IER-2
TAR-3
TB-AD1
TB-AD10
IF-DA
PS-18C
PS-18E
10-call master
20-call master
20-call add-on selector
40-call add-on selector
Handset sub station
Handset sub station, red case
Call extension speaker (for TC-M)
External signaling relay
(Requires a 6V DC power supply)
1-call door station adaptor
10-call door station adaptor
Door station (any IE/IF series)
18V DC power supply (AC 120V)
18V DC power supply (AC 220 ~ 240V)
TC-10M or TC-20M
w/TC-20G or TC-40G
IF-DA TB-AD1
TB-SE
ea. 2
or
TB-SE
TB-SETB-SE
25
– 2 –
1
System outline
The TC-M is an internal telephone type system, expandable up to 60 subs and 2 masters.
Communicates with TB-SE handset subs and IE/IF door stations.
1
P
ac
k
age content
s
1
M
aster station (T
C
-10M or T
C
-20M)
2
Di
rectory car
d
&
cove
r
3
S
crews-pack (2 types, ea. 4 pcs
)
4
Wa
ll-mo
u
nt
c
r
ad
l
e
5
I
nstallation & O
p
eration Manua
l

– 3 –
22NAMES & FEATURES
Names & functions
TC-10M and TC-20M master station is streamline and modernly designed. The master console may
be placed on desk or wall-mounted.
The selector switch bank is aligned vertically, with each station having its own directory. Station
numbers count top to bottom 1 to 10 on first switch bank, and 11 to 20 on the second switch bank of
TC-20M. The supplied directory card and cover can be attached from the left.
Features Transfer switch and LED in the center of front panel. Single transfer button automatically
connects the master with the next TB-SE sub that has called (max. 2)
TC-20G or TC-40G add-on selector plugs into TC-M back panel, and can be placed on either side of
master.
Features
•TC-20G or TC-40G add-on selector connects additional TB-SE subs, allowing system
expansion.
•One or dual-master configuration.
•TB-AD1 adaptor connects TC-M with an IE/IF Series audio door station (up to 3).
•For 4 to max. 10 doors, use a TB-AD10 adaptor. Or alternatively, TB-ADM10 adaptor
for max. 10 PanTilt door stations. Allows TC-M to communicate and monitor each MY
door station audio-visually either selectively or all in succession. Refer to the TB-
ADM10 Manual.
•Call extension IER-2 allows incoming call tone to be heard at a remote location.
•Master station can call sub by tone, and optional external buzzer.
Receive & call tone
volume controls
Transfer switch
& LED
Plug-in connector
(on the back)
Station-select or
call button with LED
TC-10M with TC-20G add-on selector
Power on switch
(on rear panel)
97 mm
3-13/16”
230 mm
9”
405 mm
16”
Directory card
and cover
Power on &
in-use LEDs

4
4WIRING
– 4 –
Terminal-block layout
Meaning of terminal symbols
E terminal is common calling and communication line.
No. 1~40 terminals are selective station points, providing selective calling and communication.
C & M terminals are master-to-master communication.
R & T terminals are master-to-door adaptor transmit and receive lines.
S & S terminals are call tone output to IER-2 call extension speaker.
Cable requirements
Use 2-conductor cable (twisted or non-twisted) homerun to each sub station (0.65 ~ 1.0mm
φ,
22 ~ 18AWG).
+
−
+
−
TC-10M
Each E terminal may have
one to three wires from
TB-SE terminal 2.
2 wires from TB-SE subs must
not be made common at any
other point than on the
TC-M terminal block.
1
12V
2
3
4
5
6
7
8
9
10
E
E
E
E
E
E
C
M
R
R
T
T
S
S
1
12V
2
3
4
5
6
7
8
9
10
+
−
+
−
E
E
E
E
E
E
C
M
R
R
T
T
S
S
DC18V or
AC15-16V
E
E
E
E
E
E
E
E
20
19
17
16
18
15
13
12
14
11
TC-20M
DC18V or
AC15-16V Connect power supply to
TC-M Master station
(Max. 25m/1.0mm
φ, 80´/18AWG)
★
1
12V
2
3
4
5
6
7
8
9
10
+
−
E
E
E
E
E
E
E
E
D10
D9
D7
D6
D8
D5
D3
D2
D4
D1
TB-AD10
E
E
E
E
E
E
E
E
20
19
17
16
18
15
13
12
14
11
1
2
3
4
5
6
6
8
9
10
E
E
E
E
E
E
E
E
TC-20G
E
E
E
E
E
E
E
E
40
39
37
36
38
35
33
32
34
31
E
E
E
E
E
E
E
E
30
29
27
26
28
25
23
22
24
21
11
12
13
14
15
16
17
18
19
20
E
E
E
E
E
E
E
E
1
2
3
4
5
6
7
8
9
10
E
E
E
E
E
E
E
E
TC-40G
R
T
12V
2
+
−
TB-AD1
R
T
N
1

– 5 –
TB-AD1
12V
+
−
R
T
N
1
2
DC12V input
Pre-tone sounds at door
station when selected from
TC-M master. The feature
can be muted by switching
to OFF.
OFF ON
TC-10M single-master system with a door station
TC-10M
IF-DA TB-AD1
TB-SE
IF-DA
TB-AD1
TC-10M
TB-SE
Master station
Sub station
Door adaptor
1
2
E
1
2
E
1
2
E
1
2
E
1
2
E
1
2
1
2
E
1
2
1
2
1
2
3
4
5
6
7
8
9
10
N
1
2
1
2
+
−
R
T
12V 12V
+
−
T
RCall extension
IER-2
(one per TC-M)
S
S
To: power supply
Do not connect any power source here.★
IN
AC 15-16V
or DC18V
12V OUT
Any # terminal on TC-M or TC-G
add-on selector.
1
E
• The # terminals on the master station connect to
terminal 1 on each TB-SE sub. These numbers
become the sub's station number, numbered from
the top on each 10-button row.
★2 parallel wires per TB-SE sub, nonpolarized.
Be sure to run each pair of wires directly to
TC-M master.
E line in each pair should not be connected at
any other point of cable than E terminals on
TC-M, which can accomodate 2 ~ 3 TB-SE subs.
The master can select the door station for audio monitoring at any time. The call
announce pretone is selectable.
Set the switch to ON position for pretone, removing the cover of front case.
D
i
a
m
e
t
er
D
i
s
t
a
n
ce
0
.
65
m
m
6
5
m
0
.
8
mm
100
m
1
.
0
m
m
1
50m
Di
amete
r
Di
stanc
e
0
.
6
5m
m
1
50m
0
.
8
mm
230
m
1.
0
m
m
360m
D
i
a
m
e
t
er
D
i
s
t
a
n
ce
0
.
6
5m
m
400m
0
.
8
mm
600
m
1
.
0
m
m
900m
A
W
G
D
i
s
t
a
n
ce
22AW
G
210
'
2
0
AW
G
330
'
18
AW
G
4
95
'
A
W
G
Di
stanc
e
22AW
G
500'
20AW
G
7
50'
1
8AW
G
1
,
200
'
A
W
G
D
i
s
t
a
n
ce
22AW
G
1,300
'
20AW
G
2
,000
'
1
8AW
G
3,000
'
T
C
-M to TB-
S
E su
b
W
irin
g
distanc
e
TB-AD1 t
o
aud
i
o
doo
r
s
t
a
ti
on
T
C
-M to TB-AD
1

– 6 –
TC-10M single-master with TC-(20,40)G add-on selector
TC-10M
IF-DA TB-AD1
TB-SE
TC-20G
IF-DA
TB-AD1
E
1
2
1
2
E
1
2
E
1
2
E
1
2
E
1
2
1
2
E
1
2
1
2
1
2
3
4
5
6
7
8
9
10
N
1
2
1
2
+
−
R
T
12V 12V
+
−
T
Sub station
TB-SE
Door adaptor
11
12
13
14
15
16
17
18
E
1
19
Add-on selector
TC-20G
R
1
2
E
21
2
E
31
2
E
41
2
E
51
2
E
61
2
E
71
2
81
2
E
91
2
10 1
2
TB-SE
Sub station
TC-10M
Master station
S
S
Connector
To: power supply
Do not connect any
power source here.
★
IN
AC 15-16V
or DC18V
12V OUT
Designate any # terminal
for TB-AD1
20
Call extension
IER-2
(one per TC-M)
1
E
•
TC-M master, with a TC-G add-on selector,
expands its capacity up to 60 substations.
Choose the master and add-on selector to
meet your system's requirements.
Up to 3 TB-AD1 door station adaptors per TC-M.
5 wires homerun to TC-M.

– 7 –
TB-AD10, 10-call door adaptor may be wired to any # terminal on TC-M or TC-G add-on selector,
connecting max. 10 IE/IF door stations. Features two-way calling and communication with door
station, including optional pretone. Set the switch to ON position, if pretone to door is required.
TC-20M single-master with up to 10 door stations
TC-20M
TB-SE
TB-AD10
IF-DA
TC-20M
Master station
Sub station
TB-SE
E
D1
10-call door adaptor
TB-AD10
1
2
E
D2 1
2
E
D3 1
2
E
D4 1
2
E
D5 1
2
E
D6 1
2
E
D7 1
2
D8 1
2
E
D9 1
2
D10 1
2
IF-DA
E
1
2
E
1
2
E
1
2
E
1
2
E
1
2
E
1
2
E
1
2
E
1
2
1
2
1
2
3
4
5
6
7
8
9
10
12V+
−
T
R
S
S
To: power supply
Do not connect any
power source here.
★
IN
AC 15-16V
or DC18V
12V OUT
12V
+
−
T
R
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
10
Call extension
IER-2
(one per TC-M)
1
E
In place of TB-SE handset subs, TC-M master
may have max. 10 door stations, by using a
TB-AD10 adaptor.
OFF
ON
TB-AD10
D
i
a
m
e
t
er
Di
stanc
e
0
.
65
m
m
1
5
0
m
0
.
8
m
m
230
m
1
.
0
m
m
360
m
Di
amete
r
D
i
s
t
a
n
ce
0
.
6
5m
m
65
m
0
.
8
m
m
100
m
1
.
0
m
m
150
m
A
W
G
Di
stanc
e
2
2AW
G
5
00
'
20
AW
G
7
50
'
18
AW
G
1
,200
'
A
W
G
D
i
s
t
a
n
ce
2
2AW
G
2
1
0
'
2
0AW
G
330
'
1
8AW
G
495
'
TB-AD1
0
to audio IF-D
A
T
C
-M to TB-AD1
0
Wirin
g
distance
:

– 8 –
TC-M dual-master system
TC-10M
IF-DA TB-AD1
TB-SE
TC-10M
Single-pair,
nonpolarized
2-pairs
polarized
TB-SE
IF-DA
TB-AD1
TC-10M
N
1
2
1
2
+
−
T
+
−
T
E
1
2
1
2
E
1
2
E
1
2
1
2
E
1
2
1
2
E
1
2
1
2
3
4
5
6
7
8
9
10
TB-SE
Sub station (common)
Door adaptor
10
12V
Master station
1
2
1
2
RR
E
M
C
Polarized
+
−
T
E
E
E
E
E
E
M
C
12V
R
1
2
3
4
5
6
7
8
9
TB-SE
Sub station
S
S
S
S
TC-10M
Master station
To power supply
The number terminal
jumpered to “M” at each
master establishes master
-to- master communication.
★
1
2
IN
AC 15-16V
or DC18V
12V OUT
IN
AC 15-16V
or DC18V
12V OUT
Polarized
To power supply
Do not connect
any power source
★
Designate any # terminal
for TB-AD1
Call extension
IER-2
1
E
Call extension
IER-2
1
E
• Common TB-SE sub rings two TC-M Masters.
• Each master can call TB-SE sub selectively.
• Master-to-master communication.
+
–
T
R
1
2
N
+
–
T
R
1
+
–
T
R
1
1
2
E
2
1
E
2
1
2
1
NEVER
NEVER
21
21
IMPORTANT
Do not use the following wiring methods. They will cause the system
to malfunction:
Do not parallel sub station wires
between TC-M master stations.
Wiring from TB-SE must be
homerun to EACH master station.
Door adaptor TB-AD1(10) can only
be wired to one master. Doors
cannot call both master stations.
Di
amete
r
Di
stanc
e
0
.
6
5m
m
200m
0
.
8
m
m
300m
1
.
0
m
m
480m
AW
G
Di
s
t
a
n
ce
22AW
G
650'
20AW
G
1
,
000
'
18AW
G
1
,
570
'
W
i
r
i
ng d
i
stance:
Between T
C
-M master
s

– 9 –
5
5MOUNTING
TC-(10,20)M with TC-(20,40)G
Remove 2 screws on front panel, removing the cover on upper end and area/section plate. Lift off front
case holding sides at top. Disconnect the intercom by unplugging the connector.
Open a cable inlet hole (rubber part) on bottom of chassis. Pull in cable(s), and make wire terminations.
Use attached cable clamps(s) for neat and secured connection. Reconnect and mount front case to
chassis, attaching the cover and plate in place.
When wall-mounting, separate the front panel from chassis, as explained above. Install the chassis
upside down on the wall, onto a single-gang or two-gang box.
★
TC-M master wall-mounts with TC-G (and TB-AD10) attached.
Decide the exact location of TB-M master, and use the following measurements to mount the add-on components.
Connecting a buzzer at a TB-SE sub
When called by TC-M master, buzzer is
activated and on TB-SE sub, call tone sounds
at reduced volume.
TAR-3 relay activates an AC-operated buzzer:
AC 240V, 0.3A. DC-operated buzzer must be
mechanical type: DC 24V, 1.0A.
Do not use DC electronic buzzer.
Area / section plate
Lift off front case holding
sides at top. Screws
Cover
Open a knock-out
hole.
Lift off front case holding sides
at top.
Screws
Single-gang or
2-gang box
Chassis mounts upside down.
83.5 mm,
3-5/16"
TC-M
master
TB-SE
sub
TAR-3
DC6V, 160mA
To : power source
White Orange
Blue Orange
Red Black
White (–)
PS-6D
power supply
(SKK-620
in USA)
Red (+)
Remove
shorting link.
Buzzer
1
2
3
4
1
E
+
–
TC-M master TC-G add-on
selector
TB-AD10 door
adaptor
Centers of each chassis
(or gang boxes)
AB
Desk-top mount
i
ng Wall-mount
i
n
g
W
all-mount
i
ng gu
i
d
e
Master Attached Guide A Attached Guide B
Attached Guide A Attached
TC-20G 202.5, 8" TB-AD10 150.0, 6"
202.5, 8" TB-AD10
TC-10M TC-40G 277.5, 11" TB-AD10 225.0, 9"
TC-40G 277.5, 11" TB-AD10
TB-AD10 202.5, 8" ––– –––
202.5, 8" –––
T
C
-2
0G
240.0
,
9-1/2
"
TB-AD10 150.0, 6"
TC-20M TC-40G
31
5.
0
,
12-
1
/
2"
TB-AD10 225.0, 9"
T
B-AD1
0
240.0
,
9-1/2
"
––– –––

– 10 –
6
6OPERATIONS
Calling and receiving To call a TB-SE sub, the other master or audio door station pick up
handset and depress a station-select button. When called by
tremolo tone, pick up and depress the LED-lit select button. LED
remains on while in communication. Communicating TC-M is
notified of a call with a lit LED only. The audible call tone will
resume when the handset is hung up.
Receiving a call from audio IE/IF door station
When the door station places a call with call button, a tremolo tone
is activated on the TC-M, which stays on approx. 40 seconds. The
master replies by selecting the station button that is lit. At the door
station, when selected, a pretone is heard, unless it is muted at the
TB-AD1, 10 adaptor.
“Transfer” allows two TB-SE subs to communicate with each other
When a master receives a call from sub A, requesting transfer of
call, TC-M leaves sub A waiting, pressing a sub B select button.
When sub B picks up the call (sub A hears a busy tone), TC-M
depresses Transfer switch.
TC-M then reselects waiting sub A with red LED on. Three parties
are on the line, and TC-M may hang up.
Door-to-master or master-to-master calls are not transferrable.
If transfer LED is lit when a transfer is not being made, it can be
cleared by pressing “transfer” switch.
Red LED
Station-select button for
sub, door or master
Transfer switch & LED
Do not press more than one buttons,
when calling.
Power on LED
In-use LED
Indicates TC-M master is not put
in standby. Make sure handset is
properly placed.
Speaker for call-in tone
Transfer switch & LED
Receiver (upper) & call tone
volume controls (3 levels)
Attach the directory &
cover from left side to
place.
Station-select button
Call in LED
Also indicates waiting for
transfer of call
Single TC-M system
TC-(10, 20)M master communicates with 10 or
20 TB-SE subs. TC-20G or TC-40G add-on
communicates with 20 to 40 additional subs.
TC-M single-master system
IF-DA TB-AD1 OFF ON

– 11 –
7
7TECHNICAL PRECAUTIONS
The power switch is located on back panel of TC-M console, which should be placed ON, except for
special occasions. If the system malfunctions, turn off and on TC-M master, by which the system
may reset itself. Possible causes are; power supply is unplugged, connecting wires are loosened or
shorted. Do not attempt to open TC-M equipment nor change wiring. Ask qualified personnel.
At end of each communication, be sure to place handset in cradle properly. If not, TC-M master or
TB-SE sub will not hear the call tone.
The TC-M is rated to operate at temperatures between 0°C ~ +40°C (32°F ~ 104°F).
Clean the TC-M equipment with a soft cloth dampened with neutral household cleanser. Never use
any abrasive cleaner or cloth.
TC-M places a buzzer-activating call to a TB-SE sub
Buzzer sounds continuously at TB-SE sub, in
addition to ordinary tremolo. Pick up on the
TB-SE station, that the buzzer is connected to.
Adjusting receive and call tone volume
Upper control adjusts handset receiver volume,
when TC-M does not hear a TB-SE sub clearly.
Tone control adjusts ringing tremolo, 3 levels.
TC-M dual-master system
Two masters call and communicate with each assigned select
button. Transfer of a sub’s call to another on the other master is not
possible.
A call from TB-SE subs that are connected to two masters activates
tremolo tone at both masters. When the controlling TC-M is busy,
the other TC-M may pick up. In this case, the sub hears both
tremolo and busy tones.
Dual-master has an operation that, when TC-M1 places a call to
either TC-M2 or a common TB-SE that is already in
communication, the talk line is connected among 3 parties.
It reduces communication volume. One party should hang up to
restore normal volume.
Receive
Call tone
3-levels each
TB-SE sub operation
To call TC-M master, simply pick up and it rings TC-M with tremolo
tone, which continues ringing until the call is answered. Intermittent
tone means the master is occupied. Hang up or continue to hold.
When called by tremolo tone, simply pick up.
Speaker
for call tone
Common TB-SE(s)
TC-M 1 TC-M 2

Model Height Width Depth Height Width Depth Weight
TC-10M 117 mm x 255 mm x 230 mm 4-5/8" x 10" x 9" 1.8 kg (3.97 lbs.)
TC-20M 117 mm x 330 mm x 230 mm 4-5/8" x 13" x 9" 2.3 kg (5.07 lbs.)
TC-20G 97 mm x 150 mm x 230 mm 3-13/16" x 6" x 9" 1.0 kg (2.20 lbs.)
TC-40G 97 mm x 300 mm x 230 mm 3-13/16" x 11-13/16" x 9" 1.9 kg (4.19 lbs.)
TB-AD10 97 mm x 150 mm x 230 mm 3-13/16" x 6" x 9" 1.1 kg (2.43 lbs.)
TB-AD1 140 mm x 74 mm x 42 mm 5-1/2" x 3" x 1-5/8" 160 g (0.35 lbs.)
WARRANTY
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a
period of one year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it
become defective upon which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself
the sole right to make the final decision whether there is a defect in materials and/or workmanship; and whether or not the
product is within the warranty.
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in
violation of instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This
warranty does not cover batteries or damage caused by batteries used in connection with the product.
This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by
Aiphone.
Aiphone will not be responsible for any costs incurred involving on site service calls.
8
8SPECIFICATIONS
Power source DC18V, 350mA max. or AC 15 – 16V, 50/60Hz. 750mA max.
Power consumption 6W max. 3W (standby)
Capacity 60 stations max., TB-SE or door stations incl.
One add-on selector TC-20G or TC-40G per TC-M. 1 to 3 TB-AD1 door adaptors or one
TB-AD10 only alternatively, or one TB-ADM10 only.
Calling TB-SE sub’s call-in is annunciated with intermittent tremolo tone and LED,lighting in red,
both of which are held (approx. 40 seconds for IE/IF door stations).
Station-select button calls each TB-SE with intermittent tone. Corresponding LED is lit to indicate
which sub is called. Master can call IE/IF door station by voice, with or without pretone (selectable).
Communication Both stations communicate simultaneously via handset.
– 12 –
Dimensions & weight
Compatibility TC-M system components: TC-(10,20)M, TC-(20,40)G & TB-AD(1,10), cannot be intermixed
with TB-(10,20)T masters, while TB-RC handset sub can be used with TC-M system.
T
C
-M to TB-
SE
T
C
-M to T
C
-
M
T
C
-M to TB-AD
1
T
C
-M to TB-AD1
0
TB-AD1
(
10
)
to IE/IF doo
r
0
.
65
m
m
φ
400
m
200
m
6
5
m
1
5
0
m
0
.
8
mm
φ
600m
300m
100m
230m
1.
0
m
m
φ
900
m
480
m
1
5
0
m
360
m
22AW
G
1
,
300
’
650
’
2
1
0
’
500
’
2
0AW
G
2
,000
’
1,
000
’
330’
7
50’
18
AW
G
3
,000
’
1,
570
’
495
’
1,
200
’
Wi
r
i
ng d
i
stanc
e
Wi
r
i
n
g
2 conductors
(p
arallel
)
or a
p
air in multi-cond. cable TC-M to ea. TB-S
E
5 conductors T
C
-M to TB-AD
1
1
4 conductors max T
C
-M to TB-AD1
0
3
conductors between T
C
-M’
s
★
In TC-M dual-master s
y
stem, two parallel conductors cables are required for each common TB-S
E
sub
.
Printed in Japan (E)
A
IPHONE CO.
,
LTD.
,
NAGOYA
,
JAPA
N
A
IPHONE CORPORATION, BELLEVUE, WA, US
A
A
IPH
O
NE EUR
O
PE N.V., ANTWERP, BEL
G
IU
M
T
C-M-I(E) 0102
A
Other manuals for Tc-10m
2
This manual suits for next models
1
Table of contents
Other Aiphone Telephone System manuals
Popular Telephone System manuals by other brands

Panasonic
Panasonic KX-T2375MXW Service manual

Nortel
Nortel Meridian Meridian 1 installation manual

SpectraLink
SpectraLink 150 M3 MCU Installation and operation guide

Lucent Technologies
Lucent Technologies MERLIN LEGEND Release 3.1 MLX Queued Call... Operator's guide

Mitel
Mitel Superset 1000 owner's manual

Samsung
Samsung DCS-816 installation manual